Correspondence • r il 1 Construction Management • Project Management A 701 Dexter Avenue North /301, Seattle, Washington 98109 -0891 i � Tel: E-m of 285 -0300 /Fax: (2061 285-4371 l Oly ®oac OLYMPIC • ASSOCIATES COMPANY RECEIVED June 23, 1999 JUN 2 4 MS RE: Magnolia Hi Fi S MUNITY DEVELOPMENT 11680 S.W. Pacific Hwy -- Building Plan Review Response PC #: 5 -50c BUP #: 1999 -00217 Attn: Robert Poskin Plans Examiner The plans have been changed in response to your correction letter, dated June 15, 1999, in the following way: 0 (41.11 Acces ' 1 ©t. etails have been provided for accessible cashier counter on A2.1 . Stair details have been provided on A6.1. Energy Compliance: : 1. Energy Compliance forms 2a, 3a, 3b, 5a thru 5c are enclosed. Fire and Life Safety: • 1. Notes have been added to sheets A2.2, A4.1 & a7.1 to show a 1 hour separation between Auto install and the warehouse and the space above the auto install. 2. Exit signs have been added — see sheets A2.1 & A2.2 — in the following locations: a. At the entrance of the hallway on the main floor, a directional arrow b. At the end of the hallway on the main floor near the stairwell entrance, a directional arrow. c. • At the bottom of the stairwell, a directional arrow d. At Door (9), an exit sign e. At the new exit door from the basement 3. Door #6 the swing was reversed on A2.2 4. Details have been added to A4.1 about the draft stops, locations of draft stops shown on A4.1. 5. A note was added to A2.2 stating that the auto install area shall have a non - combustible floor surface, constructed with non - absorbent material. The floor area shall also drain to Q { an approved oil separator or trap discharging to sewers in accordance with the plumbing code. 6. Fire extinguishers per UFC Std. 10 -1 have been added — see sheets A2.1 & A2.2. Structural: 1. Drifting snow load calculations are enclosed. 2. Completed inspection forms are enclosed. Fire: 1. Notes for a "knox box" have been added to A2.1 per UFC (TVFR) 902.4.2 2. The "Fire Department Building Survey" form has been completed and one set of architectural drawings and a site plan have been sent to: Eric McMullen, DFM Tualatin Valley Fire and Rescue P.O. Box 4755 Beaverton, OR 97076 We have enclosed three copies of revised submittal documents in addition to all of the forms indicated above. Sincerely, OLYMP ASSOCIATES COMPANY arty K. o Vice Presi eit op June 15, 1999 CITY OF TIGARD Olympic Associates Company OREGON 701 Dexter Avenue #301 Seattle, WA 98109 RE: Magnolia Hi Fi Building Plan Review 11680 SW Pacific Hwy PC #: 5 -50c BUP#: 1999 -00217 Use: MIS3 /S2 Occupant Load: 285 Submittal documents for the above referenced project have been reviewed for conformance with the applicable 1998 Oregon Specialty Codes and other applicable codes and standards. The following comments are noted: (ACCESSIBILITY 1. Provide details for an accessible cashier counter. OSSC, Section 1108.4.7.2. 2. Stairs shall comply with OSSC, Section 1109.8.2, 8.3, 8.4, and 1109.8.6. Provide details. 'ENERGY COMPLIANCE 1 1. Submit completed Energy Compliance Forms 2a, 3a, 3b, and 5a through 5c from the April 1, 1996 Revised Oregon Energy Code. FIRE AND LIFE SAFETY 1. Drawing A2.2 — The auto install has been assigned a 53 classification, OSSC, Section 311.2.3.1. This requires a one -hour separation between the warehouse (S -2), OSSC, Table 3 -B, and a one -hour floor ceiling separation between the S -3 and M above. Door #8 shall have a fire resistance rating of one -hour. OSSC, Section 302.3. The door shall comply with OSSC, Section 713. 2. Exit signs shall be placed as follows: OSSC, Section 1003.2.8 a. At the entrance of the hallway on the main floor, a directional arrow. b. At the end of the hallway on the main floor near the stairwell entrance, a directional arrow. c. At the bottom of the stairwell, a directional arrow. d. At Door (9), an exit sign. 3. Door #6, the swing impedes the required landing length. Reverse the swing. OSSC, Section 1003.3.3.5. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Magnolia Hi Fi Building Plan Review PC #: 5-50c BUP #: 1999 -00217 Page #2 4. Provide details showing required draft stops. OSSC, Section 708.3. 5. The auto install area shall have a non - combustible floor surface, constructed with non - absorbent material. The floor area shall also drain to an approved oil separator or trap discharging to sewers in accordance with the plumbing code. 6. Provide Type 2 -A fire extinguishers throughout so that the travel distance to an extinguisher does not exceed 75 feet [UFC Std. 10 -1]. • 'STRUCTURAL 1. Provide drifting snow load calculations. OSSC, Section 1614. 2. Complete special inspection forms, return to this writer. I FIRE 1. Provide a knox box not less than eight feet nor more than 10 feet above the . walking surface. UFC (TVFR) 902.4.2. Please contact Mr. Eric McMullen, Deputy Fire Marshall at 503 - 237 -5664 for further clarification. 2. Complete the enclosed "Fire Department Building Survey ", return same with one set of architectural drawings and a site plan to: Eric McMullen, DFM • Tualatin Valley Fire and Rescue PO Box 4755 . Beaverton, OR 97076 • I DEFERRED SUBMITTALS 1 1. Mechanical, plumbing, electrical. Please submit three copies of revised submittal documents and a letter indicating your response to the above comments for review. Please call me at (503) 639 -4171 if you have any questions. Sincerely, Robe CBO PLANS EXAMINER • hbldglpnnsyslbup99217.doc •