Loading...
Plans //632 i?.c c hipc7 mz•e_? - te q • WoodWorks SIZER SOFTWARE FOR WOOD DESIGN File Name: 11 WoodWorks SIZER 1.Oj 6 Jul,1998 11:22 COMPANY I PROJECT DESIGN CHECK DESIGN DATA: code: NDS -1991 type: Beam database: Custom •material: Glulam Simple _ lateral support: Top= Full Bottom= @Supports total length: 37.00 [ft] INPUT LOADS: (force =kips, pressure =psf, udl =plf, location =ft) Load I Distribute 1 Type I Magnitude I Location I Pattern I I I Start End I Start End I Load I I I I I 1 Full UDL Dead 80.00 No 2 Full UDL Snow 200.00 No 3 Point Dead 0.18 0.50 No 4 Point Dead 0.18 4.25 No 5 Point Dead 0.18 32.75 No 6 Point Dead 0.18 36.50 No Self - weight of members has NOT been included. ***************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** DESIGN SECTION: VG West.DF, 24F -V4, 5.125x19.5 @ 0 plf ***************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** MAXIMUM REACTIONS and BEARING LENGTHS (force =kips, length =in) 37.0 ft I 1 A A I I Reaction 5.54 5.54 • B.Length 1.7 1.7 SECTION vs. DESIGN CODE (stress =psi, deflection =in) - // Criteria I Analysis Value I Design Value I Analysis /Design I `Z PnQFi Shear I fv @d = 74 I Fv' = 218 I fv /Fv' = 0.34 I e � G 1 '4 t.♦Y Bending( +) fb = 1802 Fb' = 2484 fb /Fb' = 0.73 ll, Live Defl'n 1.48 = L /300 1.85 = L/240 0.80 Total Defl'n 2.43 = L/182 2.47 = L /180 0.99 V i • E ON Bending ( +) : Crit.LC#= 2 CD= 1.15 CL =1.000 CV =0.900 (KL =1) �:_ ; CY 77 , .a, Shear : Crit.LC#= 2 CD= 1.15 V @d= 4.90 " �94 ^ 1\11GO Deflection: Crit.LC # = 2 Total Deflection = 1.50(Defln dead) + Defln Live. EXPIRES: 12 - - DESIGN NOTES:' 1. Please verify that the default deflection limits are appropriate for your application. 2. GLULAM: The loading coefficient KL used in the calculation of Cv is assumed to be unity for all cases. This is conservative except where point loads occur at 1/3 points of a span (NDS Table 5.3.2). 3. GLULAM: bxd = actual breadth x actual depth. 4. Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3.3. • WoodWorks SIZER SOFTWARE FOR WOOD DESIGN • • File Name: 11 WoodWorks SIZER 1.Oj 6 Jul,1998 11:39 COMPANY I PROJECT DESIGN CHECK DESIGN DATA: code: NDS -1991 type: Beam database: Custom material: Glulam Simple lateral support: Top= Full Bottom= @Supports total length: 86.00 [ft] INPUT LOADS: (force =kips, pressure =psf, udl =plf, location =ft) Load I Distribute I Type I Magnitude I Location I Pattern I I I Start End I Start End 1 Load I I I I 1 Full UDL Dead 340.00 No 2 Full UDL Snow 850.00 No 3 Point Dead 0.50 43.00 No 4 Point Dead 0.50 35.00 No Self- weight of members has NOT been included. ***************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** DESIGN SECTION: VG West.DF, 24F -V4, 10.75x64.5 @ 0 plf ***************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** MAXIMUM REACTIONS and BEARING LENGTHS (force =kips, length =in) 86.0 ft I A A Reaction 51.72 51.62 B.Length 7.4 7.4 * * * ** WARNING: Member length exceeds typical stock length of 41.0 [ft] SECTION vs. DESIGN CODE (stress =psi, deflection =in) Criteria I Analysis Value 1 Design Value I Analysis /Design I 1 1 Shear fv @d = 98 Fv' = 218 fv /Fv' = 0.45 Ep PROir Bending ( +) fb = 1803 Fb' = 1881 fb /Fb' = 0.96�(� N c � Live Defl'n 2.42 = L/426 4.30 = L/240 0.56 £ �i Total Defl'n 3.95 = L/261 5.73 = L /180 0.69 ` 11 .1)4p Bending( +): Crit.LC#= 2 CD= 1.15 CL =1.000 CV= 0.682(KL =1) _•EG•N - Shear : Crit.LC#= 2 CD= 1.15 V @d =45.32 /Ufe ti Deflection: Crit.LC # = 2 Total Deflection = 1.50(Defln_dead) + Defln_Live. " S ,\C' DESIGN NOTES: 1. Please verify that the default deflection limits are appropriate (EXPIRES 12 I for your application. 2. GLULAM: The loading coefficient KL used in the calculation of Cv is assumed to be unity for all cases. This is conservative except where point loads occur at 1/3 points of a span (NDS Table 5.3.2). 3. GLULAM: bxd = actual breadth x actual depth. 4. Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3 • WoodWorks SIZER SOFTWARE FOR WOOD DESIGN File Name: untitled WoodWorks SIZER 1.Oj 6 Jul,1998 13:52 COMPANY I PROJECT DESIGN CHECK • DESIGN DATA: code: NDS -1991 type: RoofJoist database: Custom material: Lumber -soft lateral support: Top= Full Bottom= @Supports total length: 8.00 [ft] repetitive factor: applied where applicable. INPUT LOADS: (force =kips, pressure =psf, udl =plf, location =ft) Load I Distribute 1 Type I Magnitude I Location I Pattern I I I Start End I Start End 1 Load I I I I I 1 Full UDL Dead 40.00 No 2 Full UDL Snow 100.00 No 3 Point Dead 0.12 6.00 No Self- weight of members has NOT been included. ***************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** DESIGN SECTION: D.Fir -L, No.2, 4x6 @ 0 plf ***************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** MAXIMUM REACTIONS and BEARING LENGTHS (force =kips, length =in) 8.0 ft I 1 A A 1 Reaction 0.59 0.65 B.Length 1.0 1.0 SECTION vs. DESIGN CODE (stress =psi, deflection =in) / Criteria I Analysis Value 1 Design Value 1 Analysis /Design I a , QED PROF I I I I $ /;A Shear fv @d = 45 Fv' = 109 fv /Fv' = 0.42 ` � 1 Bending( +) fb = 842 Fb' = 1504 fb /Fb' = 0.56 Live Defl'n 0.12 = L/808 0.40 = L/240 0.30 �� Total Defl'n 0.22 = L/440 0.53 = L /180 0.41 A O ./ •'E ON ( " \ \ Bending ( +) : Crit.LC#= 2 CD= 1.15 CL =1.000 Cr= 1.15 �� �`GQ Shear : Crit.LC#= 2 CD= 1.15 V @d= 0.58 Deflection: Crit.LC # = 2 Total Deflection = 1.50(Defln_dead) + Defln_Live. EXPIRES. 12 - 31.88 DESIGN NOTES: 1. Please verify that the default deflection limits are appropriate for your application. 2. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 5 / /-P5o& U'?- 01 C77Fg - A LO: AC 7 C APAC/T 11 oic ACTU C_OPO = 625 Bas : unit dimensions 48TJ004 -007 I: `':f: (rrie £ I BOX CORNER WEIGHT' '• 0'- 1'13/16" / � 0' - 5/8' 1. - ACC S S V ANEL um* '1 c, ( • [46.51 (411 (3051 48J A B C D • ! ■ -� lb kg lb kg lb kg lb kg I ' 0 ' - 8' E/F004 140 63.5 105 47.6 159 72.1 56 25.4 • `� - (2031 • . ,( �_ - ri - D /E/F005 142 64.4 106 48.1 162 73.5 60 27.2 D /E/F006 150 68.0 115 52.2 160 72.6 65 29.5 I /j i CONDENSER COIL 1 D /E/F007 -165 74.8 136 61.7 200 90.7 64 29.0 2' -9 5/16' (846.516" i Weights are for unit only (aluminum plate (ins) and do not include options or crating. I Vi- " i' O F• UNI 1 CONNECTION SIZES BOTTOM POWER CHART, THESE • • ;? , [ i I �� I HOLES REQUIRED FOR USE WITH `�' i ' I A 1'/ie' Dia. 27 Field Power ACCESSORY PACKAGES ,- ( j B _ Supply Hol CRBTMPWROOlA00 (1/2", 3.') • t' 'i % xl§ CRBTMPWROO2A00 ('k•, 1W) .t,) ,��„ :;TTON • :A' 'A L 3 /:- 14NPTCondensate it i.i: 0' -4 - /16' B \ Drain THREADED REQUIRED 3 -S 3/16' y'•''i (115.81 J i FLUE NO30 C 'h' -14 NPT Gas Connection CONDUIT WIRE SIZE HOLE SIZES 1 ^_ I , i :. 0' -2 9/ SIZE MX •I�.; h (6 s1 TYP . (10461 L EFT SIDE ( L 3 /." Power' 1'/e' A ((28.4 ) r(1 I 1'/." Power' 1�/." 44.4 i f `lj P] 'Select either 3 /." or 1W for power, depending (t,. erg: RE WTD1313p LEO VIEW ttaE on wire size. ,,' Sr -- 5 ' 3' -1 I /2' i 2' -0 15/16" C CHONIa EEI Mir (952.51 � "- M 1/ 2' oHRovr wAy FILTERS ) [6331 (1141 I10L MIR � • ?23/4• (THROWAWAY FILTERS 1 " t i CONDENSER COIL 1 k - A Y ph COMPRESSOR ECONOMIZER MOOD �O��F I p • (' ACCESS COVER I' -4 3/8' I • CORNER 0 PAIEL li 14161 1 .i"'lI \ SEE NOTE •g 1,....--CORNER "B" : 11, 7 - { :0 . i �i r.------2 -O' -3 3/16" Z , i � I LEFT � t ( (BI) VIE A -A �« 1 L16- , � t'' SIDE I I }) �y � � I� 1 11 I I RETURN OPENING I 0 15/l6" RETURN AIR 700 0 !} '3" ;' III (2781 , + ; Iil.�- I } I VERTICAL I I ( VIEW 5 5 1: 3 -9 I _ ' j RIGHT SIDE ,� 111441 i _� 1 11.1 /1 ^, p 11; / Il` • I LLA 5AATE O °P PA D E N I / �, (657 �( +'! 2 1'I:• II 1' -B 1 /B' // ° -3; IIN BAF I ' -1/2" T I --- (76.21 Sl1PPLY -AII I 41 R 1' -5 3/4' I (512.41 / 1 I • • ../ SUPPLY AIR F O IL; :I, 1622) II SEE .i EVAPORATOR °PEKING (4511 1 ! { � I A -A // L t 0'14191/16' U9)/16 ' L I VERTICAL I I I 1( / j I1) A i :i �� / / �i IIN 91 j0'-3 6• (99 41 \� 0' 5 16' r / - 7/ 1 (( i SEE BOTTOM POWER FRONT / SUGGESTED ELECTRICAL [� 1;• CORNER '0' CHART(ELEC. ONLY/ DISCONNECT LOCATION � v �, I I� i 1, CONTROL 130x ACCESS PANEL I 0 -3 1 /t6 y, ' -0 I/I J ._0• -3 3/16 CORNER 'C' . ' 41:1. r• r V - 2' - 11 11/16' [906] 6'-I 11/16' (7B) (3061 (BU I' 1 . ,.., . ' 0' -7 1/4' • ! 6• 1C. • (16721 a (1841 K * ;U�k i 1' -S 5/16' •' -10 17/16' 0 -4 1/16' •" :%i I 2' - 55 5/16' 0' -0 3/8' 439.73 (274.6) (103.2) J) ( ' (101 ����� -� FTLTERACCESS PANEL � . j)i.- y CONTROL BOX ACCESS - �' - WIRE r - - - - (THROWAWAY FILTERS) ,' i• I; PANEL ACCESS PANEL 1 • T• : :y �� '; _ I 1----- 1----- 1 / t4 . '•! 1' -6 7/16' I I I -:1-(152.-El- 6 " I' • 1467.81 I RETURN- I MOO FILTER y ri � II. i. ' I I A I 1 OPENING 1 iR) - EVAPORATOR -FAN MOTOR 1 met- ' . AND I % 1 ZONTAL � 1 /4 BLOWER ACCESS PANEL I . 1 . I „ o -11 7 /B• t SUPPLY -AIR V 1 1 7• I / / //, [33 5.6) • 1 " I I I 0' -3 5/16• ( 301.61 OPENING 1 f1JJ. B1 , . (91.01 I 1 I OUTDOOR AIR , r OO - - J • , I I. C Milli IMII COs I• • 1 0( 2' -S 3/8' (746.21 / FORKLIFT TRUCK SLOTS 0'-6 3/4' 2' -1 • 15/ 16' �� f 0'-5 1 1 / 16' . I. BURNER ACCESS (188.01 0' -2 1 /4 "DU (146) (6'58.6) 4 (144.31 Ou 7 1 PANEL (571 OF PANEL SUPPLY AIR RETURN AIR FRONT (TIP 8 PLACES) RIGHT SIDE '' it 8 STD. CONOENSATE GRAIN ( ) are in millimeters t ,; II NOTES: millimeters. Condenser coil, 1 1. Dimensions in C Condil, for proper airflow, 36 in. one side. 12 in. the other. The side li• • Ir. getting the greater clearance is optional. +! I 2. f� Center of gravity. d. Overhead, 60 in. to assure proper condenser fan operation. • 'a i , e. Between units, control box side, 42 in. per NEC (National Electrical Code). • r ,,,.,,,,....,,����..777��� I. Between unit and ungrounded surfaces, control box side, 36 in. per NEC. ,/,.1 'i 3. 4> Direction of airflow. g. Between unit and block or concrete walls and other grounded surfaces, control box side, 42 in. per NEC. ` I I 4. On ver discharge units, ductwork to be attached to accessory roof curb only. h. Horizontal supply and return end, 0 inches. ;fu r 1, For horizontal discharge units, field- supplied flanges should be attached to hori- 6. With the exception of the clearance for the condenser coil and combustion side as I zontal discharge openings, and all ductwork should be attached to the flanges. stated in Notes 5a, b, and c, a removable fence or barricade requires no clearance. I, 1, 5. Minimum clearance (local codes or jurisdiction may prevail): 7. Units may be installed on combustible floors made from wood or Class A, B, or C a. Between unit, flue side and combustible surfaces, 36 inches. root covering material if set on baserail. . i I P b. Bottom of unit to combustible surfaces (when not using curb), 1 inch. Bottom of 8. The vertical center of gravity is 1'-6' [457) up from the bottom of the base rail. Hori- l base rail to combustible surfaces (when not using curb) 0 inches. zontal center of gravity is shown. I. Ir 1 16 I; 932 ,. - Accessory dimensions - (Calrier :II . 1 i ROOF CURB — 48TJ004 -007 . ° ! UNIT UNIT "D" ALT CONNECTOR ft i ROOF CURB "A" SIZE SIZE "B" "C" DRAIN E POWER CONTROL PACKAGE ''i ! ACCESSORY GAS I 48TJ 48TJ HOLE ACCESSORY s.3 CRRFCURB001A00 1' -2 • CRBTMPWR001A00" [356] 004 - 3 /s" NPT 3 /a" NPT 1 /2" NPT (THRU- THE - BOTTOM • '- 2' -0" 007 004 1'- 9 1' -4" 1 CONNECTIONS) 1 : I CRRFCURB002A00 [610] 007 [551] [406] [45] - • CRBTMPWR002A00' ..,•]�' • 3/4" NPT 11/4" NPT 1 /2" NPT (THRU- THE - BOTTOM ...,•;!-• • C CONNECTIONS) Q ,- _ _ -� 'Either connector package available for either roof curb. y • I s ',f C - i ``. (,-, - `; NOTES: • '41 1 i `T q 1. Roof curb accessory is shipped L �: unassembled. • 2. Insulated panels. :, " I' • �k„ / / 3. Dimensions in [ ] are in millimeters. `,� „t ?{,,0 0'_3 _ , , 0 4. Roof curb: galvanized steel. :, , �' i ( v6, 5. Attach ductwork to curb. (Flanges of duct rest • ` •q! t On Curb.) 1/4. : f - 6. Service clearance 4 ft on each side. L _ _ _ _ _ 7. * Direction of airflow. i'.d; ivcJ Er '. .I • 2 -7 5/6' (603) . s -II, �,''T.; I I SUPPL -A GASKET �' ( .,'i 1' -1 7/16' OPENING (SUPPLIED PITH CURS) • ,' (3411 i -' ..,J i, UNIT 0' -0 I/4 (71 l I .. .t ! S ` , . .. /PV NAIL .. i -'' O -O 7/16" `j TYPICAL (4) SIDES ' VI - ' 1112 "', 11) 1 • • .__I' -7 13/1 L I 1 1/S' 0' -0 7/16- j 0'[I I) ' ■� ' 4 (BOLT HEADS) (5041 C (334) 1111 �, C "' OONTER FLASHING 1 . (SOL 0 I NEAOS) p UC� PL ` (FIELD SPPL IED) . 0' -0 7/16. (76 -0 0' -0 7/16. (FIELD ?GR. \ •OOFING FELT -_ 3 (9141 (113 (FIELD 51PPLIED) OPENING FOR BASEPAN It (111 1 ' 1' A ENTRY SERVICE . ' S• •A ®DLT LEADS) (BOUT MEADS) CANT STRIP [ D' -2 v2' SECTION "C —C • b t I 3 (FIELD SVPPLIED) I64) SCALE 1,4 ROOFING MATERIAL • , L \V (FIELD SUPPLIED) ,U ' \ % /r.._ 0' -3 V4' _ _7 3n6' 2p \\\\ \\\\\\\\ 1937 (1831 , SEE NOTE •2 ii3; 0' -4 p61 3/16 . i ( �'VV • • i1 � ' ' U RIGID INSULATION y � / (FIELD SUPPLIED) ‘111- • 4 / SERVICE ' AO PLATE I' -4 13/16' 1 i' 0' -4 9/16 II / .% �[(', S AIR RETURN AIA \ / T 2 P 3 • ..-: % V IEW '..A � ... 1 LEAD OF BOLT TO SE ON 1 t INSIDE OF FLANGE � x:0 :!1t • 111. O'-I 7/13/ . 1461 \ .� 1r(2;7 - A - \ .(dr A (17 . � 05] A 4 - .. L 1 . f! I' ...... [76]- 1938) • ' MP I / VIEW - e - __ �� ♦ _ i Y (TYP. ALL CORNERS) SEE VIEW - B "�- , i 1 20 936 R As►