Loading...
Plans �.. 1 1 i 5.1 Pa ct- tu'y e,Gt� o2J 8'- 3 ,: RECEIVED I ' Corporate Plaza Roof Rafter 1 R #1 Date: 1/23/08FEB BEilik 2.2 Choice 2x 8 DF-L #2 @ 16 in. oc BASE Fb = 87¢ ',Ty or /P Conditions Repetitive Use, DL adj: 4:12 pitch, '91 NDS (� lam' Min Bearing Area R1= 0.7 in R2= 0.5 in DL Defl 0.11 in BU Data ����5� ®� Data Beam Span 11.0 ft Reaction 1 459 # Reaction 1 LL 281 # Beam Wt per ft 0 # Reaction 2 330 # Reaction 2 LL 202 # Beam Weight 0 # Maximum V 459 # Max Moment 998'# Max V (Reduced) 394 # TL Max Defl L / 240 TL Actual Defl L / 454 LL Max Defl L / 360 LL Actual Defl L / 741 Attributes Section (in Shear (in TL Dell (in) LL Defl Actual 13.14 10.88 0.29 0.18 Critical 8.62 5.41 0.55 0.37 Status OK OK OK OK Ratio 66% 50% 53% 49% Fb (psi) Fv (psi) E (psi x mil) Fcl (psi) Values Base Values 875 95 1.6 625 Base Adjusted 1389 109 1.6 625 Adjustments CF Size Factor 1.200 - Cd Duration 1.15 1.15 Cr Repetitive 1.15 Ch Shear Stress Cm Wet Use The beam self - weight was not automatically added to the loads by BeamChek. Loads Uniform TL: 54 =_A Uniform LL: 33 I Par Unif LL Par Unif TL Start End 33 H =54 0 3.5 I H I Uniform Load A R1 = 459 R2 = 330 I. SPAN = 11 FT Uniform and partial uniform loads are lbs per lineal ft. S o S TO t.t: s LK — : (: \ �. ' . �