Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
CITY TIGARD BUILDING PERMIT PERMIT #: BU i1 ° COMMUNITY DEVELOPMENT DATES ISSUED: 11/13 2008 TIGARD 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 PARCEL: 2 S 102 D B -00500 SITE ADDRESS: 08815 SW O'MARA ST ZONING: CBD SUBDIVISION: FANNO CREEK PARK LOT: JURISDICTION: TIG • • PROJECT: TIGARD SENIOR CENTER GARDEN RM Project Description: Garden room addition: REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: ADD FIRST: 564 sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 5N : sf N: N S: N E: N W: N OCCUPANCY GRP: A3 TOTAL AREA: 564 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: 38 BASEMENT: sf AREA SEP. RATED: STOR: 1 HT: 10 ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: 100 psf LEFT: ft RGHT: ft FIR SPKL: Y SMOK DET: DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : Y HNDICP ACC:Y BEDRMS: BATHS: IMP SURFACE: 564 PRO CORR: N PARKING: VALUE: $ 180,000.00 Owner: Contractor: TIGARD, CITY OF CEDAR MILL CONSTRUCTION COMPANY • 13125 SW HALL 19465 SW 89TH AVE TIGARD, OR 97223 TUALATIN, OR 97062 Phone: Contact #: PRI 503 - 885 -9370 • FAX 503 - 885 -9368 Reg #: LIC 131345 FEES Description Date Amount REQUIRED ITEMS AND REPORTS [BUPPLN] Pln Rv 9/29/2008 $562.84 [FLS] FLS Pln Rv 9/29/2008 $346.36 [BUILD] Permit Fee 9/29/2008 $865.90 [TAX] 12 %State Surch 9/29/2008. $103.91 (additional fees not listed here) • • Total $2,811.61 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 -001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. Issued By: / V Permittee Signature: OK-- Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. • S ic�s2 C z ai- o 11 A(Pc �, H - Dour -cool . Building Permit Application �� FOR OFFICE USE ONLY City of Tigard �� e I, Date/By: , b2 el, OPT Permit No.: , --anj/ 7 ° 13125 SW Hall Blvd., Tigard, OR 972 I. Plan ReviewQ „ r Other Permit: C Phone: 503.639.4171 Fax: 503.598.1960 S �� � CA`! , B • 1 � y��o T I G A R D Inspection Line: 503.639.4175 \� e �? ® to Ready/By: See Attached Checklist for Internet: www.tigard- or.gov CO `�` Notified/Method: r Supplemental Information P TYPE OF WORK REQUIRED DATA: 1- AND 2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ® Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. El 1- and 2- family dwelling ® Commercial/industrial Valuation: $ El Accessory building ❑ Multi - family Number of bedrooms: El Master builder El Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 8815 SW O'Mara St. New dwelling area: square feet City/State /ZIP: Tigard / OR / 97223 Garage /carport area: square feet Suite/bldg. /apt. no.: I Project name: Garden Room addition I Covered porch area: square feet Cross street/directions to job site: SW Hall Blvd, west on O'Mara to site Deck area: square feet Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: I Lot no.: 500 Permit fees* are based on the value of the work performed. Tax map /parcel no.: 2S102DB / 00500 Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. Addition of 564 sq. ft. on lower level, 660 sq. ft. terrace on upper level. Valuation: S$400;009 g Existing building area: 10700 square feet New building area: 564 square feet ® PROPERTY OWNER I 0 TENANT Number of stories: 1 Name: City of Tigard - Public Works Type of construction: V -N Address: 8777 SW Burnham Street Occupancy groups: City/State /ZIP: Tigard / OR / 97223 Existing: A -2 Phone: (503)718 -2590 Fax: (503)684 -7297 New: A -2 ❑ APPLICANT ® CONTACT PERSON NOTICE Business name: LRS Architects All contractors and subcontractors are required to be Contact name: Peter Dixon licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: 720 NW Davis St. jurisdiction in which work is being performed. If the City/State /ZIP: Portland / OR / 97209 applicant is exempt from licensing, the following reasons apply: Phone: (503) 221 -1121 Fax: : (503) 221 -2077 E -mail: pdixon @Irsarchitects.com CONTRACTOR -T Business name: Ce ' 11 g C ,,,c.7z,l-• (ca. BUILDING PERMIT FEES* Address: (5 SW S' th3 Ave (Please refer to fee schedule) City/State /ZIP: V Structural plan review fee (or deposit): ' �� FLS plan review fee (if applicable): Phone: i 5 03 — 9 3 - 7 o Fax: ( o — Sirs . 1 3 (o' Total fees due upon application: CCBIic c + Amount received: Authorized signature: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: P Tj XVAi Date: ci-1 t-oS Fee methodology set by Tri-County Building Industry Service Board. L I:I Building \Pennits\BUP- PernitApp.doc 03/21/06 440-4613T(I1 /02/COM/WEB) This form is recognized by most Building Departments in the Tri- County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. e BUILDING DIVISION T I G n R D TRANSMITTAL LETTER TO: DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVED DEC 0 1200s FROM: , � (( CITY OF TIGARD • COMPANY: L R,S --� 3UILDINQ D1VISVON PHONE: "")( 22 ( - (I2 ( By. Qyvu RE: ��� Ate o P 2C08 - 03 317 ( rte A dress) ermrt/Case Number) S CENTEIP--- roject name or su. • 'vision name an • of num, er ATTACHED ARE THE FOLLOWING ITEMS: Copies: I Description: I Copies: I Description: Additional set(s) of plans. Revisions: Cross section(s) and details. Wall bracing and/or lateral analysis. Floor /roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other (explain): REMARKS: • • FOR OFFICE USE ONLY Routed to Permit Tech�nic • Date: (24 I 6e Initials�� Fees Due: ❑ Yes [a' o Fee Description: Amount Due: • Special Instructions: • Reprint Permit (per PE): ❑ Yes ©4 ❑ Done Applicant Notified: Date: Initials: • (:\Building\ Forms \TransmittalLetter- Revisions.doc 4/4/07 (? g ' ©O"b1 , g$15 �✓YIQ Form.3a Project Name: Tigard Senior Center - Garden Rm. Addition Page: 1 BUILDING ENVELOPE - GENERAL Check all boxes that 1. Exceptions (Section 1312) ❑ No Envelope Components. The building plans do not call for new or altered buildi •C components, e.g., walls, floors or roof /ceilings. ❑ A Non - conditioned Building. The proposed structure has no spaces heated or cooled by S EP J. 22008 an HVAC system. IGARD IVISIO Exceptions ID Exception. All new or altered building envelope components do not comply with the cep CITY ` 1 Discussion of qualifying requirements, Section 1312, but qualify for Exception: ❑ - ❑ - IB1 1RD OC T® tI exceptions in instructions SJ tY. section. Portions of the building that qualify: Garden room addition is less than 10% (564 sq.ft. / 10,700 sq.ft. = 5.3 %) Plans /Specs Straw compliance by including The plans /specs show compliance in the following locations: shts. A201, A401, A501 a drawing sheet, detail P g number, specification section and/or subparagraph. 2. Air Leakage (Section 1312.1.1) - El Complies. Plans require penetrations in building envelope are sealed and windows and doors are caulked, gasketed or weatherstripped. The plans /specs show compliance in the following locations: Door & Window details , shts. A301, A302, spec. section 07 2500. 3. Suspended Ceiling (Section 1312.1.2.1) El Complies. Building plans do not show suspended ceilings used to separate conditioned space from unconditioned space. No exceptions permitted. 4. Recessed Light Fixtures (Section 1312.1.2.2) El Complies. The building plans do not show recessed light fixtures installed in ceilings separating conditioned spaces from unconditioned spaces. ❑ Exception. The building plans require that fixtures installed in direct contact with insulation be insulation coverage (IC) rated. The plans /specs show compliance in the following locations: sheets A701, E0.1, E2.0 • 5. Moisture Control (Section 1312.1.4) CI Complies. A one -perm vapor retarder is installed on the warm side (in winter) of all exterior floors, walls and ceilings, and a ground cover installed in the crawl space of both new and existing buildings where insulation is installed. The plans /specs show compliance in the following locations: Spec. sections 072100, 07 2500 and 07 2616. ❑ Exception. All new or altered building envelope components do not comply with the vapor retarder requirements of the code, but qualify for an exception. Note applicable exception. Section 1312.1.4, Exception: 0_ 0- Portions of the building that comply: Climate 6. Climate Zones Zones CI Zone 1 - A building site is in Climate Zone 1 if its elevation is less than 3000 feet above • sea level and it is in one of the following counties: Benton, Columbia, Clackamas, Clatsop, • Coos, Curry, Douglas, Jackson, Josephine, Lane, Lincoln, Linn, Marion, Multnomah, Polk, Tillamook, Yamhill, or Washington. ❑ Zone 2 - Building sites not in Zone 1, or where construction site elevation is 3000 feet or i f :: ` '` ' 2 ' higher in Zone 1, are in Zone 2. l 3 -1 Compliance with OSSC, effective 01/01/05 I d_ • Form 3b Project Name: Tigard Senior Center - Garden Rm. Additiot Page: 2 PRESCRIPTIVE PATH Part 1 of 4 'CLIMATE _ ZONE 1 Exterior Wall Window Area Area Maximum Glazing Fraction (total rough frame ft2) (gross ft2 Glazing ) Glazing % Complies Percent Cale- Conditioned I 2 30 I + I Space 680 I X 100 = I 33.8% I Yes elation See instruction Semi - section fora Conditioned + discussion of glazing Space X 100 = 0.0% Yes percent calculation. Conditioned Mechanical Penthouse Na + x 100 = 0.0% 1 Yes Windows Window • Max Minimum From Work - sheet 3d, place the highest (h01n W or k s h eet 3d) U- Factor Assembly Window Shading 2 Minimum n°"w °^U^^m Coefficient Assembly Overall Window U //N/A factor and highest ❑ fgf/A ❑ . Center SC. U - Value Compiles ' Yes - Or check minimum SC Complies Yes assembly and identify window. Required Minimum • • Ass embly WindowFi N/A Required Minimum Assembly N/A • • Required Mini -mum • Assembly (Operable N/A Windows and Curtalnwall) • • The plans/specs show window compliance in the following locations: 'Spec. section "08 5400 Composite Windows ", Window types sheet A203, Ext. Elevations sheet A401. Notes 'from Worksheet 3d, place the highest Overall Window U- factor or check (Minimum Assembly). See 'Window Requirements' in table on the followin I requirements. Excel version will automatically insert minimum assembly 9 page for specific MA ly requirements or greatest U -value from Worksheet 3d. 2 From Worksheet 3d, place the highest 'center-of-glass' shading coefficient (SC) for glass or check MA (Minimum Assembly). See 'Window Require - menu' in following table for specific MA requirements. Excel version will automatically insert minimum assembly requirements or greatest SC from Worksheet 3d. Shading Coefficient (SC) can be calculated from Solar Heat Gain Coefficient using the equation: SC = SHGC + 0.87. Manufacturers data may also be used to document SC. Walls Wall / Insulation Type I nsulation 0 instructions for Only U - Facto See instructions a discussion of wall Frame (wood or metal framing) • require meets. J 19 or J Or • J or J Or . J or • J Or Below -Grade Walls R -Value See instructions for a Insulation Only U - Factor discussion of Below - Grade Walls (MM. R -7.5) (Max. n 071) requirements. In /a I - I 5 Notes 3 Submit Worksheet 3a for each calculated assembly U- factor v+' - 3 -2 Compliance with OSSC, effective 01/01/05 I Project Name: Tigard Senior Center - Garden Rm. Addition Page: 3 i Form 3b Part 2 of 4 PRESCRIPTIVE PATH Code Requirements - Zone i Discussion of these requirements in the instruction section. ZONE 1 Wall Requirements Window Requirements Max. Shading Max. Glazing R -Value Wall I Insulation Type Insulation Only U- Factor Max. U- Factor Coefficient Fraction's nsu yp w 0 CMU'Masonry w/integral loose fill insulation WA 0.540' 0.57' Up to 15% 1.4 or 0.300 Masonry or concrete w /coot. exterior insu CMU Masonry w /integral rigid fill insulation N/A or 0.210 Masonry or concrete v./interior insulation 11 o 0 or 0.130 0 7 Masonry or concrete w /cunt. exterior insulation 2.8 0.540 0.57' Up to 30% 13 or 0.130 Frame (wood or metal framing) Other (provide short description) 13 or 0.130 or 0.210 CMU Masonry, wfintegral rigid fill N/A insulation Or 0.130 Masonry or concrete wfinterior insulation 11 or 0.210 0.37010 0.3570 Up to 40% Masonry or concrete w /cOflt exterior insulation 2.8 or 0.210 Frame (wood or metal framing) 13 Other (provide short description) 13 or 0.130 Code Requirements - Zone 2 Discussion of these requirements in the instruction section. ZONE 2 Wall Requirements Window Requirements Wall / Insulation Type Max. Shading R -Value U- Factor Max U-Factor Coefficient Max. Glazing Insulation Only Fradion o r 0300 11 ,+ CMU'Masonry wrintegral loose figs insulation N/A 0,500 0.57 Up to 15% 1.8 or 0.270 Masonry or concrete w/cont. exterior insula or 0.160 CMU Masonry w/integral rigid fill insulation N/A or 0.090 Masonry or concrete wfinterior insulation 13 Up to 25% or 0 • M or concrete w/cont. exterior insulation - 4.3 0.500 ++ 0.57 Frame (wood or metal framing) 19 or 0.090 Other (provide short description) 19 or 0.090 or 0.160 CMU Masonry' wM N/A tegral rigid fill insulation or 0.090 Masonry or concrete wfinterior insulation 13 Up to 33% Masonry or concrete w /cont exterior insulation 4.3 or 0.160 0.37012 0.4312 . Frame (wood or metal framing) 19 a 0.090 Other (provide short description) 19 or 0.090 Notes 4 The Simplified Trade -off Approach must be used if glazing fraction exceeds allowable percentages. 5 Minimum weight of masonry and concrete ,calls = 45 Ibth2 of wall face area 6 All cores to be filled. At least 50% of cores must be filed with vermiculite or equivalent fill insulation. 7 Prescriptive MA (Minimum Assembly) - For Fixed Windows: double - glazed window with a 0.5 inch air space, low-e coating and aluminum frame. MA shading coefficient description is a tinted outboard pane of glass. For Operable Windows or Curtainwall: double - glazed window with a 0.5 inch air space, low-e coating and thermally broken frame. MA shading coefficient description is a tinted outboard pane of glass. e All cores except bond beams must contain rigid insulation inserts approved for use in reinforced masonry walls 9 Batt insulation installed in metal or wood frame walls shall be insulated to the full depth of the cavity, up to 6 inches in depth. 171 Prescriptive MA (Minimum Assembly) - For Fixed Windows: double-glazed window with a 0.5 inch argon filled space, low-e coating (e <= 0.05) and thermal break frame. For Operable Windows or Curtainwall: only use Max U- Factor. MA shading coefficient description is a 0.25 -inch thick glass with low-e coating (e <= 0.05) with a tinted outboard pane. + Prescriptive MA (Minimum Assembly) - For Fixed Windows: double -glazed window with a 0.5 inch air space, low-e coating and aluminum frame. For Operable Windows or Curtainwall: double - glazed window with a 0.5 inch air space, low-e coating (e <= 0.1) and thermally broken frame. MA maximum shading coefficient description is a tinted outboard pane of glass. 12 Prescriptive MA (Minimum Assembly) - For Fixed Windows, a double- glazed window with a 0.5 inch argon filled space, low-e coating (e <= 0.05) and thermal break frame. For 40007.4°,,> !•. Operable Windows or Curtalnwall, only use Max U-Factor. MA shading coefficient description is a 0.25 -inch thick glass with low-e coating (e <= 0.05). 3 - 3 Compliance with OSSC. effective 01/01105 v +L • Form 3b Project Name: Tigard Senior Center - Garden Rm. Addition Page: 4 PRESCRIPTIVE PA TH Part 3 of 4 Roofs/ R -Value Ceilings • • See i ru fora Roof / Ceiling" In ( M n R -19) (Max. 0.ly U - Factor" • 050) dicussion of TJI framing roofs/ceilings. 9. plywood sheathing, built-up roofing 25 or • Notes 71 Write -in a short description for assembly with the lowest Insulation R -value or the highest assembly U- factor. 12 Submit Worksheet 3b for each calculated roof /ceiling assembly U- factor. Skylight Area Roof Area Skylight % Maximum Skylight (total rough frame R2) (gross ft2) 1 3 Fraction Complies • Skylights Conditioned Includes glazed l smoke vents. Spate N/A I + X 100 = I I N/A See instructions for a Semi - • dicussion of skylights. Conditioned + X 100 = I Space pN /A Conditioned Mechanical + X 100 = N/A Penthouse Skylight Area (total rough frame Roof/Ceiling Area Skylight ft2) (gross (12) Percent" Skylights From Worksheet 3d, Skylights Max > Minimum place highest Overall (from Worksheet 3d) U- Factor" Assembly Skylights Shading Minimum thomWorksheet 3d) Coefficient' Assembly Vertical Window U- factor and highest #N/A - ❑ #N/A - N/A Center-of -Glass SC. • U -Value Complies Yes SC Complies Yes • Required Minimum Assembly N/A , Required Minimum Assembly N/A (must use SC) The plans/specs show window compliance in the following locations: • Code Thermal Performance Require- Compliance Option Shading Coefficient Q Overall Vertical U Factor Center of Glass SC meats Performance U -1.230 for overall assembly in overhead plane SC -0.47 center-of-glass Min. Assembly (MA) Double glazed, 0.5 -Inch airspace N/A • Notes . 13 Skylight percentage area is based on total skylight and smoke vent rough frame area divided by total conditioned roof area. Percentage must not exceed 6 percent of total roof /ceiling area in conditioned building space. The Simplified Trade-off Approach must be used if glazing fraction exceeds allowable percentages. 14 From Worksheet 3d, place the highest Overall Vertical U -factor or write -in MA (Minimum Assembly). See - Skylight Requirements' in table above for specific MA requirements. is From Worksheet 3e, place the highest'centerof- glass' shading coefficient (SC) for glass. See 'Skylight Requirements' in table above for specific MA requirements. Shading Coefficient (SC) can be calculated from the Solar Heat Gain Coefficient using the equation: SC = SHGC + 0.87. Manufacturers data may also be used to document SC. r ir • fr 3 Compliance with OSSC, effective 01/01/05 • • j 1 . Form 3b Project Name:ITigard Senior Center - Garden Rm. Addition I Page: 5 PRESCRIPTIVE PATH Part 4 of 4 • • Floors - loors R -Value a a di ins cuss ion of for Floors over Unconditioned Spaces" Insulation Only U- Factor di ion of I floors. IN /A I I Or I • Heated Concrete Slab Edge R -Value Insulation Only I I I Heated Slab -on -Grade (Section 1312.1.2.4) O Complies. Building plans show insulation extending downward from the top of the slab a minimum distance of 24 inches or downward and under the slab for a combined minimum distance of 24 inches or to the bottom of the thickened edge of the of slabs used as a foundation. • The plans /specs show compliance in the following locations: sheet A501. Notes 1B Write -in a short description for assembly with the lowest insulation R -value or the highest assembly U- factor. 17 Submit Worksheet 3c for each calculated floor assembly U- factor. 1e Write -in a short description for Heated Slab, which has heat. integrated into slab such as hydronic heat. If more than one floor type. enter the lowest insulation R -value ar the highest component U- factor of any floor. • . Compliance Options Code . Min. R- Value' . Require- Component Insulation Only • Max. U- Factor ments I » I. I 0.070 Floor over Unconditioned Spaces Climate Climate I Cmponent ' Zone 1 Zone 2 Heated Concrete Slab Edge, Min. R -Value 1 7 . 5 I or 1 10.0 Doors R -Value U- Factor See i sion of doors. for a Doors" Insulation Only Center-of-Panel opaque, with leaf width greater than 4 dicussion of do (Mm. R -5) (Max. 0.20) 4' I I w I I Notes 19 Write -in a short description for Doors. If more than one door type, enter the lowest insulation R -value or the highest center -of -panel U- factor of any door. The following doors are exempt from door and window U- factor and shading coefficient requirement . rA "Vi - 3 -5 Compliance with OSSC. effective 01/01/05 Form 4a Project Name: Tigard Senior Center Garden Rm Page: 1 SYSTEMS - GENERAL Applicability Plans/ Specs Discussion of qualifying Show compliance by including a drawing sheet, detail exceptions on page 4 -25 number, specification section and subparagraph. 1. Applicablity (Section 1317) Is this form required? El Form Required. Complete form if a new HVAC system is being installed, or components of an existing HVAC system are being replaced (I.e., equipment, controls, ductwork, and insulation.) ❑ Exception. The building or part of the building qualifies for an exception from HVAC code requirements. Applicable code exception is Section 1317.1. Portions of the building that qualify: Area: Exception 0-1 0-2 0-3 Area: Exception 0-1 0 -2 0-3 Area: Exception ❑ -1 0-2 0 -3 ❑ Form Not Required. This project does not contain work required to comply with code. 2. Simple or Complex Systems (Section 1317.9 or 1317.10) o Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and equipment efficiency worksheets as required. Form 4b is not required. ❑ Complex System. Project includes a Complex System. Complete this form (4a), form 4b and equipment efficiency worksheets as required. 3. Equipment Performance (Section 1317.5) ❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment, or heat - operated cooling equipment. El Complies. All new HVAC equipment have efficiencies not less than those required by code. The following equipment efficiency worksheets are attached: ❑ 4a ❑ -4b o -4c ❑ -4d ❑ -4e ❑ -4f ❑ -4g ❑ -4h ❑ -4i ❑ -4j 4. Duct Insulation and Sealing (Sections 1317.7 8s 1317.8) ❑ No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. o Complies. The plans and specifications call for all air - handling ducts and plenums to be insulated and sealed as required by Sections 1317.7 &1317.8. 5. Distribution Transformers (Section 1316.1) ❑ No Distribution Transformers. The plans /specs do not call for new distribution transformers. ❑ Complies. All new distribution transformers comply with efficiency, testing, and labeling requirements of Section 1316.1.1. ❑ Exception. The project qualifies for an exception per Section 1316.1.1, Exceptiion: 0-1 0 -2 0-3 0-4,0-5 0-6 0-7 ❑-e ❑ -s 0-10 ❑ -1 ❑'12 ❑ -13 ❑ -14 Attach relevant documentation for appropriate exception. The plans /specs show compliance in the following locations: • 4 -1 Compliance with OSSC, effective 04/01/07 Form 4a Project Name: Tigard Senior Center Garden Rm Add Page: 2 SYSTEMS - GENERAL 6. HVAC Controls (Section 1317.4) 6.1 System Thermostat /Zone Controls (Section 1317.4.1) 0 Complies. All new HVAC systems include at least one temperature control device responding to temperatures within the zones. ❑ Exception. HVAC system qualifies for an exception from zone control requirements. The applicable code exception is Section 1317.4.2, Exception 0-1 0-2 Portions of the building that qualify: The plans /specs show compliance in the following locations: HVAC Plan, Sheet M2.01. 6.2 Off - hour Controls - Auto Setback or Shutdown (Section 1317.4.3) 0 Complies. Systems must have at least one of the following features: o Control Setback Complies. Each system is equipped with automatic control capable of reducing energy through control setback during periods of non -use or alternate use of spaces O Equipment Shutdown Complies. Each system is equipped with controls capable of reducing energy use through automatic shutdown during periods of non -use or alternate use of spaces. HVAC systems with equipment shutdown are equipped with at least one of the following: o Programmable controls (1317.4.3.1 (1)) ❑ Occupant sensor (1317.4.3.1 (2)) ❑ Interlocked to a security system (1317.4.3.1 (3)) ❑ Manually activated timers with 2 -hour operation max (1317.4.3.1 (4)) O Exception. The building qualifies for an exception to the requirement for automatic setback or shutdown controls. The applicable code exception is Section 1317.4.3 Exception 0-1 0-2 The plans /specs show compliance in the following locations: Fan Coil Schedule, Sheet M0.02. 6.3 Control Capabilities (Sec. 1317.4.2.1) 0 Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. ❑ Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section 1317.4.2.1 Exception 0-1 0-2 Portions of the building that qualify: The plans /specs show compliance in the following locations: Fan Coil Schedule, Sheet M0.02; Specification Section 23 5400. 6.4 Optimum Start Controls (Section 1317.4.3.2) ❑ Complies. Separate HVAC systems have controls capable of varying start-up time of system to just meet temperature set point at time of occupancy. El Exception. HVAC systems have a design supply air capacity not exceeding 10,000 cfm. The plans /specs show compliance in the following locations: Fan Coil Schedule, Sheet M0.02. 6.5 Heat Pump Controls (Section 1317.4.4) ❑ No Heat Pump. The plans /specs do not call for a new heat pump 1 Complies. All new heat pumps equipped with supplementary heaters are controlled to minimize the use of supplemental heat as defined in Section 1317.4.4. ,.�.. • The plans /specs show compliance in the following locations: .amFfJ,:a Fan Coil Schedule, Sheet M0.02; Specification Section 23 5400. 4 -2 Compliance with OSSC, effective 04/01/07 Form 4a Project Name: Tigard Senior Center Garden Rm Add ' Page: 3 SYSTEMS - GENERAL 7. Economizer Cooling (Section 1317.3) ❑ No Cooling. The building plans do not call for a new fan system with mechanical cooling. ❑ Complies. Each new fan system has an air economizer capable of modulating outside -air and return -air dampers to provide up to 100 percent of the design supply air as outside air. El Exception At least one new fan system qualifies for an exception. The applicable code exception is Section 1317.3, Exception ❑ , ❑ - 0 -3 0-4 0-5 0-6 0-7 If Exception 3 is selected complete the following: (a) Total cooling capacity of exempt units (Btu /hr) 18,000 (b) Total installed building cooling capacity (Btu /hr) 237,400 (Total with existing) El Complies. Sum of exempt units rated at less than 54,000 Btu /hr is <240,000 Btu /hr or a/b Unit Identifier of exempt units: The plans /specs show compliance in the following locations: 8. Economizer Pressure Relief as Integration (Section 1317.3.1 and 1317.3.2) o No Economizers Required. Project does not contain a new fan system requiring economizers. ❑ Overpressurization Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will relieve the extra air introduced by the economizer. ❑ Integration Complies. Economizer is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. ❑ Exception. The applicable exception is Section 1317.3.2, Exception 0-1 0-2 The plans /specs show compliance in the following locations: • 9. Hot Gas Bypass (Section 1317.5) o No Hot Gas Bypass ❑ Complies. See allowable amount of hot gas bypass as a percentage of total cooling capacity in table below. Unit ID Rated Cooling Capacity Hot Gas Bypass Capacity Allowable Hot Gas Bypass ~ Rated Cooling Capacity g Ca aci Max Hot Gas Bypass <240,000 Btu /hr 50% >240,000 Btu /hr 25% ❑ Exception. Unitary packaged system with cooling capacity no greater than 90,000 Btu /h 4 -3 Compliance with OSSC, effective 04 /01/07 For m 4a Project Name: Tigard Senior Center Garden Rm Add Page:l 4 I . SYSTEMS GENERAI mmimmmmm i mmmommiimmonomm o 10. Shutoff Dampers (1317.4.3.3) ❑ Not Required. Shutoff dampers are not required on this project. o Complies. Each outdoor air supply & exhaust system shall be equipped with motorized dampers. ❑ Exception. The building qualifies for an exception to the motorized damper requirement. The applicable code exception is Section 1317.4.3.3 Exception 0- 0-2 0 -3 0-4 ❑ -s 0-6 The plans /specs show compliance in the following locations: HVAC Plan, Sheet M2.01 10.1. Shutoff Damper Controls (Section 1317.4.3.3.1) o Complies. Outdoor air supply and exhaust systems shall be provided dampers that automatically shut when systems or spaces served are not in use or during building warm -up, cooldown, or setback. ❑ Complies. Stair and shaft vents are capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. The plans /specs show compliance in the following locations: Sequence of Operation, Sheet M4.01 10.2. Motorized Damper Leakage (1317.4.3.3.2) El Complies. Motorized outdoor air supply and exhaust air dampers have a maximum leakage rate of 4 cfm /ft2 at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. ❑ Exception. Packaged HVAC equipment may have maximum leakage rate of 20 cfm /ft at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. The plans /specs show compliance in the following locations: Notes, Sheet M0.01 11. Piping Insulation (Section 1314) El No New Piping. The building plans and specifications do not call for new piping serving a heating or cooling system or part of a circulating service water heating system. ❑ Complies. All new piping serving a heating or cooling system or part of a circulating service water heating system complies with the requirements of the Code, Section 1314.1. ❑ Exception. New piping qualifies for exception: Section 1314.1, Exception 0- 0 -2 12. Occupancy Ventilation El Complies. Mechanical ventilation systems provide the required amount of ventilation is indicated in plans /specifications as specified in Chapter 4 of the Oregon Mechanical Specialty Code. ❑ Complies. Natural ventilation systems provide required amount of ventilation as certified by a reg- istered architect or engineer as specified by Section1203.4.1, Exception. Attach worksheet 4m. The plans /specs show compliance in Ventilation Schedule, Sheet M0.02. the following locations: The plans /specs show compliance on ,,F ":. , the following pages: • 4-4 Compliance with OSSC, effective 04/01/07 Form 4a Project Name: Tigard Senior Center Garden Rm Add Page: 5 SYSTEMS - GENERAL 13. High Occupancy Ventilation (Section 1317.2.2) ❑ Complies. HVAC systems with ventilation air capacities of 1,500 CFM or greater that serve areas having an average occupant load of 20 square feet per person or less from Table 1004.1.2 have a means to automatically reduce outside air intake. Identify applicable systems: Plans /specs indicate where equipment (i.e. carbon dioxide sensor) and sequence is specified: ❑ Exception. HVAC systems are equipped with an energy recovery device with at least 50% recovery effectiveness. El No High Occupancy Systems. Project does not contain an HVAC system as described above. 14. Exhaust Air Heat Recovery (Section 1318.3) 0 Not Regulated. HVAC system does not have: 1) design supply air cap. of >10,000 cfm, and 2) min. outside air supply >70 %, and 3) at least 1 exhaust fan rated at 75% of min outside air ❑ Complies. Heat recovery system increases outside air temperature by 20 °F (Climte Zone 1) or 30 °F (Zone 2) and has provision to provide bypass during air economizer mode. ❑ Exception. An HVAC system qualifies for an exception to this requirement. Applicable exception from Section 1318.3:Exmptkn -3 0-4 0-5 0-6 0-7 The plans /specs show compliance in the following locations: 15. Large Volume Fan Systems (Section 1318.4.2.4) El Not Regulated. The building plans or specifications do not call for fan systems over 15,000 CFM that serve a single zone and function for the purpose of temperature control. ❑ Complies. Fan systems are equipped with variable frequency drive or two speed motor to reduce airflow as required by Section 1318.4.2.3. The plans /specs show compliance in the following locations: 16. Variable Speed Drives (Section 1317.10.3.1) Not Regulated. The building plans or specifications do not call for fan and pump motors 10 horsepower and greater that serve variable -flow air or liquid systems. ❑ Complies. All fan and pump motors 10 hp and greater which serve variable -flow air or liquid systems are controlled by a variable -speed drive. ❑ Exception. The building qualifies for an exception to the variable -speed drive requirement. Portions of the building that qualify: Applicable code exception is Section 1317.10.3.1, Exception The plans /specs show compliance in the following locations: • 17. Service Water Heating (Sec. 1315) ❑ No New Water Heating. The building plans and specifications do not call for new water heaters, hot water storage tanks or service hot water distribution systems. • Complies. All new water heaters, hot water storage tanks or'service hot water distribution systems comply with the requirements of the Section 1315. ❑ Exception. The applicable code exception is Section: Exception: Portions of the building that qualify: The plans /specs show compliance in the following locations: • 4 -5 Compliance with OSSC, effective 04 /01/07 . Form 4a Project Name: Tigard Senior Center Garden Rm Add Page:l 6 I SYSTEMS - GENERAL 18. Swimming Pools, Spas and Hot Tubs (Section 1315.5) o No New Pools. The building plans and specifications do not call for new, swimming pools, spas or hot tubs. D OnlOff Controls Complies. Spa and hot tub heaters are equipped with a readily accessible ON /OFF switch as required by Section 1315.5.1. ❑ Ventilation Controls Complies. Pool ventilation system is controlled based on humidity. ❑ Cover Complies. All heated pools, hot tubs and spas are equipped with a cover. O Heat Recovery Complies. Pools, Spas, and hot tubs, over 200 ft utilize recovered heat as required by Section 1315.5.3. ❑ Exception.. Heat recovery is not necessary as pool is heated by renewable energy or waste heat recovery sources capable of providing at least 70 percent of the heating energy required over an operating season. 19. Fume Hoods (Section 1317.2.1.) O No Fume Hoods. The building plans do not call for fume hood systems that have a total exhaust rate greater than 15,000 cfm. ❑ Complies. Fume hood systems have at least one of the following features: O Variable air volume hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50% or less of design values. ❑ Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no warmer than 2° F below room set point, cooled no cooler than 3° F above room set point, no humidification added, and no simultaneous heating and cooling used for dehumidification control. O Heat•recovery systems to precondition makeup air from fume hood exhaust in accordance with 1318.3 - Exhaust Air Energy Recovery, without using any exception. The plans /specs show compliance in the following locations: 20. Parking Garage Ventilation (Section 1317.2.3) • El No Enclosed Garages. The building plans and specifications do not call for enclosed Group S -2 parking garages with a ventilation exhaust rate greater than 30,000 CFM. ❑ Complies. The plans and specifications call for carbon monoxide sensing devices as required by Section 1317.2.3. • ❑ Exception. Open parking garages. 21. Kitchen Hoods (Section 1317.11) O Not Regulated. The plans /specs do not call for any new kitchen hoods with exhaust capacity greater than 5,000 cfm each. ❑ Complies. All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm have at least 50 percent of the required makeup air; (a) unheated or heated to no more than 60 °F; and (b) uncooled or evaporatively cooled. ig) .- The plans /specs show compliance in the following locations: 22. Outside Heating Systems (Section 1317.12) . 0 No Outside Heating Systems. The plans /specs do not call for new permanently installed heating systems outside the building. 0 Complies. All new permanently installed outside heating systems are radiant gas fired systems controlled by an occupancy sensor or timer switch as required by Section 1317.12. 4 -6 Compliance with OSSC, effective 04/01107 Worksheet 4c Project Name: Tigard Senior Center Garden Rm Add Page: 7 UNITARY HEAT PUMP - AIR COOLED Equipment (a) (b) (c) (d) (e) (f) (g) Proposed Rating Proposed Heating Rating Discussion of equip- ment ratings and Cooling Compliance equipment definitions Capacity COP COP Schedule New or on page 4 -19. Equip. ID Model Designation (Btu/h) SEER EER HSPF (47°F) (17°F) (A -E) Replacmnt' HP1 Carrier 25HPA5 -18 18,000 15.5 12.5 8.3 3.68 2.38 B New • Required Indicate source of information Document- ❑ ARI Unitary Directory, Section AC, page: ation ❑ ARI Applied Products directory, Section ULE, Page: 0 Product data (Attach data furnished by the equipment supplier, I.e., "cut sheets °) Code • Cooling Capacity Minimum Cooling - Re aired (btu/hr) Rating Minimum Heating Rating q Compliance But not or Part COP COP Efficiencies Schedule Equipment Type Over over EER Load HSPF (@ 47°F) (@ 17°F) New' 0 65,000 - 13 SEER 7.7 - - • Single Package Without a Replcmnt' 0 65,000 - 9.7 SEER 6.6 - - A Heating Section or With 65,000 135,000 10.1 n/a 3.2 2.2 This schedule of Electric Resistance Heat • equipment efficien- All 135,000 240,000 9.3 n/a 2.0 3.1 cies was reformat- 240,000 - 9.0 9.2 IPLV - 3.1 2.0 ted from the code, Table 13-m. New' 0 65,000 13 SEER 7.7 Split System Without a Replcmnt' 0 65,000 - 10 SEER 6.8 B Heating Section or With 65,000 `135,000 10.1 n/a - 3.2 2.2 Electric Resistance Heat All 135,000 240,000 9.3 n/a - 3.1 2.0 240,000 - 9.0 9.2 IPLV - 3.1 2.0 New' 0 65,000 - 13 SEER 7.7 - - Single Package With a Replcmnt' 0 65,000 - 9.7 SEER 6.6 - - C Heating Section Other Than 65,000 135,000 9.9 n/a - 3.2 2.2 Electric Resistance All 135,000 240,000 9.1 n/a - 3.1 2.0 ' ' ' 240,000 - 8.8 9.0 IPLV - 3.1 2.0 I" New' 0 65,000 - 13 SEER 7.7 Split System With a Heating Replcmnt" 0 65,000 - 10 SEER 6.8 D - - Section Other Than Electric 65,000 135,000 9.9 n/a a . 3.2 2.2 Resistance All 135,000 240,000 9.1 n/a - 3.1 2.0 240,000 - _ 8.8 9.0 IPLV - 3.1 2.0 E.uipment is new Installation or replaces existing equipment • 4 -13 • Compliance with OSSC, effective 04 /01/07 COMBINATION RATINGS ARI STANDARD RATINGSt COOLING HEATING UNIT SIZE - INDOOR MODEL COOLING HIGH TEMP LOW TEMP SERIES CAPACITY FACTORY STANDARD SEER FURNACE MODEL EER E E N N HSPF ENHANCE RATING TOR CAPACITY COP CAPACITY COP •FX4CNF018 17,800 TDR &TXV 15.00 12.00 18,000 3.82 10,400 2.34 8.2 FE4ANFOO2 18,000 TDR &TXV 15.50 12.50 17,800 3.68 10,300 2.38 8.3 FF1ENP018 17,400 TDR &1XV 13.20 10.90 18,000 3.40 10,800 2.22 7.9 FF1ENP024 17,700 TDR &TXV 13.50 11.10 18,000 3.48 10,900 2.24 8.0 FV4BNFOO2 18,000 TDR &TXV 15.50 12.50 17,800 3.66 10,300 2.38 8.3 FX4CNF024 18,000 TDR &TXV 15.00 12.40 18,000 3.66 10,400 2.38 8.3 FY4ANF018 17,400 TDR &TXV 13.00 10.80 18,000 3.40 10,800 2.20 8.0 FY4ANF024 17,600 TDR &TXV 13.20 10.90 18,000 3.40 10,900 2.22 8.0 CAP••1814A•• 17,300 TDR &TXV 14.50 12.00 17.400 3.38 10,100 2.26 7.8 ' 58CV(A,X)070 -12 CAP••1814A•• 17,400 TXV 13.00 10.80 18,000 3.38 10,800 2.20 7.8 CAP••2414A•• 17,600 TDR &TXV 15.00 12.00 17,600 3.52 10,200 2.32 8.0 58CV(A,X)070 -12 CAP••2414A 17,800 TXV 13.50 11.00 18,000 3.50 10,900 2.26 8.0 CAP**2417A** 17,700 TDR &TXV 15.00 12.00 17,600 3.56 10,200 2.34 8.1 58CV(A,X)090 -16 CAP**2417A** 17,700 TDR &1'XV 15.00 12.00 17,600 3.54 10,200 2.34 8.1 58MV8060 -14 Lt) CAP**2417A** 17,800 TXV 13.50 11.00 18,000 3.50 10,900 2.26 8.0 Q • CL = CNPF•2418A I 17,700 I TXV I I 13.50 I 10.80 I 18,000 I 3.54 I 10,900 I 2.28 I 8.1 Ln N CNPH*2417A** 17,600 TDR &TXV 15.00 12.00 17,600 3.56 10,300 2.34 8.1 58CV(AX)070-12 18 -30 CNPH*2417A** 17,700 TDR &TXV 15.00 12.00 17,600 3.60 10,300 2.34 8.2 58CV(A,X)090 -16 CNPH•2417A 17,600 TDR &TXV 14.50 12.00 17,600 3.58 10200 2.34 82 58MVB040 -14 CNPH•2417A•• 17,600 TDR &TXV 15.00 12.00 17,600 3.58 10,300 2.34 8.2 58MVB060 -14 CNPH•2417A 17,700 1DR &TXV 15.00 12.00 17,600 3.60 10,300 2.34 8.2 58MVB080-14 CNPH•2417A•• 17,700 TXV 13.50 10.80 18,000 3.54 10,900 2.28 8.1 CNPV*1814A** 17,300 TDR &TXV 15.00 12.00 17,400 3.50 10,200 2.30 8.0 56CV(A,X)070 -12 CNPV•1814A•• 17,400 TXV 13.00 10.80 18,000 3.50 10,900 2.26 8.0 CNPV•2414A•• 17,600 TDR &TXV 15.00 12.00 17,600 3.56 10,300 2.34. 8.1 56CV(A,X)070 -12 CNPV•2414A•• 17,700 TXV 13.50 10.80 18,000 3.54 10,900 2.28 8.1 CNPV•2417A•• 17,700 1DR &TXV 15.00 12.00 17,600 3.60 10,300 2.34 8.2 58CV(A,X)090 -16 CNPV•2417A• 17,700 TDR &TXV 15.00 12.00 17,600 3.58 10,300 2.34 8.2 58MVB060 -14 CNPV•2417A•• 17,700 TXV 13.50 10.80 18,000 3.54 10,900 2.28 8.1 CSPH*2412A** 17,600 TDR &TXV 15.00 12.00 17,600 3.54 10,300 2.34 8.1 58CV(A)0070 -12 CSPH*2412A** 17,700 TDR &TXV 15.00 12.00 17,600 3.58 10,300 2.34 8.2 58CV(A,X)090 -18 CSPH•2412A•• 17,600 TDR &TXV 14.50 12.00 17,600 3.58 10,300 2.34 8.2 58MVB040 -14 CSPH*2412A** 17,600 TDR &TXV 15.00 12.00 17,600 3.56 10,300 2.34 8.1 58MV8080 -14 CSP1-1•2412A 17,700 TDR &TXV 15.00 12.00 17,600 3.58 10,300 2.34 8.2 58MVB080 -14 CSPH*2412A** 17,700 TXV 13.50 10.80 18,000 3.54 _ 11,000 2.28 8.1 •FX4CNF030 23,600 TDR &TXV 15.50 12.50 23,800 3.78 14,000 2.52 8.5 FE4ANFOO2 23,400 TDR &TXV 15.50 12.50 23,400 3.72 13,800 2.50 8.5 FE4ANF003 23,400 TDR &TXV 16.00 13.00 23,400 3.72 13,700 2.52 8.5 FF1ENP024 23,000 TDR &TXV 13.50 11.20 24,000 3.48 14,600 2.34 8.1 FF1ENP030 23,000 TDR &TXV 13.50 11.20 24,000 3.50 14,500 2.34 8.1 FV4BNFOO2 23,400 TDR &TXV 15.50 12.50 23,400 3.72 13,800 2.50 8.5 FV4BNF003 23,400 TDR &TXV 16.00 13.00 23,400 3.72 13,700 2.52 8.5 FX4CNF024 23,200 TDR &TXV 15.00 12.40 23,600 3.68 14,000 2.48 8.4 FY4ANF024 22,800 TDR &TXV 13.50 11.40 24,000 3.48 14,400 2.34 8.0 FY4ANF030 23,000 TDR &TXV 14.00 11.50 24,000 3.58 14,500 2.38 8.2 CAP••2414A•• 22,800 TDR &1'XV 15.00 12.50 23,200 3.56 13,700 2.44 8.2 58CV(A,X)070 -12 1AP••2414A•• 23,000 TXV 14.00 11.20 24,000 3.54 14,600 2.38 8.2 24 -30 CAP**2417A** 23,000 TDR &TXV 15.50 12.50 23,200 3.60 13,700 2.48 8.3 58CV(A)Q090 -16 CAP**2417A** 23,000 TDR &TXV 15.00 12.50 23,200 3.58 13,700 2.44 8.2 58MVB060 -14 CAP**2417A" 23,000 TXV 14.00 11.20 24,000 3.54 14,600 2.36 8.2 CAP••3014A 23,200 TDR &1'XV 15.50 12.50 23,200 3.58 13,700 2.46 8.2 58CV(A,X)070 -12 CAP••3014A•• 23,200 TXV 14.00 11.50 24,000 3.56 14,600 2.38 8.2 CAP••3017A•• 23,200 1DR &TXV 15.50 12.50 23,200 3.64 13,700 2.48 8.3 58CV(A,X)090 -16 CAP••3017A 23,200 TDR &TXV 15.50 12.50 23,200 3.62 13,700 2.48 8.3 58MVB060 -14 CAP••3017A• 23,200 TXV 14.00 11.50 24,000 3.56 14,600 2.38 8.2 CNPF*2418A** I 23,000 I TXV I I 13.50 I 11.20 I 24,000 I 3.60 I 14,600 I 2.38 I 8.3 I CNPH*2417A" 22,800 TDR &TXV 15.00 12.50 23,200 3.60 13,800 2.44 8.3 58CV(A,X)070 -12 CNPH•2417A•• 23,000 TDR &TXV 15.00 12.50 23,200 _ 3.64 13.800 2.46 8.3 58CV(A,X)090 -16 CNPH•2417A• 23.000 TDR &TXV 15.00 12.50 23,200 3.64 13,800 2.46 8.3 58CV(A,X)110 -20 CNPH•2417A•• 23,000 TDR &TXV 15.00 12.50 23,200 3.64 13,800 2.46 8.3 58CV(A,X)155-22 CNPH , •2417A•• 23,000 TDR &TXV 15.00 . See notes on pg. 17 . 10 CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP200B -00317 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/13/2008 Phone: (503) 639- 4171�.F�l'• Inspection Requests (24 Hrs.): (503) 639 -4175 F.!.. INSPECTION WORKSHEET FOR DATE: 2/25/20 TIME: 7 :00AM PAGE: 9 SITE ADDRESS: 08816 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY PHONE #: 503 -886 -9370 • Inspection Request Scheduled For: Date: 2/25/2009 Pour Time: Code # Inspection Description Confirm # Contact # Message 299 Final inspection 080838-01 503 332.6458 N Corrections/Comments/Instructions: 4 PAS . r PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS • FAIL ►/ *ALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: _ Date: J O , Phone #: (503) 718 - f l a . CITY OF TIGARD i BUILDING DIVISION PERMIT #: 1BUP2008 -00317 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/1312008 Phone: (503) 639- 4171 y I Inspection Requests (24 Hrs.): (503) 639 -4175 `__- INSPECTION WORKSHEET FOR DATE: 212Q12009 TIME: 7 :00AM PAGE: 20 SITE ADDRESS: 06815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition, OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY PHONE #: 503 Inspection Request Scheduled For: Date: 2/20/2009 Pour Time: Code # Inspection Description Confirm # Contact # Message 299 Final inspection 080652 -01 503. 332 -6458 N Corrections/Comments/Instructions: eii 2'0 -©0 - poi 44-t f(- ) ❑ P. % PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS 4._ J._ • *ALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED - 2 - / Inspector: Date: 2� Phone #: (503) 718- °C 7 y - W CITY OF TIGARD BUILDING DIVISION r PERMIT #: 6UP 2008 -00317 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/ 13/2000 Phone: (503) 639 -4171 �.k -,� AI Inspection Requests (24 Hrs.): (503) 639 -4175 W 1_.. INSPECTION WORKSHEET FOR DATE: 2!1312009 TIME: ?_00AM PAGE: 2 SITE ADDRESS: 00815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CEN t tN GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY PHONE #: 583.885 -9370 Inspection Request Scheduled For: Date: 2/13/2009 Pour Time: Code # Inspection Description Confirm # Contact # Messase 299 Final inspection 080540 -01 503. 332 -6458 411. Corrections /Comments /Instructions: IP z_001 - aooc, / — R'P�' °V CL G. Z a a 1- o o c o 6 KLCIA5 AP. f t v/-+-C— 0 Zoa8 a 0 Z _ 9 / — o. [C.i�� u ZeNgo — 00 :3f31 IIL.LN Apricovii OV l G l e - 1 c.a AD. O t ►' CIO k_ ❑ P' • PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS \,! FAI ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED 1.-/ Inspector: Date: 1 IS Phone #: (503) 718 - 2_6 l e CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2008.00317 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 111 i3 /20013 Phone: (503) 639 -4171 :� y Inspection Requests (24 Hrs.): (503) 639 -4175 I,,L� �I INSPECTION WORKSHEET FOR DATE: 1/22/2009 TIME: 7 :00AM PAGE: 13 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: F ANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY PHONE #: 503.885.9370 Inspection Request Scheduled For: Date: 1/22/2009 Pour Time: Code # Inspection Description Confirm # Contact # Message 23 Shear walls/anchors 079917 -01 503- 332 -6450 • L Corrections/Comments/Instructions: /U i . .� G /V1 -'/L - ■ ► -_r 'L H-..-' <C> I44-z_f ‹. -All. - • PARTIAL APPROVAL El CANCEL El NO ACCESS U FAIL U 'ALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED . ` � Inspector: 7' Date: 1 z2 o1 Phone #: (503) 718 - 2-647 CITY OF TIGARD • BUILDING DIVISION PERMIT #: BUP2008- 00317 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 1111312008 Phone: (503) 639 -4171 ,, ,, � Inspection Requests (24 Hrs.): (503) 639- 4175l INSPECTION WORKSHEET FOR DATE: 1/21/2009 TIME: 7 :00AM PAGE: 23 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCI COMPANY PHONE #: 503885 -9370 Inspection Request Scheduled For: Date: 1/21/2009 Pour Time: Code # Inspection Description Confirm # Contact # Message d r ow_ 280 Insulation 079866-02 503 - 332 -6458 Corrections/Comments/Instructions: ' C°/ ASS ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FA '. . • CALL ROR INSPECTION ❑ ADDITI 9 NAL F ES ASSESSED Inspector:a Date: P hone #: (503) 718 - ✓ + -, CITY OF TIGARD . i -- BUILDING DIVISION = PERMIT #: BuP2008-00317 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11! 13% OW Phone: (503) 639 -4171 / a1w ' i Inspection Requests (24 Hrs.): (503) 639 -4175 .�' F'I .. INSPECTION WORKSHEET FOR DATE: 1/21/2009 TIME: 7:00AM PAGE: 24 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY • PHONE #: 503. 885 -9370 Inspection Request Scheduled For: Date: 1/21/2009 Pour Time: Code # Inspection Description Confirm # Contact # Message 275 Framing 079866-01 503- 332 -6458 Y Corrections /Comments /Instructions: l a "PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL n ALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: -. Date: / O Phone #: (503) 718- Z‘____, CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2008- 0:311 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/13/2008 Phone: (503) 639 -4171 J v Inspection Requests (24 Hrs.): (503) 639 -4175 n_ : INSPECTION WORKSHEET FOR DATE: 1/20 /2009 TIME: 7:00AM PAGE: 37 SITE ADDRESS: 0$815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY PHONE #: 503885-9370 Inspection Request Scheduled For: Date: 1/20/2009 Pour Time: Code # Inspection Description Confirm # Contact # Message 275 Framing 079828 -01 503. 332 -6459 dip t"1 Corrections /Comments /Instructions: G_ - _ " - 'Age' _ `. CY L— I _ L U L — IC G.v 1 w: _ -.as L_ - 7)•1-1- S i l4-f cc 4C:• K 4 lrt-f - z, 4-72y \4 e, t _ - , c7 t- i- 14 ► Lc_- A) �2. ' - r - c7 17. o ti r- A, 2 - --- t C /PL.-- 4. • - /2 cam __.. e. Ara i — 'L= ,,M 400 ..._ - A PARTIAL APPROVAL Ill CANCEL [II NO ACCESS ; y! d!CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED _______ /71/7/ Inspector: - _ Date: 1 1Zb10 7 Phone #: (503) 718 2 - ■ CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2008-00317 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11113/2008 Phone: (503) 639- 4171�y ,.lilt Inspection Requests (24 Hrs.): (503) 639 -4175 ' : _.. INSPECTION WORKSHEET FOR DATE: 1/14/2009 TIME: 7 :01AM PAGE: 34 SITE ADDRESS: 081315 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY PHONE #: 503 - 885.9370 Inspection Request Scheduled For: Date: 1/14/2009 Pour Time: Code # Inspection Description Confirm # Contact # Message 250 Roof nailing 079671 -01 503 - 332 -6458 N Corrections /Comments /Instructions: • Ae t P' : a PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS • FAIL VALL FOR INSPECTION ❑ADDITIONAL FEES ASSESSED Inspector: - — AI! / ///4? Phone #: (503) 718 - Z CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2008- 00317 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/13/2008 Phone: (503) 639 -4171 l ;d . Inspection Requests (24 Hrs.): (503) 639 -4175 ..��� INSPECTION WORKSHEET FOR DATE: 1/6/2009 TIME: 7:p0Am PAGE: 37 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY PHONE #: 503 - 885.9370 Inspection Request Scheduled For: Date: 1/6/2009 Pour Time: Code # Inspection Description Confirm # Contact # Message 275 Framing 07937601 503 -332 -6458 �� =- Corrections /Comments /Instructions: O - - C.-A-L PeT /"L '— 1Jv -s-- ,Z- (-. 7\ V T S 771 Kg •to . S kj ❑� // PARTIAL APPROVAL 111 CANCEL ❑ NO ACCESS 1 r 1. / FAIL 11 CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED r� 6 Inspector: Date: I (e) 0 / Phone #: (503) 718- Z-g CITY OF TIGARD . BUILDING DIVISION PERMIT #: BUP2008- 00317 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 1111300118 Phone: (503) 639 -4171 /omau +� Inspection Requests (24 Hrs.): (503) 639 -4175 IL. INSPECTION WORKSHEET FOR DATE: 12/30/2008 TIME: 7 :00AM PAGE: 21 SITE ADDRESS: 08416 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY PHONE #: 503.885.9370 Inspection Request Scheduled For: Date: 12130/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 240 Exterior sheathing 079240 -02 503 - 449.6664 N Corrections /Comments /Instructions: (3) ¶ t rh`pE o I Q S —' / I Z )Cg C i Ni 4-14---e_--- C,'t 1 2 `' Z r (' PAS , S PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS • AIL CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: Date: /Z--7 Phone #: (503) 718- / i CITY OF TIGARD BUILDING DIVISION .' PERMIT #: BUP2008.00317 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/13/2008 Phone: (503) 639 -4171 Inspection Requests (24 Hrs.): (503) 639 - 4175 ilitA INSPECTION WORKSHEET FOR DATE: 12/30/2008 TIME: 7:00AM PAGE: 22 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY PHONE #: 503885 -9370 Inspection Request Scheduled For: Date: 12/3012000 Pour Time: . Code # Inspection Description Confirm # Contact # Message 235 Shea' walls/anchors 079240 -01 503 - 449.6664 N Corrections /Comments / Instructions: -=)v S Pc�- ' /-h . 5 A-S Fr 1. f 20 ' iT PL-4 l-- ,te _< I=e CZ.. A/424 —S / A) T 7 ❑ PASS / 4 A -e - TIAL APP: • , ❑ CANCEL ❑ NO ACCESS ❑ FAIL % /CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED /3% Inspector: Date: g Phone #: (503) 718- Z Th 1 CITY OF TIGARD , BUILDING DIVISION PERMIT #: BUP2000 -00317 13125 SW Hall Blvd., Tigard, OR 97223 • DATE ISSUED: 11/13/2008 Phone: (503) 639 -4171 "ow Inspection Requests (24 Hrs.): (503) 639 -4175 J INSPECTION WORKSHEET FOR DATE: 12/7/2008 TIME: 7 :00AM PAGE: 8 SITE ADDRESS: 08815 SW O'MAIRA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY PHONE #: 503- 885.9370 Inspection Request Scheduled For: Date: 17/2/2008 Pour Time: 11:00 Code # Inspection Description Confirm # Contact # Message 210 Foundation walls 078691 -02 503. 3316458 OP Corrections /Comments /Instructions: o IQ O Pv a . ma. - - / — — e__ -- ve- A- r� - i o\l,q-c-- fi PA II PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS • FAIL a CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED c _ / 9� Inspector: Date: ! Z4g Phone #: (503) 718 - 2 9L `7 CITY OF TIGARD BUILDING DIVISION - PERMIT #: BUP2008-00317 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/13/2008 Phone: (503) 639 -4171 ,+° 9I�I� Inspection Requests (24 Hrs.): (503) 639 -4175 °`:_.. INSPECTION WORKSHEET FOR DATE: 12/2/2008 TIME: 7:00AM PAGE: 9 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY PHONE #: 503 - 685-9370 Inspection Request Scheduled For: Date: 12/2/2008 Pour Time: 11:00 Code # Inspection Description Confirm # Contact # Message 205 Footing 078691 -01 503 -332 -6458 N Corrections /Comments/ Instructions: — - il—..i /L Al° Po u 1 4/ 1 ` `, •ASS Ni PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL % CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED / Inspector: Date: / Z / 0 0 Phone #: (503) 718- 2.6L-7 CITY OF TIGARD BUILDING DIVISION • :.. PERMIT #: BUP2008 -00317 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/13/2008 Phone: (503) 639 -4171 °� Inspection Requests (24 Hrs.): (503) 639 -4175 .,' °°'I I .. INSPECTION WORKSHEET FOR DATE: 1211/2008 TIME: 7:00AM PAGE: 33 SITE ADDRESS: 00815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD. CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY PHONE #: 503 Inspection Request Scheduled For: Date: 12/1/2008 Pour Time: 9 Code # Inspection De cription Confirm # Contact # Messase 205 Footing M0iNO 078540.01 503 -332 -6458 40 FO Corrections /Comments /Instructions: F,tv\/ / - 7 - )9 - 1■.i( P `1 i ,1 t-v dV lip► Fo lC___ LL___ — - e_____ S Pe. 2 V r s u ►ELK S rc Iv - P ! — — FA / k --f A I`o — r/ 1 /4 C — t _Age Leo 'we = .ri ■ / Fverri k.)6.-, it C / 6 i r 0 C__ (_ )) 4 I ( • PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS �!� . ./ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: Date: / Z d!/ Phone #: (503) 718 - 2' r CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2008.00317 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: i 1/1312008 Phone: (503) 639 -4171 - Inspection Requests (24 Hrs.): (503) 639 -4175 ° - INSPECTION WORKSHEET FOR DATE: 12/1/2008 TIME: 7:00AM PAGE: 32 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY PHONE #: 603 Inspection Request Scheduled For: Date: 12/1/2008 Pour Time: 9:00 Code # Inspection Description Confirm # Contact # Message 2 20 Slab 078540 -02 503.332 -6458 N Corrections /Comments /Instructions: it Li r k D Z r U6 1 111 PASS / PARTIAL APPROVAL .t NCE • 111 NO ACCESS ❑ FAIL f/ CALL FOR INSPECTION 111 ADDITIONAL FEES ASSESSED Inspector: Noy _ �— Date: 7 0 ' U,/ Phone #: (503) 718- Z 64-7/ CITY OF TIGARD • BUILDING DIVISION PERMIT #: I3UP2008.00317 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 1'i/13/2008 Phone: (503) 639 -4171 'Olt Inspection Requests (24 Hrs.): (503) 639 -4175 ,. IL. INSPECTION WORKSHEET FOR DATE: 11/21/2008 TIME: 7:00AM PAGE: 34 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY PHONE #: 503.995.9370 Inspection Request Scheduled For: Date: 11/21/2008 Pour Time: 2 :00 Code # Inspection Description Confirm # Contact # Message 205 Footing 078353.01 503 - 332 -6458 N Corrections /Comments /Instructions: L c \ ✓+ S e C 'i o, Li, i �l p) ,v104--..-5 SS ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: 3.S Date: 2/ 'hoc & Phone #: (503) 718- 2Y23 CITY OF TIGARD = • BUILDING DIVISION • ' PERMIT #: BUP2008.00317 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/13/2000 Phone: (503) 639-4171 il: i Inspection Requests (24 Hrs.): (503) 639 -4175 F' � . INSPECTION WORKSHEET FOR DATE: 11/21/2008 TIME: 7:00AM PAGE: 33 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: TIGARD SENIOR CENTER GARDEN RM DESCRIPTION: Garden room addition. OWNER: TIGARD, CITY OF, PHONE #: CONTRACTOR: CEDAR MILL CONSTRUCTION COMPANY PHONE #: 503.885.9370 Inspection Request Scheduled For: Date: 11/21/2008 Pour Time: 2:00 Code # Inspection Description Confirm # Contact # Message 220 Slab 070353 -02 503 -332 -6458 N Corrections/Comments/Instructions: 0 k ea , • Ai _ • SS ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: Date: 2/ 4v 0 9 Phone #: (503) 718- .2(/23