Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
OF TIGARD BUILDING PERMIT PERMIT #: BUP2007 -00502 COMMUNITY DEVELOPMENT DATE ISSUED: 11/26/2007 TIGARD 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 PARCEL: 2S102DB -00500 SITE ADDRESS: 08815 SW O'MARA ST ZONING: CBD SUBDIVISION: FANNO CREEK PARK LOT: JURISDICTION: TIG PROJECT: SENIOR CENTER Project Description: TI and addition REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: ADD FIRST: 854 sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 5N : sf N: S: E: W: • OCCUPANCY GRP: A3 TOTAL AREA: 854 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: 318 BASEMENT: sf AREA SEP. RATED: STOR: HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: Y SMOK DET:Y DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : Y HNDICP ACC:Y BEDRMS: BATHS: IMP SURFACE: PRO CORR: N PARKING: VALUE: $ 700,000.00 Owner: Contractor: TIGARD, CITY OF KEL TEC BUILDERS 13125 SW HALL 251 ARTHUR RD TIGARD, OR 97223 MARTINEZ, CA 94553 Phone: public works 503 - 718 - Contact #: PRI 925 - 229 -5508 Reg #: LIC 164210 FEES Description Date Amount REQUIRED ITEMS AND REPORTS [BUILD] Permit Fee 11/26/2007 $2,325.20 Ersn Cntrl 681 - 4444 [TAX] 8% State Surcha 11/26/2007 $186.02 Reinforced concrete [BUPPLN] PIn Rv 11/26/2007 $1,511.38 [ELS] FLS Pin Rv 11/26/2007 $930.08 (additional fees not listed here) Total $6,425.28 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. Issued By: Permittee Signature: #6 0 Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. oo y op_ Cep i0- i� �c,0 tk ti-21-i1D c7- Ocoaa Building Permit Annl' R 11\1 FOR OFFICE USE ONL1' . Cl of Tigard Received I n�Os� / / '/ O� City g Date /B Ot / Permit No.: / /�/ ry IN ° 13125 SW Hall Blvd., Tigard, OR 97 ',3p 2007 DatePlan Revie Phone: 503.639.4171 Fax: 503.598`. 0 2 5 B Sl�� ®® Other Permit: T I G A It D rn Inspection Line: 503.639.4 'T 1 Of Ii " Date Read — 1Y: 1 : See Attached Checklist for Internet: www.tigard - or.go i 1 � Notified/Method: 1 /Q /oi {/ 11_10 ® Supplemental Inform lion BUTT DING DIVISION / 1,,...v m i „c isDfi v I0 TYPE OF WORK REQUIRED IIATA: 1- AND 2- FAMILY DWELLING 0 New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ® Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1- and 2- family dwelling ® Commercial/industrial Valuation: $ ❑ Accessory building El Multi-family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: h Job site address: 8815 SW O'Mara St. New dwelling area: square feet City/State /ZIP: Tigard / OR / 97223 Garage /carport area: square feet Suite/bldg. /apt. no.: Project name: ,t43 (pA 1, Lk.) f Covered porch area: square feet Cross street/directions to job site: SW Hall Blvd, west on O'Mara to site Deck area: square feet • Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST t Subdivision: I Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: 2S102DB / 00500 Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. Interior remodel of existing facility; addition of 854 sq. ft Valuation: $$700,000.00 Existing building area: 8,380 square feet New building area: 854 square feet ® PROPERTY OWNER I ❑ TENANT Number of stories: I ly/ ba•$,_M 11. Name: City of Tigard - Public Works Type of construction: V -N Address: 8777 SW Burnham Street • Occupancy groups: City/State /ZIP: Tigard / OR / 97223 Existing: A -2 Phone: (503)718 -2590 Fax: (503)684 -7297 New: A -2 ❑ APPLICANT ® CONTACT PERSON NOTICE Business name: LRS Architects All contractors and subcontractors are required to be Contact name: Peter Dixon licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: 720 NW Davis St. jurisdiction in which work is being performed. If the City/State /ZIP: Portland / OR / 97209 applicant is exempt from licensing, the following reasons apply: Phone: (503) 265 -1570 I Fax: : (503) 221 -2077 E -mail: pdixon @Irsarchitects.com CONTRACTOR 1 Business name: �:!EiL . 1 Ll p . 'L i.L.D i2S � L � BUILDING PERMIT FEES* Address: , Z10 me 1 5 67-. ,....5 .. 5i V (Please refer to lee schedule Structural plan review fee (or deposit): City/State /ZIP: J I ter I ' FLS plan review fee (if applicable): Phone: 400) e 0 Fax: L ) z Be CCB lic.: // 4 u(' Total fees due upon application: n Amount received: Authorized signature: J� This permit application expires if a permit is n obtained I q within 180 days after it has been accepted as complete. Print name: pe D Xp VV Date: / 4S/Q 7 • Fee methodology set by Tri-County Building Industry Service Board. I: \ Building \Permits\BUP- PermitApp.doc 03/21/06 4404613T(I1 /02/COM/WEB) ' I 5 nC'✓Ya-v�c6fi . 4 , ,, l 3 c i f - -odS6 D , _ , 3a Project Name: Tigard Senior Center Addition Page: 1 BUILDING ENVELOPE - GENERAL 1 . U ,;, Check at boxes that 1. Exceptions (Section 1312) -- r IfF:n apply' ❑ No Envelope Components. The building plans do not call for new or altered building envelope $ components, e.g., walls, floors or roof /ceilings. SEP ? 5 • ❑ A Non - conditioned Building. The proposed structure has no spaces heated or cony, 1001 an HVAC system. Exceptions ❑ Exception. All new or altered building envelope components do not comply wit � r� 7 1 i LitilOD Discussion of qualifying requirements, Section 1312, but qualify for Exception: 0-1 0 -2 0 -3 LING exceptions in instructions DJ-- Ri Portions of the building that qualify: Plans /Specs _ Show compliance by including The plans/specs show compliance in the following locations: shts. A401, A501 a drawing sheet, detail number, specification section and/or subparagraph. 2. Air Leakage (Section 1312.1.1) CI Complies. Plans require penetrations in building envelope are sealed and windows and doors are caulked, gasketed or weatherstripped. The plans /specs show compliance in the following locations: Door & Window details , shts. A203, A204, spec. section 07 2500. . . 3. Suspended Ceiling (Section 1312.1.2.1) • ❑ Complies. Building plans do not show suspended ceilings used to separate conditioned space from unconditioned space. No exceptions permitted. 4. Recessed Light Fixtures (Section 1312.1.2.2) O Complies. The building plans do not show recessed light fixtures installed in ceilings separating conditioned spaces from unconditioned spaces. ❑ Exception. The building plans require that fixtures installed in direct contact with insulation be insulation coverage (IC) rated. The plans/specs show compliance in the following locations: 5. Moisture Control (Section 1312.1.4) 17 Complies: A one -perm vapor retarder is installedon the warm side (in winter) of all exterior floors, walls and ceilings, and a ground cover installed in the crawl space of both new and existing buildings where insulation is installed. • The plans /specs show compliance in the following locations: Spec. sections 072100 and 07 2500. ❑ Exception. All new or altered building envelope components do not comply with the vapor retarder requirements of the code, but qualify for an exception. Note applicable exception. Section 1312.1.4, Exception: 0-1 ❑ -2 Portions of the building that comply: Climate 6. Climate Zones Zones 21 Zone 1 - A building site is in Climate Zone 1 if its elevation is less than 3000 feet above sea level and it is in one of the following counties: Benton, Columbia, Clackamas, Clatsop, Coos, Curry, Douglas, Jackson, Josephine, Lane, Lincoln, Linn, Marion, Multnomah, Polk, • Tillamook, Yamhill, or Washington. , f; ❑ Zone 2 - Building sites not in Zone 1, or where construction site elevation is 3000 feet or ~ a t higher in Zone 1, are in Zone 2. . G. >1 \ � 1 , n.. ., • 3 -1 Compliance with OSSC, effective 01/01/05 Form 3b Project Name: Tigard Senior Center Addition Page: 2 PRESCRIPTIVE PATH Part 1 of 4 CLIMATE ZONE 1 Exterior Wall Window Area Area Maximum Glazing Fraction (total rough frame ft2) (gross ft2) Glazing % Complies Glazing Conditioned 36.4% Yes Percent Cale. Space 451 + 1,238 x 100 = elation ' See instruction Semi - section for a Conditioned 2 + 93 X 100 = 2.2% Yes discussion of glazing Space percent calculation. Conditioned Mechanical n/a + x 100 = 0.0% Yes Penthouse Windows Window Max Minimum Shading Minimum From Work - sheet 3d, Window z (from Worksheet 3d) U Factor Assembly mom Worksheet set Coefficient Assembly place the highest Overall Window U- #N/A - ❑ #NIA - ❑ factor and highest Center - of - Glass SC. U -Value Complies Yes SC Complies Yes Or check minimum assembly and identify window. Required Minimum Assembly (Fixed N/A Required Minimum Assembly N/A Windows) • Required Mini -mum Assembly (Operable Windows and WA Curtainwall) • The plans /specs show window compliance in the following locations: Spec. section '08 5400 Composite Windows', Window types sheet A203, Ext. Elevations sheet A401. Notes 'From Worksheet 3d, place the highest Overall Window U- factor or check (Minimum Assembly). See 'Window Requirements' in table on the following page for specific MA requirements. Excel version will automatically insert minimum assembly requirements or greatest U -value from Worksheet 3d. 2 'From Worksheet 3d, place the highest 'center-of-glass' shading coefficient (SC) for glass or check MA (Minimum Assembly). See 'Window Require -meets' in following table for specific MA requirements. Excel version will automatically insert minimum assembly requirements or greatest SC from Worksheet 3d. Shading Coefficient (SC) can be calculated from Solar Heat Gain Coefficient using the equation: SC = SHGC • 0.87. Manufacture's data may also be used to document SC. Walls R -Value Wall / Insulation Type Insulation Only U- Factor See instructions for .. a discussion of wall I Frame (wood or metal framing) : I 19 or require - mends. I _ .. . J or J or j or J Or • or Below -Grade R - Value Walls Insulation Only U- Factor See instructions fora Below - Grade Walls (Mm. R -7.5) (Mex. 0.11) discussion of "a. 0 requirements. n/a or h^ ' =`' �• tv . �r :: y Notes 3 Submit Worksheet 3a for each calculated assembly U- factor tri: 3 -2 Compliance with OSSC, effective 01/01/05 0 Form 3b Project Name: Tigard Senior Center Addition Page: 3 PRESCRIPTIVE PATH Part 2 of 4 Code Requirements - Zone 1 Discussion of these requirements in the instruction section. ZONE 1 Wall Requirements Window Requirements Max. Glazing R -Value Max. Shading Fraction Wall / insulation Type Insulation Only U- Factor Max. U- Factor Coefficient CMU 'Masonry w/integral loose fill Insulation N/A Or 0.300 Up to 15% 0.540 0.57 Masonry or concrete w /cont exterior Insulation 1.4 or 0.300 CMU Masonry w/integral rigid fill insulation N/A or 0.210 Masonry or concrete w/interior Insulation 11 or 0.130 Masonry or concrete w /cont exterior insulation 2 . 8 Up to 30% M or 0.210 0.540 0.57' Frame (wood or metal framing) 13 or 0.1 30 Other (provide short description) 1 3 or 0.130 CMU Masonry w/integral rigid fill Insulation N/A or 0.21 Masonry or concrete w/Interior Insulation 11 or 0.130 - Up to 40% Masonry or concrete w /cont exterior insulation 2.8 or 0.210 0.37010 0.351° Frame (wood or metal framing) 13 or 0.130 Other (provide short description) 13 or 0.130 Code Requirements - Zone 2 . Discussion of these requirements in the instruction section. ZONE 2 Wall Requirements Window Requirements Wall / Insulation Type Max. Shading Max. Glazing R -Value U- Factor Max. U- Factor Coefficient Fraction Insulation Only CMU 'Masonry w/Integral loose fill° insulation N/A or 0.300 11 11 Up to 15% Masonry or concrete w /cont exterior insulation 1.8 or 0.270 0.500 0.57 CMU Masonry w/integral rigid fill Insulation N/A or 0.1 60 Masonry or concrete w/interior Insulation 13 or 0.090 Up to 25% M or D.500 r concrete w /cont exterior Insulation 4.3 or 0.160 11 0.57 11 Frame (wood or metal framing) 1 or 0.090 Other (provide short description) 19 or 0.090 CMU Masonry' w/integral rigid fill Insulation N/A or 0.1 60 Masonry or concrete w/interior insulation 13 or 0.090 Up to 33% Masonry or concrete w /cont exterior insulation 4.3 or 0.160 0.370 0.43 Frame (wood or metal framing) 19 or 0.090 Other (provide short description) 1 9 or 0.090 Notes 4 The Simplified Trade-off Approach must be used if glazing fraction exceeds allowable percentages. 5 Minimum weight of masonry and concrete walls = 45 lb/f12 of wall face area e All cores to be filled. At least 50% of cores must be filled with vermiculite or equivalent fill insulation. r Prescriptive MA (Madmum Assembly) - For Fixed Windows: double - glazed window with a 0.5 inch air space, low-e coating and aluminum frame. MA shading coefficient description Is a tinted outboard pane of glass. For Operable Windows or Curtalnwell: double-glazed window with a 0.5 inch air space. low-e coating and thermally broken frame. MA shading coefficient description is a tinted outboard pane of glass. 8 All cores except bond beams must contain rigid insulation inserts approved for use in reinforced masonry walls ° Batt insulation Installed In metal or wood frame walls shall be insulated to the full depth of the cavity, up to 6 Inches In depth. 1e Prescriptive MA (Minimum Assembly) - For Fixed Windows: double - glazed window with a 0.5 Inch argon filled space, low-e coating (e <= 0.05) and thermal break frame. For Operable Windows or Curtalnwall: only use Max U- Factor. MA shading coefficient description is a 0.25 -inch thick glass with low-e coating (e <= 0.05) with a tinted outboard pane. if Prescriptive MA (Minimum Assembly) - For Fixed Windows: double - glazed window with a 0.5 inch air space. low-e coating and aluminum frame. For Operable Windows or Curtalnwall: double - glazed window with a 0.5 inch air space, low-e coaling (e <= 0.1) and thermally broken frame. MA maximum shading coefficient description is a tinted outboard pane of glass. »f 12 Prescriptive MA (MinimumAssembly) -For Fixed Windows, adouble- glazed window with a 0.5 inch argon filled space. low-e coating (e<= 0.05) and thermal break frame. For s i_ .,� Ope rable Windows or Curtainwall, only use Max LL Factor. MA shading coefficient description is a 0.2 54nch think glass with low a coating (e <= 0.05). V. 3 Compliance with OSSC, effective 01/01/05 • 'r Form 3b Project Name: Tigard Senior Center Addition Page: 4 PRESCRIPTIVE PATH Part 3 of 4 Roofs/ R -Value Ceilings Insulation Only U- Factor See instructions for a Roof / Ceiling" (Min. R -19) (Max. 0.050) dicussion of TJI framing, plywood sheathing, built -up roofing 19 or roofs/ceilings. Notes " Write -In a short description for assembly with the lowest insulation R -value or the highest assembly U- factor. 12 Submit Worksheet 3b for each calculated roof/ceiling assembly U-factor. Skylight Area Roof Area Skylight 96 Maximum Skylight (total rough frame ft2) (gross ft2) 13 Fraction Complies Skylights Conditioned Includes glazed Space N/A + x 100 = N/A smoke vents. See instructions for a Seml- dicussion of skylights. Conditioned + X 100 = N/A Space Conditioned Mechanical + X 10 = N/A Penthouse Skylight Area (total rough frame Roof/Ceiling Area Skylight ft2) (gross ft2) Percent" • Skylights b ASkylights Max Minimum Skylights Shading Minimum From Worksheet 3d, from Worksheet 3d) - Factor" Assembly Pm cu d sat Coefficien Assembly place highest Overall ( UFt ly ly Vertical Window U ON/A - ❑ #NIA - N/A factor and highest Center-of-Glass SC. U -Value Complies Yes SC Compiles Yes Required Minimum N/A Required Minimum Assembly N/A (must use SC) Assembly The plans/specs show window compliance In the following locations: Code Thermal Performance Shading Coefficient Require- Compliance Option Overall Vertical U Factor Center of Glass SC meats Performance U -1.230 for overall assembly In overhead plane SC-0.47 center -of -glass Min. Assembly Double glazed. 0.5-Inch airspace N/A (MA) Notes 13 Skylight percentage area is based on total skylight and smoke vent rough frame area divided by total conditioned roof area. Percentage must not exceed 6 percent of total roof/ceiling area in conditioned building space. The Simplified Trade-off Approach must be used if glazing fraction exceeds allowable percentages. 14 From Worksheet 3d, place the highest Overall Vertical U factor or write MA (Minimum Assembly). See 'Skylight Requirements' in table above for specific MA requirements. 1s From Worksheet 3e, place the highest "center-of-glass' shading coefficient (SC) for glass. See 'Skylight Requirements' in table above for specific MA requirements. Shading Coefficient (SC) can be calculated from the Solar Heat Gain Coefficient using the equation: SC = SHGC • 0.87. Manufacturers data may also be used to document SC. c . 3 Compliance with OSSC, effective 01/01/05 • Form 3b Project Name: Tigard Senior Center Addition Page: 5 PRESCRIPTIVE PATH Part 4 of 4 Floors See instructions for R -Value a dicussion of Floors over Unconditioned Spaces" Insulation 0ny U- Factor floors. N/A or " Heated Concrete Slab Edge R -Value Insulation Only Heated Slab -on -Grade (Section 1312.1.2.4) ❑ Complies. Building plans show insulation extending downward from the top of the slab a minimum distance of 24 inches or downward and under the slab for a combined minimum distance of 24 inches or to the bottom of the thickened edge of the of slabs used as a foundation. The plans /specs show compliance in the following locations: • Notes 's Write -In a short description for assembly with the lowest insulation R -value or the highest assembly U- factor. ' Submit Worksheet 3c for each calculated floor assembly U- factor. 18 Write-in a short description for Heated Slab, which has heat, Integrated into stab such as hydronic heat. If more than one floor type, enter the lowest Insulation R -value or the highest component U- factor of any floor. Code Compliance Options Require- Min. R -Value meats Component Insulation Only Max. U -Factor Floor over Unconditioned Spaces I 11 I " I 0.070 Climate Climate Component Zone 1 Zone 2 Heated Concrete Slab Edge, Min. R -Value I 7.5 1 or I 10.0 Doors See instructions fora R -Value U- Factor dicussion of doors. Doors" Insulation Only Center-of -Panel opaque, with leaf width greater than 4' (Min. R -5) (Max. 020) or Notes ' Write -in a short description for Doors. If more than one door type, enter the lowest insulation R -value or the highest center-of-panel U -factor of any door. The following doors are exempt from door and window U- factor and shading coefficient requirement • 0 3-5 Compliance with OSSC, effective 01/01/05 1 Form 4a Project Name: Tigard Senior Center Page: 6 SYSTEMS - GENERAL Applicability Plans /Specs Discussion of qualifying Show compliance by including a drawing sheet, detail number, exceptions on page 4 -25 specification section and subparagraph. 1. Applicablity (Section 1317) Is this form required? o Form Required. Complete form if a new HVAC system is being installed, or components of an existing HVAC system are being replaced (I.e., equipment, controls, ductwork, and insulation.) ❑ Exception. The building or part of the building qualifies for an exception from HVAC code requirements. Applicable code exception is Section 1317.1. Portions of the building that qualify: Area: Exception ❑ -1 ❑ -2 ❑ -3 Area: Exception ❑ -1 ❑ -2 ❑ -3 Area: Exception ❑ -1 ❑ -2 ❑ -3 ❑ Form Not Required. This project does not contain work required to comply with code. 2. Simple or Complex Systems (Section 1317.9 or 1317.10) o Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and equipment efficiency worksheets as required. Form 4b is not required. ❑ Complex System. Project includes a Complex System. Complete this form (4a), form 4b and equipment efficiency worksheets as required. 3. Equipment Performance (Section 1317.5) ❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment, or heat - operated cooling equipment. o Complies. All new HVAC equipment have efficiencies not less than those required by code. The following equipment efficiency worksheets are attached: ❑ -4a ❑ -4b GI -4c ❑ -4d ❑ -4e ❑ -4f ❑ -4g ❑ -4h ❑ -4i ❑ -4 4. Duct Insulation and Sealing (Sections 1317.7 & 1317.8) ❑ No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. o Complies. The plans and specifications call for all air - handling ducts and plenums to be insulated and sealed as reauired by Sections 1317.7 &1317.8. 5. Distribution Transformers (Section 1316.1) o No Distribution Transformers. The plans /specs do not call for new distribution transformers. ❑ Complies. All new distribution transformers comply with efficiency, testing, and labeling requirements of Section 1316.1.1. ❑ Exception. The project qualifies for an exception per Section 1316.1.1, Exceptiion: 0-10-2 0-3 0-4 0-5 0-8 0-7 0-8 0-9 0-10 0-1 0-120-120-14 Attach relevant documentation for appropriate exception. The plans /specs show compliance in the r - ••?+ following locations: .. 4 -1 Compliance with OSSC, effective 04/01/07 Form 4 a Project Name: Tigard Senior Center Page: SYSTEMS - GENERAL 6. HVAC Controls (Section 1317.4) 6.1 System Thermostat /Zone Controls (Section 1317.4.1) . El Complies. All new HVAC systems include at least one temperature control device responding to temperatures within the zones. ❑ Exception. HVAC system qualifies for an exception from zone control requirements. The applicable code exception is Section 1317.4.2, Exception 0-1 0-2 Portions of the building that qualify: , The plans /specs show compliance in the following locations: Drawing M1.0 6.2 Off - hour Controls - Auto Setback or Shutdown (Section 1317.4.3) 2 Complies. Systems must have at least one of the following features: 2 Control Setback Complies. Each system is equipped with automatic control capable of reducing energy through control setback during periods of non -use or alternate use of spaces served. 2 Equipment Shutdown Complies. Each system is equipped with controls capable of reducing energy use through automatic shutdown during periods of non -use or alternate use of spaces. HVAC systems with equipment shutdown are equipped with at least one of the following: 9 Programmable controls (1317.4.3.1 (1)) ❑ Occupant sensor (1317.4.3.1 (2)) ❑ Interlocked to a security system (1317.4.3.1 (3)) ❑ Manually activated timers with 2 -hour operation max (1317.4.3.1 (4)) ❑ Exception. The building qualifies for an exception to the requirement for automatic setback or shutdown controls. The applicable code exception is Section 1317.4.3 Exception ❑ -1 ❑ •2 The plans /specs show compliance in the following locations: Drawing M1.0 6.3 Control Capabilities (Sec. 1317.4.2.1) O Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. ❑ Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section 1317.4.2.1 Exception 0-1 0-2 Portions of the building that qualify: The plans /specs show compliance in the following locations: Drawing M1.0 6.4 Optimum Start Controls (Section 1317.4.3.2) ❑ Complies. Separate HVAC systems have controls capable of varying start-up time of system to just meet temperature set point at time of occupancy. 2 Exception. HVAC systems have a design supply air capacity not exceeding 10,000 cfm. The plans /specs show compliance in the following locations: 6.5 Heat Pump Controls (Section 1317.4.4) ❑ No Heat Pump. The plans /specs do not call for a new heat pump 2 Complies. All new heat pumps equipped with supplementary heaters are controlled to minimize the use of supplemental heat as defined in Section 1317.4.4. C :` The plans /specs show compliance in the following locations: �:: Drawing M1.0 II 4 -2 Compliance with OSSC, effective 04/01/07 .c t Form 4a Project Name: TI and Senior Center Page: L6 SYSTEMS - GENERAL 7. Economizer Cooling (Section 1317.3) ❑ No Cooling. The building plans do not call for a new fan system with mechanical cooling. ❑ Complies. Each new fan system has an air economizer capable of modulating outside -air and return -air dampers to provide up to 100 percent of the design supply air as outside air. o Exception At least one new fan system qualifies for an exception. The applicable code exception is Section 1317.3, Exception ❑ -1 ❑ -2 ❑ -3 ❑ -4 ❑ -5 ❑ -6 ❑ -7 If Exception 3 is selected complete the following: (a) Total cooling capacity of exempt units (Btu /hr) 48000 (b) Total installed building cooling capacity (Btu /hr) N/A 0 Complies. Sum of exempt units rated at less than 54,000 Btu /hr is <240,000 Btu /hr or a/b < 0.10 (10% of total building cooling capacity). Unit Identifier of exempt units: HP1 /FC1 The plans /specs show compliance in the following locations: Drawing M1.0 8. Economizer Pressure Relief & Integration (Section 1317.3.1 and 1317.3.2) El No Economizers Required. Project does not contain a new fan system requiring economizers. ❑ Overpressurization Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will relieve the extra air introduced by the economizer. ❑ Integration Complies. Economizer is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. ❑ Exception. The applicable exception is Section 1317.3.2, Exception III -1 ❑ -2 The plans /specs show compliance in the following locations: 9. Hot Gas Bypass (Section 1317.5) El No Hot Gas Bypass ❑ Complies. See allowable amount of hot gas bypass as a percentage of total cooling capacity in table below. Unit ID Rated Cooling Capacity Hot Gas Bypass Capacity r ,.,. ' Allowable Hot Gas Bypass �. Rated Cooling Capacity Max Hot Gas Bypass r `; <240,000 Btu /hr 50% � '` >240,000 Btu /hr 25% ❑ Exception. Unitary packaged system with cooling capacity no greater than 90,000 Btu /h 4 -3 Compliance with OSSC, effective 04/01/07 • Form 4a Project Name: Tigard Senior Center Page: 9 SYSTEMS - GENERAL 10. Shutoff Dampers (1317.4.3.3) ❑ Not Required. Shutoff dampers are not required on this project. ❑ Complies. Each outdoor air supply & exhaust system shall be equipped with motorized dampers. El Exception. The building qualifies for an exception to the motorized damper requirement. The applicable code exception is Section 1317.4.3.3 Exception ❑ -1 ❑ -2 0 -3 ❑ -4 ❑ -5 ❑ -6 The plans /specs show compliance in the following locations: Drawing M1.0 10.1. Shutoff Damper Controls (Section 1317.4.3.3.1) ❑ Complies. Outdoor air supply and exhaust systems shall be provided dampers that automatically shut when systems or spaces served are not in use or during building warm -up, cooldown, or setback. ❑ Complies. Stair and shaft vents are capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. The plans /specs show compliance in the following locations: N/A ' 10.2. Motorized Damper Leakage (1317.4.3.3.2) ❑ Complies. Motorized outdoor air supply and exhaust air dampers have a maximum leakage rate of 4 cfm /ft2 at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. ❑ Exception. Packaged HVAC equipment may have maximum leakage rate of 20 cfm /ft at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. The plans /specs show compliance in the following locations: N/A 11. Piping Insulation (Section 1314) ❑ No New Piping. The building plans and specifications do not call for new piping serving a heating or cooling system or part of a circulating service water heating system. E Complies. All new piping serving a heating or cooling system or part of a circulating service water heating system complies with the requirements of the Code, Section 1314.1. ❑_ Exception. New piping qualifies for exception: Section 1314.1, Exception ❑ -1 ❑ -2 12. Occupancy Ventilation El Complies. Mechanical ventilation systems provide the required amount of ventilation is indicated in plans /specifications as specified in Chapter 4 of the Oregon Mechanical Specialty Code. ❑ Complies. Natural ventilation systems provide required amount of ventilation as certified by a reg- istered architect or engineer as specified by Section1203.4.1, Exception. Attach worksheet 4m. The plans /specs show compliance in the following locations: Drawing M1.0 The plans /specs show compliance 4 � �% on the following pages: 4 -4 • Compliance with OSSC, effective 04/01/07 , c • Form 4a Project Name: Tigard Senior Center . Page: 10 SYSTEMS - GENERAL 13. High Occupancy Ventilation (Section 1317.2.2) ❑ Complies. HVAC systems with ventilation air capacities of 1,500 CFM or greater that serve areas having an average occupant load of 20 square feet per person or less from Table 1004.1.2 have a means to automatically reduce outside air intake. Identify applicable systems: Plans /specs indicate where equipment (i.e. carbon dioxide sensor) and sequence is specified: ❑ Exception. HVAC systems are equipped with an energy recovery device with at least 50% recovery effectiveness. . O No High Occupancy Systems. Project does not contain an HVAC system as described above. 14. Exhaust Air Heat Recovery (Section 1318.3) O Not Regulated. HVAC system does not have: 1) design supply air cap. of >10,000 cfm, and 2) min. outside air supply >70 %, and 3) at least 1 exhaust fan rated at 75% of min outside air supply. ❑ Complies. Heat recovery system increases outside air temperature by 20 °F (Climte Zone 1) or 30 °F (Zone 2) and has provision to provide bypass during air economizer mode. ❑ Exception. An HVAC system qualifies for an exception to this requirement. Applicable exception from Section 1318.3 Exception❑- ❑.2 ❑ -a ❑-4 ❑.5 ❑ s _-7 The plans /specs show compliance in the following locations: 15. Large Volume Fan Systems (Section 1318.4.2.4) 0 Not Regulated. The building plans or specifications do not call for fan systems over 15,000 CFM that serve a single zone and function for the purpose of temperature control. ❑ Complies. Fan systems are equipped with variable frequency drive or two speed motor to reduce airflow as required by Section 1318.4.2.3. The plans /specs show compliance in the following locations: 16. Variable Speed Drives (Section 1317.10.3.1) O Not Regulated. The building plans or specifications do not call for fan and pump motors 10 horsepower and greater that serve variable -flow air or liquid systems. ❑ Complies. All fan and pump motors 10 hp and greater which serve variable -flow air or liquid systems are controlled by a variable -speed drive. ❑ Exception. The building qualifies for an exception to the variable -speed drive requirement. Portions of the building that qualify: Applicable code exception is Section 1317.10.3.1, Exception The plans /specs show compliance in the following locations: 17. Service Water Heating (Sec. 1315) ❑ No New Water Heating. The building plans and specifications do not call for new water heaters, hot water storage tanks or service hot water distribution systems. . O Complies. All new water heaters, hot water storage tanks or service hot water distribution systems comply with the requirements of the Section 1315. ❑ Exception. The applicable code exception is Section: Exception: Portions of the building that qualify: ,i.1 The plans /specs show compliance in the following locations: Drawing PL1.0 4 -5 Compliance with OSSC, effective 04/01/07 Form 4a Project Name: Tigard Senior Center Page: 11 SYSTEMS - GENERAL 18. Swimming Pools, Spas and Hot Tubs (Section 1315.5) o No New Pools. The building plans and specifications do not call for new, swimming pools, spas or hot tubs. ❑ On /Off Controls Complies. Spa and hot tub heaters are equipped with a readily accessible ON /OFF switch as required by Section 1315.5.1. ❑ Ventilation Controls Complies. Pool ventilation system is controlled based on humidity. ❑ Cover Complies. All heated pools, hot tubs and spas are equipped with a cover. ❑ Heat Recovery Complies. Pools, Spas, and hot tubs, over 200 ft utilize recovered heat as required by Section 1315.5.3. ❑ Exception. Heat recovery is not necessary as pool is heated by renewable energy or waste heat recovery sources capable of providing at least 70 percent of the heating energy required over an operating season. 19. Fume Hoods (Section 1317.2.1.) O No Fume Hoods. The building plans do not call for fume hood systems that have a total exhaust rate greater than 15,000 cfm. ❑ Complies. Fume hood systems have at least one of the following features: ❑ Variable air volume hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50% or less of design values. El Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no Warmer than 2° F below room set point, cooled no cooler than 3° F above room set point, no humidification added, and no simultaneous heating and cooling used for dehumidification control. ❑ Heat recovery systems to precondition makeup air from fume hood exhaust in accordance with 1318.3 - Exhaust Air Energy Recovery, without using any exception. The plans /specs show compliance in the following locations: 20. Parking Garage Ventilation (Section 1317.2.3) o No Enclosed Garages. The building plans and specifications do not call for enclosed Group S -2 parking garages with a ventilation exhaust rate greater than 30,000 CFM. El Complies. The plans and specifications call for carbon monoxide sensing devices as required by Section 1317.2.3. ❑ Exception. Open parking garages. • 21. Kitchen Hoods (Section 1317.11) o Not Regulated. The plans /specs do not call for any new kitchen hoods with exhaust capacity greater than 5,000 cfm each. ❑ Complies. All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm have at least 50 percent of the required makeup air; (a) unheated or heated to no more than 60 °F; and (b) uncooled or evaporatively cooled. 0 ,f• t ;'y The plans /specs show compliance in the following locations: 'o e a: $ 22. Outside Heating Systems (Section 1317.12) El No Outside Heating Systems. The plans /specs do not call for new permanently installed heating systems outside the building. ❑ Complies. All new permanently installed outside heating systems are radiant gas fired systems controlled by an occupancy sensor or timer switch as required by Section 1317.12. 4 -6 Compliance with OSSC, effective 04/01/07 • • Worksheet 4c Project Name: Tigard Senior Center Page: 12 UNITARY HEAT PUMP - AIR COOLED Equipment (a) (b) (c) (f) (9) Proposed Rating Proposed Heating Rana Discussion of equip- Cooling Compliance ment ratings and Capacity COP COP Schedule New or equipment definitions on page 4 -19. Equip. ID Model Designation (Btu /h) SEER EER . HSPF (47 °F) (17 °F) (A -E) Replacmnt• HP1 Carrier 25HNA6 -48 48000 16.3 N/A 9.3 N/A N/A B New • • Required Indicate source of information Document- ❑ ARI Unitary Directory, Section AC, page: ation . ❑ ARI Applied Products directory, Section ULE, Page: , O Product data (Attach data furnished by the equipment supplier, I.e., "cut sheets ") Code Cooling Capacity Minimum Cooling (btu /hr) Rating Minimum Heating Rating Required Compliance But not or Part COP COP Efficiencies Schedule Equipment Type Over over EER Load HSPF (Cp 47°F) (@ 17 °F) New• 0 65,000 - 13 SEER 7.7 - . Single Package Without a Repicmnt• 0 65,000 - 9.7 SEER 6.6 - - A Heating Section or With 65,000 135,000 10.1 n/a - 3.2 2.2 This schedule of Electric Resistance Heat _ equipment efficien- All 135,000 240,000 9.3 n/a 3.1 2.0 cies was reformat- 240,000 - 9.0 9.2 IPLV - 3.1 2.0 ted from the code. Table 13 -M. New' 0 65,000 - 13 SEER 7.7 - - Split System Without a Replcmnt• 0 65,000 - 10 SEER 6.8 - - B Heating Section or With 65,000 135,000 10.1 n/a - 3.2 2.2 Electric Resistance Heat All 135,000 240,000 9.3 n/a - 3.1 . 2.0 240,000 - 9.0 9.21PLV - 3.1 2.0 New' 0 65,000 - 13 SEER 7.7 - - Single Package With a Replcmnt' 0 65,000 - 9.7 SEER 6.6 - - C Heating Section Other Than 65,000 135,000 9.9 n/a - 3.2 2.2 Electric Resistance All 135,000 240,000 9.1 n/a - 3.1 2.0 Vi - , . 240,000 - 8.8 9.0 IPLV 3.1 2.0 r. ' ,ii New' 0 65,000 - 13 SEER 7.7 - - r'.rp ; Split System With a Heating Replcmnt• 0 65,000 - 10 SEER 6.8 - - D Section Other Than Electric 65,000 135,000 9.9 n/a - 3.2 2.2 '� Resistance All 135,000 240,000 9.1 n/a - 3.1 2.0 240,000 - 8.8 9.0 IPLV - 3.1 _ 2.0 • E•ui•ment is new installation or re•laces existin• equipment 4 -13 • Compliance with OSSC, effective 04/01107 Form 5a Project Name: Tigard Senior Center Page: f 3 LIGHTING - GENERAL • 1. Interior Exceptions (Section 1313.1) CI No interior Lighting. The building plans and specifications do not call for new or altered interior lighting. Skip to item 5, Exterior building Lighting - General, below. Exceptions O Exceptions. 1. The building or part of the building qualifies for an exception from code lighting Olscusskin of Qualifying exceptions requirements. Applicable code exception is number. In Instructions section. 2. Lighting equipment that qualifies for an exception - in addition to general lighting and is separately controlled. Applicable code exception is number. Areas of the building and equipment mat quality for any exceptions: Plans /Specs Slow oomplianoe by Including a drawing sheet, detail number, and/or spednretlan section and 2. Local Shut -off controls (Section 1313.3.1.1) m Complies. At least one local shutott lighting control for every 2,uuu square feet of lighted floor area and for all spaces enclosed by walls or ceiling height partitions. This control is detailed in the building plans on drawing number. O Exception. I he building or part of me building qualities for an exception. Applicable code exception is Section 1313.3.1.1, Exception: Portions of the building that qualify: 3. Automatic Shutoff Controls (Section 1313.3.1.2) la Not Applicable. Office floor area is not over 2,000 square feet of contiguous office floor area or • permitted space is not over 5,000 square feet. No offices less than 300 square feet, meeting or conference rooms, or school classrooms. O Complies. All interior lighting systems are equipped with a separate automatic control to shut off lighting during unoccupied periods. Offices less than 300 square feet, meeting and conference rooms, and school classrooms are equipped with occupancy sensors that comply with Section 1313.3.1.2.1. Compliance details in plans/specs: O Exception. I he building or part of the building qualities for an exception. Applicable code exception is Section 1313.3.12, Exception: • Portions of the building that qualify. • 4. Daylighting Controls (1313.3.1.3) la No classrooms or atriums with skylights or window to wall ratio greater than 50 %. . 0 Complies. All classrooms and atriums with window to wall ratio greater than 50% and/or skylights are equipped with automatic daylight sensing controls, as required by Section 1313.3.1.3.1 and Section 1313.3.1.3.2. The daylight sensors specified comply with Section 1313.3.1.3.3. Compliance details in plans/specs: Exterior (Build -ing 5. Exterior Lighting (Section 1313.5) Lighting ® Complies. I he plans do not call for use of incandescent or mercury vapor lamps ror use on building extenor. Is lighting directed to illuminate the Exception. I he building plans indicate luminaires with incandescent or mercury vapor lamps, but are adador of the building and ad)acerd O walkways and loading areas with or specified for use in or around swimming pools, water features, or other locations subject to requirements "di 0td canopies. . of Article 680 of the 2002 National Electrical Code. Clock Switches that be astronomic (seasonal calecting) type e a` each da' ft. Exterior and Canopy Lighting Controls (Section 1313.3.2) of the week to maintain timetreeptrlg during; power ® Complies. The building plans and specifications include photoelectric and/or dock switches on all exterior outages. lighting systems which are designed and programed to extinguish lights when daylight is present, as required by Section 1313.3.2. 7. Connected Lighting Power (Section 1313.4) • YES (Complies. The lighting power does not exceed the power allowance established in either the Tenant Space Method (Form 5b) or the Space-by-Space Method (Form 5c). x } CTenant Space Method (Form 5b) ESpace-by-Space Method (Form 5c) / re; dNkm; ►� Compliance with OSSC. effective 01/01/05 i Form 5c Project Name: Tigard Senior Center Page: 1 1 INTERIOR LIGHTING POWER - Space - by - Space Method light Power I 6,566 Budget 1. Total Interior Lighting Power Budget from Worksheet 5b-1 (Sum of Column (I)) 1Yaek 2. Total length of track lighting (ft) Liting Power 3. Una 2 multiplied by 50 Watts/ft 4. Total amperage of circuit breaker(s) serving track lighting (amps) 5. Voltage of circuit breaker serving track lighting (volts) 6. Maximum wattage of track lighting (multiply line 4 by line 5) 7. VA rating of the inline current limiter or the low voltage transformers 8. Track Lighting Power (line 7 or the lesser value of line 3 and line 6) Building's Interior 9. Total Interior Lighting Power from Worksheet 51 )-1 (Sum of Column (m)) + 2,229 Lighting Power _ 10. Total Adjusted Lighting Power (line 8 + line 9) - 2,229 11. Does interior Lighting Design Meet Budget? Line 10 must be no greater than line 1. YES • Exterior Canopy parking Garage 12. Do Exterior Canopies Meet Budget (Worksheets 5c)? YES • '.:'; Lighting Power 13. Does Parking Garage Meet Budget (Worksheets Sc)? NIA • 14. Does Each Space With Retail Display Lighting Meet Budget (Worksheets 5d)? Y E S .;; • Retail Display Lighting Power 15. is The Total Retail Display Lighting Additional Power Less Than 17,500 W (sum of line 9 on Worksheets Sd)? YES 16. Does Retail Display Lighting Meet Budget? ...--'") 5.3 Compliance with OSSC. effective 01/01/05 Workst Project Name: Tigard Senior Center Page: / S LIGHTING FIXTURE SCHEDULE (see Table 5c in instructions for default luminaire power). (a) (b) (c) (d) (e) ( Lum Luminaire Is Luminaire ID Luminaire Lamp Ballasts Power From Type Description No. Description No. Description (watts) Table 5c A Fluorescent T8 - 4 foot 2 -F32T8 -ELECT NO-62W J 2 F32T8 1 Electronic Normal Output. RS 82 YES F Compact Fluorescent Twin 2- CFT5W /G23 -MAG STD -18W -1 2 CFT5w /G23 2 Magnetic Standard 18 YES Dl Track Lighting J – – – 50 YES C I Compact Fluorescent Triple j 1- CFTR26W /GX24q -3- ELECT -28W J 1 CFTR26W /Gx24q - 1 Electronic 28 YES H ( Long Compact Fluorescent Twin - T5 (40W) 3FT40W/2G11- ELECT -107W d TR 3 T4OW/2G11 2 Electronic 107 YES C1 Compact Fluorescent Triple — 1- CFTR26W /GX24q- 3- ELECT -28W ■ 1 CF26W /GX24q -3 1 Electronic 28 YES s Compact Fluorescent Twin . 9 W, G23 Two Pin Base - F9TT Lamp YES 1 Fluorescent T8 -4 foot r. 2 -F32T8 -ELECT NO-62W 2 F32T8 1 Electronic Normal Output RS 82 YES J1 Fluorescent T8 - 4 foot 2 NO F32T8 1 Electronic Normal Output. RS 62 YES C2 Compact Fluorescent Triple 2- CFTR26W /GX24q- 3- ELECT -55W • 2 CFTR26W /Gx24q - 1 Electronic 55 YES J A 1 1 I J 1 : _., ...., . . _ _,... I J - _ - - _ J I I LightingForms- V2.4.0_07014.xls • r Worksheet 5c ProJed Name: I Nerd Senior Center I Pagel 16 EXTERIOR CANOPY AND PARKING GARAGE LIGHTING POWER Exterior Canopy Lighting . (I) (6) (c) (a) (10 • . (9) 01) 0) 0) • (0l. M , Um ID kora Roan Arn nm (do e Speer Type Meet wan...) aa WnG eor( Mae Lumina. Emmet Pcwr (9) Room Tdffi Maw any Write) 0) • Ceropy LPD a)a( ' ( )awn (a) fL for track Vag) Pore (Wets) FtWs a 6 - Ltg. Power Each room es Caopls Uroa 15 W 11 ealgie 13 129 C2 2 26 0 66 - most be . _ • _ - 0 • _ Identified - Darrs Whim s - - - 0 - - ow i d`nrt rams In mega - - - 0 - - - - - 0 - - - - - 0 - - Pa Ina wane Inter . _ - - 0 - - Irma lraneunn ceaaar (q. mm ram a - - - 0 - - Oman O)kr ach man - - - 0 - - aryOSOa gat aayea - - , - _ ro roa m n. See In heac6aa. _ _ - 0 - - - - - 0 - — — — 0 - - 66 Taal Eaanr Grapy Budget in Total E>ash Ca opy Lighting Pow (arctdrg aryl roam) 66 Parking Garage Lighting (a) (6) (a) " (d) . a) (9) m) () 0) (k) Ughtrg Pura Gan 0 am Maretyd 09/ Raw Maw may (brio) Arab Perking Perking Garage SW* - n(d w n (s) a kr a yNg) Pore (Watts) FDmao Pa l91 Ltg. Pry Maw ay Writs) ( a r l - - - 0 - - - - - 0 - - - 0 - — • — — - 0 - - - — - 0 • - - - - • 0 - — — — - 0 - - - — - 0 - - - — - 0 - - - — - 0 - — _ — - 0 - _ — — - 0 - — ' — — - 0 - — — - 0 - — Total Part tg Garage � - • TOMI Pakhg Gams LIWag Plana yodeling amrp Reese) - . - • Does Canopy Ughting.Pov er Comply? YTS Does.Parking Garage Lighting Power Comply? N/A s-e Worksheet 5d-1 Project Name: I TI4M0 SP- • ccl &P Page: 11 Retail Display Lighting Power Complete one worksheet for each room (space) for retail display lighting that is specifically directed to highlight merchandise, and is controlled separately from the general lighting system within the room. General lighting should be included on Worksheet 5b. 1. Room 0 or Space ID 204 • 2. Room Area (ft) 300 3. Retail Space Type Retail - Other Merchandise Sales Area (b) (C) (d) Lum ID from Quantity of Lighting Worksheet 5a Luminaires (or lineal Luminaire Poser (b) Describe luminaires Column (a) ft. for track lighting) Power (Wefts) x (c) for each Individual _ - room In piano. For hack lighting X 3 28 84 eider lineal feet in C 1 62 B2 column (b). C1 1 28 28 • • f. Space Display Lighting Power (total d column excluding track fixtures) 174 2. Total length of hack Opting (R) 0 3. Line 2 muOipOed by 50 Watts/ft 4. Total amperage of dnarit breaker(s) serving back lighting (amps) 5. Voltage of circuit breaker serving track lighting (volts) 6. Maximum wattage of back fighting (multiply tine 4 by line 5) 7. VA rating of the bete current funiter or the loci voltage transformers 8. Track Lighting Power (line 3 or the lesser value of tine 6 and line 7) 9. Total Sperm Display Lighting Power (Watts) (line 1 + tine 8) 174 10. Total Space Display Lighting Power Budget (Wafts) (room area x 1.75 to max of 17,500) 525 11. Does Space Retail Display Meet Space Budget (Line 9 less than line 10 and loss than 17,000 W)7 YES Total Number of Additional Worksheet 5d I 0 j I I CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2007 -00E02 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/2012007 Phone: (503) 639 -4171 / Inspection Requests (24 Hrs.): (503) 639 -4175 `__., INSPECTION WORKSHEET FOR DATE: 4/7/2008 TIME: 7:01AM PAGE: 38 SITE ADDRESS: 08915 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: TI and addition OWNER: TIGARD, CITY OF, PHONE #: public w orE.r 503.7' CONTRACTOR: KEL TEC BUILDERS PHONE #: 925-229-5508 Inspection Request Scheduled For: Date: 4/7/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 299 Final inspection 067911 -01 360721 -8839 N Corrections /Comments /Instructions: 6( ..........., `LV 'ASS / RTIAL APPROVAL � ❑ NO ACCESS 111 FAIL ,%CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: Date: '0/ Phone #: (503) 718 -4‘ 7 APR - 07 -2008 MON 12 :57 PM CARLSON TESTING INC. FAX NO. 503640954 P. 02 • Carlson Testing, Inc. P ,� :; u : �� ° ; al l Construction Materials Testing & Inspection Fu 003) 9144954 i �suua+h%1s� Rot (511,113174143 Special Inspection FINAL SUMMARY LETTER April 7, 2008 ' T0706229 City of Tigard 13125 SW Hall Blvd Tigard, OR 97223 -8199 Attn: Building Department • Re: Tigard Senior Center — Addition 8815 SW Omara Street Tigard, OR Permit No.: BUP2007 -00502 Dear Sir or Madam: This is to certify that in accordance with Section 1704.1.2 of the International Building Code, we have performed special inspection of the following item(s) per our inspection reports only: Reinforced Concrete Installation of Cast in Place Anchors and Adhesive Anchors • All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested/inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON TESTING, INC. • ven W. Leach Project Manager SWUrc cc: City of Tigard Public Works -- Dennis Koellermeier City of Tigard Building Division LRS Architects Inc — Peter Dixon Kel-Tec Builders Inc — Steve Rutkowski • • CITY OF TIGARD , BUILDING DIVISION PERMIT #: BUP2007 -00502 13125 SW Hall Blvd., Tigard, OR 97223 ■ DATE ISSUED: 1 Phone: (503) 639 -4171 A l Inspection Requests (24 Hrs.): (503) 639 -4175 `- I.. INSPECTION WORKSHEET FOR DATE: 4/3/2008 TIME: 7:02AM PAGE: 57 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: TI rand addition OWNER: TIGARD, CI OF, PHONE #: public works 503.7' CONTRACTOR: KEL TEC BUILDERS PHONE #: 926.229 - 5508 Inspection Request Scheduled For: Date: 4/3/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 299 Final inspection 067776 -01 360 -721 -8839 N Corrections/Comments/Instructions: Z Mb fr-NSr( i=o t-1.--o 1.-//r._/1-27 /4--R_ C-'- O PC_� -) i > C_ -- iZd`1 I i < - Al C Sr 7.067 — Ov0Z‘ LZZ,_ 2©o — cz•o ' imif.1111ra — c, c= , _ MS' eb •xra'e.A sAv . am. liffAsi Sr ❑ P �; =- PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS s!% AI 7/4 CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: Date: I S v" Phone #: (503) 718 -Z // a CITY OF TIGARD • BUILDING DIVISION PERMIT #: RUP2007 -00502 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/26/2007 Phone: (503) 639 -4171 M � Inspection Requests (24 Hrs.): (503) 639 -4175 ' I L. INSPECTION WORKSHEET FOR DATE: 3/31/2008 TIME: 7:01AM PAGE: 25 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FAI4NO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: TI and addition OWNER: TIGARD, CllY OF, PHONE #: public Works 5503 -7' CONTRACTOR: KEL TEd BUILDERS PHONE #: 926 Inspection Request Scheduled For: Date: 3/31/ 2008 Pour Time: Code # Inspection Description Confirm # Contact # Mess- - - ii::i Mk c. inspection 067564.01 .360773-4988 6:04:06 Corrections /Comments /Instructions: Sin rt%/ L Po')) LA> PC-5S O�.. i fz T' °. C< V iar l i0 PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: Date: �,7S i- (O 8 Phone #: (503) 718- Z4-1. CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2007 -00502 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 1 1/26/2097 Phone: (503) 639 -4171 / I��I Inspection Requests (24 Hrs.): (503) 639 -4175 '_ INSPECTION WORKSHEET FOR DATE: 3/31/2008 TIME: 7:01AM PAGE: 18 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FAWN() CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: TI and addition OWNER: TIGARD, CITY OF, PHONE #: public world; 503 CONTRACTOR: KEL TEC BUILDERS PHONE #: 925-229-5608 Inspection Request Scheduled For: Date: 3/31/2008 Pour Time: Code # Inspection Description Confirm # Contact # Messa•e trC. 299 Final inspection 067581 -01 360773-4988 7M Corrections /Comments /Instructions: F Su N1 / . FR k)6 - 1 rfzT t=om v� , r-JG� •4 -�c� c3 Pt��➢.1 r�G12.i - c l - R1.1 tom 1? 2 ° 'z - -r-0 L--7 r J L-t r—, Ai 14-t__— S Zo c) — o c o 311 ?oP Zoo, - ooae:,f3 LZr---Zooe; - c c, o 8 i oP Zoo'7 - Z Pe..-/t1 Zoo 7- oa,S r Z007 - ex? 7o 1 -5--c-- - N sr! S,E r—T?c ❑ PASS %, PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS edirloo," 11 CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: _ Date: Cc /S Vo8 Phone #: (503) 718 -Z- � CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2007 -00.02 13125 SW Hall Blvd., Tigard, OR 97223 /' DATE ISSUED: 11/26/2007 Phone: (503) 639 -4171 /anvil 1 Ii Inspection Requests (24 Hrs.): (503) 639 -4175 id INSPECTION WORKSHEET FOR DATE: 3/17/2008 TIME: 7:01AM PAGE: 2 SITE ADDRESS: 08816 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: TI and addition OWNER: TIGARD, CITY OF, PHONE #: public: works 503-7' CONTRACTOR: KEL TEC BUILDERS PHONE #: 925-229-5508 Inspection Request Scheduled For: Date: 3/17/2008 Pour Time � 7 P� y Code # Inspection Descripti ciL Confirm # Contact # Mes- - • 6 s , 285 Drywall nailing 066B14 -01 503 - 881 -5364 l' 41 v)I Corrections /Cor ments /Instructions: f t. 1 , tl _ ./ 74 l,. " A . __ ____ , 1 , ju i___ .___ 0,_ ,,_ , _ , . a Ak, i 1-e., 0 Lt.),L Kir- e____ tiv..4.? • , •, PASS ❑ PARTIAL APPROVAL ❑ CANCEL • ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED ,, Inspector: v + Date 6 \ � / Phone #: (503) 718 - l CITY OF TIGARD ' BUILDING DIVISION PERMIT #: BUP2007 -00602 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11126/2007 Phone: (503) 639 -4171 � .. Inspection Requests (24 Hrs.): (503) 639 -4175 , L. INSPECTION WORKSHEET FOR DATE: 3/13/2008 TIME: 7:02AM PAGE: 1 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: TI and addition OWNER: TIGARD, CITY OF, PHONE #: public works 503 CONTRACTOR: KEL TEC BUILDERS PHONE #: 925-229-5508 Inspection Request Scheduled For: Date: 311312008 Pour Time: Code # Inspection Description Confirm # Contact # Message 23( Shear wallehanrhors 066669-01 50'3.881 -5364 N Corrections /Comments /Instructions: i : ,,,, !. f iii _A1AA _ .l C ki C-( M 0 A d4 01( VII /rt., c- , MI 5 401- / ❑ PASS PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: 1141.3 Date: "// 0 Phone #: (503) 718- ( CITY OF TIGARD f - BUILDING DIVISION 1 PERMIT #: 8UP2007 -00502 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11 /26/2007 Phone: (503) 639 -4171 • �� j14 Inspection Requests (24 Hrs.): (503) 639 -4175 INSPECTION WORKSHEET FOR DATE: 3/12/2008 TIME: 7:00AM PAGE: 60 SITE ADDRESS: 08816 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: 11 and addition OWNER: TIGARD, CITY OF, PHONE #: public works 503-7' CONTRACTOR: KEL TEC BUILDERS PHONE #: 925 - 229 -65013 I Inspection Request Scheduled For: Date: 3/1212008 Pour Time: Code # Inspection Description Confirm # Contact # Messase 2 Insulation 066514 -02 503-881 -5364 4110 Corrections /Comments /Instructions: PkSE. 0 '‘ P ASS ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITION FEES ASSESSED Inspector: _`�� // Date: t / l 6 8 Phone #: (503) 71 8 -2 3 , 9 i�re; . CITY OFTIGARD BUILDING DIVISION PERMIT #: t3UP2007 -00502 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/26/2007 Phone: (503) 639 -4171 ,1 g i Inspection Requests (24 Hrs.): (503) 639 -4175 ' W 1 .. INSPECTION WORKSHEET FOR DATE: 3/12/2008 TIME: 7:00AM PAGE: 61 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: TI and addition OWNER: TIGARD, CITY OF, PHONE #: public works 503-7 - CONTRACTOR: KEL TEC BUILDERS PHONE #: 925- 229 -5508 i Inspection Request Scheduled For: Date: 3/12/2008 Pour Time: Code # Inspection Description Confirm # Contact # Messa.e 275 Framing - ? t om 066514 -01 503 - 881-5364 '#11PP 1 3d Corrections /Comments/ Instructions: M0 - - Ad, 0 d v . l1 I . Pi „ - 4-L A-Al c7-E 2S - Z-SS c - ` - :,.F — !I f I 6 () /-u65 C --- 141F-A or T STp F t R r .0-ge-2tEr____T- T cyzky , 1\z-- '5,*ef2- 1 4{116e `2 1 050 61444. idz PASS ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITION FEES ASSESSED Inspector: ' Date: r ' (/ S Phone #: (503) 718 7 CITY OF TIGARD , BUILDING DIVISION PERMIT #: BUP2007 -00502 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/26/2o:;7 Phone: (503) 639 -4171 1�°�-�pp I� Inspection Requests (24 Hrs.): (503) 639 -4175 !'J INSPECTION WORKSHEET FOR DATE: 2121/2008 TIME: 7 :00AM PAGE: 23 SITE ADDRESS: 08816 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FAWN( CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: TI and addition OWNER: TIGARD, CITY OF, PHONE #: pub ir: works 503-7' CONTRACTOR: KEL TEC BUILDERS PHONE #: 925-229 -t50$ Inspection Request Scheduled For: Date: 2/21/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 299 Final inspection 065389 -01 503881 -5364 N Corrections /Comments /Inst uctions: /1�la �-- 4 v - ",riL IC Z .6 Mli f - OUP c_eyl-t PL ,t -A 1 7 1 4-71 >2 la" ii C FA 4-fC j let , e. iv f e l -r Y ' - A . ,_ o r . - ;. ,, v(41.- 7 - r7 M c. (/ `To /�4- --9/ MA/ ti,ft Rooi - 4 /_I ► see _ ❑ PASS !T IAL ❑ CANCEL III NO ACCESS ❑ FAIL C • L FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: I.__...... _ Date: Z l Phone #: (503) 718 - Z—C_____LW" CITY OF TIGARD . BUILDING DIVISION PERMIT #: RUP2007 -00502 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/26/2 0{)7 Phone: (503) 639 -4171 ri Inspection Requests (24 Hrs.): (503) 639 -4175 "'I I.. INSPECTION WORKSHEET FOR DATE: 2/181200 TIME: 7:01AM PAGE: 32 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: TI and addition OWNER: TIGARD, CITY OF PHONE #: public: works: 603-7' CONTRACTOR: KEL TEC BUILDERS PHONE #: 925-n9-5508 Inspection Request Scheduled For: Date: 211912008 Pour Time: Code # Inspection Description Confirm # Contact # Messa• - pNnse -i 299 Final inspection 06 -r_p W Corrections /Comments /Instructions: 4 4 6 irrAt ..44bil .4-&- WAgli ,' 0) 4. L , (__ X. Aral _ „ L..)i , -/l ' -__ 1 1 /L— ' v V! cA rr - % A - >�7� L�1/Z — AA i t c___ i�l ' L--) 4 'IZ . V .., 45 ta Ar al C_ • PASS /I PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS gW VI CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED zi Inspector: - Date: 11 [ 1)6 Phone #: (503) 718-6 CITY OF TIGARD • BUILDING DIVISION .. .,. ... . . PERMIT #: BUP20 )7 -00502 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/260)007 Phone: (503) 639 -4171 1 Inspection Requests (24 Hrs.): (503) 639 -4175 alt .. INSPECTION WORKSHEET FOR DATE: 2/19/2008 TIME: 7:01AM PAGE: 40 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: TI and addition OWNER: TIGARD, CITY OF, PHONE #: public works 503-7' CONTRACTOR: KEL TEC BUILDERS PHONE #: 925 - 229 Inspection Request Scheduled For: Date: 2/19/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 73 Shear walls/anchors 085160-01 503-881 -5364 N Corrections /Comments /Instru tions: gc_T i--- /Q41 (/ Ai (i c._____ , 4-re's c2K......._ : �ai,�,JJ �' .,44i_ = d _ Sj__1 tr 1 T ❑ PASS j "' ' . • • • - .1 ' ❑ CANCEL ❑ NO ACCESS ❑ FAIL • CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED / z 1 `/9 Ph one #: 503 L� Inspector: Date: ( ) 718- CITY OF TIGARD BUILDING DIVISION r PERMIT #: 611P2007-00502 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11126/2007 Phone: (503) 639- 4171weogl i� Inspection Requests (24 Hrs.): (503) 639 -4175 � "_L INSPECTION WORKSHEET FOR DATE: 2/1912008 TIME: 7 :01AM PAGE: 39 SITE ADDRESS: U8815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: TI rm d addition OWNER: TIGARD, CITY OF, PHONE #: public works £03.7' CONTRACTOR: KEL TEG BUILDERS PHONE #: 925 Inspection Request Scheduled For: Date: 2119/2Q08 Pour Time: Code # Inspection Description Confirm # Contact # Message X50 Roof nailing 065160 -02 503- 881 -5364 N Corrections /Comments/ Instructions: '.1 o t lgo'ki c 4S P L�- - AWf - tG (A -- 1 ❑ PASS 0 • RTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL • C' OR INS' ' ON ❑ ADDITIONAL FEES ASSESSED Inspector: Date: 4 0 Phone #: (503) 718- zc CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2007 -00502 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/26/2007 Phone: (503) 639 -4171 Zit Inspection Requests (24 Hrs.): (503) 639 -4175 __- INSPECTION WORKSHEET FOR DATE: 1/17/2008 TIME: 7:00AM PAGE: a9 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: TI and addition OWNER: TIGARD, CITY OF, PHONE #: public works 503.7 CONTRACTOR: KEL TEC BUILDERS PHONE #: 925 - 229-5508 Inspection Request Scheduled For: Date: 1/17/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 285 Drywall nailing 063387 -01 503.881 -5364 N Corrections /Comments /Instructions: kip S 1 40 F7 26 1`.!r1Z -_ _114‘K,.-----(__(5 f S PARTIAL APPROVAL CANCEL El NO ACCESS IL /111 CALL FOR INSPECTION El ADDITIONA FEES ASSESSED Inspector: Date: //fl 14 Phone #: (503) 718- 06'1( CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2007- 00502 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/2G/2007 Phone: (503) 639 -4171 . avad Inspection Requests (24 Hrs.): (503) 639 -4175 W' i- INSPECTION WORKSHEET FOR DATE: 1/15/2008 TIME: 7:02AM PAGE: 37 SITE ADDRESS: 00815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: TI and addition OWNER: TIGARD, CITY OF, PHONE #: public works 503-7' CONTRACTOR: KEI_ TEC BUILDERS PHONE #: 925 - 5508 Inspection Request Scheduled For: Date: 1/15/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 275 Framing 0632240/ 503.881 -5364 N Corrections /Comments /Instr ctions ,O - 1 (—e � 1 1 PASS % 'ARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL P CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: 4 , 1 / Date: U 6 Phone #: (503) 718 - r Tr/ 41111■ CITY OF TIGARD • BUILDING DIVISION PERMIT #: BUP2007 -00502 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/16/2007 Phone: (503) 639 -4171 t J o, Inspection Requests (24 Hrs.): (503) 639 -4175 .... - ' L G INSPECTION WORKSHEET FOR DATE: 1/11/2008 TIME: 7:01AM PAGE: 69 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: Ti and addition OWNER: TIGARD, CITY OF, PHONE #: public works 503-7' CONTRACTOR: KEL T EC BUILDERS PHONE #: 925 -229 -5508 Inspection Request Scheduled For: Date: 1/11/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 275 Framing 062988 -01 503 -1381 -5364 N Corrections /Comments /Instructions: VV V- 6--L-7-, /■ L-4 1 3- /0-4/■_ - LC - ?--- - y'‘- t--■C.---- e ..------- Aie 3 `fir t 1,--1.--,--- .-- Vik -- .a.,J--. - . C A e.-- .. Ai-e 471--.e c 4 "L-itik-c._ C "4-7.A.„." toi-e--_s . S & e °- - S. D'A i / tk -Q6. i I 0 ' ii, I kit...A.".■■• ' As. 1 ti --- G ❑ PASS PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: Wj?_____ - ?"( Date: \ / ( Phone #: (503) 718 - " - CITY OF TIGARD • . . BUILDING DIVISION PERMIT #: [3UP2007 O0 02 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/26/2007 Phone: (503) 639 -4171 V � Inspection Requests (24 Hrs.): (503) 639 -4175 . fi '� I.. INSPECTION WORKSHEET FOR DATE: 1/11/2008 TIME: 7:01AM PAGE: 68 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER • DESCRIPTION: TI and addition OWNER: TIGARD, CITY OF, PHONE #: public works 503 -7' CONTRACTOR: KEL TEC BUILDERS PHONE #: 925 D Inspection Request Scheduled For: Date: 1/11/2008 Pour Time: C9,00 Code # Inspection Description Confirm # Contact # Message 205 Footing 062980.02 503-881-5364 N Corrections /Comments /Instructions: Ak MA) • ,. .... l 6 > - C *c-i . ,s 1,--,,,,A 4' tlt dr 2� 4 S 't , i r- - e D i p ❑ PASS PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: /( v v Date: V (`/trr Phone #: (503) 718- �� 2Zr CITY OF TIGARD - BUILDING DIVISION PERMIT #: BUP2007- 00502 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/26/2007 Phone: (503) 639 -4171 • Auon Inspection Requests (24 Hrs.): (503) 639 -4175 "' i �.. INSPECTION WORKSHEET FOR DATE: 1/1112000 TIME: 7 :01AM PAGE: 67 SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: TI and addition OWNER: TIGARD, CITY OF, PHONE #: public works 5U3-7' CONTRACTOR: KEL TEC BUILDERS PHONE #: 925 - 229 -5508 Inspection Request Scheduled For: Date: 1/11/2008 Pour Time: 9:00 Code # Inspection Description Confirm # Contact # Message 2 �0 Slab 062988-03 503 -881 -5364 N Corrections /C mments/lnstructions: L ' ? ‘e-sjirl.-e---'R-- ( --e f •- c..,e__ v-v----1.--/\-----t 42 S t 5 7, . k 6 ,-- 6 4 (- A l k/k.. - ‹ t-Sce . ,,,,. A � � 1 4- 5 1 ❑ PASS PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: V6 Date: ) A \/ D Phone #: (503) 7182 T T CITY OF TIGARD , , BUILDING DIVISION PERMIT #: 13�1P2Ot17 -00502 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 11/26/2007 Phone: (503) 639 -4171 . Ae. ..11 ` / Inspection Requests (24 Hrs.): (503) 639 -4175 .... J' F' I � I INSPECTION WORKSHEET FOR DATE: 1/10/2008 TIME: 7:32AM PAGE: 3 • SITE ADDRESS: 08815 SW O'MARA ST CLASS OF WORK: SUBDIVISION: FANNO CREEK PARK LOT #: TYPE OF USE: PROJECT NAME: SENIOR CENTER DESCRIPTION: TI and addition OWNER: TIGARD, CITY OF, PHONE #: public work. 503.7' CONTRACTOR: KEL TEC BUILDERS PHONE #: 925- 229-5508 Inspection Request Scheduled For: Date: 1/11/2008 Pour Time: 9 Code # Inspection Description Confirm # Contact # Message 220 Slab 062988-03 503. 881 -5364 N Corrections /Comments/ Instructions: r. b•INQ ..,■---2---tr.-. . s ZT _.-e--A----j:,-- IC( ❑ PASS ❑ PARTIAL APPROVAL 'n CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: Date: Phone #: (503) 718-