Loading...
Specifications F-As g ro 9 - Q-crro 7 ?>4 °z2 0-Lk S.t- RECENED OR 21 200 1116 CTTY GILD IN O N . BU Western States Fi Protection Co. Floteete#19 46ije4 arm plofteret Fire Alarm System For Plaza West Portland OR INTELLIKNIGHT FIRE ALARM CONTROL PANEL { - IntelliKnight® Model 5820XL y Addressable Fire Alarm , Control System ; i . • I I The IntelliKnight System is the easy way to make the most of fire alarm f t` technology. C,. IntelliKnight 5820XL is the first fire alarm system to provide you with ' revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built -in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 1- 800 -446 -6444, or in Minnesota, call 763 -493 -6435. Description • Improvements in SKSS software 5820XL performs drift compensation deliver five times faster and calibration checks on each of the uploads /downloads I - — — sensors in the system. • Two built -in Form C programmable • The basic 5820XL system can be VDClays rated at 2.5 amps at 27.4 expanded by adding modules such as • Supports sounder bases 5860 remote annunciator, 5815XL • 6 amp power supply and maximum a a 1.' signalling line circuit expander, 5824 charging capacity of 35 amp hours • ?° a serial /parallel printer interface module (An additional cabinet enclosure is a ) (for printing system reports), and required for batteries in excess of 18 5895XL intelligent power module. amp hours) r i 5820XL also features a powerful built -in • Programmable date setting for dual line fire communicator that allows Daylight Saving Time for reporting of all system activity to a • Plex -1 door option combines a dead . • remote monitoring location. front cabinet door with a clear ( • • . ••.•.' .•••- window, limiting access to the panel Features while providing single button operation of the reset and silence ,. • Up to 508 addressable points functions >t • Uses standard wire —no shielded or twisted pair required Electrical Specifications • Built -in digital communicator Primary AC: . • Central station reporting by point or 120 VRMS at 50/60 Hz, 2.5A or by zone 240 VRMS at 50/60 Hz, 1.4A Model 5820XL • Built -in synchronization for Total Accessory Load: 6A @ 27.4 VDC, appliances from AMSECO ®, power - limited Overall Dimensions: Gentex ®, Faraday, System Sensor, Standby Current: 215 mA 16.2 "W x 26.4 "H x 4.2 "D and Wheelock® • FlexpuP'' I/O circuits Alarm Current: 385 mA ( 40.6 W x 67 H x 11.8 D cm) • Supports Class B (Style 4) and Class Flexput Circuits: Six programmable Weight: 28 lbs. (12.8 kg) A (Style 6) configuration for SLC, circuits which can be programmed Color: Red SBUS, and Flexput circuits individually as: Battery Charging Capacity: 7.0 -35 AH • Distributed, intelligent power Notification circuits: 3A @ 27.4 VDC Battery Size: 18 AH max allowed in • Drift compensation per circuit, power - limited control panel cabinet. Larger capacity • 13 pre - programmed output cadences Auxiliary power circuits: 3A @ 27.4 batteries can be housed in RBB (including ANSI -3.41) and 4 VDC per circuit, power - limited accessory cabinet. programmable outputs Initiation Circuits: 100 mA @ 27.4 Telephone Requirements: • Built -in •annunciator with VDC per circuit, power limited FCC Part 15 and Part 68 approved 80- character LCD display Type of Jack: RJ31X (two required) • • RS-485 bus provides communication Mechanical Specifications to system accessories Flush Mount Dimensions: • Built -in RS -232 and USB interface for ' 14.5 "W x 24.75 "H x 3.9 "D SILENT programming via PC (36.8 W x 62.9 H x 9.8 D cm) ` KNIGHT • Built -in Form C trouble relay rated at 2.5 amps at 27.4 VDC by Honeywell INTELLIKNIGHT FIRE ALARM CONTROL PANEL i J IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel • ' Indicator Lights Flexput circuits on 5820XL control can required to start a new system. The General Alarm (Red): Flashes when in be individually programmed to function built -in keypad and 5860 remote alarm; solid when alarm silenced as notification circuits, auxiliary power annunciator give on -site access to all outputs, or initiation circuits that programming. You can also program Supervisory•(Yellow): Flashes when a support both 2- and 4 -wire smoke remotely using the 5660 Silent Knight 1 supervisory condition exists; solid when detectors. Software Suite, which is Windows® - supervisory silenced The 5820XL system operates on non- based software. System Troubles (Yellow): Flashes twisted, unshielded cable when wired when a trouble condition exists; solid in compliance with standard wiring Built Digital Communicator when trouble silenced practices as called out in the National 5820XL features a built -in UL listed Electric Code 760 -51 specifications for System Silenced (Yellow): On when an power - limited fire protective signalling digital communicator for remote alarm, trouble or supervisory condition reporting of system activity and system cables. No special wiring is required. has been silenced but not yet cleared 5820XL provides 13 preset notification programming. The communicator has System Power (Green): Flashes for AC cadence patterns (including ANSI 3.41) the ability to seize two telephone lines failure; solid when power systems are and four user programmable selections to report alarms and troubles to a normal for fire alarm notification. monitoring facility. The communicator Two programmable general purpose supervises two phone lines and will System Application Form C relay outputs are provided on activate a trouble signal if a line failure 5820XL. is sustained for more than 45 seconds. 5820XL has one built -in signalling line Other communication features include: circuit (SLC) which supports 127 Additionally, the IntelliKnight system retry if communication fails, two phone devices. Three additional loops can be features a built -in walk test and auto- number capability, download phone added using the 5815XL SLC programming. Its innovative, dead -front g number capability and Touch -Tone or expanders to increase overall capacity cabinet design allows for flush or rotary dialing. The communicator is to 508 devices. surface mounting. System maintenance compatible with SIA and Ademco . is easy to perform. Contact ID. The format is selectable b The 5820XL SLC loops support by multiple device types, including: User Interface account number. • Addressable photoelectric smoke The 5820XL built -in annunciator with ' detector 80 character LCD display and large R ,. • Addressable ionization smoke easy -to -use tactile touchpad can be - .....-1,-- • detector used for system operation, k .CI i I programming and maintenance. It has �. • i • Addressable heat sensor five LEDs for alarm, supervisory, • Addressable duct smoke detector system trouble, system silenced and ' 11- ie' iv system power. System operations �, iv nu tm f : l go' • Contact module Y P Y P I • Relay output module include silencing alarms and troubles, -- a 111! lie I 1.0' tr resetting alarms and the display of rr N ri“ • Addressable notification module alarm troubles and memory. The - - The following advanced sensor system's non - volatile event history capabilities are available with 5820XL: buffer stores 1000 events for viewing from the built -in or remote annunciator. Approvals • Automatic drift compensation System operation can be initiated with NFPA 13, NFPA 15, NFPA 16, • Maintenance alert a mechanical firefighter's key or a valid NFPA 72: Central Station; Remote • Built -in sensor test to comply with 4- to 7 -digit operator's code. Signalling; Local Protective Signalling NFPA 72 calibration testing Programming Systems; Auxiliary Protected Premises requirements The IntelliKnight system offers several Unit; & Water Deluge Releasing Service. Suitable for automatic, options to simplify and speed up 5820XL features a 6 amp power supply manual, waterflow, sprinkler and maximum battery charging programming. The JumpStart® feature minimizes programming supervisory (DACT non- coded) capacity of 35 amp hours. An additional cabinet enclosure (PN RBB) is required signalling services. for batteries in excess of 18 amp hours. Other Approvals: UL Listed; CSFM 7170 -0559: 135; MEA 429 -92 -E Vol. VI; FM Approved '' I INTELLIKNIGHT FIRE ALARM CONTROL PANEL 1 s IntelliKnight Model 5820XL 1111 A Addressable Fire Alarm Control Panel sera MS Windows-Erna Fai>Y La+ayomrw 6oMr;rc "� RS.i]1 Dt N'rt d I - -ti • C t y A Lir 8800 w 8500 A.rsnmun tiaGare 5820XL o �•a ? R bttr Uwua {Rew'�n akapan Perin Mod o . -:rcc ]Form CHuy )Fan C Rt1 ID 4 i I Evrt Printer _L ,I 5 5824 Re-uto Arnundator FatoriGelCAefLtoddo - - n u, : Aea..Sry em) "a IL 5815XL 5815XL II • � I s • i 5LC Error:4 ELC Er13•Wel p ; u am 6 Fle uttu fe El 8 C irca is VO Circu tt 1/0 O Circuits g can be inputs F Can bD inp uts or outputs � R � or outp � _:.: _ 0 E s a e'h S3olns. Ha•nt, a ^] N C., �. E. • _ E rj; 6 a i r P5:otro u Coms.lrxal 5....,1 t l 'vd Snook o OcaeUm V L ! - 1 P. 5496 '� f hateq!at Poae f LW.L.' SD505•APS S0505•AIS S05054513 SD505-AHS 50500SDM ;:E Adrdteafable MCetrtfa SGmo, Heise •MN MI Heise ACXt Heel Mee PMtooudx 131i3111 Detnolo• Smeta Mdp se Deer De tam, 5860 A r Rewte oluoux 8D505•DTS - f Rennin l� - 1- - � I • I . . � DuU Test SrDCh SD500•LED S0500 -AHM 50505-6R8 50505418 SD5054A6 5880 AO}ratsablr Addrr uWW Prtn as tsostrr B (303,3313t336 l70 Ut■ter 8 LEOD --rc Nwax,.+ Don leput LtadJ.o Ihd∎Ar — 0 El ' Mal r ik( 1 J 1 1 • ., Rola/ Welts Italic S0505-AOHR SD500 -PS 5D505 -ADH SDSOO.MIM 60500-ARM 613500•LIM A{Wroganpto DUtt AS:rosarrbe AdamtvNl M4]Ury Conan Mdre. A67rayaaoln Horning W;FlOSy PO Ratan D.un Dora- '.∎ Input Lladlo Relay LtadA LM[ Want imn or PrnVtlMI•k) Haar* Nxtdn LI, or Pint xvc kl r- 5885-4 or 5865-3 LED NevkValot I Use the 5880 to control up to 4 1 _ I33e51 S rl — 5883 Relay Interface Modules I J IntelliKnight 5820XL Addressable Fire Alarm Control Panel and Compatible Devices INTELLIKNIGHT FIRE ALARM CONTROL PANEL SLC Detectors SLC Modules 5880 LED/I0 Module t 5820XL devices feature a low profile SD500 -AIM Features 40 LED design and EEprom addressing. Dry contact input module for use with outputs, 8 normally EEprom addressing prevents water normally open dry contacts. It features open dry contact intrusion problems via the back of the an indicator LED to show alarm status. inputs, and one piezo sensor and eliminates mechanical SD500 -MIM output. f ^` failures related to decade switches. Mini dry contact input module is a small 5865 -3 and 5865 -4 SD505 -APS version of the SD500 -AIM. For use with Remote LED Annunciator Addressable photoelectric smoke pull stations and other normally open Features 30 programmable LED (15 detector. dry contact inputs. red and 15 yellow) outputs, and a piezo SD505 -AIS SD500 -ANM sounder. The 5865 -4 adds a silence Addressable ionization smoke detector. Addressable notification module and reset switch to the package. SD505 -AHS. providing a single Class A or Class B 5883 Relay Board Absolute temperature heat detector notification circuit on the SLC. Features 10 general purpose Form C that goes into alarm immediately if the relays. Used with 5880 module. 9 y SD500 -ARM temperature exceeds the Addressable relay module. Features 2 5824 Serial /Parallel Printer programmable trip point. Trip point Form C output relays. Provides Interface Module range from 135 °F - 150 °F(0 °C- 37 °C). indicator LED to show output status. Provides one parallel and one RS -232 SD505 -6AB SD500 -SDM serial port for connecting a printer to Six inch base for use with detector Two -wire detector input module. Allows the 5820XL. Use to print a real -time log heads SD505 -APS, SD505 -AIS, and for the connection of conventional of system events, detector status SD505 -AHS. 2 -wire detectors on the SLC loop. reports, and event history. Interfaces SD505 -4AB Requires two additional wires for with building control system. Four inch base for use with detector power. Miscellaneous Accessories heads SD505 -APS, SD505 -AIS, and SD500 - LIM 5660 Silent Knight Software Suite SD505 -AHS. A short circuit isolator module for SLC (SKSS) SD505 -6SB devices. When a short occurs on the User - friendly Windows software for Six -inch sounder base for use with SLC loop, it is detected as a trouble, remote programming of 5820XLs using existing sensor and base. Operates in but all SLC devices protected by the a PC. Upload and view panel account single and multi- station modes and /or isolator module continue to operate. information, event history, and detector as a system sounder. Requires 2 SD500 -LED status. additional wires for power. An LED driver module capable of 5670 Silent Knight Software Suite SD505 -61B driving 80 LEDs. Use up to 40 modules (SKSS) - Six -inch isolator base for use with per SLC loop and up to 100 Powerful end -user facility management existing base and the SD505 -APS, SD500 -LED modules per system. software allows viewing of detector SD505 -AIS, and SD505 -AHS sensors. status and event history via modem or • Provides isolation for style 7 circuits. S - BUS Accessories direct connection. SD505 - 6RB 5860/R Remote Fire Annunciator Plex-1 Six -inch relay base for use with existing Features the same 80 character backlit Dead front cabinet door with clear sensor and base. Provides one Form C LCD display keypad and firefighters window to limit access to the FACP. contact. keyswitch as the 5820XL. 5860 is gray SD505 - ADH and 5860R is red. RBB 5815XL Signal Line Circuit Expander Remote battery box accessory cabinet. Duct housing that detects smoke in Use if backup batteries are too large to HVAC ducts. The SLC expander is used to add more addressable devices to the IntelliKnight fit into FACP cabinet. Dimensions: SD505 -ADHR 16 " W x 10 " H x 6" D Duct detector base with relay. Provides system.. Each 5 815XL can support supports tnr 5815XLs. Each (406 mm W x 254 mm H x 152 mm D) 15XL u Form C alarm contact. For use with 127 devices. SD505 -DTS SD505 -APS and SD505 -AIS sensors. 5895XL Intelligent Power Module Remote test switch. Used with Compatible with SD505 -DTS remote SD505 -ADHR. Provides remote key Adds 6 amps of power, 6 Flexput I/O test switch. operated test function and annunciation SD500- PS /SD500 -PSDA circuits and 2 Form C relay circuits to a of detector alarm. SD500 -PS is a single action pull station 5820XL system. and SD500 -PSDA is a dual action pull 5496 Intelligent Power Module station. A 6 amp notification power expander that provides four power - limited notifi- cation appliance circuit outputs. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up- to-date and accurate. We cannot cover all ` specific applications or anticipate all requirements. All specifications are FORM# 350210 Rev E, 04/06 - c subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, MN 55369 -4927. Copyright © 2006 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. • IntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight INTELLIKNIGHT ACCESSORY • 5860 Remote Annunciator ti i t ,- Bring the power to control an lntelliKnight r fire alarm control panel to every area within your facility. 1 Now you can operate and program your lntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy -to -use interface found on the lntelliKnight panel's built -in annunciator. The 80- character display and ergonomically designed keypad allow for simple and error -free system operation. All operations — including reset, silence, detector status checking, fire drill, and programming —are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the lntelliKnight panel via the RS -485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the lntelliKnight system, or to locate your nearest source, please call 1- 800 -446 -6444, or in Minnesota, call 763 -493 -6435. Description • Available in red or light gray Features include an 80- character • Support for simultaneous use of backlit LCD providing easy -to- multiple 5860s - – understand system messages. The • RS -485 interface to panel . annunciator is ergonomically • Operation and appearance is designed with over -sized buttons identical to 5860 built -in ii, annunciator X ` ` for the most frequently used t_111,2 6., .4 features, like Reset and Silence. • On -board piezo sounder audibly =m ■ In addition to status messages indicates alarms, troubles, and ;1 :..1 i supervisories displayed on the LCD, there are • Five status LEDs for alarm, five LEDs for alarm, supervisory, supervisory, trouble, silence and trouble, silence, and AC power AC power conditions 5860 status. • Wiring lengths up to 6000 ft. from The annunciator is available in gray the FACP (depending on wire Color to match virtually any decor and gauge and number of devices on 5860R: Red red for applications where the SBUS) 5860: Gray • annunciator must stand out. The UL listed, complies with NFPA 72 Environmental annunciator enclosure can be • CSFM approved Operating Temperature: 32 °F – surface or flush mounted. A trim Electrical Specifications 120 °F (0 °C – 49 °C) ring kit is available for surface Operating Voltage: 24 VDC Humidity: 10% – 93% non - mounting. Standby Current: 20 mA max condensing Features Alarm Current: 25 mA Approvals • 80- character backlit LCD display Wiring Distance: 6,000 max. from NFPA 72; UL Listed; (4 lines with 20 characters on FACP (depending on wire gauge CSFM 7170 -0559: 135; each line) and number of devices on the MEA 429 -92 -E Vol. IX; • Tactile and audible feedback SBUS) FM Approved • Accepts user codes or fire System: 8 Max Per S - fighter's key Y • Larger keypad buttons for system Mechanical Specifications SILENT reset and silence Physical 9.1" W x 7.4" H x 1.5" D l ! KNIGHT ▪ • Install up to eight 5860s per (23.1 W x 18.8 H x 3.8 D cm) FACP Shipping Weight: 2.8 lbs (1.3 kg) by WQntivt' INTELLIKNIGHT ACCESSORY 5860 Remote Annunciator it Engineering Specifications The main control must have a built -in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built -in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built -in annunciator. All annunciators must have an 80- character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Rums Up to 8lldit1 :feet From fACIP _ _ �_. "AIL — - . —m_ p: :44.- _ a 4. ` VW BtJS •.•• 51360 5690 mg r Ur5 to Eight SE:505 Per System Carrtpptlbts, Int.f1IKnmgt$ FRCP Compatibility Ordering Information Accessories IntelliKnight 5820XL FACP 5680R Remote Annunciator 5860TR Red Trim Ring IntelliKnight 5808 FACP Four line LCD annunciator with 20 For surface mounting. characters per line. Red. IntelliKnight 5700 FACP 5860TG Gray Trim Ring 5680 Remote Annunciator. For surface mounting. Four line LCD annunciator with 20 characters per line. Gray. SJL.. NT This document is not intended to be used for installation purposes. We try MADE IN AMERICA Ida ri to keep our product information up- to-date and accurate. We cannot cover T � all specific applications or anticipate all requirements. All specifications are FORM# 350224 Rev C, 05/06 - subject to change without notice. For more information, contact Silent k'y H intsn'obtl Knight 7550 Meridian Circle Suite 100, Maple Grove, MN 55369 -4927. © 2007 Honeywell International Inc. Phone: (800) 328 -0103, Fax: (763) 493 -6475. b INTELLIKNIGHT ACCESSORY • Model 5895XL Intelligent Power Module 1 r . ` ' ■ % \, The intelligent way to distribute power i throughout your installation. With 6.0 amps of output power, six programmable Flexput I/O circuits, <% -;:,, " ; „ and two Form C relay contacts, the Model 5895XL Intelligent Power Module allows you to greatly enhance the capabilities of an IntelliKnight system, distributing power where needed throughout a facility. 1 ' 5895XL modules connect via the RS-485 system bus. Up to eight 5895XL modules can be used per IntelliKnight system. Each 5895XL has its own optically isolated RS-485 bus to which other modules, such as 5860 remote annunciators and 5824 printer interface modules, can be connected. You can also connect 5815XL SLC expansion modules, adding flexibility and wiring distance. Each 5895XL supports its own backup batteries and monitors the AC power. Description • Up to 6,000 feet wiring distance 5895XL adds 6.0 amps of power, from 5895XL (same distance as i six Flexput I/O circuits, and two main FACP) Form C relay circuits to an • Battery charging capacity 35 Ah IntelliKnight installation. The • Large cabinet can house two 18 5895XL is optically isolated Ah batteries or RBB accessory providing ground loop isolation and cabinet can house battery sizes transient protection. The 5895XL larger than 18 Ah conditions the RS -485 system bus allowing up to an additional 6,000 • Room in FACP cabinet to mount feet of wiring. two 5815XL SLC expanders Operation • Built -in synchronization for '•9 The green LED on the 5895XL appliances from AMSECO ®, , • board indicates communication with Gentex®, Faraday, System the IntelliKnight FACP. Sensor®, and Wheelock® The Flexput circuits can be Electrical Specifications notification appliance circuits, continuous power, resettable Primary AC: power, door holder power or 120 VRMS @ 60 Hz, 2.5A initiation circuits that can support 240 VRMS @ 60 Hz, 1.4A both 2- and 4 -wire smoke Total Accessory Load: I `` detectors. All Flexput circuits and 6A @ 24 VDC " relay outputs are individually Current: mappable from the IntelliKnight Standby: 40 mA Model 5895XL 5820XL FACP. Alarm: 160 mA Features I/O Circuit Power: • 6.OA output power 3A per circuit (6A total per system) Approvals • • Flexput I/O circuits, 3A each, Mechanical Specifications NFPA 7 0, NFPA 7 2, NFPA 16, programmable as notification Flush or surface mount NFPA 0, NFPA 72 and circuits, auxiliary power circuits, Dimensions: NFPA 1 101 or initiation circuits 14 -1/2 "W x 24 -3/4 "H x 3 -7/8 "D • UL 864 • Supports Class A configuration (36.8 W x 62.9 H x 9.8 D cm) • CSFM for SBUS & Flexput circuits Overall Dimensions: 16 -1 /8 "W x 26 -3 /8 "H x 4 -1/8 "D • MEA 429 -92 -E, Vol. IX • Ground loop isolation (40.6 W x 67 H x 11.8 D cm) • approved a roved • 2 Form C programmable relays Color: Red rated at 2.5A at 24 VDC Environmental • Transient protection SILENT Operating Temperature: • SBUS repeater conditions the 32 °F — 120 °F (0° — 49 °C fti KNIGHT RS -485 signal Humidity: 10% — 93% non - condensing by Honeywell INTELLIKNIGHT ACCESSORY Model 5895XL Intelligent Power Module lilt, f Engineering Specifications The contractor shall supply a power module compatible with the IntelliKnight Model 5820XL FACP. The power module must have 6.0 amps of output power, Flexput I/O circuits rated 3.0 amps each, and two Form C relay contacts rated at 2.5 amps at 24 VDC. The power module shall connect to the main FACP via an RS-485 system bus (SBUS). The power module shall contain an additional RS-485 bus that is completely compatible with all IntelliKnight add -on modules, including 5815XL SLC expanders, 5860 remote annunciators, 5824 serial /parallel printer interface modules. The power module RS-485 bus shall be optically isolated providing ground loop isolation and transient protection. The unit shall be an SBUS repeater that conditions the signal driving up to 6,000 feet of additional wiring. 5820XL FACP 5895XL 5820XL 1 r — MAIN sews mroUT - -- — — — — FACP 123 22 21 20 19 18 17 16 33 32 31 30 23 22 21 20 19 18 17 161 + A B + A 8 + A B •+ A 8 + A 8 NACs, Auxilary [ r)C)C1 Oc,C > nC7 '' ,( SLC I Power, etc. I — _- — — i — -- I lam 5860 Used in - Used in To Next Class A Class A SBUS Device n I configurations Up to 6,000 Feet, Non - shielded Configurations Z -- 5895XL Connection to FACP D z m r Cl) - -- -- - - - - -- -•- — - - --- -- --.- Ell N 5895XL -1 I 5895XL -2 i NACs, Auxilary Power, etc. NACs, Auxilary Power, etc. I 5895XL -1 SBUS 5895XL -2 SBUS I I I I To Next 5895XL 5815XL 5860 5860 am 5815XL SLC SLC 5895XL Installation Example SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA N KNIGHT keep our product information up -to -date and accurate. We cannot cover all _ specific applications or anticipate all requirements. All specifications are FORM# 350212 Rev. C, 02 /06 ,, subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2006 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. 6 IntelliKnight is a Registered Trademark of Silent Knight Flexput is a Trademark of Silent Knight FIRE SYSTEM ACCESSORY . Model 5495 Distributed Power Module � 1 ; ! f ;: ' , < <;" " In an emergency, / (' ,' you need maximum power. • y �; , � � , ; The 5495 Distributed Power Module by Silent Knight is the most powerful and ,,, ; cost - effective power supply available today. It delivers 6 amps of notification appliance circuit power and built -in synchronization for appliances from System Sensor®,Gentex ®, AMSECO ®, Wheelock and Faraday — what you need to drive power -hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost - effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1- 800 - 446 -6444. Model 5495 • Independent trouble relay Distributed Power Module • AC loss delay option shuts off power The 5495 is a 6 amp notification power to non - essential high- current expander that provides its own AC accessories like magnetic door power connection, battery charging holders circuit, and backup battery for use with • • Built -in synchronization for l fire and security controls such as the appliances from System Silent Knight Model 5208 Fire Control Sensor®,Gentex®, AMSECO ®, /Communicator. The 5495 is the cost- Wheelock and Faraday � effective solution for powering 1 s • notification appliances required by the Stand alone operation Americans with Disabilities Act (ADA). • Lightweight design adds to ease of The 5495 has built -in ANSI cadence installation and reduces shipping ? pattern, which can upgrade older costs . control panels that lack cadence • Operates with most polarized, UL capability. Listed notification devices _ Features • UL 864 & 1481 listed • iK "' • UL Listed for 6 amps of notification • CSFM approved power • Power supply's advanced switch • ANSI Cadence pattern output Model 5495 capability built - in Distributed Power Module mode design reduces damaging heat and manages power up to 50% Connection to Local Fire Control more efficiently than other systems The 5495 may be connected to a local 4.7k52 end -of -line resistors provided. • Dip switches allow for easy fire control which utilizes Class A or Since the 5495 draws very little power reconfiguration Class B type notification circuits from the control, it is possible to • 24 VDC filtered output voltage operating between 9 and 32 VDC. The connect one 5495 to each notification control panel's notification circuit is circuit on the control panel and still • Four power - limited notification provide full supervision of the outputs; 2 Class A or 4 Class B, or 1 connected to one of the inputs on the out p p p 5495. The control panel's notification notification circuits all the way back to . Class A and 2 Class B the control panel. Additional continuous auxiliary circuit end -of -line resistor is also • Additional across two terminals on the . output 5495, which provides supervision SILENT • 3 amps per output circuit between the 5495 and the fire control • 2 inputs; 2 Class B or 2 Class A panel. Polarized audible and /or visual It KNIGHT • Ground fault detector /indicator notification devices are then connected m to the 5495 signal circuits using the by Honeywell FIRE SYSTEM ACCESSORY Model 5495 Distributed Power Module Supervision Current: Input . The 5495 supervises a variety of Standby 75 mA voltage range: 9 - 32 VDC • functions including: Alarm 175 mA Battery charging • Low AC power Auxiliary capacity: 33.0 AH • Low battery condition power circuit: 1 Ambient temp.: 32° to 120° F • Earth ground fault Notification 0° to 49° C • Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25" W x 16" H x • EOL supervision trouble or configuration: 2 Class A (Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A & 7.62 D cm) When a trouble condition occurs, 2 Class B the 5495 creates a trouble B) Indicator Lights condition on the host control signal Amps per AC power on : Green circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow ' - 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC addition, the 5495 provides a Form @ 3.0 amps each, Aux trouble: Yellow C trouble relay output as an 4.7 k52 EOL Output alternative to using the notification resistor required troubles (1 -4): Yellow circuit trouble. on each Class B Approvals: circuit UL: 864 & 1481 Electrical Specification - AC input: 120 VAC at 2 amps No. of inputs 2 NFPA: 72 Output: 24 VDC at 6 amps Input CSFM • configuration: 2 Class B or 2 Class A . Model 5495 Block Diagram • Signal Circuit Output Signal 1 Signal 1 input Distributed Signal 2 Signal Circuit Output Signal 2 Power • Input Module 5495 Signal 3 (Optional) Signal 4 120 VAC Aux. Power I Trouble Output Local Fire Control (Alternative to notification circuit trouble.) SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA IIG KNIGHT keep our product information up- to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350395 Rev B, 12/05 c subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2005 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. INTELLIKNIGHT ACCESSORY - ;SD500 -AIM & SD500 -MIM Addressable Input Modules r a IntelliKnight's addressable contact monitor modules combine fast response with pinpoint I location ID. A combination that saves lives and " . 3 property. !" The SD500 -AIM and SD500 -MIM are addressable input modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SD500 -AIM and SD500 -MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500 -AIM addressable input module mounts to a 4 "- square box. The SD500 -MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500 -AIM and SD500 -MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation —a flexible solution for all your fire protection needs. For more information about the IntelliKnight system, or to locate your nearest source, please call 1- 800 -446 -6444, or in Minnesota, call 763 -493 -6435. Description • DIP switch programmable for fast The SD500 -AIM and SD500 -MIM are installation _ _ addressable input modules for use with • Up to 2500 ft wiring distance from the Intelliknight fire alarm control either input module to contact panels (FACPs). The SD500 -AIM • • Use up to 14 gauge wire addressable input module mounts to a • UL listed 4 "- square box. The SD500 -MIM mini : " input module fits inside a single gan Electrical Specifications 0 ^ ^ L • box. Both input modules are designed Standby Current: 0.55 mA i to be used with pull stations, water flow Alarm Current: 23 mA max for one switches, and other applications device; 46 mA max for two devices; 60500-AIM requiring dry contact alarm initiation 0.55 mA for each additional device devices. / '`• These modules are supervised, single Line Resistance: 500 max ` -N - - . - ~' • input contact monitors. Using an EOL Mechanical Specifications \ resistor, they monitor for alarm contact SD500 -AIM Physical Description ctosures and for open circuit wiring �' Dimensions: fault conditions. If a fault occurs in the 4.9" W x 4.9" H x 1" D wiring, the module alerts the FACP. (12.4 W x 12.4 H x 2.5 D cm) SD5D0•MIIA Each addressable input module is Weight: 3.6 oz (120.1 g) programmed with a unique signal line Color: Ivory cover plate circuit (SLC) loop address. SD500 -MIM Physical Description Approvals Features Dimensions: • Single contact monitor 1.5" W x 2.5" H x 0.7" D NFPA 71 &NFPA 72 (3.8Wx6.4Hx1.8Dcm) UL 864 • D) or Class Bsupports y (Style B) Class contactStyle Weight: 1.6 oz (45.4 g) CSFM 7300-0559: 132 ( ) MEA 429 -92 -E Vol. IX monitor wiring Environmental FM Approved for use with the 5820XL • SD500 -MIM support for Class B Operating Temperature: (Style B) contact monitor wiring 32 °F – 120 °F (0 °C – 49 °C) • Attractive ivory cover plate with the SD500 -AIM Humidity: SILENT • Small and lightweight size allows for 10% – 93% non - condensing c ICNIGHT • flexible mounting options with the S D500 -M I M by Honeywell INTELLIKNIGHT ACCESSORY (SD500-AIM & SD500 -MIM Addressable Input Modules 41 : - Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500 -AIM or SD500 -MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SD500 -MIM shall fit inside a single gang electrical box. The SD500 -AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4 "- square or double gang electrical box. The SD500 -AIM addressable input module must provide a monitor LED that is visible from outside the cover plate la : G: � �:: i5 =l2:1 - - , ` � EQ .. - f 1 i N H141-.3 r. 51141`ti :r1 1 u :�,. i I tr , erg , r ,• -. I < f '' .. -'''' - f ") ( I ';.) i Compatible FACPs Ordering Information 5820XL SD500 -AIM Input Module 5808 Addressable input module with ivory 5700 cover plate. SD500 - MIM Input Module Addressable mini input module. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350231 Rev D, by Honeywell subject to change without notice. For more information, contact Silent Knight ©2008 Honeywell International Inc 1' 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Phone: (800) 328 -0103 or 763 -493 -6400 Fax: (763) 493 -6475. • www.sllentknight.com INTELLIKNIGHT ACCESSORY 1 Addressable s 1 Photoelectric Type , I , �- . Smoke Detector ,of ., (,,, Alikk Detect smoldering fires quickly and get 5 help fast with IntelliKnight photoelectric � r smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505 -APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505 -APS compensates automatically for contamination in the environment. And detector testing is simple —even from a remote site. Like other IntelliKnight detector models, the SD505 -APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors —easy installation, stable operation, RF /transient protection, and vandal- resistant locking —and it adds up to a flexible solution for all your fire protection needs. Model SD505 - APS The light received is converted into Analog / Addressable an electronic signal. Under normal - . ,--,\\ - Photoelectric Type conditions, the status LED blinks , , Smoke Detector approximately every 15 seconds, % / I 1 The SD505 -APS is particularly indicating that the head is .� ! N i suited to detecting dense smoke communicating with the loop. The typical of fires involving materials LED lights continuously during the such as soft furnishings, plastic, alarm period. foam or other similar materials Features which tend to smolder and produce • Low profile, 2 inches, including SD505 -APS Smoke Detector large visible particles. base Specifications The detector features automatic • Simple and reliable addressing Operating Voltage: 17 VDC compensation for contamination without mechanical switches Current Consumption: and a simple detector calibration • Automatic compensation for test procedure that can be run from sensor contamination Standby: .55 mA the panel or remotely (using the Alarm: .55 mA • Built-in fire test feature WindowsTM based downloading Simple detector calibration Ambient Temperature: 32 °F to 120 °F • software). testing through the control panel (0 °C to 49 °C) Operation or remotely through a Mounting: 4" Square, 4" The SD505 -APS units made up of WindowsTM based computer OCT, Single an LED light source and a silicon software. gang mud ring photo diode receiving element. In a • Vandal- resistance locking Relative Humidity: 85% normal standby condition, the features noncondensing receiving element receives no light • Field cleanable from the pulsing light source. In the Air Velocity: 0 - 300 FPM event or fire, smoke enters the UL listed, meets NFPA 72 Ch 7 requirements Com p atible Bases: SD505 - 6AB detector and light is reflected from (Sold Separately) (6" Base) • the smoke particles to the receiving CSFM approved SD505 -4AB element. • MEA approved (4" Base) . • FM Approved SILENT c- ' 5 KNIGHT 1. by Honeywell INTELLIKNIGHT ACCESSORY Model SD505 -APS Addressable Photoelectric Type o - Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505 -APS. The combination detector head, and twist -lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505 -AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal - resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505 -APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. l � Diameter= 5- 15/16" /l ------"'''N ,,,,,./ It Diameter = 3- 15116" 11 O // C-3 4 � • ` , c ( i '° Height inches, i including base L TC ) I% ‘,/., tam Model SD505 -6AB Detector Base Model SD505 -APS Detector Head (front view) (front view) SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350225 Rev C,. 05/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2005 Silent Knight . Phone: (800) 328 -0103, Fax: (763) 493 -6475. INTELLIKNIGHT ACCESSORY • v ( SD500- PS.and SD500 -PSDA ' . ' Addressable Pull- Station t I Mi.6 T IntelliKnight's addressable pull stations r.. IA - j jo combine fast response with pin -point r location ID. The SD500 -PS and SD500 -PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500 -PS /PSDA provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500 -PS /PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SD500 -PS & • Extremely easy to operate SD500 -PSDA • Corrosion - resistant gold - plated Addressable contacts. 4 PULL 4 ddressable Pull • Reflective label makes it easier N Station to locate in low light The SD500 -PS is a single action Operation 4 { ; ' . addressable fire pull station, and The SD500 -PS /PSDA single action the SD500 - -PSDA is a dual action pull stations are operated by a pull ' addressable fire pull station. The on the front pull cover of the SD500 -PS /PSDA feature rugged station. A plunger switch, wired to metal construction A terminal strip a self contained addressable on back of the pull station allows module, is released as the pull FIRE interconnection of the pull station to station opens to initiate the alarm. ` ' the SLC of an IntelliKnight control Once operated, the cover hangs panel. The SD500 -PS /PSDA is down and can be seen up to 100 /� designed for indoor use in non- feet away. The pull station is reset A ,ii T i i4 explosive environments. The by returning the front cover to the normally open initiating point normal upright position and contacts are gold - plated to avoid relocking the station with a reset risk of corrosion. The SD500- key. The reset keys are the same . N , .1 �t - PS /PSDA has been tested by UL keys used on Silent Knight J for compliance to the requirements enclosures. of the Americans with Disabilities The SD500 -PS /PSDA includes a ACT (ADA). status LED which blinks, indicating SD500-PS Features that the addressable module is Ambient Temperature: 32 °F to 120 °F • UL Listed communicating with the loop. The (0 °C to 49°C) • CSFM listed status LED lights continuously Mounting: Single gang during an alarm. A dip switch on box - • ADA compliant the addressable module is used to Optional Red Surface Mount Box PS - SMBB • Key reset (Same key as Silent set the unique address. Knight enclosures) Specifications • Surface mount back box Operating Voltage: 24VDC SILENT - available Standby Current: .55mA KNIGHT • Terminals - accept up to 14 Alarm Current: .55mA gauge wire " "h�YArtCTN.:MY INTELLIKNIGHT ACCESSORY SD500-PS and SD500 -PSDA - Addressable Pull- Station Engineering Specifications Manual pull station shall be addressable Module SD500- PS /SD500 -PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. R1, FACP fe -r i ♦` F F# i _ ,... _ __ __I____1.._ _ -i-° r: 9y I I ^ ♦ ♦ _,,t�.. .,, - - ...C19W. _ - d.n Ponti 7,„4. I�r I. l ♦ [ _. 11 i� 4:I' ', ■ , i �� ; �� ri , __+ —__ - I�t ,E. \ t (•- r _ \ 1 ` ``� i a ff � g � ' , _:_ ._ > ■ \ NO ! \ \ a Wiring r 2.92 i 1 I I 92 i C i i Mounting to Single Mounting to Optional Gang Electrical Box Surface Mount Box 5 , , t t A rnie L -- j ,,,,,m. SD500 -PSDA L lezer i .I Electrical Dos niutt be Installing SD500 -LK at r Dimensions `97`l- '17" Dee' 111% SILENT KNIGHT A w ,;yyr.J Cui4My 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800 - 446 -6444 or in Minnesota 763 - 493 -6435 FORM# 350342, Rev. 09/03 FAX: 763 - 493 -6475 , World Wide Web: http: / /www.silentknight.com Copyright © 2003 Silent Knight INTELLIKNIGHT ACCESSORY • Model SD500 -ARM Addressable Relay Module be. ' r. Place relay applications anywhere on the IntelliKnight loop with the SD500 -ARM Addressable Relay Module. The SD500 -ARM is an addressable device that adds great flexibility to the IntelliKnight system. Providing two Form C contacts rated at 2.0 amps @ 30 VDC or .6 amp @ 120 VAC. The SD500 -ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. Like other IntelliKnight SLC devices, the SD500 -ARM is compact for adaptability and pleasing aesthetics. Combine this with the features you've come to expect from Silent Knight fire protection devices —easy installation and stable operation —and it adds up to a flexible solution for all your fire protection needs. Model SD500 -ARM Features Addressable Relay Module . , r • Two sets of Form C contacts. 0 • The SD500 -ARM provides two Contacts are rated at 2A @ 30 _ 0 VDC or .6A @ 120 VAC. s " Form C contacts rated at 2A @ 30 VDC or .6A @ 120 VAC. • Up to 127 relays can be used on H' These contacts can be used for each SLC loop. virtually any normally open or • Relay programming is t I 11 normally closed application. completely flexible —can be Model SD500 -ARM mapped to zone conditions. • Polling LED visible through Specifications Operation cover plate. • UL listed, complies with NFPA Contact Rating: Form C Each relay module is 72. 2A @ 30 VDC programmed with a unique SLC • CSFM approved .6A @ 120 VAC loop address. When an event • MEA Approved, 429 -92 -E, Vol. 9 that controls the relay module • FM approved Standby Current: .55 mA occurs, the relay is triggered by Alarm Current: .55 mA the IntelliKnight panel. Ambient 32 °F to 120 °F Temperature (0 °C to 49 °C) SILENT Mounting 4- square electrical box KNIGHT a •INTELLIKNIGHTACCESSORY • Model SD500 -ARM . Addressable Relay Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable relay modules, Silent Knight SD500 -ARM. The modules shall be UL listed compatible with Silent Knight's Ihtelliknight FACPs. The relay module must provide two Form C dry contacts rated at 2.0 amps at 30 VDC or .6 amp at 120 VAC. The relay module must be suitable for mounting in a standard 4- square electrical box and must include a plastic cover plate. The relay module board must provide an LED that is visible from the outside of the cover plate. The relay must be fully programmable for such applications as are required by the installation. FRONT VIEW D I j CAUTION i REMOVE PC7 \4'ER PRIOR TO SERVICING I iwil �I o El I 1 71 • o O p [tel II (.,ate I I O O N ►i I14-10; 4 -7/8" 1/4" :; 1" Model 5D500 -ARM Addressable Relay Module Dimensions itN SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800-446 -6444 or in Minnesota 763 -493 -6435 FORM# 350218, Rev. 11/01 FAX: 763 - 493 -6475 World Wide Web: http: / /www.silentknight.com Copyright © 2001 Silent Knight INTELLIKNIGHT ACCESSORY • . Model SD500 -ANM r - .; Addressable Notification F Module �► i, t The cost effective way to expand the IntelliKnight's notification circuits. - The SD500 -ANM gives you the flexibility to add notification circuits L wherever I you need them. The SD500 -ANM is a supervised addressable notification device that provides you with additional notification circuits on the IntelliKnight SLC loop. Up to 127 SD500 -ANM modules can be used on an SLC loop. The SD500 -ANM provides a reverse polarity Class A or Class B notification appliance circuit with an aux power input. Each SD500 -ANM is provided power from a separate power supply and is controlled and supervised by the main panel. Power can be provided near the signaling appliance to reduce the wire gauge requirements or can come from a main power supply and be controlled separately by the individual notification modules. The SD500 -ANM can produce all 16 of the notification patterns available on the FACP. Model SD500 -ANM Features Addressable Notification Class A (Style Z) or Class B -1 1,......, Module ' ''.1..... • (Style Y) Notification Circuit. The SD500 -ANM is an Addressable • Flexible programming - choose ' , :, Notification Module for use with the the cadence pattern (twelve arc = -- t- ; t' IntelliKnight fire alarm control standard & four user - defined). - panel. The SD500 -ANM provides a ■ • single class A or B circuit that is Polling LED visible through cover _ _ controlled by the IntelliKnight's plate. Signaling Line Circuit. Power for • Adds up to 127 independent the circuit is provided to the output circuits on each SLC Model SD500 - ANM SD500 -ANM module from a loop. Approvals separate power supply, making it • Supervised auxiliary power easy to power remote devices. source input. • UL listed, complies with NFPA 72 The notification circuit, remote • CSFM • Completely supervised. power and communication to the • MEA 429 -92 -E, Vol. 9 SD500 -ANM are supervised by the IntelliKnight control panel. Specifications Operating Voltage: 24 VDC Compatible Control Panels Operation Each notification module is SLC Current: .55 mA • 5820XL programmed with a unique SLC Aux. Power Current: • 5808 Alarm: 56 mA loop address. When an event that 5700 Standby: 6 mA controls the notification module occurs, the notification switches its Notification built -in relay feeding power from Appliance Current: 2 Amp Max. the auxiliary power input to the Ambient Temperature: 32 °F to 120 °F notification appliance. (0°C to 49°C) Mounting: 4- square electrical box. 123. SILENT KNIGHT by He rt yrwa{1 INTELLIKNIGHT ACCESSORY Model SD500 -ANM Addressable Notification Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable notification modules, Silent Knight SD500 -ANM. The modules shall be UL listed compatible with a Silent Knight IntelliKnight fire alarm control panel. The notification module must provide one Class A (Style Z) or Class B (Style Y) notification output with one auxiliary power input. The notification module must be suitable for mounting in a standard 4- square electrical box and must include a plastic cover plate. The notification module must provide an LED that is visible from the outside of the cover plate. The notification output must be fully programmable for such applications as are required by the installation. FRONT VIEW • • l 11 i f • e � : • • ' tp • i~1 • M. ins � � +� 1L�FI • - - `i t. . M f g, jf4 . K ! Model SD500 -ANM Addressable Notification Module 13 SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up- to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350220 Rev.B, 2/07 subject to change without notice. For more information, contact Silent Knight Copyright © 2007 Silent Knight tY/ 14P-Irtyw't; 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Phone: (800) 328-0103, Fax: (763) 493 -6475. SYSTEM [.: SENSOR@ i - Selectable Output yip I [ Horns, Strobes, and Y, • -_ I Horn /Strobes SpectrAlert° Advance selectable- output horns, strobes, 1 and horn /strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTIWert a IN c Features The SpectrAlert Advance series of notification appliances is • Electrically compatible with existing SpectrAlert products designed to simplify installations, with features such as plug in • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 designs, instant feedback messages to ensure correct installation of candela individual devices, and 11 field - selectable candela settings for wall and ceiling strobes and horn/strobes. • Plug -in design • Field selectable candela settings on wall and ceiling units: 15, 15/75, When installing Advance products, first attach a universal mounting 30, 75, 95, 110, 115, 135, 150, 177,185 plate to a four -inch square, four -inch octagon or double -gang • Same mounting plate for wall- and ceiling -mount units junction box.The two -wire mounting plate attaches to a single -gang • Shorting spring on mounting plate for continuity check before junction box. installation Next, connect the notification appliance circuit wiring to the SEMS • Tamper resistant construction terminals on the mounting plate. • Outdoor wall and ceiling products rated from —40 °F to 151°F • Design allows minimal intrusion into the back box Finally, attach the horn, strobe or horn/strobe to the mounting plate • Horn rated at 88+ dbA at 16 volts by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the product's pins into the • Rotary switch for horn tone and three volume selections mounting plate's terminals. The device will temporarily hold in place • Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) with a catch until it is secured with a captured mounting screw. outdoor requirements • Outdoor products NEMA 4X rated The SpectrAlert Advance series includes outdoor notification • Compatible with MDL sync module appliances. Outdoor strobes and horn /strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or Agency Listings dry applications. u ° ® ■N,�F e T 7125.1653.186 (Indoor strobes) ■- �I'� 7300-1653 :186 (outdoor h!t,ob, . C0) 7125-1653 186 tr strobes) approved ,r. [ hlmVs.06 LISTED APPROVED 1y.i 7135 - 1653:1 es bes) s,chbnes) 54011 3023572 MEA452-05-E 55512 53593 SpectrAlert Advance Specifications Architect /EngineerSpecifications General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4 -inch octagon back box or double -gang back box.Two -wire products shall also mount to a single -gang 2 x 4 1 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 175 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. Strobes and horn /strobes shall have field - selectable candela settings including 15,15/75, 30, 75, 95,110,115,135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary- signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire voltage range. The strobe light shall consist of a xenon flash tube and associated lens /reflector system. Horn /Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary- signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three - pattern and a non - temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently'of the sounder.The horn on horn/strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor /weatherproof back box with half inch and three - fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 4 x 4 °/16 x 21 -inch back box.The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical /Electrical Specifications Standard Operating Temperature 32 °F to 120°F (0°C to 49°C) K Series Operating Temperature -40 °F to 151 °F ( -40°C to 66 °C) Humidity Range 10 to 93% non - condensing (indoor products) Strobe Flash Rate 1 flash per second • Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage Ranges 8 to 175V (12V nominal) or 16 to 33 V (24 nominal) • Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8 x 25" high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) 5.61. x 4.7W x 2.5T)(142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61x4.7Wx13"D(142mm L x 119 mm W x 33 mm D) Wall -mount back box skirt dimensions (BBS -2, BBSW -2) 5.91 x 5.0W x 220 (151 mm L x 128 mm W x 56 mm D) Ceiling -mount back box skirt dimensions (BBSC -2, BBSCW -2) 7.1 " diameter x 2.25" high (180 mm diameter x 57 mm high) Wall -mount weatherproof back box dimensions (SA -WBB) 5.71 x 5.1W x 2.00 (145 mm L x 130 mm W x 51 mm D) Ceiling -mount weatherproof back box dimensions (SA -WBBC) 7.1 "diameter x 2.0" high (180 mm diameter x 51 mm high) Wall -mount trim ring dimensions (TR -HS, TRW -HS) 5.71 x 4.812W x 0.350 (146 mm L x 122 W mm x 9 D mm) Ceiling -mount trim ring dimensions (TRC -HS, TRCW -HS) 6.9" diameter x 035 high (176 mm diameter x 9 mm high) Notes: • 1. Full Wave Rectified (FWR) voltage is a non - regulated, time varying power source that is used on some power supply and panel outputs. 2. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. • • A05-0395-005 . UL Current Draw Data UL •Max :'Strobe Current Draw (mA RMS) • UL Max. Horn Current Draw (mA'RMS) 8 -17.5 Volts 16 -33 Volts 8 -17.5 Volts 16 -33 Volts • Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR • Standard 15` 123 128 (66 (11) Temporal High 57 55 69 75 Candela Range 15/75' 142 148 77 81 Temporal Medium 44 49 58 69 30• NA NA 94 96 Temporal Low 38 44 44 48 75° NA NA 158 153 Non - temporal High 57 56 69 75 95• NA NA 181 176 Non - temporal Medium 42 50 60 69 110 NA NA 202 195 Non - temporal Low 41 44 50 50 . 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low ' 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -wire Horn/Strobe,-Standard Candela Range (15 -115 cd) 8 -17.5 Volts 16-33 Volts DC Input 15 15/75 (T5j 15/75 30 (75) 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 " 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non - temporal High 141 152 91 100 116 176 201 221 229 Non - temporal Medium 133 145 75 85 102 163 187 207 216 Non - temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non - temporal High 142 161 103 112 126 181 203 221 229 Non - temporal Medium 134 155 85 95 110 166 189 208 216 Non - temporal Low 132 154 80 90 105 161 184 202 211 •UL Max. Current Draw.(mA -RMS), 2 -wire Horn /Strobe,-High Candela Range (135 -185 cd) • • 16-33 Volts 16-33 Volts DC Input 135 150 177 (185; FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non - temporal High 255 270 303 309 Non - temporal High 233 248 275 281 Non - temporal Medium 242 259 293 299 Non - temporal Medium 219 232 262 267 Non - temporal Low 238 254 . 291 295 Non - temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed candela 'Horn and Horn /Strobe Output (dBA) . ratings must be reduced in accordance with this table. 24 Volt Nominal •StrobeOutput(cd) Switch Volts 8 -17.5 v160-33 Reverberant Anechoic Listed Candela Candela rating at -40°F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32 °F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non- temporal High 82 82 88 88 93 92 100 100 95 70 5 Non - temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non - temporal Low 75 75 81 81 88 84 96 92 115 115 • 7t Coded High 82 82 88 88 93 92 101 101 135 135 - 8t Coded Medium 78 78 85 85 90 90 97 98 150 150 9 Coded Low 75 75 81 81 88 85 96 92 177 177 tSettings 7, 8, and 9 are not available on 2-wire horn /strobe. 185 185 A05-0295065 SpectrAlert Advance Dimensions - 4.7" w-2.5" 6.9" $!I - - - 2 .5 l I IC�11 � ' Wall -mount horn /strobes Ceiling -mount horn /strobes A 7.1" 7.1. 1.225+1 • 2.0" Die. 5.05" 2.231 - Die. I I F / scic4 \ r 2. oD000 67, e o ` D- . . ill I a c 02 l 5.98' 6.2 .. � *\ j 1,,„,,, 7 Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box • SpectrAlert Advance Ordering Information Model Description • Model 'Description . Wall Horn /Strobes Ceiling Hom /Strobes (cont'd.) Wei 2-wire Horn/Strobe, Standard cd*, Red PC4W 4 -wire Horn/Strobe, Standard cd, White P2RH" 2-wire Horn/Strobe, High cd, Red PC4WH 4-wire Horn/Strobe, High cd, White (1 "° 2 -wire Horn/Strobe, Standard cd, Red, Outdoor Ceiling Strobes P2RHK° 2-wire Horn/Strobe, High cd, Red, Outdoor SCR" Strobe, Standard cd, Red P2W" 2-wire Horn/Strobe, Standard cd, White SCRH" Strobe, High cd, Red P2WH" 2-wire Horn/Strobe, High cd, White SCRK° Strobe, Standard cd, Red, Outdoor • P4R" 4 -wire Horn/Strobe, Standard cd, Red SCRHK° Strobe, High cd, Red, Outdoor P4RH" 4-wire Horn/Strobe, High cd, Red SCW' Strobe, Standard cd, White P4RK` 4-wire Horn/Strobe, Standard cd, Red, Outdoor SCWH "t Strobe, High cd, White P4RHK° 4 -wire Horn/Strobe, High cd, Red, Outdoor Horns P4W• 4-wire Horn/Strobe, Standard cd, White HR Horn, Red P4WH" 4 -wire Horn/Strobe, High cd, White HRK° Horn, Red, Outdoor Wall Strobes HW Horn, White (SR'* Strobe, Standard cd, Red Accessories SRH'r Strobe, High cd, Red BBS -2 Back Box Skirt, Wall, Red SRI(' . Strobe, Standard cd, Red, Outdoor BBSW -2 Back Box Skirt, Wall, White SRHK Strobe, High cd, Red, Outdoor BBSC -2 Back Box Skirt, Ceiling, Red • SW" Strobe, Standard cd, White BBSCW -2 Back Box Skirt, Ceiling, White SWH" Strobe, High cd, White 11:I-HS Trim Ring, Wall, Red Ceiling Horn /Strobes TRW -HS Trim Ring, Wall White PC2R" 2-wire Horn/Strobe, Standard cd, Red TRC -HS Trim Ring, Ceiling, Red �FC.2RH" 2 -wire Horn/Strobe, High cd, Red TRCW -HS Trim Ring, Ceiling, White PC2RK° 2 -wire Horn/Strobe, Standard cd, Red, Outdoor Notes: PC2RHK° 2-wire Horn/Strobe, High cd, Red, Outdoor " Add "-P" to model number for plain housing (no'FIRE' marking on cover), e.g., PC2W"t 2-wire Horn/Strobe, Standard cd, White P2R -P. PC2WH" 2-wire Horn/Strobe, High cd, White t Add" -SP'to model number for "FUEGO' marking on cover, e.g., P2R -SP. PC4R 4-wire Horn /Strobe, Standard cd, Red t "Standard cd" refers to strobes that include 15,15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 PC4RH 4 -wire Horn /Strobe, High cd, Red candela settings. PC4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor All outdoor units ending in K include a weatherproof back box. PC4RHK° • 4 -wire Horn/Strobe, High cd, Red, Outdoor a Add ' -R'to model number for weatherproof replacement device (no back box included). • ``� SYSTEM M 3825 Ohio Avenue • St. Charles, IL 60174 aoauRl C2008System Sensor, specifications s bjea to change without notkewlst systerr°ensorcorn for SENSOR Phone: 800- SENSOR2 • Fax: 630-377-6495 current product tnfamatlotilndurtng the Latest version delis date street 005 -0395 -005 • 8/C8. 12018 AS) 140 . V IS, ,. . Ok 1 ), � LISTED • Integration Fire Alarm Terminal Cabinet 16 Point Tool -Less The IF1 16 point "FIRE ALARM TERMINAL CABINET" is I designed to enhance your fire alarm systems. Ideally suited for maintenance and troubleshooting with easy identification of system wiring. . - - " tI Whit 7/8" highly visible lettering and a lift a way hinge d door i with captive fastener are ideal contributing features for rapid Qp NAI'v cabinet location and easy access. This surface mount cabinet is fabricated from 16 gauge steel with a durable red textured, baked -on powder coat finish. The IF1 is supplied with the SAE Tool -Less terminal blocks, saving you time and effort in your installation. Testing the cir- cuits can be accomplished with the use of the TTS Test Probe - in the individual test ports. Standard Features: • Dimensions: 6 1/2" W x 8 1/2" H x 2 1/2" D When properly installed, there • 16 gauge cold rolled steel construction will be no conductors exposed. • Wall mounting holes All circuit testing can be • Durable red textured finish performed via the individual test • White 7/8" indelible lettering ports per circuit. "FIRE ALARM TERMINAL CABINET" ,;i' ' • Lift -a -way hinge with captive fastener ;r • Interior labeling of terminal strip .r `'• • Field identification label inside cover �,� • Standard 1/2" & 3/4" EMT knockouts . ,/,.,r.'" 1 • Galvanized Mounting Plate , ° :.. • Four 4 Ckt. TTS Tool -Less terminal blocks .' • Terminal points rated for 12 gauge wire Z� • Terminal strip rated for 20 amp ' ! i max 250V (Class B /UL 300V (/CSA ) 1• � / � ! � t ISO 9001 Go REGISTERED N ox PA - NF Made I n U.S.A. COMPANY ADA Space Age Electronics, inc. www.1SAE.com � - Uses UL Recognized Components 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2007 ED0442 LT10481 Rev. B 1/2 No Excuses, Just Solutions! �' SPACEAGE ELECTRONICS, INC. Description: The TC1 18 Point Terminal Cabinet is constructed of 16 gauge (.062 thk.) cold rolled steel and fin- ished with a durable red textured, heat - resistant baked -on enamel finish. The front cover displays "FIRE ALARM TERMINAL CABINET" in 7/8" white screened indelible lettering, and is engineered with a removable formed lift -a -way hinge. A captive fastener secures the front cover. The interior of the box has a field identification label on the inside cover, corresponding to the terminal strip's labeling inside the back box. Overall dimensions measure 6 1/2" wide by 8 1/2" high by 2 1/2" deep. The cabinet includes standard 1/2" and 3/4" EMT knockouts on the top and bottom. A single 18 point high barrier terminal strip is rated for 12 gauge wire and 20 amp max 250V (Class B /UL) 300V (CSA). Removable formed lift-a -way hinge 4 . 6 112 c -s:1-• ,..i\*C. _. Z„,--3 / ua�� S FIR J � � RM , f • X12 A r! c- TER o 1 GAB INEY %,„ 1 ` Terminal Point - 2 Identification Label 1/4" mounting screw Back Plate clearance from back (° Detall plate to back box. I: drill screw I back (sett- tapping) , I : plate Ordering Information: Part # Description 1 i- 1/4" SSU00636 :IF1 16 Point Terminal Cabinet Agency Approvals: b box " UOXX.S2580 UL Listed Control Unit Accessories Optional Accessories: SAE 's Tooless Terminal Strip -B - 0 � PN Description pl. Included in IF1 Space Age Electronics, inc. SS000470 TTS Black C • I www.1SAE.com SS000471 TTS White ' -4► .. 800.486.1723 Toll Free Sold Separately 508.485.0966 Local SSU00472 TTS Test Probe 508.485.4740 Fax This document is subject to change without notice, see doc # ED0479 for legal disclaimer No Excuses, Just Solutions! ED0442 LT10481 Rev. B 2/2 . i k -, G ‘P , ", UI LISTED .__ - ___ _ :., ______ 1 ___ _ A Accessory Cabinet Enclosure C , i The ACE Accessory Cabinet provides an economical enclo- q` sure, ideally suited for field trouble shooting and easy main - @i�qRM tenance of system wiring. This surface mount cabinet is fabri- F T . _ cated from 16 gauge steel with a durable, red textured powder 1 coat finish. It features a formed lift-a -way hinged door for ease of access and maintenance and is key locked (CAT 30) for . security. The ACE cabinet includes an interior galvanized back plate . with hole matrix configuration for mounting optional compo- nents. The back plate is raised (1/2 "), for clearance of mount- ing hardware, as not to interfere with the back box. With the use of drill screws, which easily penetrate and securely hold components in place, the interior back plate's material allows Standard Features: custom configuration and installation of other equipment. . • Standard A and D surface mount, custom sizes available • 16 gauge steel construction • Durable red textured finish I I I • Lift-a -way hinge with a CAT 30 keyed door lock • 1/2 ", 3/4 ", 1 ", 1 1/2" and 2" EMT 111111 .. knockout clusters • black • 20 gauge galvanized back plate with blue More custom cabinet green mounting hole matrix colors available. • Internal threaded grounding lug screw in back box Custom Lettering Available: • Grounding stud screw on cover • Fire Alarm Cabinet • Removable, 1/2" raised back plate, • Access Control Cabinet mounted on 4 studs • Security Cabinet • Intercom Cabinet r i p zira p ir AA GO ISO 9001 ® Space Age Electronics, Inc. REGIS1ERED wwlsae.com • NFPEt Made I n U.S.A. COMPANY \ w. 800.486.1723 Toll Free • \ =' ADA 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2007 ED0205 LT10065 Rev.E 1/2 No Excuses, Just Solutions! SPACE AGE ELECTRONICS, INC. Specifications: - The ACE Accessory Cabinet Enclosure, A and D sizes, are constructed of 16 gauge (.062 thk.) cold rolled steel and finished with a durable red textured, heat - resistant baked -on enamel finish. The front cover features a removable formed lift -a -way hinge and a high security CAT 30 keyed door lock. Cus- tom finishes and labeling available. EMT knockout 1/2 ",3/4 ", 1 ", 1 1/2" and 2" clusters embedded in cabinet. The removable back plate is a 20 gauge galvanized plate mounted on studs to the back box. The back plate clears the back box by 1/2" to accommodate for mounting hardware on the back plate. Custom equipment mounting can be easily accomplished with the use of standard hole matrix or self tapping drill screws. Cover and back box include a threaded grounding stud and lug. Size Overall Dimensions of Cabinet 'A '23 1/2" wide x 13" high x 5 1/2" deep D 23 1/2" wide x 23 1/2" high x 5 1/2" deep Overall Cabinet Dimensions Size: A I Removable formed lift -a -way hinge 13" � f , 23 bc7ar 4�auUe ` I Size: D - alnized d te o , raised ille sh pla o 23 1/2 . Removable back plate enables mounting components and modules easily to meet your Back Plate custom configuration specifications. Detail Custom sizes available. drill screw back (sell plate Back Box =...1MM= Mounting Patter Size AD 20 1/4" W x 9 3/4" H 'ezr; .c., i D❑ 20 1/4" W x 20 1/2" H back box w 1/2" mounting screw clearance iii from back plate to back box H Ordering Information: back box Part # Description SSU00655 ACE A Accessory Cabinet Enclosure, Red SSU00657 ACE D Accessory Cabinet Enclosure, Red Space Age Electronics, Inc h Agency Approvals: - www.isae.com 800.486.1723 Toll Free UOXX.S2580 UL Listed Control Unit Accessories 508.485.0966 Local 508.485.4740 Fax This document is subject to change without notice, see doc # ED0479 for legal disclaimer No Excuses, Just Solutions! ED0205 LT10065 Rev.E 2/2 s k \k t , b 1 ,Nsxf .1 ,,ty t - , 1 , i M F R J 1 Multi -Fast Rail Module �` - The MFR fast rail is designed to be configured to hold 4 or 5 addressable modules (with a 4" square footprint). This rail O ,F� 4 Modules system, when installed in a proper enclosure eliminates the Address Modules need for multiple 4" square boxes or even modification of a 4" Not Includes o o trough. The MFR replaces all that work with an easy method of assembly for each addressable module. 5 Modules Each address module is installed with the terminal field con - Address Modules nections and address dials easily accessible after installation Not Includes for serviceability. The MFR is supplied with edge protectors to - eliminate wire shorts when pulling wire chases. i gauge au a 9 The MFR is manufactured from durable 24 galvanized / t , steel and is designed with multiple mounting hole patterns for wall or cabinet mount. Measurements are 18" long x 4 5/16" o� _ 1 .0J - wide with a depth of 2" with module installed. o o- The MFR is ideally suited for the Space Age ACE cabinet size A (SSU00655) or D (SSU00657) for a professional installation. Standard Features: Features key access and a lift away removable door to access • Dimensions: the address modules and field wiring thus allowing you time 18" long x 4 5/16" wide x 2" deep saving maintenance and trouble shooting of the system. 9" long x 4 5/16" wide x 2" deep • Secures 4 or 5 modules (18" long) 4" square pattern or only 2 (9" long) • 24 gauge steel construction • Durable galvanized finish Ordering Info: • Wire chase for vertical or horizontal SS000458 ( MFR 4/5 Module Rail • Edge protector to eliminate wire cuts Mounting hole pattern for wall or cabinet SS000462 MFR 2/3 Module Rail • mount IFl ■=ia■nl! !r MN . ISO 900 ' ® ,, , Space Age Electronics, Inc. REGISTERED j ti �,. www.lsae.com COMPANY 800.486.1723 Toll Free I M NFPA Made r"... . ADA 508.485.0966 Local 508.485.4740 Fax This document Is subject to change without notice, see doc # ED0479 for legal disclaimer ED0297 LT10297 Rev.A 1/1 No Excuses, Just Solutions! Terker4. Sealed Lead Acid Absorbed Glass Mat Technical Specifications W KA 12 -7.5 F Discharge Characteristics Duration of Discharge @ 77 °F 13.2 - 120V - . --H - - - ' l ; i L 1 f a . - 9. 11.N -- - -I 4 J . _l H- I ' Ij'.', ! I , - _ __�- ; 10.2. .,. c i 1 , , ii " ; , -- sA Itu ' 1 aii,, .29 N + 1 .1 -,. t• , I,: - -I'- - t 1 � I1 r 1 I i ,'! . -1 I T I i - i • I I ice z"•; i "V "I f 76A i i ■ I` ! 'I i i t Z 1 2 4 6 8 10 20 40 60 2 4 6 810 20 40 I min I hr i j rr . s i''•.s' ,,, x .,,.5 . ,,,. Discharge Time L Discharge Duration vs. Discharge Current Duration of Discharge @ Various Temperatures i{,! - _� ; 1! !ilk' I I C _ ' _ - :_1_f' -.t om. . _ _t WI -_ d ; , I �I\,\- - --104 °F - - i , f i i - U 5A .t 1 � T�Ni -!- i Iil• -t 3A ,, j i l , N y. - - 77 ^F � i Specifications t 1A - :. - ' i - -- - f ` _ All Specifications Are Rated at 77 °F Unless Otherwise Noted _ 8 aoornn S S F l) Nominal Voltage 12V 300rM 1 ' ■ I { l I 1 ; : i i ! ' , l _ 1 i.. t I i._ 1- i Ampere Hour Capacity (20hr Rate to 1.75VPC) 7.5Ah 1 i i I I II 1 i . 1T I ! !:1; ■ inches millimeters 3 s 10 20 40 60 2 4 6 10 15 203 I min 1 hr 1 Length 5.94" 151 mm Dimensions Width 2.56" 65mm Discharge Time Height 3.74" 95mm Height w/Term. 3.98" 101mm Weight 5.21bs Capacity Ratings Case Plastic ABS Resin 20 hour rate 7.5Ah Maximum Charge Current 0.3C or 2.25A Capacity 10 hour rate 7.0Ah Float Use Voltage 2.28V /Cell @ 77 °F 5 hour rate 6.4Ah Recommended Float Use Current <1.1A 1 hour rate 4.5Ah Charging Cycle Use Voltage 2.45V /Cell Cycle Use Current <2A 1 Month 97% Wattage Ratings Shelf Life 2 Months 91% Discharge Rate End Voltage 3 Months 83% 1.75V /Cell 1.67V /Cell Temperature Charge 32 °F to 104 °F 5 min. rate 54.1 55.9 Discharge 5 °F to 122 °F 10 min. rate 36.5 37.7 Range Storage 5 °F to 104 °F 15 min. rate 27.8 28.7 Capacity Affected 77 °F 100% 30 min. rate 16.9 17.4 by Temperature 32 °F 85% 45 min. rate 10.9 10.4 (20hr rate) 5 °F 64% 60 min. rate 9.8 10.2 The Information contained on this specification Is generally descriptive only and is not intended Ascent Battery Supply LLC to make or Imply any representation guarantee or warranty with respect to any cells and 925 Walnut Ridge Drive batteries. Cell and battery design/specification are subject to modification without notice. Hartland, WI 53029 1u - page 1 of 2 Werker. Sealed Lead Acid Absorbed Glass Mat Technical Specifications WKAl2 -7.5F Cycle Life vs. Depth of Discharge Physical Dimensions 120 % --- i -` I-- e 100% ...__ �` - - �` --- - - --- - A � f eo% — i . ... .0 \ I ' t c 0 a 100% 50% Depth 30% C.) Depth of 0epth o f D 40% _ O'crhar a .] Dhd xrge - ______t- -_ — _ i 1 20% I 0 200 400 600 800 1000 1200 1400 in mm Charge/Discharge Cycles ,n' A 5.90 151 ® B 256 65 C 3.70 95 A D 3.88 101 M!` Effect of Temperature on Float Life 10 L —C l Terminal \ 5 —___1 A \ -- in mm 3 0 A 0.185 4.70 B 0.250 6.35 co co B C 0.031 0.79 C a \ V \ \ 0.5 Open Circuit Voltage vs. Capacity Estimated Residual Capacity @ 77 °F 0.3 14.OV I 1t I I — �! 13.Ov — � - - - _ 0.1 I I 12.5V -- - - - - - - -- ____________r____ 50° 68° 86° 104° 122° 140° 158° R 12.0V _ _-------_-17 - -- - j - --- Temperature (F °) O 11.5v --� - --- + - - - c o ,osv -- - l_ — - I - -- I II \v va 10.0v �i � N . 0% 20% 40% 60% 80% 100% 1 - �] C 01 � Approximate Capacity ( %) 1l� e 11 1 Fe' MH 20720 The Information contained on this specification Is generally descriptive only and Is not intended Ascent Battery Supply LLC to make or Imply any representation guarantee or warranty with respect to any cells and 925 Walnut Ridge Drive • batteries. Cell and battery design/specification are subject to modification without notice. Hartland. WI 53029 w page 2 of 2 Tie r k e r. Sealed Lead Acid Absorbed Glass Mat Technical Specifications WKAl2 -12F2 . Discharge Characteristics Duration of Discharge @ 77 °F 13.2V I • ' II I i = I � 1 ! N; I � - i w 11.4V i i ' I t _ I o iv I i ;1 i I i I . I - -F o- ' ii 0.6A 9 .6V 1 i - -1 1 I -I I l 1 1- ." 1 -` + . e ^ I 1 - , 1 i ?1 i 9.9V - 1 - I ' -I .I ., , . 1 I. 12A . j . - i F. - _ , I . . 0. 7.9V j i.i I 1 - ?� 1• 1 2 4 6 0 to 20 40 W 2 4 0 8 1 20 40 e +�' I mitt I hr I i - Discharge Time • Discharge Duration vs. Discharge Current Duration of Discharge @ Various Temperatures 100A _ r-- :- _r_, =�� c — Lii it -----1- ' 1 -1 - '- d 30A f 1 1 ; i - 104 °F - I I I y l i r.1--- 5 �, .I Li i sr �_ i .. we ` ` -- L- - 77 °F Specifications l +va.niCauOfS C - - 32 °F - " - • f L 3A f ft! i �?'�'�- 1 All Specifications Are Rated at 77 °F Unless Otherwise Noted rn • ' _In! - Nominal Volta a 12V __._ 1t-'' L— .J_ • - Ampere Hour Capacity (20hr Rate to 1.75VPC) 12Ah o30 — inches millimeters 3 5 10 20 40 60 2 4 6 10 15 s030 • Length 5.94" 151mm I--- min I hr I Dimensions Width 3.90" 99mm Discharge Time Height 3.74" 95mm ' Height w /Term. 3.98" 101 mm Weight 9.26Ibs Capacity Ratings Case Plastic ABS Resin 20 hour rate 12.0Ah Maximum Charge Current 0.3C or 3.6A Capacity 10 hour rate 11.2Ah Float Use Voltage 2.28V /Cell @ 77 °F 5 hour rate 10.2Ah Recommended Float Use Current <2A 1 hour rate 7.2Ah Charging Cycle Use Voltage 2.45V /Cell Cycle Use Current <3.5A 1 Month 97% Wattage Ratings Shelf Life 2 Months 91% End Voltage 3 Months 83% Discharge Rate 1.75V/Cell 1.67V /Cell Temperature Charge 32 °F to 104 °F 5 min. rate 76.3 80.7 Range Discharge 5 °F to 122 °F 10 min. rate 52.5 55.3 Storage 5 °F to 104 °F 15 min. rate 40.5 43.0 Capacity Affected 77 °F 100% 30 min. rate 24.9 26.2 by Temperature 32 °F 85% 45 min. rate 20.4 21.9 (20hr rate) 5 °F 64% 60 min. rate 15.1 15.6 The information contained on this specification is generally descriptive only and is not intended Ascent Battery Supply LLC i to make or imply any representation guarantee or warranty with respect to any cells and 925 Walnut Ridge Drive batteries. Cell end battery design/specification are subject to modification without notice. Hartland, WI 53029 het • page 1 of 2 We r k e r. Sealed Lead Acid Absorbed Glass Mat Technical Specifications WKAl2 -12F2 Cyde Life vs. Depth of Discharge Physical Dimensions 120% • __ B 100% - -- � �1 I A 1 1+- : - - -.._ — 1.-- \ - -- 1-- --- 1 1 N1 1 t t I 1:: i z i. t .i t t Deh ___J 30% W -•- ( --. C .1 d Depth th of Depthd 40% Owe 0 b9e ' -I-- 7 - D 20% I I f I I 0 200 400 600 800 1000 1200 1400 ■ [Ill in Charge/Discharge Cycles A 5.94 151 B 3.86 99 C 3.70 94 D 3.98 100 Effect of Temperature on Float Life 10 I Terminal — I 5 - \\\\ — - \\ . A in mm 3 \, - 11 II A B 0.250 020 0 0.50 .35 E \ } C -�-' � — B C 0.310 8 a� R. 1 -I G1 1 \ \ \ • 0 0.5 I Open Circuit Voltage vs. Capacity Estimated Residual Capacity @ 77 °F I 0.3 14.0V - • 13.5V -- - - - -.. _______L___ I - -- - - a 13.0V - - - - - - i - -- 0.1 I > 12.5V -- -- —, - - -- -�- 50° 68° 86° 104° 122° 140° 158° ✓ 12.0V vf! r�...._1-1-_________,_ I - . - - - -- ----- Temperature (F °) a 11.5V - -r --- - a 11.oV - - - - - - -- ----- ---- – 1-- -- -I -- — O I a 10.5V - - — 10.0V I 446 0% 20% 40% 60% 80% 100% 111 Or Approximate Capacity ( %) I ' 4 1 AVIV, MH 20720 The information contained on this specification is generally descriptive only end is not intended Ascent Battery Supply LLC to make or imply any representation guarantee or warranty with respect to any cells and 925 Walnut Ridge Drive . batteries. Cell and battery design/specification are subject to modification without notice. Hartland. WI 53029 w page 2 of 2