Correspondence • /o7il lli; I �i� u� February 27, 2005 j s FILE Copy CITY OF TIGARD OREGON BA & S, LLC Tim Schlabach 15755 SW 88 Ave Tigard, OR 97224 RE: MY GYM — T I REVIEW Project Information Building Permit BUP2006-00073 Occupancy Type: B Tenant Name: My Gym Construction Type: 3B Address: 10115 SW Nimbus Occupant Load: 32 Area: 2,000 Sq Ft area Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and the Tualatin Valley Fire & Rescue 2003 edition. The submitted plans are approved subject to the following conditions. 1. Special inspection is required for bolts installed in concrete —epoxy & high strength bolting. The special inspection agency shall furnish inspection reports to the Engineer of Record, the General Contractor, and the City of Tigard, Building Division, attention Hap Watkins. All discrepancies shall be brought to the immediate attention of the general contractor for correction. The special inspector shall submit a final signed report stating whether the work requiring special inspection was, to the best of the inspector's knowledge, in conformance with the approved plans and specifications and the applicable workmanship provisions of the code. 1701.3 OSSC 2. The main exterior door or doors are permitted to be equipped with key - operated locking devices from the egress side provided: 1. The locking device is readily distinguishable as locked, 2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating. THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background. Sec. 1008.1.8.3 3. All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. 1008.1.8 OSSC 4. Doors to unisex toilet and bathing rooms shall be securable from within the room and be provided with a privacy lock and an "occupied" indicator. 1109.10.12.4 OSSC 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 5. Floor drains shall not be located within the clear floor space at a lavatory, water closet, urinal, or bathtub or shower. Floors shall not slope in excess of 1 unit vertical in 50 units horizontal (2- percent slope). Floor drains shall comply with Section 1109.4.5 and be without abrupt changes of level. Exception: Floor drains may be located within a clear floor space at a fixture provided the openings in the drain cover shall not exceed /2 inch (12.7 mm) in any direction and the drain cover shall be no more than 1 / 8 inch below the level of the surrounding finished floor surface. 1109.10.1 OSSC American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC, which may not include all of the requirements of the ADA. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 110.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Val Henze , Senior Plans Examiner