Loading...
Correspondence 4 l • t //9 Ih l l III �I 1 ''' II January 3, 2006 ( ` CITY OF TIGARD OREGON United Fire & Safety Jeff Hagerty 4611 NE MLK Blvd Portland, OR 97211 RE: FIRE SUPPRESSION SYSTEM @ CAFE PERSIA Project Information Building Permit: BUP2005 -00658 Construction Type: 5 -B Tenant Name: Cafe Persia Occupancy Type: B Address: 10115 SW Nimbus Ave #150 Occupant Load: NA The plan review was performed under the State of Oregon Structural Specialty Code (OSSC), Mechanical Specialty Code (OMSC) 2004 edition and 2004 Oregon Fire Code (OFC) amended by Tualatin Valley Fire & Rescue. The submitted plans are approved subject to the following. 1. The automatic fire suppression system shall be interconnected to the fuel or current supply for the cooking equipment and arranged to automatically shut off all equipment under the hood when the suppression system is activated. Shut off valves or switches shall be of a type that requires manual operation to reset. OMSC 509.4 2. Each automatic fire suppression system shall have both automatic and manual actuation means. A manual actuation device shall be located at or near a means of egress from the cooking area, a minimum of 10 feet and a maximum of 20 feet from the kitchen exhaust system. The manual actuation device shall be located a minimum of 4 feet 6 inches and a maximum of 5 feet above the floor. The manual actuation shall require a maximum force of 40 pounds and a maximum movement of 14 inches to actuate the fire suppression system. Exception: Automatic sprinkler systems shall not be required to be equipped with manual actuation means. OSSC 904.11 3. Automatic sprinkler systems protecting commercial -type cooking equipment shall be supplied from a separate, readily accessible, indicating -type control valve that is identified. OSSC [F]904.11.4 4. Sprinklers used for the protection of fryers shall be listed for that application and installed in accordance with their listing. OSSC [F]904.11.4.1 OFFICE COPY 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 I 5. An approved K -type portable fire extinguisher shall be installed within 30 feet of the cooking equipment, as measured along an unobstructed path of travel. OFC 904.11.5 6. Extinguishing systems shall be serviced at least every six months. OFC 904.11.6.4 7. The automatic fire suppression system shall be acceptance- tested in accordance with the OFC 904, and installation standard listed in section OMSC 509.3, and with the manufacturer's instructions. OMSC 509.5 8. The automatic fire suppression system shall be serviced at least every 6 months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion. OFC 904.6.4 Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respect , Val Henzel, Senior Plans Examiner