Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
A CITY OF TIGARD BUILDING PERMIT PERMIT #: BUP2006 -00375 .V1l1 DEVELOPMENT SERVICES DATE ISSUED: 9/20/2006 13125 SW Hall Blvd., Tigard, OR 97223 503 - 639 -4171 PARCEL: 1 S134AD -06202 SITE ADDRESS: 10500 SW NIMBUS AVE T ZONING: I -P SUBDIVISION: SCHOLLS BUSINESS CENTER LOT: JURISDICTION: TIG Project Description: TI (change of occupancy fr B &F /S to A3, 35,782 sq ft building) REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: ALT FIRST: 0 sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 3N : sf N: S: E: W: OCCUPANCY GRP: A3 TOTAL AREA: 0 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: 1,558 BASEMENT: sf AREA SEP. RATED: STOR: 1 HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: N MEZZ ?: N REQD SETBACKS REQUIRED FLOOR LOAD: 100 psf LEFT: ft RGHT: ft FIR SPKL: Y SMOK DET:Y DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : Y HNDICP ACC:Y BEDRMS: BATHS: IMP SURFACE: PRO CORR: N PARKING: VALUE: $ 644,076.00 Owner: Contractor: ROBINSON, CONSTANCE A + BNK CONSTRUCTION INC .. ROBINSON, LYNN + BELL, KAY ET 10730 SE HWY 212 BY INSIGNIA COMMERCIAL GROUP PO BOX 66 BEAVERTON, OR 97008 CLACKAMAS, OR 97015 Phone: Contact #: FAX 503 557 - 1085 PRI 503 - 557 -0866 FEES Reg #: LIC 107555 , Description Date Amount REQUIRED ITEMS AND REPORTS [BUPPLN] Pln Rv 8/4/2006 $1,842.59 [FLS] FLS Pln Rv 8/4/2006 $1,133.90 [METCET] Metro Const 9/20/2006 $772.89 [BUILD] Permit Fee 9/20/2006 $2,834.75 (additional fees not listed here) Total $6,810.91 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 503 - 246 -6699 or 1- 800 - 332 -2344. J Issued By: .f riP: Permittee Signature: / F. Call 503- 639 -4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. ■ Com /0,500 enant Impro cal * � it r . Buildine Permit Annlicati z OFFICI USE ONLl I•► a CI of Ti and E� cilrW0i ? ns ' Rece ived `J g Date/B . Afd (o ri i.. Permit No.: I 0 . _ — G O sip, q 13125 SW Hall Blvd., Tigard, OR 97231 i r p ■ Plan Revie B Phone: 503.639.4171 Fax: 503.598. 6 J D . ' j � Other Permit: FIG A r �� Inspection Line: 503.639.417 CITY OF Date Real � tt - ® S ee Page2 for Internet: www.tigard-or.gov �I(a,QRD N Notified/Metho: Su �r -or. pplemental Information g ov B UILDING DIVISIO TYPE OF WORK REQUIRI. DATA: 1- AND 2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees' at based on the value of the work performed. Indicate tl ✓ valu , rounded to the nearest dollar) of all ja Addition /alteration/replacement ❑ Other: equipmw , n labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. 12 1- and 2- family dwelling Commercial /industrial Valuation: $ El Accessory building ❑ Multi - family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: I C OO J N IM303 AVE / TBL.D6 5 T x New dwelling area: square feet City / State/ZIP: T Ei .4 2'D, O'TZ aiq 223 Garage /carport area: square feet Suite/bldg. /apt. no.: I Project name: 'SW 0 'QDC►C lupu,s#lp Covered porch area: square feet Cross street /directions to job site: Deck area: square feet SC O< (-S .T ecza..y Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: I Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: 1 Si ' -0620 2. -4P 22031ag4 4 22631 CMS eq irate uipmen the value (rounded to the nearest dollar) of all eqt, ma ter ial s , labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. T'- T>>4%J l i rn p2ntj JTS 9 O 2 Valuation: $ 6,14 oc40 VQctC - Z.LnUt) I p • Existing building area: 35,482 square feet New building area: 3 5 i 2. square feet PROPERTY OWNER I ❑ TENANT Number of stories: 1 Name: eP. a TO LA A�5pCIATaS LTD Type of construction: jil b Address: R-1I it ( '(off- -7- Occupancy groups: City / State/ZIP: I) S MOI Na 5O39 2 Existing: B • ■ Phone: (515) Z7 4 - -641,6 Fax: ( ) New: A-3 APPLICANT ❑ CONTACT PERSON NOTICE Business name: 14.Q .V – 'NI-NT 1--1AN746 'MENT ZLC. All contractors and subcontractors are required to be k y L LA-11-A- licensed with the Oregon Construction Contractors Board Contact name: under ORS 701 and may be required to be licensed in the . Address: 1024r, V4 NI 1 / So ITE L73 jurisdiction in which work is being performed. If the �3TZ Z 23 applicant is exempt from licenns g, the following reasons City / State/ZIP: --r 1 apply: 5 / Y .59 Phone: 3) 8 - ' 8 c 2 , 6 I Fax: : v (5 5C8 -9 E -mail: kiQ °� 1 "� n ves en7 , Corn f' J`S l j33 • b CONTRACTOR ! I • : f i Business name: •---� . \'H BUILDIN , -` , FEES* Address: (Please refer to fee schedule) Structural plan review fee (or deposit): City /State/ZIP: FLS plan review fee (if applicable): Phone:( ) Fax:( ) CCB lic.: may, Total fees due upon application: Authorized signs) °• °. � BIUK 60A/6 /Ruche/I Amount received: 0 Si ,. ,DR This permit application expires if a permit is not obtainetl I , p �/ �/ within days after it has been accepted as complete. Print name: , C) �J� / r ,. �'� -D8� * Fee methodology set by Tri -County Building Industry Service Board. I:\Building\Permits\BUP -TI- PermitApp.doc 03 3/06 440 -4613T(II /02 /COM/WEB) a 1111 . Building Division G Plan Submittal Requirement Matrix T I G A R D Commercial & Multi-Family - New, Additions or Alterations Type of Submittal # of Plans (Includes new, additions and alterations.) Required at Submittal Demolition Permit 2 (site plan required showing location and square footage of all buildings to be demolished) Site Work 2 (must include location of all accessible parking) Plumbing (site utilities) 2 Building 1* Fire Protection System 2 ** Mechanical 2 Plumbing (building fixtures) 2 Electrical 2 Plan review is dependent upon submittal of a completed application and plans. After plan review approval, the Plans Examiner will contact the applicant to request additional sets of plans for distribution purposes (for contractor, City of Tigard, Washington County, and Tualatin Valley Fire & Rescue) * For over - the - counter commercial tenant improvements, submit 2 sets of plans. ** "New" fire protection systems requite that plans bear the original seal of an Oregon licensed fire suppression engineer, or NICET level "3" technicians. I: \ Building \Permits \BUP -TI- PermitApp.doc 03/23/06 11Peo6.- 8ti 375 Form 4a Project Name: Solid Rock Fellowship Page: 1 SYSTEMS - GENERAL Applicability Plans /Specs Discussion of qualifying 400‘)C Show compliance by including a drawing sheet, detail exceptions on page 4-25 number, specification section and subparagraph. 1. Applicablity (SectionaU Is this form required? I\Ne Form Required. Complete forr �iPa prJ T o VAC system is being installed, or components of an existing HVAC system are being ?l.e., equipment, controls, ductwork, and insulation.) 0J \\ �� ❑ Exception. The building or part of the building qualifies for an exception from HVAC code requirements. Applicable code exception is Section 1317.1. Portions of the building that qualify: Area: Exception ❑ -1 ❑ -2 ❑ 3 Area: I Exception ❑ -1 ❑ -2 ❑ 3 Area: Exception 0-1 0-2 0-3 ❑ Form Not Required. This project does not contain work required to comply with code. 2. Simple or Complex Systems (Section 1317.9 or 1317.10) is Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and equipment efficiency worksheets as required. Form 4b is not required. ❑ Complex System. Project includes a Complex System. Complete this form (4a), form 4b and equipment efficiency worksheets as required. 3. Equipment Performance (Section 1317.5) ❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment, or heat - operated cooling equipment. o Complies. All new HVAC equipment have efficiencies not less than those required by code. The following equipment efficiency worksheets are attached: ❑ -4a ❑ -4b ❑ -4c 0-4d ❑ -4e ❑ -4f ❑ -4g ❑ -4h ❑ - ❑ - 4. Duct Insulation and Sealing (Sections 1317.7 & 1317.8) ❑ No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. v Complies. The plans and specifications call for all air - handling ducts and plenums to be insulated and sealed as required by Sections 1317.7 &1317.8. 5. Distribution Transformers (Section 1316.1) ❑ No Distribution Transformers. The plans /specs do not call for new distribution transformers. o Complies. All new distribution transformers comply with efficiency, testing, and labeling requirements of Section 1316.1.1. ❑ Exception. The project qualifies for an exception per Section 1316.1.1, Exceptiion: 0-1 0-2 03 0-4 ❑s 0-6 0-7 ❑-a ❑-s ❑ -10 0-1' 0-12 0-13 0-14 Attach relevant documentation for appropriate exception. The plans /specs show compliance in the following locations: 4. Spec. Section 16400 4-1 April 2005 Compliance with OSSC, effective 01/01/05 Form 4a Project Name: Solid Rock Fellowship Page: 2 SYSTEMS - GENERAL 6. HVAC Controls (Section 1317.4) 6.1 System Thermostat /Zone Controls (Section 1317.4.1) O Complies. All new HVAC systems include at least one temperature control device responding to temperatures within the zones. ❑ Exception. HVAC system qualifies for an exception from zone control requirements. The applicable code exception is Section 1317.4.2, Exception 0-10-2 Portions of the building that qualify: The plans/specs show compliance in the following locations: I Dwg. M4 8 M5 6.2 Off - hour Controls - Auto Setback or Shutdown (Section 1317.4.3) El Complies. Systems must have at least one of the following features: El Control Setback Complies. Each system is equipped with automatic control capable of reducing energy through control setback during periods of non -use or alternate use of spaces ❑ Equipment Shutdown Complies. Each system is equipped with controls capable of reducing energy use through automatic shutdown during periods of non -use or alternate use of spaces. HVAC systems with equipment shutdown are equipped with at least one of the following: D Programmable controls (1317.4.3.1 (1)) ❑ Occupant sensor (1317.4.3.1 (2)) ❑ Interlocked to a security system (1317.4.3.1 (3)) ❑ Manually activated timers with 2 -hour operation max (1317.4.3.1 (4)) D Exception. The building qualifies for an exception to the requirement for automatic setback or shutdown controls. The applicable code exception is Section 1317.4.3 Exception 0-10-2 The plans /specs show compliance in the following locations: 6.3 Control Capabilities (Sec. 1317.4.2.1) El Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. D Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section 1317.4.2.1 Exception 0-10-2 Portions of the building that qualify: The plans/specs show compliance in the following locations: 'Spec. Section 15900 6.4 Optimum Start Controls (Section 1317.4.3.2) o Complies. Separate HVAC systems have controls capable of varying start-up time of system to just meet temperature set point at time of occupancy. D Exception. HVAC systems have a design supply air capacity not exceeding 10,000 cfm. The plans/specs show compliance in the following locations: 'Spec. Section 15900 6.5 Heat Pump Controls (Section 1317.4.4) El No Heat Pump. The plans/specs do not call for a new heat pump ❑ Complies. All new heat pumps equipped with supplementary heaters are controlled to minimize the use of supplemental heat as defined in Section 1317.4.4. The plans/specs show compliance in the following locations: 4 -2 April 2005 Compliance with OSSC, effective 01/01/05 Form 4a Project Name: Solid Rock Fellowship Page: 3 SYSTEMS - GENERAL 7. Economizer Cooling (Section 1317.3) E51 No Cooling. The building plans do not call for a new fan system with mechanical cooling. ❑ Complies. Each new fan system has an air economizer capable of modulating outside -air and return-air dampers to provide up to 100 percent of the design supply air as outside air. ❑ Exception At least one new fan system qualifies for an exception. The applicable code exception is Section 1317.3, Exception 0-10-2 ❑s ❑A 0 -5 0 -6 If Exception 3 is selected complete the following: (a) Total cooling capacity of exempt units (Btu /hr) (b) Total installed building cooling capacity (Btu /hr) ❑ Complies. Sum of exempt units rated at less than 54,000 Btu/hr is <240,000 Btu /hr or a/b Unit Identifier of exempt units: The plans /specs show compliance in the following locations: 8. Economizer Pressure Relief & Integration (Section 1317.3.1 and 1317.3.2) El No Economizers Required. Project does not contain a new fan system requiring economizers. ❑ Overpressurization Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will relieve the extra air introduced by the economizer. ❑ Integration Complies. Economizer is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. ❑ Exception. The applicable exception is Section 1317.3.2, Exception ❑ - t 0 -2 The plans /specs show compliance in the following locations: 9. Hot Gas Bypass (Section 1317.5) o No Hot Gas Bypass ❑ Complies. See allowable amount of hot gas bypass as a percentage of total cooling capacity in table below. Unit ID Rated Cooling Capacity . Hot Gas Bypass Capacity Allowable. Hot Gas Bypass Rated Cooling Capacity Max Hot Gas Bypass <240,000 Btu /hr 50% >240,000 Btu /hr 25% ❑ Exception. Unitary packaged system with cooling capacity no greater than 90,000 Btu /h 4 -3 April 2005 Compliance with OSSC, effective 01/01 /05 Form 4a Project Name: Rock Fellowship Page:I 4 I SYSTEMS - GENERAL 10. Shutoff Dampers (1317.4.3.3) o Not Required. Shutoff dampers are not required on this project. ❑ Complies. Each outdoor air supply & exhaust system shall be equipped with motorized dampers. ❑ Exception. The building qualifies for an exception to the motorized damper requirement. The applicable code exception is Section 1317.4.3.3 Exception ❑ - ❑ -2 ❑ -3 ❑ -a ❑ -5 ❑ -6 The plans /specs show compliance in the following locations: 10.1. Shutoff Damper Controls (Section 1317.4.3.3.1) El Complies. Outdoor air supply and exhaust systems shall be provided dampers that automatically shut when systems or spaces served are not in use or during building warm -up, cooldown, or setback. ❑ Complies. Stair and shaft vents are capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. • The plans /specs show compliance in the following locations: Dwg. M4 & M5 10.2. Motorized Damper Leakage (1317.4.3.3.2) El Complies. Motorized outdoor air supply and exhaust air dampers have a maximum leakage rate of 4 cfm/ft2 at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. ❑ Exception. Packaged HVAC equipment may have maximum leakage rate of 20 cfm/ft at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. The plans /specs show compliance in the following locations: Spec. Section 15890 11. Piping Insulation (Section 1314) ❑ No New Piping. The building plans and specifications do not call for new piping serving a heating or cooling system or part of a circulating service water heating system. o Complies. All new piping serving a heating or cooling system or part of a circulating service water heating system complies with the requirements of the Code, Section 1314.1. ❑ Exception. New piping qualifies for exception: Section 1314.1, Exception 0 -1 0 -2 12. Occupancy Ventilation El Complies. Mechanical ventilation systems provide the required amount of ventilation is indicated in plans /specifications as specified in Chapter 4 of the Oregon Mechanical Specialty Code. ❑ Complies. Natural ventilation systems provide required amount of ventilation as certified by a reg- istered architect or engineer as specified by Section1203.4.1, Exception. Attach worksheet 4m. The plans /specs show compliance in Dwg & M5 the following locations: The plans /specs show compliance on the following pages: 4-4 April 2005 Compliance with OSSC, effective 01/01/05 Form 4a Project Name: Solid Rock Fellowship Page: 5 SYSTEMS - GENERAL 13. High Occupancy Ventilation (Section 1317.2.2) El Complies. HVAC systems with ventilation air capacities of 1,500 CFM or greater that serve areas having an average occupant load of 20 square feet per person or less from Table 1004.1.2 have a means to automatically reduce outside air intake. Identify applicable systems: Assembly Area Plans/specs indicate where equipment (i.e. carbon dioxide sensor) and sequence is specified: Dwg. M4 & M5 and Spec. Section 15900. ❑ Exception. HVAC systems are equipped with an energy recovery device with at least 50% recovery effectiveness. ❑ No High Occupancy Systems. Project does not contain an HVAC system as described above. 14. Exhaust Air Heat Recovery (Section 1318.3) ❑ Not Regulated. HVAC system does not have: 1) design supply air cap. of >10,000 cfm, and 2) min. outside air supply >70%, and 3) at least 1 exhaust fan rated at 75% of min outside air ❑ Complies. Heat recovery system increases outside air temperature by 20 °F (Climte Zone 1) or 30 °F (Zone 2) and has provision to provide bypass during air economizer mode. ❑ Exception. An HVAC system qualifies for an exception to this requirement. Applicable exception from Section 1318.3 Exd]ptid -3 0-4 0-5 0-6 0-7 The plans /specs show compliance in the following locations: 15. Large Volume Fan Systems (Section 1318.4.2.4) ❑ Not Regulated. The building plans or specifications do not call for fan systems over 15,000 CFM that serve a single zone and function for the purpose of temperature control. • Complies. Fan systems are equipped with variable frequency drive or two speed motor to reduce airflow as required by Section 1318.4.2.3. The plans /specs show compliance in the following Dwg. M4 locations: 16. Variable Speed Drives (Section 1317.10.3.1) El Not Regulated. The building plans or specifications do not call for fan and pump motors 10 horsepower and greater that serve variable -flow air or liquid systems. ❑ Complies. All fan and pump motors 10 hp and greater which serve variable -flow air or liquid systems are controlled by a variable -speed drive. ❑ Exception. The building qualifies for an exception to the variable -speed drive requirement. Portions of the building that qualify: Applicable code exception is Section 1317.10.3.1, Exception The plans /specs show compliance in the following locations: 17. Service Water Heating (Sec. 1315) ❑ No New Water Heating. The building plans and specifications do not call for new water heaters, hot water storage tanks or service hot water distribution systems. 9 Complies. All new water heaters, hot water storage tanks or service hot water distribution systems comply with the requirements of the Section 1315. ❑ Exception. The applicable code exception is Section: Exception: V9 - Portions of the building that qualify: The plans/specs show compliance in the following locations: I Dwg. P1 4 -5 April 2005 Compliance with ossc. effective 01/01/05 • Form 4a Project Name:'Solid Rock Fellowship Page: 6 SYSTEMS - GENERAL 18. Swimming Pools, Spas and Hot Tubs (Section 1315.5) E No New Pools. The building plans and specifications do not call for new, swimming pools, spas or hot tubs. ❑ On /Off Controls Complies. Spa and hot tub heaters are equipped with a readily accessible ON /OFF switch as required by Section 1315.5.1. ❑ Ventilation Controls Complies. Pool ventilation system is controlled based on humidity. ❑ Cover Complies. All heated pools, hot tubs and spas are equipped with a cover. ❑ Heat Recovery Complies. Pools, Spas, and hot tubs, over 200 ft utilize recovered heat as required by Section 1315.5.3. ❑ Exception. Heat recovery is not necessary as pool is heated by renewable energy or waste heat recovery sources capable of providing at least 70 percent of the heating energy required over an operating season. 19. Fume Hoods (Section 1317.2.1.) o No Fume Hoods. The building plans do not call for fume hood systems that have a total exhaust rate greater than 15,000 cfm. ❑ Complies. Fume hood systems have at least one of the following features: ❑ Variable air volume hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50% or less of design values. ❑ Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no warmer than 2° F below room set point, cooled no cooler than 3° F above room set point, no humidification added, and no simultaneous heating and cooling used for dehumidification control. ❑ Heat recovery systems to precondition makeup air from fume hood exhaust in accordance with 1318.3 - Exhaust Air Energy Recovery, without using any exception. The plans /specs show compliance in the following locations: 20. Parking Garage Ventilation (Section 1317.2.3) E No Enclosed Garages. The building plans and specifications do not call for enclosed Group S -2 parking garages with a ventilation exhaust rate greater than 30,000 CFM. ❑ Complies. The plans and specifications call for carbon monoxide sensing devices as required by Section 1317.2.3. ❑ Exception. Open parking garages. 21. Kitchen Hoods (Section 1317.11) El Not Regulated. The plans /specs do not call for any new kitchen hoods with exhaust capacity greater than 5,000 cfm each. ❑ Complies. All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm have at least 50 percent of the required makeup air, (a) unheated or heated to no more than 60 °F; and (b) uncooled or evaporatively cooled. The plans/specs show compliance in the following P P P � locations: 22. Outside Heating Systems (Section 1317.12) El No Outside Heating Systems. The plans /specs do not call for new permanently installed heating systems outside the building. ❑ Complies. All new permanently installed outside heating systems are radiant gas fired systems controlled by an occupancy sensor or timer switch as required by Section 1317.12. 4-6 April 2005 Compliance with OSSC, effective 01/01/05 CITY OPTIGARD BUILDING DIVISION PERMIT #: BUP200&00376 13125 SW Hall Blvd., Tigard, OR 97223 D ATE ISSUED: 9/20/206 Phone: (503) 639 -4171 a I C I Inspection Requests (24 Hrs.): (503) 639 -4175 ...34- "-_ INSPECTION WORKSHEET FOR DATE: 12/1/2006 TIME: 6:58AM PAGE: 51 SITE ADDRESS: 10500 SW NIMBUS AVE T CLASS OF WORK: SUBDIVISION: SCHOLLS BUSINESS CENTER LOT #: TYPE OF USE: PROJECT NAME: SOLID ROCK FELLOWSHIP DESCRIPTION: TI (change of occupancy fr B &F/S to A3, 35,782 sq ft building) OWNER: ROBINSON, CONSTANCE A +, PHONE #: CONTRACTOR: BNK CONSTRUCTION INC PHONE #: 503 - 557 Inspection Request Scheduled For: Date: 12/1/2006 Pour Time: Code # Inspection Description Confirm # Contact # Message 299 Final inspection 040517 -01 503- 888 -0235 Y Corrections /Comments /Instructions: B F= ZQ — 2_? f( -....---..., 0,.c..,/ ft 4gp PASS ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL • CALL FO' NSPECTION ❑ ADDITIO AL EES ASSESSED Inspector: ATEA Date: l Phone #: (503) 718- . ‘24-1 �J I CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2006- 003755 i 13125 SW Hall Blvd., Tigard, OR 97223 D ATE ISSUED: 9/20/2006 Phone: (503) 639 -4171 , Inspection Requests (24 Hrs.): (503) 639 -4175 `' I �- INSPECTION WORKSHEET FOR DATE: 11/15/2006 TIME: 7:07AM PAGE: 31 SITE ADDRESS: 10500 SW NIMBUS AVE T CLASS OF WORK: SUBDIVISION: SCHOLLS BUSINESS CENTER LOT #: TYPE OF USE: PROJECT NAME: SOLID ROCK FELLOWSHIP DESCRIPTION: TI (change of occupancy fr B &F /S to A3, 35,782 sq ft building) OWNER: ROBINSON, CONSTANCE A +, PHONE #: CONTRACTOR: BNK CONSTRUCTION INC PHONE #: 503 -557 -0866 Inspection Request Scheduled For: Date: 11/15/2006 Pour Time: Code # Inspection Description Confirm # Contact # Message 2 Final inspection 039792 -01 503-888 -0235 N Corrections /Comments /Instructions: V t . i til5: • C '' - Pl 7 0 7 ( ) ' ' i - 4 1 t) 1 & ' 7 4 . 1 I I I: ( . . / / . 4 q 4 b k - e . C- E5 0614Tili_ I f K4 Q6- —. 10EF___b etec_TRIc f 'dr Ft . Safiwtm ; 0• iw7 ❑ PAS ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS FAIL 111 CALL FOR INSPECTION ❑ ADDITI NAL FEES ASSESSED L 1 � 1 Inspector: �� Date: ` / ( t) i Phone #: (503) 718 -243 CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2000.0Q375 13125 SW Hall Blvd., Tigard, OR 97223 ;(J/ DATE ISSUED: 9/20/2006 Phone: (503) 639 -4171 4 11' Inspection Requests (24 Hrs.): (503) 639 -4175 '" _ I.. INSPECTION WORKSHEET FOR DATE: 11/13/2006 TIME: 7:04AM PAGE: 77 SITE ADDRESS: 10500 SW NIMBUS AVECT ' CLASS OF WORK: SUBDIVISION: SCHOLLS BUSINESS CENTER LOT #: TYPE OF USE: PROJECT NAME: SOLID ROCK FELLOWSHIP DESCRIPTION: of occupancy fr B&F /S to A3, 35,782 sq ft building) OWNER: ROBINSON, CONSTANCE A +, PHONE #: CONTRACTOR: BNK CONSTRUCTION INC PHONE #: 503-5.57-0866 Inspection Request Scheduled For: Date: 11/13/2006 Pour Time: Code # Inspection Description Confirm # Contact # Message 287 Suspended ceiling 0396/3-0/ 503-888-0235 N Corrections /Comments /Instructions: `� v. N 't :, %ACS � "s / l'4 i0. G 6 6 - ©a o C 4-tA.4a444 S g"\? --Loa - 01646q ( rc ( s e- - r e . 4 .; y v . ) I i 5 (rd ► LH 2ov - cz 4- C 014-04,6 l EL 26 - - 06 a'S G __ / 0 t 6 , 11 i • 7.6 0 (0 o6 Lif 1 0 C 3 '-i2,-A-t, A d) In 2d40 6 co - ) -- 74 (M !e,,I > ‘.(4. nova DO 3'03 / 2vr C .. i,!,& moo&- J WC) /p v I 1 / s o i j ( 'PASS ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS „U% FAIL ,; i CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED � A Z_, (/`� Inspector: l .� - - Date: l 1/4A 3/0 4. Phone #: (503) 718 - 2'`f' CITY, OF TIGARD BUILDING DIVISION PERMIT #: BUP2006-00375 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 9/20/2006 Phone: (503) 639 -4171 04 Inspection Requests (24 Hrs.): (503) 639 -4175 — ■ INSPECTION WORKSHEET FOR DATE: 10/11/2006 TIME: 7 :02AM PAGE: 11 • ' SITE ADDRESS: 10500 SW NIMBUS AVE T CLASS OF WORK: SUBDIVISION: SCHOLLS BUSINESS CENTER LOT #: TYPE OF USE: PROJECT NAME: SOUD ROCK FELLOWSHIP DESCRIPTION: TI (change of occupancy fr B&F /S to A3, 35,782 sq ft building) OWNER: ROBINSON, CONSTANCE A +, PHONE #: CONTRACTOR: BNK CONSTRUCTION INC PHONE #: 503-557 -0866 Inspection Request Scheduled For: Date: 10/11/2006 Pour Time: Code # Inspection Description Confirm # Contact # Message 275 Framing 038026 -01 503-888-0235 N Corrections /Comme is /Instructions: 4 I I •tt • / r .`..., S• '1 S S y D' ' ClNe 6 — 0 04(0 (5:1 - f ,, 1 s) v1 ?tea 4 - 00 `k64 C ew 5 4,(mss LIo -I-) TLC 20 a Cp - 06 is - "s (._ < _ ) odic I ICJ \ 0 k6 c C &A t OA10 4 11V -40 Ce_ - 00 ;? L I (T L) fi,M .d ' 0 0437 C i z ) DO o r . Uv k,‘ (,-,:_e_ • h bv cam- Awk S 0.2 eA _. ` c_- - .I-- AA, ' / i 4 GNaz c_,e_ . Li ) /A".1-1 0, leJt_61 °' vS . ❑ PAS PARTIAL APPROVAL ❑ CANCEL [1] NO ACCESS izo ❑ FAIL ) ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: ..\-- 2 CZ-- Date: Z5 Phone #: (503) 718- 2-"t Z a CITY OF TIGARD , BUILDING DIVISION PERMIT #: BUP200G.00375 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 9/20U2006 Phone: (503) 639 -4171 . I C I Inspection Requests (24 Hrs.): (503) 639 -4175 °`:_.. • INSPECTION WORKSHEET FOR DATE: 10/11/2006 TIME: 7 :02AM PAGE: 10 SITE ADDRESS: 10500 SW NIMBUS AVE T CLASS OF WORK: SUBDIVISION: SCHOLLS BUSINESS CENTER LOT #: TYPE OF USE: PROJECT NAME: SOLID ROCK FELLOWSHIP DESCRIPTION: TI (change of occupancy fr B &F /S to A3, 35,782 sq ft building) OWNER: ROBINSON, CONSTANCE A +, PHONE #: CONTRACTOR: BNK CONSTRUCTION INC PHONE #: 503 -557 -0866 Inspection Request Scheduled For: Date: 10/11/2006 Pour T. -. Code # Inspection Description Confirm # Contact # , -ssage ? . 280 Insulation 038029 -01 503-888-0235 Y 55__fe Corrections/Comments/Instructions: 0 6' ❑ PASS ❑ PARTIAL APPROVAL CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: Date: 6/‘ a Phone #: (503) 718- 2- 11-4 • CITY OF TIGARD . BUILDING DIVISION PERMIT #: BUP200 &00375 13125 SW Hall Blvd., Tigard, OR 97223 D ATE ISSUED: 9/20/2006 Phone: (503) 639 -4171 w � 1° Inspection Requests (24 Hrs.): (503) 639 -4175 W `'� �-. • INSPECTION WORKSHEET FOR DATE: 10/6/2006 TIME: 7 :03AM PAGE: 35 • - SITE ADDRESS: 10500 SW NIMBUS AVE T CLASS OF WORK: SUBDIVISION: SCROLLS BUSINESS CENTER LOT #: TYPE OF USE: PROJECT NAME: SOLID ROCK FELLOWSHIP DESCRIPTION: Ti (change of occupancy fr B&FIS to A3, 35,782 sq ft building) OWNER: ROBINSON, CONSTANCE A +, PHONE #: CONTRACTOR: BNK CONSTRUCTION INC PHONE #: 503 -567 -0866 Inspection Request Scheduled For: Date: 10/6/2006 Pour Time: Code # Inspection Description Confirm # Contact # Message a4 275 Framing 037794 -01 503- 888 -0235 Y Corrections/Comments/Instructions: - 7. 4 - l . i\v- c ,--Lfil...b. ) r ......._, ... eI' -r ib = ue-(-4 .........-- ot„,_____ . _ - I. , r� ice. —' — ❑ PASS PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL MI CALL F;R INSPECTION ❑ ADDIT ON ' L FEES ASSESSED i 1 Inspector: /el� Date: RIP 6 . - Phone #: (503) 718A-7,