Plans 13 4 e aoo (a - tc SSS I t qcci Fire & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series TY -B — 2.8, 5.6, and 8.0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage cable approval agencies, the testing is General not representative of all possible cor- - rosive atmospheres. Consequently, it �- r"' - ^- Description is recommended that the end user be =- �� ; consulted with respect to the suitability r- - , . � w The Series TY -B, 2.8, 5.6, and 8.0 of these coatings for any given corro- K- factor, Upright and Pendent Sprin- sive environment. The effects of ambi- 4 klers described in this data sheet are ent temperature, concentration of l standard response - standard cover- chemicals, and gas /chemical velocity, age, decorative 5 mm glass bulb type should be considered, as a minimum, rti. ,'' ti--1 spray sprinklers designed for use in along with the corrosive nature of the ' -- light, ordinary, or extra hazard, corm chemical to which the sprinklers will be �:, mercial occupancies such as banks, exposed. " Cdr hotels, shopping malls, factories, refin- An intermediate level version of the eries, chemical plants, etc. Series TY -B Pendent Sprinkler can be The recessed version of the Series obtained by utilizing the Series TY -B TY -B Pendent Sprinkler, where appli- Pendent Sprinkler in combination with cable, is intended for use in areas with the Model S2 Shield. a finished ceiling. It uses atwo -piece ,' Style 10 (1/2 inch NPT) or Style 40 (3/4 WARNINGS ' inch NPT) Recessed Escutcheon. The The Series TY - Sprinklers described 1.r Recessed Escutcheon provides 1/2 herein must be installed and main - inch (12,7 mm) of recessed adjust tained in compliance with this docu - { j ment or up to 3/4 inch (19,1 mm) of ment, as well as with the applicable IF' - s ! total adjustment from the flush pen standards of the National Fire Protec- . dent position. The adjustment pro tion Association, in addition to the vided by the Recessed Escutcheon re - standards of any other authorities hav- duces the accuracy to which the fixed ing jurisdiction. Failure to do so may pipe drops to the sprinklers must be impair the performance of these de- ' cut. vices. Corrosion resistant coatings, where The owner is responsible for maintain - applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. that which would otherwise be ob - The installing contractor or sprinkler tained when exposed to corrosive at- manufacturer should be contacted mospheres. Although corrosion resis- with any questions. tant coated sprinklers have passed the standard corrosion tests of the appli- Model /Sprinkler IMPORTANT Identification Always refer to Technical Data Sheet TFP700 for the "INSTALLER Numbers WARNING" that provides cautions with respect to handling and instal - TY1151 - Upright 2.8K, 1/2 "NPT lation of sprinkler systems and com- TY1251 - Pendent 2.8K, 1/2 "NPT ponents. Improper handling and in- TY3151 - Upright 5.6K, 1/2"NPT stallation can permanently damage TY3251 - Pendent 5.6K, 1/2 "NPT a sprinkler system or its compo- TY4151 - Upright 8.0K, 3/4 "NPT nests and cause the sprinkler to fail TY4251 - Pendent 8.0K, 3/4 "NPT to operate in a fire situation or cause TY4851 - Upright 8.0K, 1/2 "NPT it to operate prematurely. TY4951 - Pendent 8.0K, 1/2 "NPT Page 1 of 8 APRIL, 2006 TFP151 r Page 2 of 8 TFP151 • r ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING 1/2, ** NOMINAL SSU SURFACE NPT MAKE -IN DEFLECTOR 6 1— .. ....... •114...-...„ ! 5 _� 2 -1/4" —I 2-3/16" 4 (57,2 mm) I o AI gq (55,6 mm) . . i 2 1 -9/16" WRENCH -j if 3 . 2 (39,7 mm) FLATS 7S 6 1 1 II s DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. . FIGURE 1 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY1151) AND PENDENT (TY1251) SPRINKLERS 2.8 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) STYLE 10 PLATE SEATING ** NOMINAL RECESSED SURFACE NP T MAKE -IN ESCUTC DEFLECTOR �� 6* ', 1 7/16" 5 (55,6 mm) 2 -3116" —� (11,1 mm) A� IA i IMMIX _ � G l - trill MAKE -IN NOMNL 4 i F 1 -1/2' �r 2 -3/16" r :, -0 2 (38,1 mm) IP , I (55,6 mm) WRENCH =° 9 3 - �__, - - �__, - FLATS i SSP DEFLECTOR -"— 2 -7/8" (73,0 mm) DIA. -- ""1 1/2" NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. • Screw * * Pipe thread connections per ISO 7/ can be provided on special request. FIGURE 2 STANDARD RESPONSE SERIES TY -B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS 5.6 K- FACTOR, 1/2 INCH NPT • • M TFP151 Page 3 of 8 t ESCUTCHEON 1/2" (12,7 mm) STYLE 40 PLATE SEATING ** NOMINAL RECESSED SURFACE NP T MAKE -IN ESCUTCHEON DEFLECTOR 6 1/2 S 2 -5/16" II (12,7 mm) (58,7 mm) A� NOMINAL 4 MAKE -IN 1 -9/16" ' I Il � � . m �� 2 (39,7 mm) (577,2 2 mm) WRENCH i ��7 3 1 - —. -- -.. - - . FLAT S = ,� i4 1 SSP DEFLECTOR — 2-7/8" (73,0 mm) DIA. - - - I 3/4" NPT ** f PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on - special request. FIGURE 3 STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS ` 8.0 K- FACTOR, 3/4 INCH NPT ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING 1/2 ** NOMINAL SSU SURFACE NPT MAKE -IN DEFLECTOR *6 T ---- ,-_-_-__ d � , *!,'Tf ;> =.' 5 2-1/4" 2 -3/16" (57,2 mm) f .W 1 A (55.6 mm) 4 I 1 );• 1 -9/16" 11010 WRENCH °I r _ � 2 (39,7 mm) FLATS 1 s f 3 SSP 1 DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression - • orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 - STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K- FACTOR, 1/2 INCH NPT Page 4 of 8 TFP151 f SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE'"' LEAD WAX WAX OVER LIQUID BRASS PLATED POLYESTER COATED COATED LEAD COATED 135F157°C Orange PENDENT 155 °F /68 °C Red 2.8 (TY1251) 1, 2, 3 N/A 1/2" and 175 °F /79 °C Yellow NPT UPRIGHT 20OF/93°C Green (TY1151) 286 °F /141 °C Blue 360 °F /182 °C Mauve 1, 2 135 °F /57 °C Orange _ PENDENT 155 °F /68 °C Red (TY3251) 1, 2,3,4,5,6,7 1,2,3,5 1,2,3,5 1,2,3,5 and 175 °F /79 °C Yellow UPRIGHT 200 °F /93 °C Green 5.6 (TY3151) 286 °F /141 °C Blue 1" 2" 3 °° 5 °' r" 2" 3 °° 5" 1/2" NPT 360 °F /182 °C Mauve N/A 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 1, 2, 4, 5 N/A (TY3251)' 175 °F /79 °C Yellow Figure 4 200F/93°C Green 286 °F /141 °C Blue 1, 2 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY4251) 1, 2, 5 1, 2, 3, 5 1, 2, 5 and 175F/79°C Yellow 1, 2, 3, 4, 5, 6, 7 8.0 UPRIGHT 200 °F /93 °C Green 3/4" (TY4151) 286 °F /141 °C Blue 1**,2« 3" 5" r 1" 2" 5" NPT 360 °F /182 °C Mauve N/A 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 N/A (TY4251)' 175 °F /79 °C Yellow Figure 5 200 °F /93 °C Green 286 °F /141 °C Blue 1, 2 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red 8 FY4951) - 1/Y and 175 °F /79 °C Yellow 1, 2, 3, 5 N/A NPT UPRIGHT 200 °F /93 °C Green (TY4851) 286F/141°C Blue 360 °F /182 °C Mauve NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03). • 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31- 53- 428- 4444/Fax 31- 53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05). 8. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. • Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. °' 150 °F /66 °C Maximum Ceiling Temperature. TABLE A, LABORATORY LISTINGS AND APPROVALS a TFP151 Page 5 of 8 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD WAX WAX OVER BRASS PLATED POLYESTER COATED COATED LEAD COATED 2.8 PENDENT (TY1251) 1/2" and 175 PSI (12,1 BAR) N/A NPT UPRIGHT (TY1151) PENDENT (TY3251) 5.6 and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 1/2" UPRIGHT (TY3151) OR NPT RECESSED PENDENT 175 PSI (12,1 BAR) (TY3251) (SEE NOTE 1) N/A 8.0 PENDENT (TY4251) 3/4" and 175 PSI (12,1 BAR) NPT UPRIGHT (TY4151) RECESSED PENDENT (TY4251) 175 PSI (12,1 BAR) N/A 8.0 PENDENT (TY4951) • 1/2" and 175 PSI (12,1 BAR) NPT UPRIGHT (TY4851) NOTE: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C -UL); and, the Approval by the City of New York. TABLE B, MAXIMUM WORKING PRESSURE Technical Operation Data The glass Bulb contains a fluid which expands when exposed to heat. When Approvals the rated temperature is reached, the UL and C -UL Listed. fluid expands sufficiently to shatter the ); FM, LPCB, VdS, and NYC Approved. glass Bulb, allowing the sprinkler to (Refer to Table A for complete ap- activate and water to flow. proval information including corrosion resistant status.) Design Maximum Working Pressure Refer to Table B. Criteria Discharge Coefficient K = 2.8 GPM /psi (40,3 LPM /bart'2) The Series TY -B Pendent and Upright K = 5.6 GPM /psi (80,6 LPM /bart'2) Sprinklers are intended for fire protec- K = 8.0 GPM /psi (115,2 LPM /bar1I2) tion systems designed in accordance with the standard installation rules rec- Temperature Ratings ognized by the applicable Listing or Refer to Table A. Approval agency (e.g., UL Listing is Finishes based on the requirements of NFPA Sprinkler: Refer to Table A. 13, and FM Approval is based on the Recessed Escutcheon: White Coated, requirements of FM's Loss Prevention Chrome Plated, or Brass Plated. Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, E Physical Characteristics is to be used for recessed pendent Frame Bronze installations. Button Brass /Copper Sealing Assembly Beryllium Nickel w/Teflont rn Bulb Glass rr Compression Screw Bronze Deflector Copper 0 Bushing (K =2.8) Bronze 4- Page 6 of 8 TFP151 I 2 -7/8" DIA. C.--; C.--; - 5/811/4" (73,0 mm) 3/4" (19,1 mm) (15,916,4 mm) 1/4" (6,4 mm) WRENCH RECESS 2 - 1/4" DIA. (END "A' USED FOR FACE OF (57,2 mm) MOUNTING __ 1/2" NPT MODELS) SPRINKLER PLATE FITTING 1/8" WRENCH RECESS ' -' (3,2 mm) (END "B" USED FOR 1���I 3/4" NPT MODELS) r FIGURE 7 i /"' W -TYPE 6 SPRINKLER �, I WRENCH MOUNTING All SURFACE ' WRENCH CLOSURE SERIES 1 -1/4" (31,8 mm) RECESS TY B 3/4° (19,1 mm) FIGURE 5 • SERIES TY -B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT 0 ' 0 ' STYLE 10 RECESSED ESCUTCHEON 5.6 K- FACTOR, 1/2 INCH NPT .'� . PUSH WRENCH IN TO ENSURE 2 - 7/8" DIA. ENGAGEMENT WITH SPNKLER (73,0 mm) 3/4" (19,1 mm) 5/811 /4" WRENCHWGAREA (15,916,4 mm) 2 -1/4" DIA. - 1/4° (6,4 mm) FIGURE 8 (57,2 mm) MOUNTING W - TYPE 7 RECESSED SPRINKLER PLATE FACE OF SPRINKLER WRENCH FITTING 1/8" (3,2 mm) Installation J i l l ' ! r ' The Series TY -B Sprinklers must be " installed in accordance with the follow - �. ∎I ing instructions: • MOUNTING NOTES SURFACE Do not install any bulb type sprinkler if - -- - • the bulb is cracked or there is a loss of CLOSURE SERIES 1 - 5/16° (33,3 mm)! liquid from the bulb. With the sprinkler TY B 13/16" (20,6 mm) held horizontally, a small air bubble ( ) should be present. The diameter of the air bubble' is approximately 1/16 inch FIGURE 6 (1,6 mm) for the 135 °F /57 °C to 3/32 SERIES TY -B RECESSED PENDENT SPRINKLER ASSEMBLY inch (2,4 mm) for the 360 °F /182 °C temperature ratings. WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON A leak tight 1/2 inch NPT sprinkler joint 8.0 K- FACTOR, 3/4 INCH NPT should be obtained with a torque of 7 • to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with , 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. • (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40, 7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause TFP1S1 Page7of8 t( leakage or impairment of the sprinkler. heated rod, in order to prevent the by brushing it with a soft bristle brush. Do not attempt to make -up for insu�- installer from being burned. Care must be exercised to avoid dam - cient adjustment in the escutcheon age to the sprinklers - before, during, • plate by under or over - tightening the The Series TY -B Recessed Pendent and after installation. Sprinklers dam - sprinkler. Readjust the position of the Sprinklers must be installed in ac- aged by dropping, striking, wrench sprinkler fitting to suit. cordance with the following instruc- twist/slippage, or the like, must be re- The Series TY -B Pendent and Up- tions. placed. Also, replace any sprinkler right Sprinklers must be installed in Step A. After installing the Style 10 or that has a cracked bulb or that has lost accordance with the following instruc- 40 Mounting Plate, as applicable, over liquid from its bulb. (Ref. Installation tions. the sprinkler threads and with pipe Section). S t S Pendent sprinklers are to be thread sealant applied to the pipe Frequent visual inspections are rec- ep ep1. in the pendent position, e threads, hand tighten the sprinkler into ommended to be initially performed for upright to ll1. sprinklers te pendent are n be sition, installed abe in the sprinkler fitting. corrosion resistant coated sprinklers, the upright position. Step B. Tighten the sprinkler into the after the installation has been corn- pleted, to Step 2. With pipe thread sealant ap- sprinkler fitting using onl the only rosion resistant h coat ng.tThereafter, of the car- 7 Recessed Sprinkler Wrench (Ref . plied to the pipe threads, hand tighten Figure 8). With reference to Figure 3 annual inspections per NFPA 25 the sprinkler into the sprinkler fitting. or 4, the W -Type 7 Recessed Sprinkler should suffice; however, instead of in- Step 3. Tighten the sprinkler into the Wrench is to be applied to the sprinkler specting from the floor level, a random sprinkler fitting using only the W -Type wrench flats. sampling of close -up visual b- 6 Sprinkler Wrench (Ref. Figure 7), tions should be made, so as to better except that an 8 or 10 inch adjustable Step C. After the ceiling has been in- determine the exact sprinkler condi- Crescent wrench is to be used for wax stalled or the finish coat has been ap- tion and the long term integrity of the coated sprinklers. With reference to plied, slide on the Style 10 or 40 Clo- corrosion resistant coating, as it may Figures 1, 2, 3, and 4 the W -Type 7 sure over the Series TY -B Sprinkler be affected by the corrosive conditions Sprinkler Wrench or the adjustable and push the Closure over the Mount- present. Crescent wrench, as applicable is to ing Plate until its flange comes in con - be applied to the wrench flats. tact with the ceiling. The owner is responsible for the in- .. spection, testing, and maintenance of When installing wax coated sprinklers their fire protection system and de- with the adjustable Crescent wrench, C are a n d vices in compliance with this docu- additional care needs to be exercised ment, as well as with the applicable to prevent damage to the wax coating Maintenanc standards of the National Fire Protec- on the sprinkler wrench flats or frame The Series TY -B Sprinklers must be tion Association (e.g., NFPA 25), in arms and, consequently, exposure of p addition to the standards of any other bare metal to the corrosive environ- maintained and serviced in accord- authorities having jurisdiction. The in- ment. The jaws of the wrench should ance with the following instructions: stalling contractor or sprinkler manu- . be opened sufficiently wide to pass facturer should be contacted relative over the wrench flats without damag- N OTES to any questions. ing the wax coating. Before wrench Before closing a fire protection system tightening the sprinkler, the jaws of the main control valve for maintenance It is recommended that automatic I, wrench are to be adjusted to just con- work on the fire protection system that sprinkler systems be inspected, tact the sprinkler wrench flats. After it controls, permission to shut down the tested, and maintained by a qualified wrench tightening the sprinkler, loosen affected fire protection system must be Inspection Service in accordance with the wrench jaws before removing the obtained from the proper authorities local requirements and /or national wrench. and all personnel who may be affected codes. by this action must be notified. After installation, the sprinkler wrench flats and frame arms must be in - The owner must assure that the sprin- spected and the wax coating re- klers are not used for hanging of any touched (repaired) whenever the coat objects; otherwise, non - operation in ing has been damaged and bare metal the event of a fire or inadvertent opera - is exposed. The wax coating on the tion may result. wrench flats can be retouched by gen- Absence of an escutcheon, which is tly applying a heated 1/8 inch diameter used to cover a clearance hole, may steel rod to the areas of wax that have delay the time to sprinkler operation in been damaged, to smooth it back over a fire situation. areas where bare metal is exposed. Sprinklers that are found to be leaking NOTES or exhibiting visible signs of corrosion Only retouching of the wax coating ap- must be replaced. . plied to the wrench flats and frame Automatic sprinklers must never be arms is permitted, and the retouching painted, plated, coated or otherwise is to be performed only at the time of altered after leaving the factory. Modi- the initial sprinkler installation. fied sprinklers must be replaced. The steel rod should be heated only to Sprinklers that have been exposed to the point at which it can begin to melt corrosive products of combustion, but the wax, and appropriate precautions have not operated, should be replaced need to be taken, when handling the if they cannot be completely cleaned by wiping the sprinkler with a cloth or Page 8 of 8 TFP151 TY1251 P/N 57- XXX -X -XXX I I SPRINKLER TEMPERATURE MODEUSIN RATING 530 2.8K UPRIGHT (1 /2"NPT) TY1151 1 NATURAL BRASS 135 135 °F /57 °C 590 2.8K UPRIGHT (1 /2"NPT) 4 WHITE POLYESTER 155 155 °F /68 °C 570 5.6K UPRIGHT (1 /2"NPT) 3 WHITE (RAL9010) 175 175 °F /79 °C • 571 5.6K PENDENT (1 /2"NPT) 9 CHROME PLATED 200 200 °F /93 °C 590 8.0K UPRIGHT (3 /4 "NPT) 7 LEAD COATED 286 286 °F /141 °C 591 8.0K PENDENT (3 /4"NPT) 6 WAX COATED 360 360FI182°C 286 °F /141 °C MAX. - 560 8.0K UPRIGHT (1 /2"NPT) 8 WAX OVER LEAD 561 8.0K PENDENT (1 /2'NPT) • 286F/141°C MAX. TABLE C PART NUMBER SELECTION SERIES TY -B PENDENT AND UPRIGHT SPRINKLERS • any other legal theory, for incidental, Limited indirect, special or consequential dam- ordering ages, including but not limited to labor Warranty charges, regardless of whether TFBP Procedure was informed about the possibility of Products manufactured by Tyco Fire & such damages, and in no event shall When placing an order, indicate the Building Products (TFBP) are war- TFBP's liability exceed an amount full product name. Refer to the Price ranted solely to the original Buyer for equal to the sales price. List for complete listing of Part Num- ten (10) years against defects in mate- bers. rial and workmanship when paid for The foregoing warran is made in lieu and properly installed and maintained of any and all other warranties. ex- Contact your local distributor for avail - under normal use and service. This press or implied, including warranties ability. warranty will expire ten (10) years of merchantahility and fitness for a par- from date of shipment by TFBP N Sicular purpose. Sprinkler Assemblies with NPT P y Thread Connections: warranty is given for products or com- This limited warranty sets forth the ex- Specify: (Specify Model /SIN), Stand - ponents manufactured by companies clusive remedy for claims based on and Response, (specify K- factor), not affiliated by ownership with TFBP failure of or defect in products, materi- (specify temperature rating), Series or for products and components which als or components, whether the claim TY -B (specify Pendent or Upright) have been subject to misuse, improper is made in contract, tort, strict liability Sprink!er with (specify type of finish or installation, corrosion, or which have or any other legal theory. been installed, maintained, modi- y g ry' coating), P/N (specify from Table C). fied or repaired in accordance with ap- This warranty will apply to the full ex- plicable Standards of the National Fire tent permitted by law. The invalidity, in Recessed Escutcheon: (specify Protectin Association, and /or the whole or part, of any portion of this Specify: Style or 40 ) Re- warranty will not affect the remainder. cessed Escutcheon with (specify *) fin - standards of any other Authorities ish, P/N (specify). Having Jurisdiction. Materials found by TFBP to be defective shall be either • Refer to Technical Data Sheet TFP770. repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor Sprinkler Wrench: authorizes any person to assume for it, Specify: W -Type 6 Sprinkler Wrench, any other obligation in connection with P/N 56- 000 -6 -387. the sale of products or parts of prod- ucts. TFBP shall not be responsible for Specify: W -Type 7 Sprinkler Wrench, sprinkler system design errors or inac- P/N 56 -850 -4 -001. curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446