Loading...
Plans 1L/l50 .L`It/( uj°ae't 5 -07360J A U D I B L E / V I S I B L E N O T I F I C A T I O N ' SPECT FA!e rt Ceiling Mount Series SYSTEM �� SENSOR Strobes and Horn/ Strobes Models Available Strobe Models S 57s + White Red « - -^ r t SC2415W SC2415 a' ," SC241575W SC241575 er SC2430W SC2430 � ? • `� SC2475W SC2475 SC2495W SC2495 �� f .. ,a SC24115W SC24115 x7 ;'� q 3 " SC24177W SC24177 ,�2_ ,€ `� Horn/ Strobe Models White Red PC2415W PC2415 BBSCW PC241575W PC241575 RECEIVED PC2430W PC2430 PC2475W PC2475 PC2495W PC2495 NOV 10 ZOOS PC24115W PC24115 ). 3 " , ' PC24177W PC24177x3 CITY OF TIGARD Accessory Mounting Plates ' BUILDING DIVISION White Red BBSCW BBSC Product Overview Lower current draw System Sensor's SpectrAlert°° ceiling mount series strobes and horn/ strobes offer a fresh approach to addressing the unique needs for ceiling mount applications. Available in 15, 15/ 75, 30, 75, 95, 115, and 177 candela Technology. Like the original 93ectrAlert, the SoectrAlert ceiling mount series offer significant current draw reductions over other ceiling mount strobes and Horn/ strobe models include a three horn /strobes position switch for field- selecting horn tones. Installat qDectrAlert's compact design also offers installation savings. The - Electromechanical / 3KHz strobe and horn /strobe models mount to a 4 " "X4 "x1Y2" back box, and take up - Temporal/ Non tempura) little room in th back box, making connections easier. And with - High/ Low dBA output g a) ectrAlert's round shape, it is not necessary to align the back box with the room's walls. - Ceiling - specific shape, profile, and 4 always lines up. aesthetics Flexibility. SpectrAlert ceiling mount strobes and horn /strobes are available in Synchronizable with MDL Sync. Circuit" maven different candelas, including 177 candela for sleeping areas. The horn/ module strobe's tones are field- selectable through the use of a three position switch Mounts to 4" x 4"x 1Z" back box located on the bade of the unit. Selections include electromechanical and 3 KHz tones, temporal and non - temporal patterns, and high and Round shape offers greater placement low volume. flexibility Aesthetics. 9pectrAlert ceiling strobes and horn /strobes offer a design that is sensi- tive to the aesthetic demands of ceiling mount applications. The round shape main - p"``'Yi approved M dearly tains a low profile appearance, similar to that of a smoke detector and provides t ,.c!: I 3006 / ® dear/ visible" angles FIRE' identification from all an les _ S5512 566 61 -00.E S4011 7125- 1209:201 144 -00-0 7135 - 1209:204 Electrical Specifications Operating Voltage Operating Voltage Range U.S. Patent Numbers - 24 VDC and FWR unfiltered 16 -33 V 6,049,446 6,057,778 Input Terminals Operating Voltage Range w/ Sync. Circuit D424,465 • 12 to 18 AWG Module 17-33 V Notes: . 1. Full Wave Rectified (FWR) voltage is a non - regulated, time - varying power source that is used on some power supply and panel outputs. 2. The MDL causes a one -volt voltage drop in the notification appliance circuit. Table 1-A: SpectrAlert Strobe UL Max. Current Draw (mA RMS) Table 1 -B: Horn UL Max. Current Draw Measurements (mA RMS) Strobe 1633V FWR Operating 1633V DC Operating 1633V (DC) 1633V (FWR) Setting Current — Strobe Current — Strobe Temporal Low Electromechanical 23 23 (mA RMS) (mA RMS) Volume 15 68 64 3000 Hz Interrupted 33 23 High Electromechanical 53 44 15/ 75 77 78 Volume 3000 Hz Interrupted 57 40 30 107 113 Non- Low Electromechanical 37 29 75 197 205 Temporal Volume 3000 Hz Interrupted 32 33 95 239 274 High Electromechanical 49 49 1 15 298 325 Volume 3000 Hz Interrupted 56 58 177 399 489 Table 1 -C: 24V DC Horn/ Strobe UL Max. Current Draw Measurements (mA RMS) Temporal Non Temporal Low Volume High Volume Low Volume High Volume Candela Setting Electromechanical 3000 Hz Electromechanical 3000 Hz Electromechanical 3000 Hz Electromechanical 3000 Hz 15 73 73 76 78 75 75 81 86 15/75 89 89 91 92 89 90 96 98 30 126 125 128 128 125 125 131 134 75 225 222 222 222 219 219 221 222 95 272 270 271 271 266 265 269 270 - 115 297 297 296 296 291 290 292 293 177 512 504 501 496 491 493 491 496 Explanation of Published Voltage, Current, and SPL Specifications In May 2004 Underwriters Laboratories changed standard During May 2004, UL also changed the way they list the UL 1971 to require that operating current measuremments voltage range of a device. All 12V products will be listed are made using RMS (root mean square) instead of peak between 8 - 17.5V and all 24V products will be listed or average values. RMS measurements more accurately between 16 - 33V. Those devices are considered "regulat- predict the power consumption of a device since they take ed ". Any product that does not operate within these ranges into account the entire current draw profile including surge, will be listed as a "special application" with its operating repetitive surge, and peak values. The published RMS cur- voltage specified on the device. • rent is the maximum operating current of that device within its operating voltage range. This current maximum may or Notes may not occur at the endpoints of the voltage range. 1. Current draw for strobe-only products is shown in Table 1 Similarly, UL tests the audibility of devices in accordance 2. 24VDC 2 horn/ strobe current draw is shown in Table with UL 464 by measuring them across the operating volt- 1 -C ' age range to determine the minimum sound pressure level 3. Current draw for other horn/ strobe power supplies can be produced at any particular setting. . calculated by adding the strobe current in Table 1-A to the horn current in Table 1$ from the chosen settings. Horn Sound Measurements (dBA) SpectrAlert Dimensions Selectable Horn Tones 16-33V I-- 2.2"---I Temporal Low Volume Electromechanical 75 3000 Hz Interrupted 75 . (C -------- High Volume Electromechanical 80 t lii ■ 3000 Hz Interrupted 81 I� 613 0 Non - Low Volume Electromechanical 79 / (� Temporal 3000 Hz Interrupted 79 / High Volume Electromechanical 84 / , --- 3000 Hz Interrupted 86 SpectrAlert Ceiling Mount Strobe _ H-2.2=-1 ' s. 0 c•� t li ,.,,,....._ ______ SpectrAlert Ceiling Mount Horn/ Strobe - Ordering Information Model No. Description PC241575W Ceiling -mount horn/ strobe, 24 volt, 15/ 75 candela, SC2415 Ceiling -mount strobe, 24 volt, 15 candela, red white SC2415W Ceiling-mount strobe, 24 volt, 15 candela, white PC2430 Ceiling -mount horn/ strobe, 24 volt, 30 candela, red SC241575 Ceiling-mount strobe, 24 volt, 15/ 75 candela, red PC2430W Ceiling -mount horn/ strobe, 24 volt, 30 candela, white - PC2475 Ceiling -mount horn/ strobe, 24 volt, 75 candela, red SC241575W Ceiling -mount strobe, 24 volt, 15/ 75 candela, white SC2430 Ceiling-mount strobe, 24 volt, 30 candela, red PC2475W Ceiling -mount horn/ strobe, 24 volt, 75 candela, white - SC2430W Ceiling -mount strobe, 24 volt, 30 candela, white PC2495 Ceiling-mount horn/ strobe, 24 volt, 95 candela, red SC2475 Ceiling-mount strobe, 24 volt, 75 candela, red PC2495W Ceiling -mount horn/ strobe, 24 volt, 95 candela, white SC2475W Ceiling-mount strobe, 24 volt, 75 candela, white PC24115 Ceiling -mount horn/ strobe, 24 volt, 115 candela, red SC2495 Ceiling-mount strobe, 24 volt, 95 candela, red PC24115W Ceiling -mount horn/ strobe, 24 volt, 115 candela, white SC2495W Ceiling -mount strobe, 24 volt, 95 candela, white PC24177 Ceiling -mount horn/ strobe, 24 volt, 177 candela, red SC24115 Ceiling -mount strobe, 24 volt, 115 candela, red PC24177W Ceiling-mount horn/ strobe, 24 volt, 177 candela, SC24115W Ceiling -mount strobe, 24 volt, 115 candela, white white SC24177 Ceiling -mount strobe, 24 volt, 177 candela, red Accessories SC24177W Ceiling -mount strobe, 24 volt, 177 candela, white MDL Sync. Circuit Module, red PC2415 Ceiling -mount horn/ strobe, 24 volt, 15 candela, red MDLW Sync. Circuit TM' Module, white PC2415W Ceiling -mount horn/ strobe, 24 volt, 15 candela, white BBSC Surface -mount back box skirt, red PC241575 Ceiling -mount horn/ strobe, 24 volt, 15/ 75 candela, red BBSCW Surface -mount back box skirt, white • System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor — Far East System Sensor — India 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.8832.0119 Ph: 85.22.191.9003 Ph: 91.124.237.1770 x.2700 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.8832.5119 Fx: 85.22.736.6580 Fx: 91.124.237.3118 Ph: 800/ SENSOR2 System Sensor Europe System Sensor in Singapore System Sensor — Australia System Sensor — Russia Fx: 630/ 377$495 Ph: 44.1403.276500 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 www.systemsensor.com Fx: 44.1403.276501 Fx: 65.6273.2610 Fx: 613.54.281.172 Fx: 70.95.937.7983 © 2005 System Sensor. The company reserves the right to change product specifications without notice. A05- 1025 -008.91 #1530 SILENT 5395 Battery Calculation Worksheet KNIGHT (all currents stated in mA) - 4 4 11/08/2005 Instructions: fill in shaded data fields Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA 5395 Expanders) .. ` 75 225 75 225 5395 Totals 1 75 225 Auxilliary Devices (list all) 4 -wire duct detector _ I 0 0 4 -wire beam detector 2 10 28.4 20 56.8 door holder 0 0 EOL relay , 0 0 UV, detector, 0 0 4 -wire smoke detectors _ y 0 0 — Auxilliary Device Totals 2 20 56.8 Notification Appliances(list all) ADA strobes - 1 15cd 2 N/A 3' 1 N/A 650 — i$DAA strobes - 177cd 3 N/A 489 N/A 1467 Horns /Strobe 115cd 2 4 4,1 N/A 296 N/A _ 592 — Horns /Strob4� - 177cd 3 N/A 501 N/A 1503 Aux relays N/A N/A 0 annunciators N/A ,< N/A 0 • - Notification Appliance Totals 10 N/A 4212 Summary Section -- Standby Hrs. Required fr ' cK,'.2. - f, 17574 Alarm Sounding Minutes '�,�' Total System Standby mA 95 Total System Alarm mA 4493.8 4c 'v ^'r Total System Standby A/H 2.28 �/_ *1 - 466 -' Total System Alarm A/H 0.37 C k - pt L ° ; 83 4 Min. A/H Battery Required 2.65 Cp 4 3 ° /,70 ,9 Recommended A/H Battery 3.19 / / • l ,���„ 5 , mimic O N V E N T I O N A L D E T E C T I O N Model 6424 Projected Beam Th SYSTEM Smoke Detector �� SENSOR Models Available 6424 Projected Beam Smoke Detector. includes Transmitter and Receiver ' '° 6424A te Projected Beam Smoke Dector, ULC listed ' N It. ''''' v Product Overview 30' to 330' protection range System Sensor Model 6424 Projected B ea m Smoke Detector is uniquely suited Broad operating temperature range for protecting open areas with high ceilings where conventional spot type smoke (-22°F to 131 °F) detectors are difficult to install and maintain. Listed for operation at the broad est temperature range in the industry ( -22 °F to 131°F), the 6424 can be used in 4 wire 24 VDC operation garage or warehouse applications to provide early warning in environments Receiver and transmitter may be pow- where temperature extremes exceed the capability of spot-type smoke detectors - bred separately or together The 6424 consists of a transmitter and receiver with separate alarm and trouble One EOL power relay supervises bath sign which distinguish between a percentage of signal blockage and a total receiver and transmitter beam block. Four alignment LEDs on the front of each unit indicate signal Calibrated test filter included strength to ease alignment. The R emote Test St ation with alarm LED indicator, Model RTS451, i an accessory that mounts to a standard single gang box and Ceiling and wall mount brackets included c test and reset the Beam Detect from a remote location. Alignment LEDs — N° special tools required Built in automatic gain control compen- sates for signal deterioration from dust build -up Remote test station option • 3-year warranty -7.‘ 4 u� ®► MEA I . .. APPftOVEO a pproved Engineering Specifications Operational Specifications Electrical (Receiver) Specifications The projected beam type smoke detector Range Voltage shall be a 4 -wire 24 VDC device to be 30' to 330' (length) 20 to 32 VDC Maximum used with U.L. listed separately supplied 9.1m to 100.9m Maximum Ripple Voltage 4 -wire control panels only. Unit shall be Sensitivity 6.Ov (peak to peak) listed to U.L. 268 and shall consist of a 'separate transmitter and receiver capa- 30°% ±5% total obscuration, or Standby Current (24 VDC) ble of being powered separately y or 55% ±5% total obscuration _ 10mA maximum together. The detector shall operate in Fault Condition (Trouble) Alarm Current (24 VDC) either a short range (30 -100 ft.) or long 95% or more obscuration, 28.4mA maximum range (100 -330 ft.) mode. The tempera- Automatic gain control limit, ture range of the beam shall be –22 °F to Improper initial alignment Trouble Current (24 VDC) 131 °F. The detector shall feature a bank 27.1mA maximum of four alignment LEDs on both the Alignment Aid receiver and transmitter that are used to Integral signal strength indication Start -up Surge Current (24 VDC) ensure proper alignment of the unit with—(4 red LEDs) _ 19mA maximum out special tools. The beam detector Alarm Indicator Relay Contacts Current (24 VDC) shall feature automatic gain control Local red LED .5A at 30VAC /DC which will compensate for gradual signal deterioration from dirt accumulation on Trouble Indicator Reset Time lenses. The unit shall include both ceil- amber LED .6 seconds maximum ing and wall mounting brackets. Testing Normal Indicator Start -up Time (after 5 min. reset) shall be carried out using calibrated test Local flashing green LED 1 minute maximum filters or a magnet activated remote test Test /Reset Features Power Loss station. Obscuration filter Retain memory for 5 minutes minimum Local reset switch Remote test and reset switch capability (compatible with Electrical (Transmitter) Specifications RTS451 and RTS451KEY test station) Voltage 18.8 to 32 VDC Smoke Detector Spacing On smooth ceilings, 60 feet between Maximum Ripple Voltage: projected beams and not more 5.6v (peak to peak) than one -half that spacing between Current (24VDC) a projected beam and a sidewall. 10mA maximum Other spacing may be used depending on ceiling height, airflow characteris- tics, and response requirements. See Mechanical Specifications NFPA 72 Dimensions w /no bracket Relays 2.5 "H x 8.5 "W x 7 "D Alarm, trouble Dimensions w /ceiling mount bracket EOL relay is required to supervise power 5.5 "H x 8.5 "W x 7 "D Dimensions w /wall mount bracket Environmental Specifications 5.5 "H x 8.5 "W x 10 "D Temperature Weight –22 °F to 131 °F ( -30 °C to 55 °C) Receiver 1.5 lb (663 g) Humidity Transmitter 1.3 lb (598 g) 10 -93% RH noncondensing Mounting Separate ceiling and wall brackets • Wiring Plug with attached cable Beam Smoke Detector Wiring Diagram Transmitter and Receiver Powered Together CLASS A RETURN LOOP WHITE- WHITE- WHITE- l YELLOW WHITE -RED YELLOW RED STRIPE R I • .. () STRIPE STRIPE 4 O BTRIPE WHITE-BLACK WHITE -BLACK 1 I L INITIATING STRIPE ° ()RAY STRIPE () O RAY I LOOP Y Y -, EOL POWER WHITE WHITE VIOLET Y SUPERVISON WHITE RELAY MODULE • RED -WHITE WHITE - VIOLET RED -WHITE VIOLET EOL (SHOWN ENERGIZED) POWER + STRIPE 0 STRIPE STRIPE ° STRIPE RESISTOR TO DETECTORS BLACK BROWN BLACK BROWN 0 RECEIVER O 6 RECEIVER O ORANGE ()GREEN ORANGE °GREEN BLUE °GREEN BLUED °GREEN NOTE: FOR PROPER LISTED PALL SUPERVISION. AN EOL RELAY MUST BE USED. TRANSMITTER TRANSMITTER Transmitter and Receiver Powered Separately CLASS A RETURN LOOP WHITE - WHITE- WHITE- l YELLOW WHITE -RED YELLOW RED STRIPE - ° STRIPE STRIPE 4t °STRIPE I WHITE-BLACK WHITE -BLACK I I INITIATING STRIPE ° GRAY STRIPE () () GRAY ._ LOOP Y Y I - �- EOL POWER WHITE .T VIOLET WHITE VIOLET �T�� SUPERVISON O - O , WHIT - �•• RELAY MODULE RED -WHITE WHITE- VIOLET RED -WHITE VIOLET EOL (SHOWN ENERGIZED) POWER + STRIPE ° () STRIPE STRIPE STRIP RESISTOR TO _ DETECTORS BLACK BROWN BLACK BROWN () RECEIVER O O RECEIVER 0 ? ?GREEN GREEN ORANGE ? GREEN 1l T I T I T I TOR? FOR SMITTERALIGNMENT AID. - BLACK • • RED BLACK • • RED LISTED PANEL NOTE. FOR PROPER SUPERVISON, AN EOL RELAY MUST BE USED. • LISTED • GREEN WHITE GREEN REMOTE POWER SOURCE • • i • • POWER T RANSMITTER TRANSMITTER INPUTS TO TRANSMITTER ARE NONPOLAR 6424 Remote Outputs Remote Test Station Connection W HITE -BROWN STRIPE / WHITE -BROWN STRIPE ALARM SIGNAL POWER Ii) 0 • •" ' 0 ALARM I SIGNAL ORANGE SI AUX ( -) • -s /' O ITE - GREEN STRIPE S yr —•" TROUBLE SIGNAL 1 Y IIszr RESET BELLOW , POWER (--) 0 AUX (--) O GT .• BLUE .. TEST • I � 8424 REMOTE OUTPUTS 8424 RTS451 REMOTE TEST STATION Beam Smoke Detector Mounting Diagrams Wall Mounting HORIZONTAL ADJUSTMENT SCREW (810 -24 x 1 -318 In.) METAL WASHER • PLASTIC WASHER w MOUNTING HOLE ± , � ,� . 1 . v , WALL MOUNTING � MOUNTING HUB N----) BRACKET • ALIGNMENT / . 'U' BRACKET LEDs it •■ 11 ill V� � 0 00 11 VERTICAL 1 II I � ADJUSTMENT if li soap, SCREWS (2) Ihir O\ \ CABLE EGRESS ® O\ HOLE PLUG. USED A STATUS O I PLUG UNUSED HLLE. LEN (RECEIVER ONLY) I I I ALIGNMENT ADJUST I POTENTIOMETER BEAM LENS (RECEIVER ONLY) HOLE PLUG Ceiling Mounting HORIZONTAL ADJUSTMENT SCREW 010 -24 x 2- 1/41n.) METAL WASHER PLASTIC WASHER CEILING MOUNTING BRACKET ' ----- r C -vi MOUNTING HUB Il i O ` MOUNTING HOLES ALIGNMENT is.,--_,.,-,... 1 IT BRACKET LEN ',A t o 0 0o i Il VERTICAL / / II 1 I ► ADJUSTMENT f \ , �/�II \\ A90,,, SCREWS(2) O\ IP CABLE EGRESS • STATUS O ® C:> -- HOLE PLUG. USED TO LEN PLUG UNUSED HOLE. O (RECEIVER ONLY) I I I ALIGNMENT ADJUST I POTENTIOMETER • BEAM LENS (RECEIVER ONLY) HOLE PLUG Order;ng Information Part No. Description 6424 4 -Wire, 24 VDC projected beam smoke detector (transmitter, receiver, ceiling and wall mounting brackets) 6424A Same as above, Canadian model F37 -01 -00 Replacement test filter RTS451 Remote test station gTS451KEY Remote test station with key lock RA400Z Remote annunciator A77-716B End of line relay, 24 VDC B:AB Conduit kit for ULC model System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor — Far East System Sensor — India 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.524.6253 Ph: 85.22.191.9003 Ph: 91.124.6371770 sf. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.524.6259 Fx: 85.22.736.6580 Fx: 91.124.6373118 Ph: 800- SENSOR2 System Sensor Europe System Sensor in Singapore System Sensor — Australia Fx: 630/377-6495 Ph: 44.1403.276500 Ph: 65.6273.2230 Ph: 613.54.281.142 Documents on Demand Fx: 44.1403.276501 Fx: 65.6273.2610 Fx: 613.54.281.172 1 -800- 736 -7672 x3 • www.systemsensor.com 0 2002 System Sensor. The company reserves the right to change product specifications without notice. A05- 0217- 004•4/02(10K)•#930