Correspondence SEtu ozo 6,112.16 June12, 2006 Allen Danforth Masterpiece construction 13849 SW Mistletoe Dr Tigard, OR 97223 . • RE: New single family residence ( response to 6/9/06 submittal ) Project Information Building Permit: MST2006 -00086 Construction Type: VN Address: 9593 SW Mountainview Ln. Occupancy Type: R-3 Area: 3268 sq. ft. Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; the State of Oregon Oregon Residential Specialty Code ORSC) 2005 edition and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans have been reviewed and the following information is required prior to issuance of the permit. OVA-:' The insulation schedule shown on the plans do not meet the Oregon Residential Specialty code (ORSC) R values. (cam First and second floor plans showing shear walls are not readable. �i3. 11 : • ;:. -- _• o . 8 .• s .•lt g • ► - :. ': •_ • : oes not allow a bolt hole to be more than 1/16" 1 o impson car og)- 4 . - _: - - - - - • .1 •• - " .n - - ems. 5. Reactions on engineering and truss plans do not match. mob. Not able to read engineering on plans on S -1 and A-5. Needs to be larger print. 6t,.7. Need cut section thru family/ dining/ living rooms. Trusses in this area are not bearing on walls or beams as per truss detail ( trusses "A ", "Xl and X2 "). 0 8. - -- -. • • •:1 • •. lb; :- -: -- - - •••• •.• _ o { � } • - . • _ . ' : • .1 . ; - - : . . • • - . .otin for Beam FR 11 point load. Alu-se) "petk Fes.... - - rae . _.1` G a 1_ _ __ ,. s When submitting revised drawings or additional information, p ease attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Please respond to each condition on the list. secull -\ D Ne on • g,ej 00 7 Junes, 2006 Allen Danforth Masterpiece construction 13849 SW Mistletoe Dr Tigard, OR 97223 RE: New single family residence Project Information Building Permit: MST2006 -00086 Construction Type: VN Address: 9593 SW Mountainview Ln. Occupancy Type: R-3 Area: 3268 sq. ft. Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSQ 2004 edition; the State of Oregon Oregon Residential Specialty Code ORSC) 2005 edition and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99-01) 1999 edition. The submitted plans have been reviewed and the following information is required prior to issuance of the permit. 1. The insulation schedule shown on the plans do not meet the Oregon Residential Specialty code (ORSQ R values. 2. The loading criteria for the beam calculations appear to have the snow loading and dead loading reversed. 3. First and second floor plans showing shear walls are not readable. 4. Engineering pages are stamped with a Washington Stamp. 5. Shear wall 10 on page S -2 shows a HD -8A with a SSTB24 bolt instead of a 7/8 inch bolt as it was designed for and shear wall # 10 shows HD -8A with SSTB 24. 6. Note Con plans different than engineering Note Con S -1. 7. Reactions on engineering and truss plans do not match. 8. Note A different than lateral engineering notes. 9. Not able to read engineering on plans on S -1 and A-5. 10. Need cut, section thru family/ dining/ living rooms. Trusses in this area are not bearing on walls or beams as per truss detail ( trusses "A ", "Xl and X2 "). 11. Foundation not picking up Girder Truss AG point load. 12. Washington engineering stamp on plans. 13. Foundation plans not showing expanded footing for Beam FR-11 point load. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. s • ectfully �' an Nelson •