Loading...
Correspondence • November 15, 2005 Agr ' } ' CITY OF TIGARD OREGON CIDA, Inc Jennifer Beatie 4445 SW Barbur Blvd. #200 Portland, OR 97239 RE: T. I. WESTCON - REVIEW Project Information Building Permit: BUP2005 -00590 Construction Type: III-B Tenant Name: Westcon Occupancy Type: B /S -1 Address: 14058 SW Milton Court Occupant Load: 73 Area: 12,447 sq ft Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and 2004 International Fire Code as amended by TVF &R. The submitted plans are approved subject to the following conditions. 1. Required exits shall be located in a manner that makes their availability obvious. Exits shall be unobstructed at all times. 1014.2 OSSC 2.' Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. 1011.1 OSSC 3. All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. 1008.1.8 OSSC 4. Exit signs shall be illuminated at all times and shall be provided with a second source of power that will provide 1 V2 hours of illumination in case of primary power loss. 1006.3 OSSC. FYI Additional exit signs may be required by the city field inspector to clearly indicate the path of egress. 5. Deferred submittals such as Fire Alarm, Fire Sprinkler, Truss Joist Shop Drawings, etc, will be charged a deferred submittal fee based on the valuation of the portion of the work being deferred. The minimum fee shall be $200.00. Deferred Items: None Noted NOT PART OF THIS REVIEW: * Electrical * Mechanical * Plumbing 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 6. Safety glazing including but not limited to the following locations: Each unit of glazing shall be permanently identified by the manufacturer. 2406 OSSC. Some of these locations are as follows: a. Glazing in ingress and means of egress doors. b. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical edge is within a 24" arc of the door in a closed position and whose bottom edge is less than 60" above the floor or walking surface except when there is an intervening wall or other permanent barrier between the door and the glazing. 7. American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC, which may not include all of the requirements of the ADA. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 110.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Resp y al Henze , Senior Plans Examiner 11/14/2005 15:26 5032261670 CIDA PAGE 03/04 I ' 1 .... f '� \ r ' L_1 A- ,/ L ,; A eld �, tl II r n . 11 r • Cr) rig , , j �� ' � �"� I �I J OFFICE AREA c � �' i 17 1 41' I 1 dr---7: J 1 NORTH 0 FLOOR PLAN NOT TO SCALE OCCUPANCY LOADS ROOM OCCUPANCY AREA LOAD OCCUP. EXITS EXITS NAME FACTOR LOAD REQ'D PROVIDED **OFFICE B 5945 100 60 2 2 *WAREHOUSE S 6463 500 13 1 2 *MAX. TRAVEL DISTANCE TO ANY EXIT IS LESS THAN 200' PER IBC TABLE 1015.1 ** EXITS MAINTAIN 1/2 THE TOTAL OFFICE DIAGONAL PER CHAPTER 10 IBC ' DrMAWINO TITLE FLOOR PLAN - TRAVEL DISTANCES DRAWING: PROJECT: MOM LT. MEM N COURT 14058 SW ULTO TIGARD. °mom SK doe �.�0050,� 0900.01 0,6,E 11/14/05 -Mes' .446 $W BuRBUR wOUL RD suRE 200 ►ONTL440, OIIEOON *7222 'TL• (Sea) 222 -1'22 RAX: (207) 222 -1870 ® 2005 Cek P.GJOO. pc. A11. 6101113 MEMO 11/14/2005 15:26 5032261670 CIDA PAGE 02/04 • • 4445 SW 6ARBUR BLVD., SUITE 200 PORTLAND, OREGON 97239 TEL: 503.226.1285 FAX: 503,226.1670 E -MAIL: infoecidalnc,com RECEIVED www.cidainc.com A C November 14, 2005 CITY 01= TIGARD BUILDING DIVISION City of Tigard Attn: Val Henze! 13125 SW Hall Blvd. Tigard, Oregon 97223 RE: Westcon T.I. Remodel CIDA Project Number. 050090.01 Permit #: BUP2005 -00590 Dear Val: The following is our response to your attached plan check conditions of approval dated November 7, 2005: Building Review 1 Per Coversheet CSI the "Existing Building Code Information" lists construction type as III -N, B2 occupancy. Per IBC the existing building falls under type III -B with B and S-1 non separated use. • Per IBC table 503 with 5 - I as our most restrictive use we are allowed 17,500 sq,ft. of building. Our current building area is 12,474 sq.ft. If necessary we can provide a revised CSI sheet 2 See SKI for occupancy calculations and required exits for warehouse. SK I indicates max. re•uired travel distances • er Table 1 015.1 . Max. distance is less than 200 ft. 3 See SKI for occupancy calculations and required exits for office space. Per calculations we are required to have 2 exits. SKI indicates min, required exit separation and max. travel distance to _ an exit Max. distance is less than 200 ft per Table 1015.1 4 Per OFC Chapter 23 racking commodities for Westcon are Class I — Appliances, non- combustible, electrical. Per sheet A! . I no racks shall be above 12' -0" unless approved by the C' of Ti ard. If you have any questions please do not hesitate to call. Sincerely Elizabeth Kale Interior Designer Enclosure c Jennifer Scathe File /RCHITFCTI.JRF • rNGINrr- .RINC, • PLAN C, • INI RioRS • LAN DSC_APL • • TRANSMISSION VERIFICATION REPORT TIME : 11/07/2005 10:49 NAME : TIGARD BUILDING DEPT FAX : 5036243681 TEL . SER.# : BROD4J479592 DATE,TIME 11/07 10:49 FAX NO. /NAME 5032261670 DURATION 00:00:16 PAGE(S) 01 RESULT OK MODE STANDARD ECM November 7, 2005 A0 m, , ,! 1f,. CITY OF TIGARD OREGON CIDA, Inc Jennifer. Beatie 4445 SW Barbur. Blvd. #200 Portland, OR 97239 RE: WESTCON - REVIEW Project Information Building Permit: BUp2005.00590 Construction Type: III - Tenant Name: Westcon Occupancy Type: B/S Address: 14058 SW Milton Court Occupant Load: 80 Area: 12,408 sq ft Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and 2004 International Fire Code as amended by TVF&R. The following information is required in order to complete the review. 1. Provide information for separation between group B and the group S warehouse, OSSC 302.3.2 2. Provide information on travel distance and a possible 2 " exit required out of warehouse, OSSC 1013 3. Provide information on travel distance and 2 exit required out of the office space per OSSC 1014 November 7, 2005 CITY OF TIGARD O REGON CIDA, Inc Jennifer Beatie 4445 SW Barbur Blvd. #200 Portland, OR 97239 RE: WESTCON - REVIEW Project Information Building Permit: BUP2005 -00590 Construction Type: III -B Tenant Name: Westcon Occupancy Type: B/S Address: 14058 SW Milton Court Occupant Load: 80 Area: 12,408 sq ft Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and 2004 International Fire Code as amended by TVF &R. The following information is required in order to complete the review. 1. Provide information for separation between group B and the group S warehouse. OSSC 302.3.2 2. Provide information on travel distance and a possible 2nd exit required out of warehouse. OSSC 1013 3. Provide information on travel distance and 2nd exit required out of the office space per OSSC 1014 4. Provide information on rack storage commodity as required per OFC chapter 23. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully Val Henzel, Senior Plans Examiner 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 11/14/2005 15:26 5032261670 CIDA PAGE 01/04 • • 4443 SW BARBUR BOULEVARD, SUITE 200 PORTLAND, OREGON 97239 TEL 5 03.226,1285 FAX: 503.226.1670 E -MAIL: infof)cidninc.com FAX COVER LETTER Project No: 050090.01 Date: 11/14/15 Project Name: Westcon T.I. Remodel (Permit Number BUP2005- 00590) Time: 2:00 pm Attn: Val Henze! RECEIVED Fax: 503624.3681 NOV 14 2005 Company: City of Tigard CITY OF TIGARD Description: Plan Check Comments BUILDING DIVISION From: Elizabeth Kale Fax #: 503226.1670 Page 1 of 4 Comments: Please find the attached plan check response. Thank you. C: Jennifer Beattie, file Fax #: Originals to Follow: Yes Confidentiality Notice: The information in this fax is confidential and is intended only for the use of the individual or entity named above. if the reader of this message is not the intended red. Tent, or if this transmission was received in error •lease notif ARCHITECTURE • LNi= INLLRING • PI_ANN • INTERIORS • LANDSCAPE 11/14/2005 15:26 5032261670 CIDA PAGE 04/04 11/07/2005 10 :49 5036243691 TIGARD BUILDING DEPT PAGE 01/07. 'i :, retr f J . November 7 2005 G � /VA : sr 4 1 .a Ii� +, CITY OF TIGARD CIDA, Inc OREGON Jennifer Beatie ) s 0 4 4445 SW Barber Blvd. #200 �� D Portland, OR 97239 �v�°O� RE: WESTCON - REVIEW Project Information Building Permit: BUP2005- 00590' Construction Type: 111 -B Tenant Name: Westeon Occupancy Type: B/S Address: 14058 SW Milton Court Occupant Load: 80 Area: 12,408 sq ft Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and 2004 International Fire Code as amended by TVF&R. The following information is required in order to complete the review, 1. Provide information fbr separation between group B and the group S warehouse, OSSC 302.3.2 2. Provide information on travel distance and a possible 2 exit required out of warehouse, OSSC 1013 3. Provide information on travel distance and 2 exit required out of the office space per OSSC 1014 4. Provide information on rack storage commodity as required per OFC chapter 23. Approved Plans: I set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Buiilding Division inspectors throughout all phases of construction. 106.3.1 OSSC When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfull Val l enzel Senior Plans Examiner (5q w..4-36g 13125 SW Mal! Blvd., Tigard, OP 97223 (503) 639-4171 TDD (503) 684 -27'72 A • / g /v1 ,`! t vt C+ 4445 SW BARBUR BLVD., SUITE 200 PORTLAND, OREGON 97239 TEL: 503.226.1 285 FAX: 503.226.1 670 E - MAIL: info @cidainc.com www.cidainc.com November 2, 2005 City of Tigard Building Department 13125 SW Hall Blvd. Tigard, Oregon 97223 RE: Westcon T.I. Remodel CIDA Project Number. 050090.01 This letter is to document the accessibility barriers to be removed as required by the 2004 Oregon Structural Specialty Code Chapter I I. The construction budget for this project is $75,000.00; therefore, 25% of the value of construction would be $18,750.00. The existing building was constructed in 1996 and the tenant improvement was completed in 1997. The building was constructed to be ADA compliant, and the following is a list of areas where the building meets these specifications. All new work will meet ADA requirements. I — Parking: The existing parking is striped for (2) two ADA parking stalls. The parking will not be modified. 2 — Accessible entrance: Both of the existing entrances are ADA accessible. The path from the parking to the entrance is accessible. 3 — Accessible route to altered areas: All existing doors have ADA accessible hardware. All new doors are required to have accessible hardware. 4 — Accessible toilet rooms: All existing toilet rooms meet ADA accessibility requirements. The toilet rooms will not be modified. 5 — Accessible drinking fountain: The existing drinking fountain is ADA accessible. 6 — Additional elements: The new will call counter will have 36 inches of accessible counter at 34 inches high. Thank you for your review. Please call with any questions or comments. Sincerely, 0-A- Jennifer Be ttie Project Manager Enclosure: c: David Welsh, CIDA Liz Kale, CIDA File F: \GENADMIN \PROjECTS \05 \0090.00 westcon\ADA letter.doc ARCHITECTURE • ENGINEERING • PLANNING • INTERIORS • LANDSCAPE