Loading...
Correspondence " (7h ti April 13, 2005 CITY OF TIGARD OREGON CIDA INC Jennifer Beattie 4445 SW Barbur Blvd Suite 200 Portland, Or 97239 RE: CROWN CARPET Project Information L, Building Permit: BUP2005 -00023 Occupancy Type: M,B,S Tenant Name: Crown Carpet Construction Type: 3B Address: 12230 SW Main Street Area: 15,802 Sq Ft Occupant Load: M 260,B 26,S 21 = 307 Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition chapter 29 as allowed per State of Oregon. The submitted plans are approved subject to the following conditions. 1. Restrooms to be installed per approved plans and appropriate State codes. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, i al Hemel, Senior Plans Examiner 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Site Address: Letter of Transmittal 611!. Building Division City of Tigard DATE RECEIVED: TO: DEPT: BUILDING DIVISION • FROM: COMPANY: PHONE NO.: By: RE: (Case number, site address, etc.) (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: Copies: Description: Additional set(s) of plans. Revisions: Cross section(s) and details. Wall bracing and/or lateral analysis. Floor /roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other (explain): REMARKS: F or Office Use Only: Routed to Permit Technician: Date: Initials: Fees Due: $ Date: Initials: Reprint Permit (per Plans Examiner): Yes: No: (+ Notified Applicant: Date: Initials: isBuildingForms \LetterTransmittal.doc 1/6/04 4445 SW BARBUR BLVD., SUITE 200 PORTLAND, OREGON 97239 285 1 R c E, v TEL: 503.226.1285 FAX: 503.226.1670 iv info@cidainc.com Ap n www.cidainc.com ¢a rt 2005 April 12, 2005 C ITYOF T� G AR® City of Tigard Bu' LD'NG ov�s�o Attn: Val Hensel 13125 SW Hall Boulevard Tigard, OR 97223 RE: Plumbing Requirements for Crown Carpets Tenant Improvement • Plumbing Deferred Submittal Permit #: BUP2005 -00023 CIDA Project Number. 040103.01 Dear Val: I spoke with Richard Rogers, of the Building Codes Division, on April 1, 2005. He informed me that the Building Codes Division passed a motion to allow use of either the 2003 IBC or the 1 998 OSSC Chapter 29 for a duration of 180 days, until a final resolution is accomplished. Pertaining to the review of Crown Carpets, it is our request that the review be performed under the 1 998 OSSC Chapter 29. Below are the occupancy and plumbing calculations per 1998 OSSC Chapter 29 for the proposed remodel and expansion. Occupancy (Plumbing) Designations Square Footage IBC Table 1004. I.2 Total Occupants M(mercantile) 8284 I occ. /200 SF gross 41.42 S(storage) 6680 I occ. /5,000 SF gross 1.34 B(business areas) 2129 I occ. /200 SF gross 1 0.65 Required Water Closet Facilities Designations Occupants Ea. Sex UBC Table 29 -A Ratios WC Req'd Per Y2 of total occupants fixtures required calculation Sex M 41.42/2 =20.71 1/50 20.71/50 .4 I S 1.34/2 =.67 1/10 .67/ 10 .07 B 10.65/2 =5.32 1/25 5.32/15 .35 Total WC fixture .83 - I Required Lavatory Facilities Designations Occupants Ea. Sex UBC Table 29 -A Ratios Lavatories Req'd %2 of total occupants Per Sex M 41.42/2=20.71 I per 2 toilets (.41)1/2 .21 S 1.34/2 =.67 1/40 .67/40 .02 B 10.65/2 =5.32 I per 2 toilets (.35)1/2 .18 Total lavatory fixture .41 -- I per sex The minimum required plumbing fixtures per UBC table 29 -A is one toilet/lavatory per sex. We are providing the minimum required and an additional unisex toilet/lavatory. Please refer to T4. I for the locations. • ARCHITECTURE • ENGINEERING • PLANNING • INTERIORS • LANDSCAPE At this time, we are providing a door to the existing building connecting the portion of the building that is not being remodeled. The inclusion of the existing building results in the addition of 3 existing toilet rooms. Below are the calculations based on the entire building. Occupancy (Plumbing) - entire building Designations Square Footage IBC Table 1004.1.2 Total Occupants (fit M(mercantile) 1 2,059 I occ. /200 SF gross 60.29 S(storage) 8680 I occ. /5,000 SF gross 1.74 Ig B(business areas) 3542 I occ. /200 SF gross 17.71 Required Water Closet Facilities - entire building Designations Occupants Ea. Sex UBC tTable 29 -A Ratios WC Req'd Per 'A of total occupants fixtures required calculation Sex M 60.29/2 =30.15 1/50 30.15/50 .60 S 1.74/2 =.87 1 / 10 .87/10 .09 B 17.71/2=8.86 1 / 15 8.86/15 .59 Total WC fixture 1.28 -- 2 per sex Required Lavatory Facilities - entire building Designations Occupants Ea. Sex UBC Table 29 -A Ratios Lavatories Req'd %2 of total occupants Per Sex 60.29/2 =30.15 I per 2 toilets (.60) I /2 .3 �� I.74/2 =.87 1/40 I /0 1.74/40 .04 B 17.71/2=8.86 I per 2 toilets (.59)1/2 .30 Total lavatory fixture .64 -- I per sex The minimum required plumbing fixtures per UBC table 29 -A are (2) toilets /(I) lavatory per sex. The existing portion of the building has (I) ADA unisex toilet room and (2) standard toilet rooms. Please see T4. I for their location. This is in addition to the new (1) men's toilet room, (1) women's toilet room and (1) unisex toilet room, will provide a total of (6) toilet rooms, including (4) ADA accessible and (2) existing standard. This exceeds the required minimum. Although we currently meet the minimum standards we also feel that it is reasonable to discuss that Crown Carpets sells bulk products (carpet and other large flooring rolls). The occupancy falls within the definition of mercantile, but their product minimizes the actual square footage that patrons can occupy; therefore we believe it is reasonable to dictate a different ratio for the mercantile area based on actual usage. The Uniform Building Code allows for the plans examiner to take into consideration the actual use of the building when a different ratio is required per Section 29.02.2. With the proposed toilet rooms, the building will have more than enough facilities to serve all customers and employees. Thank you for your time, and please do not hesitate to call me at 503-226-1285 if you have any questions. Sincerely, 9 f /rys ibt_ a(0C6A; Jennifer Beattie Project Manager c: file 1 F: \GENADMIN \PROJECTS \04 \0I03.00_crown carpet \04 - I I - 05_tigard.doc Site Address: 122 v z 5th vfl . * -9 01 4 11h , Letter of Transmittal Building Division City of Tigard DATE RECEIVED: TO: Vats{ �K�► 3�i • • DEPT: BUILDING DIVISION RECEIVED APR 13 1005 FROM: CITY OF TIGARD b' BUILDING 6, I I 1 Int. • UILDING DIVISION PHONE NO.: SD3 Z2(D 12aS BY RE: FL "2ev.75 — (Case number, site address, etc.) .Ybu r, (AV p4- (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: I Copies: I Description: • • • I Copies: 1 Description: I Additional set(s) of plans. Revisions: Cross section(s) and details. Wall bracing and/or lateral analysis. Floor /roof framing. Basement and retaining walls. Beam calculations. Engineer's calculations. Other (explain): To► Swb m cHILQ REMARKS: P(aail -c_ f)1 m, -+ vv For Office Use Only • Routed to Permit Technician: Date: Initials: Fees Due: $ Date: Initials: Reprint Permit (per Plans Examiner): I Yes: I No: Notified Applicant: I Date: Initials: is Building •Forms\LetterTransminal.doc 1/6/04 February 8, 2005 CIDA INC Jennifer Beattie 4445 SW Barbur Blvd Suite 200 Portland, Or 97239 RE: CROWN CARPET • Proiect Information Building Permit: BUP2005 -00023 Occupancy Type: M,B,S Tenant Name: Crown Carpet Construction Type: 3B Address: 12230 SW Main Street Area: 15,802 Sq Ft Occupant Load: M 260,B 26,S 21 = 307 Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The following information is required in order to complete the review. 1. Provide additional restroom locations as required per Chapter 29 Table 2902.1. • M = 260 occupants require 1 each plus water fountain B = 26 occupants require 1 each S = 21 occupants require 1 each Total 3 water closet each in the male and female bathrooms. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully Val Henzel, Senior Plans Examiner //iueapdg li�� � • I{i\ February 8, 2005 �� CITY OF TIGARD OREGON CIDA INC Jennifer Beattie 4445 SW Barbur Blvd Suite 200 Portland, Or 97239 RE: CROWN CARPET Project Information Building Permit: BUP2005 -00023 Occupancy Type: M,B,S Tenant Name: Crown Carpet Construction Type: VN Address: 12230 SW Main Street Area: 15,802 Sq Ft Occupant Load: M 260,B 26,S 21 = 307 Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans are approved subject to the following conditions. 1. All exit doors shall be openable from the inside without the use of a key or any special " knowledge or effort. 1008.1.8 OSSC 2. The main exit shall be provided with signage indicating "THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS" 1008.1.8 OSSC 3. Exit signs shall be illuminated at all times and shall be provided with a second source of power that will provide 1 '/2 hours of illumination in case of primary power loss. 1006.3 OSSC FYI Additional exit signs may be required by the city field inspector to clearly indicate the path of egress. 4. The means of egress shall be provided with illumination of not less than 1 foot candle at the floor level anytime the building is occupied. The means of egress illumination shall be provided with a second source of power in case of primary power loss. 1006.2 OSSC 5. The clear height above and below the mezzanine floor construction shall not be less than 7 feet. 505.1 OSSC 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 l f 6. In buildings without an occupied roof access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet in area and having a minimum dimension of 2 feet. 1009.12.1 ex OSSC 7. American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC which may not include all of the requirements of the ADA. 8. Live Loads Posted: The live loads for which each floor has been designed shall be conspicuously posted by the owner in that part of each story in which they apply, using durable metal signs, and it shall be unlawful to remove or deface such notices. The occupant of the building shall be responsible for keeping the actual load below the allowable limits. 1603.3 OSSC 9. Safety glazing including but not limited to: the following locations: Each unit of glazing shall be permanently identified by the manufacturer. Sec. 2406. Some of these locations are as follows: a. Glazing in ingress and means of egress doors. b. Glazing in storm doors. c. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical edge is within a 24" arc of the door in a closed position and whose bottom edge is less than 60" above the floor or walking surface except when there is an intervening wall or other permanent barrier between the door and the glazing. d. Glazing that meets all the following conditions: In lieu of safety glazing, protective bar (1 1 /2" height minimum) may be installed on the accessible side(s) of the glazing 36" ± 2" above the floor. The bar shall be capable of withstanding a horizontal load of 50 plf without contacting the glass. Sec. 308.4 1) Exposed area of an individual pane greater than 9 sq ft. 2) Bottom edge less than 18" above the floor. 3) Top edge greater than 36" above the floor. 4) One or more walking surfaces within 36" horizontally of the glazing. e. All glazing in railings regardless of an area or height above a walking surface including structural baluster panels and nonstructural in -fill panels. Deferred submittals such as Fire Alarm, Fire Sprinkler, Truss Joist Shop Drawings, etc, will be charged a deferred submittal fee based on the valuation of the portion of the work being deferred. The minimum fee shall be $200.00. Deferred items; • Electrical • Plumbing • Fire Sprinklers • Mechanical System • Steel Joist • Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 110.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respect , nzel, Senior Plans Examiner •