Plans MAY -11 -2006 10 46 AIR COLD SUPPLY 5032805275 P.02
• J"- • 111YOSIC ULTRA HIGH EFFICIENCY GASIELECTRIC Date 05/11/2006 Page 1
It's 71me to Get Comfortable' UNIT Order No
Project Name Untitled /t 16 — Or0220
ArohlteCt •
Engineer fa3B -co Sb✓/iita,<A 5'j'
Purchaser
Submitted By •
QUANTITY: 1 UNITS DESIGNATION: schedule No: Model No: DJ048NOSN1AAA2
r COOLING PERFORMANCE
Total Capacity 49.0 MBH
Capacity Ca • ``"` �:::..:
Efficiency Y 35.0 MBH .,� ; :a.a s ,•, � N ° ��y' Y ' . a,> .,:
13.4 SEER ' ��, "�<
ficiency (at ARl) fh' r '• r . :. : 'R , y :.a <, t.5.•,•
.�• •`,fix.., �;.' >. . , , x�:� ., i
•` y .•4� i + J} N!f7� c / .vYk•".
F ti � y,, . >.`. :��
'.�:�.,_
^ j �'a ) 1. .�.:,� ^i "'4 }�.iR �'/[.•.J.
Ambient DB Temp 95.0 4 . - ` tf : ; '1 , . . < ^.>» .
DB Temp .0,.. w,.. ? M - —
Entering p 80.0 F -.3- a��' < :;I:� <:,•�a�'�k ,:; �.�; -
6
Entering WB Temp 67.0 F li
Leaving DB Temp 59.7 F • � • t. .,/4 ;A,;:;° r.;-.:.; •
Leaving WB Temp >s r w >' :.. •
Power Input (w/o blower) 3.40 KW .. z. :"
Elevation 0 Ft '` ••,,,W.,?,, r ya f„ l.
Sound Power 83 Dbels `•, - - :.'. ' ?
HEATING PERFORMANCE �
Gas Fired Input @ Sea Level 0 MBH " a-.` . -
Gas Fired Output @ Sea Level 59 MBH
AFUE % GENERAL FEATURES
Entering DB Temp 60.0 F
Leaving DB Temp 94.1 F.
• Solid State Control SUPPLY AIR BLOWER PERFORMANCE
• Solid State Control Board with Flash Code to Monitor System Operation
Supply Air 1600 CFM - Low Ambient to Zero Degrees
Outside Air 0 CFM - Complete Factory Package - Tested, Charged, Wired
External Static Pressure 0.60 IWG - Hermetically sealed Compressor
- Unit Underside Insulated
Duct Connection Location Bottom - Spark Ignition • Induced Draft with Post Purge Logic on Gas Fired Units
Blower Speed 970 RPM - Ambient Modified - TIme/Temperature Defrost Logic on Heat Pumps
Motor Rating 1.5 HP • Bottom or Side Duct Conteguration Capability
Power Input 0.80 KW - Low Voltage Relay Board With Terminal Strip
- PTC Type Crankcase Heater
Brake Horsepower 0 -86 BHP - Liquid Line Filter Drier
ELECTRICAL DATA • Plug-Type Wiring Harness Connectors for Economizers
• Permanently Lubricated Motors
Power Supply 208 -1 -60 - 24 Volt Control Circuit with compressor lock out protection
Total Unit Ampacity 29.1 Amps - Copper Tube/Aluminum Fin Coils
Maximum Overcurrent Device • 2" Fitter Rack with t" T/A Fitters
Fuse Size 35 Amps • High 8, Low Pressure / Loss of Charge and Freerstat
Protection Switches
I1ACR Circuit Breaker 35 Amps - as Access to all Electrical Components
DIMENSIONS & WEIGHT - Rigging Holes and Forklift Slots in Base Rails for Lifting
- Single Point Power Connection
Height 33 in Width 82 in Depth 45 in - Powder Paint Finish That Meets ASTM -8117, 1000 hr. Salt
Total Weight (incl factory options) 655 Lbs Spray Test Standards
CLEARANCES - CSA Agency Approval on all Units
- Factory Warranty
Front 32 in Back 12 in - One Year on the Complete Unit
Bottom' 0 in Top 72 in - Four Additional Years on the Compressor
Nine Additional Years on the Gas Fired Heat Exchanger
Left Side (filter access) 24 in
Right Side (outdoor coil) 24 in,
1. Untie may be inatelled on oombustble Hoare made from wood Cl Mae A 6 or 0 root cowering matenelc. A 1 in. clearance mot be mimeo between
2. Units muot be installed out doom. O.orb a mglrei stnreturee Of enrube should not obstrvcr condenser air isoharge oudat. any combustible malarial and the eupery air
Locate the unit so that the vent hood outlet is at least duCtwOrk fora Dietaries or 3 feet from the uret.
- 0 foot Dane any breed air Inlet located wlUiln 10 Noncoms' toot (e0oruUrng Shwa Integral to the en. . The produces of combos/ton must not be
• a feet below. 4 horizontal teat from. or 1 tool above any door or gravity air inlet to the budding. allowed to accumulate within 3 CbnOned
- 4 loot horn electric meters, gee meter.. regulators and reilel equipment space and r•oireulOte.
E$P2008 February 2008 suaaees to change wipeout notice - Chace local cease
•
MAY -11 -2006 10:47 AIR COLD SUPPLY 5032805275 P.03
i. "` , L wow. ULTRA HIGH EFFICIENCY GAS /ELECTRIC UNIT Date 05/11/2006 Page 2
Order No
It's Time to Get Comfortable"
OJ048N06N1AAA2
CONTROL BLOWER VENT AIR
FIELD - SUPPLIED BOX ACCESS OUTLET MOOD
DISCONNECT SWITCH ACCESS
LOCATION �r' V.4- " °tip CONDENSER
' COMPRESSOR
�r i It ;il, ACCESS
• l ' Li (l COMBI. 11ON AIR
....----• I . 1 I 11 INLET }WOOD
FILTER „u i
ACCESS -' I - .1 I 0 u Il l�:rl.II1 "fa j d -.r?i 7 RETURN AIR
3241$ I I •� (--) i �'� 7,, SUPPLY AIR
r�
•
I - - CONDENSER AIR
• 1 . .
� �, FRONT VIEW , -'' - G INTT
ACCESS ") OUTDOOR AIR
y � 4 I / (Economizer)
. /./..,- G AS SUPPLY
� • x /82 -U6 ENTRY
31e PVC FEMALE 64-7>Q '� 'j'"
COND. DRAIN Lr.2-12A. B ! 900
/ I
.
WIRING ENTRY i " 11 -12 6.12 ���' � CB A? M E C
17 -112 /'
5.319 6-14 1 �� "� p
' . �.• 17.12 GAS SUPPLY
�` \► 7.72 y6 3k r/ ! ENTRY
BOTTOM SUPPLY 5. i
&RETURNAIR � 32 -1N UNIT BASE WITH RAILS
OPENINGS
\) // Shown se pe►etety to (llustrete
4 •
POWER WRING ENTRY +/ bottom dud openbtgs, power eno
gee piping connection IoceIIor..
CONTROL WIRING ENTRY NOTE: For club- mounted units,
9.308 refer to to dud hanger dimensions
of the curb for the proper aka settle
soppy end return elr dud connections.
•
•
FILTER
ACCESS
Utilities Entry Dote i ,,,,,,,.,,,
hHole Opening Dia. Use 1 BLOWER MOTOR
ACCESS
A 718" KO Control Side or Bottom_ FIELD- SUPPLIED
B 2" KO Power Side or Bottom DISCONNECT SWITCN
C 1 -518" KO Front LOCATION
Gas Piping
., D 1 -1 I2 KO Bottom
1
FOR DISCON DISCONNECT sSWITCH t \�, . •
(Shipped *meted to the � i
Glower housing Inside
the blower campahrnent) / : •
//��
WIRING ENTRY CONTROL BOX
ACCESS
DISCONNECT SWITCH LOCATION
AND MOTOR ACCESS PANEL FOR
• . UNIT WITH BELT- DRIVE" OPTION
ESP200e February 2006 Subject to ohange without notice - Check IOCai codes
1
MAY -11 -2006 10:47 AIR COLD SUPPLY 5032805275 P.04 • '' ~ ULTRA HIGH EFFICIENCY GAS/ELECTRIC UNIT Date OS/11/2006 Page 3
Ws rime to Get Comfortable'
•
•
DJ048NO6N1AAA2 Order No
.._:, ,:_a_. I> RETURN AIR
_ � SUPPLY AIR
1 V
T.*, +•— •
•
.1 1:::,'"Z y • • _ �� CONDENSER AIR •
,::` �,.i OUTDOOR AIR
yM v . _ (Economizer)
r. �- _
• r--:. ; . r ; 1 I
::, . ti 11.1!2 9001. CERTIMID
VII -
h.
11111 . z....., r
17.112" 11 -1/2" • 6-1/2' = ` I
17-1/r w ): –.,.......1
--.,...4-
7-7 8'
REAR VIEW
SIDE SUPPLY AND •
- RETURN AIR DUCT
OPENINGS
UNITS WITH ECONOMIZER RAIN MOOD & FIXED OUTDOOR DAMPER HOOD
SUPPLY AIR DUCT OPENING - 7 1 M -1•619 ECONOMRER RAIN MOOD
- -- __ , i
RELIEF/FIXED
-- �... -. ,� . . .��— OUTD OOR AIR
I. - -- _ • -- -. 1 y ` DAMPER MOOD
— _ .-...—•
27 -1/2
I - 1.1_ _ _ 1 (L� 10.1/4
` _ B I —: 9.1r!
r I- �a'�TT _
lux : •.1� ' Y i
s sR 9.1
• l III . ...____ __7a. f
17 -112 7.716 —I 10.1!4 �- --- 44.7/ M3/4
REAR VIEW '
�1R� L.H. END VIEW
•
Notes:
•
E$P2006 Pobruary 2006 Subject to change Mont neaee - Check local Cease
•
1 .