Specifications • Mg_< -0` -0.3 3 Model number nomenclature Ccelitio) . . e Tf' 48TM004 -014 3 to 12 /2 Tons - ASHRAE 90.1 Compliant 0 4 Example: 48 TM D 006 P M F 6_ 1 HA • - o . o F. 48 - Packaged Rooftop HOPI. Electric Cooling/ ck Natural Gas Heat Packaging TM- Constant Volume, Standard Efficiency 3 _ � Exp tic Heat Options: California Compliant Design Changes 49 States L - Low NOx Low Heat D - Low Heat M - Low NOx Medium Heat E - Medium Heat N - Low NOx High Heat Voltage F - High Heat - 1 - 575 -3-60 3 - 208/230 -1-60 Tons Nominal Capacity --- 5 - 208/230 -3 -60 6 -.460-3-60 004 '- 3 Tons 005 - 4 Tons -'--") 006 - 5 Tons CoII.Protectlon Options (fin/tube) 007 - 6 Tons - - AVCu Cond & Evap 008 - 7.1/2 Tons B - Cu/Cu Cond & Evap 009 - 8 -1/2 Tons C - Cu/Cu Cond & AVCu Evap • 012 - 10 Tons . F - E -Coat AVCu Cond & AVCu Evap 014 - 12 -1/2 Tons G - E -Coat Cu/Cu Cond & AVCu Evap ' V AVCu Pre-Coat Cond Fin & AVCu Evap Controls and Sensors - None K - Novar ETM2024 Control' Indoor Motor O dons N - Novar ETM3051 Control' - - Standard Motor & Drive P - PremierLink*"c DDC Control • A - Altemate Motor • Z - Apollo Control M - High- Static Indoor Motor LEGEND 'Contact factory for availability and application Information. Al - Aluminum tRefer to 48TM Price Pages or contact your local Carrier representative for Cu - Copper FIOP code table. . FlOP - Factory- Installed Option ARI* capacity r . • UNIT NOMINAL NET COOLING ' TOTAL - SEEM EER" • SOUND RATING IPLVit 48TM TONS CAPACITY (Stun) kW (Bela) • 004 3 35,000 • " ' 4.0 10.0 8.7 8.1 N/A 005• - 4 47,000 - ' 5.3 • 10.0' 8.8 8.1 N/A • 006 5 57,000 6.7 10.0 8.5 8.1 N/A 007 6 71,000 7.0 - . 10.1. 8.0 • N/A 008 7V 88,000 8.7 - 10.1 8.2 10.5 009 8 100,000 9.9 - 10.1 8.2. 10.4 012 10 114,000 11.3 - 10.1 • 8.4 11.0 014 12 '/ 136,000 14.3 - 9.5 8.6 • ' 9.7 , LEGEND 2. ARI ratings are net values, reflecting the effects of circulating fan heat. Bela - Sound Levels (1 bel = 10 decibels) 3. Ratings are based on: _ db - Dy Bulb EER - Energy Efficiency Ratio IPLV - Integrated Part -Load Values s. (C-5,) SEER - Seasonal.Energy Efficiency Ratio `' t ` �. , ,' 'T AN : ` wb - Wet Bulb - 'Air Conditioning and Refrigeration Institute. s- ' tThe SEER values shown for sizes 004, 005, and 006 are for units with the optional belt drive motors; SEER rating for these units with the standard direct Cooling Standard: 80 F db, 67 F wb Indoor entering -air temperature and drive motor is 9:7. 95 F db air entering outdoor unit. "ARI does not require EER ratings for units with capacity below 65,000 Btuh. IPLV.Standard: 80 F db, 67 F wb Indoor entering -air temperature and 80 F For these units, the EER rating at ARI standard conditions Is provided for Infor- db outdoor entering -air temperature. motion only. 4. All 48TM004 -014 units are In.compllanoe with ASHRAE 90.1 2001 Energy 11 IPLV applies only to two-stage cooling units. Standard for minimum SEER and EER requirements. Refer to state and local codes or visit the following website: fi / /solsdce.crestorg/efficiency/ NOTES: b• ap to determine if compliance with this oar i56 stains tS��iPe 1. Rated In accordance with ARI Standards 210/240, latest revision (for sizes g ical area of the United States. 004-012) or 360, latest revision (for size 014) and 270, latest revision. • California, Maryland, Washington, Wyoming - and various local and state building codes adopted the ASHRAE; 90.1 efficiency standard on • October 29, 2001. • 50 ,p (1811 iWPD HEATING CAPACITIES AND EFFICIENCIES 4: oo 208 /230.1 -60 - SINGLE STAGE GAS HEAT -, UNIT INPUT CAPACITY OUTPUT CAPACITY TEMPERATURE MINIMUM HEATING EFFICIENCY p 48TM tat Stage 2nd Stage tat Stage 2nd Stage RISE (°F) AIRFLOW (CFM) ' AFUE (%) Steady State (%) C - 6004 74.000 - 57.000 - 1545 1180 80 80 4= F004 115,000 - 89,000 - 55-85 970 80 80 C 0005 ' 74,000 - 57,000 - 15-45 1180 80 ' 80 E005 115,000 - 91,000 - 35-65 1300 80 80 ,A F005 150,000 - 118,000 - 50-80 ' 1370 80 . 80 0008 74,000 - 57,000 - 15.45 1180 80 80 E006 115,000 - 91,000 - 35-65 1300 80 - 80 F008 150,000 - 118,000 - 50-80 1370 80 • 80 208/230 -1-60 - SINGLE STAGE GAS HEAT - LOW NOx • UNIT INPUT CAPACITY . OUTPUT CAPACITY TEMPERATURE MINIMUM HEATING EFFICIENCY 48TM let Stage 2nd Stage , 1st Stage 2nd Stage RISE (°F) AIRFLOW (CFM) AFUE (%) Steady State (%) M004 60,000 - 49,000 - 20-50 910 80 80 N004 90,000 - 73.000 - 30-60 1130 80 80 L005 60,000 - 49,000 - 20-50 910' 80 - 80 11005 - 90,000 - 73,000 - 30-60 1130 80 80 . NOW 120,000 - 98,000 - 40 -70 1300 80 - 80 L006 - 60,000 - 49.000 - 20 -50 910 80 80 11008 90,000 - 73,000 - 30-60 _ 1130 80 80 N008 120,000 - 98,000 - 40-70 ' 1300 80 80 208/230/460-3-60 - SINGLE STAGE GAS HEAT - LOW NOx UNIT INPUT CAPACITY OUTPUT CAPACITY TEMPERATURE MINIMUM HEATING EFFICIENCY 48TM 1st Stage 2nd Stage , 1st Stage 2nd Stage RISE ( °F) - AIRFLOW (CFM) AFUE (%) Steady State (%) M004 60,000 - 49,000 - 20-50 910 80 80 N004 90,000 - 73,000 - 30-60 1130 80 80 L005 60,000 - 49,000 - - 20-50 910 80 80 M005 90,000 - 73,000 - 30-60 1130 - 60 80 'N005 120,000 - 98,000 - 40-70 1300 80 80 L006 60,000 - 49,000 - - 20-50 ' 910 80 80 M008 90,000 - 73,000 - 30.60 1130 80 80 . 11006 120,000 - 98,000 - 40-70 - 1300 80 80 208/230/460/575 -3-60 - SINGLE STAGE GAS HEAT UNIT INPUT CAPACITY OUTPUT CAPACITY TEMPERATURE MINIMUM HEATING EFFICIENCY 48711 tat Stage 2nd Stage 1st Stage 2nd Stage RISE (°F), AIRFLOW (CFM) AFUE ( %) Steady State ( %) 8004 , 74,000 - 40,000, 59200 15-45 1220 80 80 D005 74,000 - 40,000 59,200 15-45 - - 1220 80 80 E005 115,000 65.600" 92,000 35-65 1320 80 80 0008 74,000 40,000 59,200 , 15-45 1220 80 80 8008 115,000 65,600 92,000 35-65 1320 80 80 0007 74,000 - 40,000 59,200 15-45 1220 80 80 E007 115,000 - 65,600 92,000 35-65 1320 80 80 0008 125,000 - 72,000 100,000 20-50 1860 80 - 80 0009 125,000 - - 72,000 100,000 20-50 1880 - 80 208/230/460/575 -3-60 - 2-STAGE GAS HEAT UNIT INPUT CAPACITY _ OUTPUT CAPACITY TEMPERATURE MINIMUM HEATING EFFICIENCY 48TH 1st Stage 2nd Stage 1st Stage 221d Stage RISE (°F) AIRFLOW (CFM) AFUE ( %) Steady State (%) F004 82,000 115,000 65,600 92,000 55-85 - 1010 80 80 F005 120,000 150,000 96,000 120,000 50-80 1390 80 80 F008' 120,000 150,000 96,000 120,000 _ 50.80 1390 80 80 - F007 120,000 150,000 96,000 120,000 50-80 1390 80 80 E008 120,000 180,000 96,000 144,000 35-65 2060 80 80 F008 180,000 224,000 144,000 179,200 45 -75 ' 2180 80 80 E009 ' 120,000 180,000 .96,000 144,000 35-65 2060 BO 80 F009 180,000 224,000 144.000 179,200 45 -75 2180 80 80 0012 120,000 180,000 90,000 144,000 35-65 2060 80 , 80 E012' • 180,000 - 224,000 144,000 •'179,200 ' • 35-65 2510 - 80 F012 200,000 250,000 160,000 200,000 40 -70 2650 80 80 0014 180,000 224,000 144,000 179,200 35-65 2510 80 80 6014 200,000 250,000 160,000 200,000 40-70 2650 80 80 51 • • -. Physical data - 48TM004 -007 C�,,.,.« ' UNIT SIZE 48TM E/F/M/N004 D/E/F/L/M/N005 D/E/F /UM/N008 \ D/E/F007 O NOMINAL CAPACITY (tone) 3 4 5 6 4 OPERATING WEIGHT (lb) O Unit AVAI• 460 470 490 615 C AUCu• 465 476 497 626 Cu/Cu* 468 482 505 637 Economizer et, EconoMi$er2 50 50 50 50 Roof Curbf 115 115 115 115 COMPRESSOR Reciprocating Scroll Quantity 1 1 1 1 No. Cylinders (per Circuit) 2 2 2 2 Oil (oz) 50 I 50 I 50 60 REFRIGERANT TYPE R -22 Expansion Device Acutroi Metering Device Operating Charge(Ib-oz) Circuit 1 4-5 I 8f I 7 -14 I 11-0 Circuit 2 - - CONDENSER COIL Enhanced Copper Tubes, Aluminum Lanced Fins Rows...Flns/ln. 1...17 2...17 1..17 1..17 Total Face Area (sq ft) 8.36 I 8.36 I 10.42 I 16.5 CONDENSER FAN Propeller Type NominalCfm 3500 4000 4000 4100 Quantlyy...Diameter (In.) 1...22.0 1...22.0 1...22.0 1...22.0 Motor Hp... 1 / 4 ...1100 1 / 4 ...1100 1 / 4 ...1100 1 / 4 ...1100 Watts Input (Total) 325 325 325 320 EVAPORATOR COIL Enhanced CopperTUbes, Aluminum Double -Wavy Fins Rows...Fins/In. 2...15 2...15 3...15 4...15 Total Face Area (sq fl) 4.17 I 5.5 I 5.5 i 5.5 EVAPORATOR FAN Centrifugal Type Quanttly...Slze (In.) Std 1...10x 10 1...10 x 10 1...11 x 10 1...10x 10 Alt 1...10x10 1...10x10 1...10x 10 - Hlgh- Static 1...10x 10 1...10x 10 1...10x 10 1...10x 10 Type Drive Std Direct Direct Direct Bett Alt Belt Belt Belt - Hlgh-Static Belt Belt Belt Belt Nominal Clan 1200 1600 2000 2100 Maximum Continuous Bhp Std .34 .75 1.20 2.40 Aft 1.20 1.20 1.30/2.40'• - HI Static 2.40 2.40 2.90 2.90 Motor Frame Size Std 48 48 48 56 Aft 48 48 56 - 56 56 56 56 Nominal Rpm High/Low Std lc 860/800 1075/970 1075/970 - Alt 1620 1620 1725 - Hlgh- Static 1725 1725 1725 1725 Fan Rpm Range Std - - - 1070-1460 Alt 760 - 1000 835- 1185 900-1300 - Hlgh- Static 1075 -1455 1075 -1455 1300 -1685 1300 -1685 Motor Bearing Type Ball Ball Ball Ball Maximum Allowable Rpm 2100 2100 2100 2100 Motor Pulley Pitch Diameter Min/Max (In.) Std - 2.8/3.8 Alt 1.9/2.9 1.9/2.9 2.4/3.4 - Hlgh- Static 2.6/3.8 2.8/3.8 3.4/4.4 3.4/4.4 Nominal Motor Shaft Diameter (In.) Std 1 /p 1 / Z 1 / Z 6 /8 - Alt If High-Static 5 // 5 //8 7/ ye Fan Pulley Pitch Diameter (In.) Std - - - 4.5 Alt 4.5 4.0 4.5 - Hiah- Static 4.5 4.5 4.5 4.5 Belt, Quantlty...Type...Length (In.) Std - - - 1...A...40 Alt 1...A...34 1...A...34 1...A...39 - Hlgh•Static 1...A...39 1...&..39 1...A...40 1...A...40 Pulley Center Line Distance (In.) Std - - - 14.7 -15.5 Alt 10.0 -12.4 10.0 -12.4 14.7 -15.5 - HIgh-Static 10.0-12.4 10.0 -12.4 14.7 -15.5 14.7 -15.5 Speed Change per Full TUm of Std - - - 80 Movable Pulley Flange (rpm) Alt 48 70 80 Hlgh- Static 65 65 60 60 Movable Pulley Maximum Full Awns Std - - - 5 From Closed Position Alt 5 5 5 - Hlgh- Static 6 6 5 5 Factory Setting Std - - - 3 Alt 3 3 3 - Hlgh- Static 3 3 3 3 Factory Speed Setting (rpm) Std - - - 1225 Alt 856 975 1060 - High.Static 1233 1233 1396 1396 Fen Shaft Dlameter at Pulley (in.) 6 /8 6 /8 6 /6 6 /8 LEGEND "'Three-phase standard high heat models have heating input values as shown. Al - Aluminum Single -phase standard high heat models have one -stage heating with heating Bhp - Brake Horsepower input values as follows: Cu - Copper 48TMF004 - 115,000 Btuh 48TMF005,006 - 150,000 Btuh 'Evaporator coil fin material/condenser coil fin material. Contact your local repro- fffCalifomla SCAOMD compliant Low NO, models have combustion products sentative for details about coated fins. that are controlled to 40 nanograms per joule or less. fWeight of 14-In. roof curb. **Single phase/three- phase. NOTE: High-static motor not available on single -phase units. ffRollout switch lockout Is manually reset by Interrupting power to unit or resetting thermostat. 52 48T■004 -014 .. • N UNIT STD. UNIT WRABLADE ECONOMISER2 ECONOMI8ER2 (A) (8) (C) (0) BOTTOM POWER CHART, C@WECTION SIZE5 WEIGHT 0000 WEIGHT WEIGHT 8/ P.E. WEIGHT CORNER WEIGHT CORNER WEIGHT CORNER WEIGHT CORNER WEIGHT TI-ESE REO'D FOR USE A ) 3/8" 0(A. [351 FIELD POWER SUPPLY HOLE L85. KG. LBS. KG. LBS. KG. 185. KG. LBS. KG. L85. KG. L85. KG. LBS. KG. PANEL LENGTH WITH ACCESSORY PACKAGES - 8 2' DIA. (5)1 POWER SUPPLY KNOCK -Our 48T_ W 004 460 209 34 15.4 50 22.7 90 40.9 140 63.5 105 47.6 159 72.1 56 - 25.4 1' -(0 3/8' (568.0] CRBTYROOIA00; 3800 (1/2',3/4 ") C 2 I/2" DIA. [64) POWER SUPPLY KNOCK-OUT 4BT_ 06 490 222 I I • _ I 150 68.0 1)5 52.2 (60 72.6 65 29.5 I 1' 0 3/8" [3)58 OJ1 CONDUIT MIRE REO �x 5 E 3 - 114 DIA. POT CONDENSATE CONTROL 6)8 WIRING ROLE . CONDUIT USE SIZES F 1/2' - 14 HPT GAS CONNECTION 1/2" 24V 7/8"(22.21 _ NOTE51 3/4" POWER. 1 )/8 "(28.41 CIL (003) 1 /2 "FPT GAS 1 I/4 %31.8) 1. DIMENSIONS IN [ 1 ARE IN MILLIMETERS. OUTSIDE 8)0 FILTER ACCESS PANEL moss ' (DISPOSABLE FILTERS) 2. 0 CENTER OF GRAVITY. REAR jr F/ 0 806 EXHA 2'-9 3/8 [848] • , S • UST NO S r 3 3. �� DIRECTION OF AIR FLOP. .. 3' -I 1/2" 2' -0 15/16' [633] 0' -4 1 /2" • CD DUCTWORK ° -[1141 4. ON VERTICAL DISCHARGE UNITS, CTYORK TO BE ATTACHED F/ DURABLADE ECON BLOCKOFf • TO ACCESSORY ROOF CURB ONLY. FOR HORIZONTAL DISCHARGE CONDENSER COIL . - PANEL UNITS FIELD SUPPLIED FLANGES SHOULD BE ATTACHED TO _ (' -4 3/8' Cot 61 y HORIZONTAL DISCHARGE. OPENINGS, AND ALL DUCTWORK SHOULD COMPRESSOR ECONOMIZER HOOD F/ DURABLADE ECON BE ATTACHED TO THE FLANGES. . TEss■ 5. MINIMUM CLEARANCE (LOCAL CODES OR JURISDICTION MAY CO)JNF,R - ACCESS COVER_ I 0 1' -5 1 /4" [4381 VIEW 5-5 0. BETWEEN UNIT, FLUE SIDE AND COMBUSTIBLE SURFACES, 8 CORNER "B" 0/ ECONOMI8ER2 36 IN. 18 IN. WHEN pUSING 0 gA1CCE5S[SC600CFLUE W DISCHARGE DEFLECTOR. \ SEE NOTE 48 \ ` 4 I b C BrI NCHir T BOT p TOM M OF BISE 70ECLOf18U5TIB1'E U5(NG y 111 1 ��� SURFACES (WHEN NOT USING CURB) 0 INCHES. I / -- - - "- I ___2 [652] "-• �0'C8 y c ONE SIOE 12 INCHES THE�OTHER. 165 5)0E GETTING THE L EFT 1.(,' (17- / 1 GREATER �LEARANDE IS 10 A5SNAL. S IDE Ili 0'- 1015/16" / .. RETURN AIR i // I O. OVERHEAD, 60 INCHES TO ASSURE PROPER CONDENSER FAN 1 1 RETURN -AIR OPENING OPERATION. II 1 VERTICAL [27 // e. BETWEEN UNITS, CONTROL BOX SIDE, 42 IN. PER NEC. I II I ) 8 r0 -5 3/8" 1 /% L f. BETWEEN UNIT AND UNGROUNDED SURFACES, CONTROL BOX I I I [137] 1 " -8 ( /4' [5141 SIDE, 36 IN. PER NEC. /�/ I f/� b R I GHT S IDE 1 / i // g. BETWEEN UNIT AND BLOCK OR CONCRETE WALLS AND OTHER 3 - -9' - „ f � _ _ _ _ I `/ '- 0 7/8' CO GROUNDED SURFACES, CONTROL O% FS B SIDE, 42 IN. PER NEC. (1144] 1 11 - �/ T \ [22.2] • h. HORIZONTAL SUPPLY AND RETURN END, 0-INCHES WHEN THE 1� ,1 E / / [65] 1 �0' -2 9/16" ALTERNATE CONDENSATE DRAIN IS USED. -� 1 1 ALT. CONDENSATE I _ ECONOMI>tER2 6. WITH THE EXCEPTION OF-.THE CLEARANCE FOR THE CONDENSER 1 RAIN OPENING N BASEPAN COIL AND COMBUSTION SIDE AS STATED IN NOTE X50, b, r ll• 2'-0 1 /q" 0 "[9917/8" I (SUPPLY -AIR( 1,' -5 3/4" /�j SUPPLY AIR 1C470] ---1 AND c, A R EMOVABLE FENCE OR BARRICADE REQUIRES NO 2[622] (6(6] i��f. j. -� 8 1 EVAPORATOR OPENING [451] /' CLEARANCE. J . I COIL VERTICAL 1 b ir 0' -1 15716" 1 O 7. UNITS MAY BE INSTALLED ON COMBUSTIBLE FLOORS MADE l� 4 [49) _ � 1 1 1 - - - 0 FROM WOOD OR CLASS A, 8, OR C ROOF COVERING MATERIAL 0• -1 7/5 0 -1) t /2" 0 -3 5/16" . - 0' -S 7/16" 1•-8 1 /4' [5141 / IF SET ON BASERAIL. [44.5] / [290] [99,41 [138] / / 8. THE VERTICAL CENTER OF GRAVITY IS 1' -6 "[457] UP FROM CORNER "D -/ SEE BOTTOM POWER - P L / / THE BOTTOM OF THE BASE RAIL. CHART(ELEC. ONLY) FRONT � ` _ 0 ELECTRICAL CORNER "0" 0' -3 • 1 /16b, ,-0 1/15;, 0 -3 3/16 CORNER "C" 0' -7 l /4" '� ' - 7/16%11.I.1 D /� p A " � (78] [306] �'�[81] [1841 0 LOCATION I .2• -11 11/16' .•- 1O.t3n_.' ECONOMI SER2 - [906] - 1 0' -4 1 /16" A\ 6' -t n /t6" Y/ POWER EXHAUST a) 0' -3 13/16' (1872] [439.7] [274'.67 (103.2] [97] 0' - O 3/ 'FILTER ACCESS PANEL I r � ����t (DISPOSABLFILTRS) t 4 - H _ 8 FLUE HOOD 1' -6 t /8' 1 - 2-t 1)/16" DURABLADE ECON 7 CONTROL BD%/ - [460] I i RET R 1 (652.5] H0� FILTER • CONDENSER COIL A B(1RNFANELCE55 (50006 FAN MOTOR 6 I OPENING I - 2-9 5 /16" . - BLOWER ACCESS PANEL H051- I [846.5] , 1-4 5 /16" 1 ZONTAL I (414.5] I \- I ' [5. p - 11 7/8', . SU PPLY -AIR \ 7 33 00164(T D - 0-4 3/16 130t.6] . OPENING . 1 77 - OUTSIDE AIR [106.37 1 HORIZONTAL -1 1 L i �?% / ��� m - [168.2] . < O pO 1 1,, [206.2] ^( 0 I ---7 - (746.2] 2' 5 3/8" 4 FORK TRUCK SLOTS / 0' -S 3/4 "F - 2' -) 15/16 " - �•- 1 0 . -5'11/16' 0' -4 •/161 lYP 3' -S 3/16' 0' -8 [658.6) 7/16" ((46) . G ,. - [144.3] (115.8) 0' -2 9/16 (1046] BURNER ACCESS [214] 0 -2 1[67] IA OUT IDE SUPPLY AIR - RETURN'. AIR [65] LEF T 5 IDE P81401 FRONT (TY0 8 PLACES) OF PANE` R IGHT S IDE �''� E STD. CONDENSATE DRAIN . . 1■ ' DINE 6 -422.2 August, 1999 + A f -L �_N~' __F__; SUBMITTAL DATA , 1,___•1 M a X - ) D gas -fired unit heaters _LI { a 11 models PD & BD EE w I ` . I". D(OPFNDID) -L. I j L I mm (MIN. DISTANCE TO WALL) 1 %in., Dimensions (Inches) — PD Do not use propeller units with duct work Dimension Mudd Nub Symbol PD 30 PD 60 PD 76 PD 100 PD 125 PD 160 PD 175 PD 200 PD 260 PD 300 PD 350 PD 400 A 12 -7/8 17 -1/4 17 -1/4 19-1/4 19-1/4 21 23-1/2 25-5/8 25-5/8 28-5/8 33-5/8 40 B 24-1/4 24-1/4 283/4 28-3/4 35-1/4 35-1/4 35-1/4 40-1/4 40-1/4 40-1/4 40-1/4 40-1/4 C 14-3/4 14-3/4 20 20 22 22 22 25 25 25 25 25 D 10 -7/16 14 -13/16 14 -13/16 16 -13/16 16-13/16 18-9/16 21 -1/16 23-3/16 23-3/16 26-3/16 31 -3/16 37-1/2 E 13 13 16 16 20 20 20 24 24 24 24 24 F 9-1/4 9-1/4 11 11 12 12 12 13-1/2 13-1/2 14 — - O 2 2 23/4 2-3/4 3-5/8 3-5/8 3-5/8 4-3/8 4-3/8 4-3/8 4-1/4 4-1/4 H 9-1/4 13-5/8 13-5/8 15-5/8 155E 17-3/8 19-7/8 22 22 25 30 36-3/8 J® 3 4 5 6 6 7 7 7 _ 8 9 10 10 K m 3/8-16 3/8-16 3/8-16 3/8-16 ' 3/8-16 3/8-16 3/8-16 3/8-16 3/8-16 3/8-16 3/8-16 3/8-16 (Mounting Hdes) L S. 28-1/4 28-1/4 36 36 36-1/2 37 -1/8 37 -1/8 40-7/8 41 42 -1/4 42 -1/4 47 -1/4 W - - - - - - - - - - 5 5 X - - - - - - - - - - 16 16 M 5 5 6-1/4 _ 6-1/4 8 8 8 9 9 9 9 9 BB 6-1/4 6-1/4 6-1/2 6-1/2 7 -1/4 7 -1/4 7 -1/4 7 -1/4 7 -1/4 7 -1/4 7 -1/4 7 -1/4 EE 22 -1/4 22 -1/4 29 29 • 30-1/2 . 30-1/2 30-12 32 -7/8 32 -7/8 32 -7/8 32 -7/8 32 -7/8 LL 19-1/2 20-1/8 30 30 30 31 -1/8 31 -1/8 34-7/8 34-7/8 36-1/4 36-1/4 41 -1/4 Gas Connections 'x 1/2 1/2 1/2 1/2 _ 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 Fan Diameter 9 12 12 14 14 16 18 20 20 22 22 24 Apprmc. Weight 58# 72# 102# 116# 152# 162# 169# 231# 231# 261# 330# 410# M Diameter of round Vert pipe to fit oval opening. M For natural gas; new vary depending on camroI availability. ) PD 30 through PD 300 — 2 holes (and the level hanging adjustment feature). PD 350 through PD 400 —4 holes. Listed Is the Me diameter and threads per Inds to soospt threaded rod. (4) Dimension equals overall plus 6'. Performance — PD Inputs and outputs are the same for BD as PD M odel Number er PD 30 PD 50 PD 75 PD 100 PD 126 PD 150 PD 175 PD 200 PD 250 PD 300 PD 350 PD 400 , B(uMr. Input 30,000 50,000 75,000 100,000 125,000 150,000 175,000 200,000 250,000 300,000 350,000 400,000 Btu/Hr.Oulput 24,000 40,000 60,000 80,000 100,000 120,000 140,000 160,000 ` 200,000 240,000 280,000 320,000 Entering Airflow (CFM) 440 740 1100 1460 1850 2180 2550 2870 3700 4460 4870 5440 OutetVelodty 515 610 736 860 870 931 959 819 1053 1123 1068 1016 Air Temp. Ilse (°F) 51 50 51 51 - 50 51 51 52 50 50 53 54 Max. Mounting Hgt (Ft) ® 7 9 12 14 14 16 17 15 19 21 20 19 Heat Throw (Ft) CID (Max. Mtg. Hgt) 25 33 41 49 51 55 59 51 67 74 70 69 Motor Horsepower 1/40 1/40 1/12 1/12 1/8 1/8 1/6 1/6 1/3 1/2 3/4 3/4 RPM 1550 1550 1625 1625 1625 1625 1075 1075 1075 1075 1125 1125 Data Type Shaded Shaded Shaded Shaded Perm. Perm. Perm. Perm. Perm. Perm. Perm. Perm. M Pole Pole Pole Pole Split Cap. Split Cap. Spit Cap. Spirt Cap. Spirt Cap. Split Cap. Spirt Cap. Split Cap. U Power - Ralq (amps) 1.3 1.3 1.9 1.9 2.6 2.6 3.1 3.1 5.7 7.8 8.4 8.4 Ratings shown are for elevations up to 2,000 ft. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. (In Canada see rating plate.) (1) At 65 °F ambient and unit fired at full -rated Input. Mounting height as measured from bottom of unit, and without deflector hoods. ® All single phase motors are totally enclosed and thermal overload protected. Data listed Is for standard 115 -volt, 60 hertz, single -phase motors. page 1 o12