June 3, 2005
City of Tigard, Building Department
Attention: Val Henzel
13125 SW Hall Blvd,
Tigard, OR 97223
Fax: 503 -684 -7297
RE: Crown Carpet Building Remodel
12230 SW Main Street
Tigard, OR 97223
City of Tigard Building Permit BUP2005 -0 I
CIDA Project Number 040103.01
Dear Val:
CIDA has conducted structural observations in accordance with the 2004 Oregon Structural Specialty
Code for the above - mentioned building. To the best of our knowledge, no deficiencies remain.
Please do not hesitate to call if you have any questions.
Si,. - 1`
President
c: Doug Lepper, Crown Carpet 503 -288 -6900
Dave Curtis, Yorke and Curtis 503 -643 -2123
Curtis Gagner, CIDA
File
F:IGENADMIN\PRO EC1'S109 \0103.00 crown ca •et\06 - 03 - 05 STRUCT SIGN OFF LETTEP doc
ARCHITFC:TURl_ • F_f\IGINEERINC, • PI ANNIN • INTERIORS • I_ANDSC.API
January 21, 2005
CITY OF TIGARD
OREGON
CIDA INC
Jennifer Beattie
4445 SW Barbur Blvd, Suite 200
Portland, OR 97239
RE: CROWN CARPET SHELL ONLY REVIEW
Project Information
Building Permit: BUP2005 -00001 Occupancy Type: M,B,S
Tenant Name: Crown Carpet Construction Type: III -B
Address: 12230 SW Main St. Occupant Load: Shell only
Area: 23,750 Sq Ft Stories: 1
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004
edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The
submitted plans are approved subject to the following conditions.
1. All exit doors shall be operable from the inside without the use of a key or any special
knowledge or effort. 1008.1.8 OSSC
2. The main exit shall be provided with signage indicating "THIS DOOR MUST REMAIN
UNLOCKED DURING BUSINESS HOURS" Section 1008.1.8.3 OSSC
3. Exit signs shall be illuminated at all times and shall be provided with a second source of
power that will provide 1 1 /2 hours of illumination in case of primary power loss. 1006.3
OSSC FYI Additional exit signs may be required by the city field inspector to clearly
indicate the path of egress.
4. The means of egress shall be provided with illumination of not less than 1 foot candle at
the floor level anytime the building is occupied. The means of egress illumination shall be
provided with a second source of power in case of primary power loss. 1006.2 OSSC
5. Provide one 2 -A rated fire extinguisher in the new area. The extinguisher shall be located
so that no usable space has a distance greater than 75 feet to the extinguisher. Standard 10-
1, Chapter 3 TVFR99 -01.
6. Special Inspection: Special inspection is required for items listed on sheet S0.1. The
special inspection agency of record shall furnish inspection reports to the Engineer of
Record, Steve Young, the General Contractor, Yorke & Curtis, Inc. and the City of
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
Tigard, Building Division, attention Hap Watkins. All discrepancies shall be brought to
the immediate attention of the general contractor for correction. The special inspector shall
submit a final signed report stating whether the work requiring special inspection was, to
the best of the inspector's knowledge, in conformance with the approved plans and
specifications and the applicable workmanship provisions of the code. 1704 OSSC
7. American with Disabilities Act (ADA): It shall be the responsibility of the Architect,
Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the
ADA requirements for the structure. The City of Tigard reviews the plans and inspects the
structure only for compliance with Chapter 11 of the OSSC, which may not include all of
the requirements of the ADA.
8. Live Loads Posted: The live loads for which each floor has been designed to exceed 50
psf shall be conspicuously posted by the owner in that part of each story in which they
apply, using durable metal signs, and it shall be unlawful to remove or deface such notices.
The occupant of the building shall be responsible for keeping the actual load below the
allowable limits. 1603.3 OSSC
Deferred submittals such as Fire Alarm, Fire Sprinkler, Truss Joist Shop Drawings, etc, will be
charged a deferred submittal fee based on the valuation of the portion of the work being deferred.
The minimum fee shall be $200.00. Deferred items;
• Electrical
• Fire Sprinklers
• Mechanical System
• Steel Joist
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be
maintained on the jobsite. The plans shall be available to the Building Division inspectors
throughout all phases of construction. 106.3.1 OSSC
Certificate of Occupancy: No building or structure shall be used or occupied until the Building
Official has issued a certificate of occupancy 110.1 OSSC
Premises Identification: Approved numbers or addresses shall be provided for all new buildings
in such a position as to be plainly visible and legible from the street or road fronting the property.
When submitting revised drawings or additional information, please attach a copy of the enclosed
City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in
tracking and processing the documents.
Respectfu 1 ,
,1/17 zse-
Val Henzel,
1 Senior Plans Examiner