Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
Nov 09 OS 05:36p Froelich Consulting Eng 503- 624 -9770 p.2 i'l racr' -c' 2 . KE 1 y9So so L. c kcrt ,fir FROELICH CONSULTING ucry ENGINEERS INC s Ia R , � x,00 PROFF GINE.. `e MAIN OFFICE 0 CENTRAL OREGON 0 IL 1547' 6969 SW Hampton Street 231 SW Scalehouse Loop, Suite 101 O` , i r Tigard, Oregon 97223 Bend, Oregon 97702 503.624- 7005/503.624-9770 FAX 541.383- 1828/541.383 -7696 FAX _�� MEMORANDUM 5 1 P 'C Date: November 9, 2005 ' I DE F Wyatt JEXPIRES : / / * //a I From: Mike Young Subject: Arbor Summit, Lot 14 At the request of the City of Tigard, a site walk -thru has been completed and the following items addressed: (Items previously numerated by the City of Tigard) ( #1) Sheath interior of pony wall at front of garage — sheathing not required. (#2) Joist bearing on pony wall at front of elevated garage slab — Simpson A35 clips to be added to joist blocking at 48" o.c. (#3) Joist grade requirement for elevated garage slab — Design calculations are based on 2x12 DF#2 Joists at IT o.c. (#5) Block edges of plywood panels in garage — connections are adequate. (#6) Beam bearing over foundation vent — vent has been removed and the void has been filled with non shrink grout. ( #7,8) Exterior wall beam bearing points under elevated garage slab — modifications per FCE have been completed, bearing is adequate. (see attached sheets) (#8) Header size around opening for heater duct through elevated garage slab — (2)2x12 DF#2, existing framing is adequate. ( #12) Block joists at beams — Joist blocking is adequate. In addition to the items numerated by the City of Tigard, it was discovered that the roof truss connections to the double top plate were not in compliance with the structural drawings. To this FCE offers the following two remedy options: 1) To the existing Simpson H2.5 clip present at the inside face of the double top plate at each truss, add another Simpson H2.5 clip to the outside face of the double top plate at each truss. 2) To the existing Simpson H2.5 clip present at the inside face of the double top plate at each truss, add a Simpson LS50 clip to the existing truss blocking at 48" o.c. cc Nov 09 05 05:36p Froelich Consulting Eng 503 -624 -9770 p -3 ,, NOV -01 -0� 1::Y0 Ffl06� -Arbor Sumr `oint • 503 -4403 T - 903 P.001 /003 F - 368 West Hills . - . ..,_..• MEMO. DATE: 1 1 - 1- 0 3 • ARBOR PROJECT: - : 0 - Ae8vg: SL'Nw"i.T'. • • FROM: - wvA TT ZWAV riki vgE , • TO: 1 E Younm • s Lc -r. . ii:i E1.6UArE.p G,qr( se, FCE Udb* 0.S - T 25 Mi KE 11-1E Following Sr`ruATio05 EDLIST• Ar lifa END of. eaci4 Sewn- *I i y 7al X1 _ .�...`._ ... -- -� . _ ST Pa:Jove, _6Xia 1 a • -1 3"./1 N Slit Fouwpariop Wefir UNDER Beam F00113 # RXID • . 317'sr A.ba e, • ICIII `�� MUo Si 1 l Ile a oY' Ou iZ inspeC.Tb 2 (S l ooldns FOR P► esePcP-1n3 SowrioJ Ar AU- Foun- Lao:MOMS. TuE reesow Foe- drFf ''r si Tu nniow:s is Won toe. Decg. t5 sLOpe d F The coocrefe SLAB • Wag 3' %� P EASE CALL Ina ti)1'114 Quesn 114AOKS -• Fc snNy ta3.waTr • 503 '"19�' � � Ps. we cpor4O r P fob torrtL- TIILS IS cEolao2iD .. a!0F3 Nov 09 05 05:36p Froelich Consulting Eng 503- 624 -9770 p.4 & NVV 1,Mlb Iu:[u rkura-A ran r burr 'a In • 01,14 /4 I r.uuccuui r - 000 • pZDW Q oiSr Above „I?- Mwo Si U. • L 1 4 . GUI D 7o15r 14bodR.- ;i;"!1 6xi 3x4 Pit ROT (ctairrniN /%,, . a. F3 Nov 09 05 05:36p Froelich Consulting Eng 503 - 624 -9770 p.5 ❑ 6969 SW Hampton Stre.. CLIENT: / � !`S PAGE / • Tigard, Oregon 97443 RR L . FAX 503.644.9770 PROJECT: 615-- PI r or Su M M, FROELICH 503.644.7005 LOT ■ 4 . CONSULTING ° Ben O reg o1 P n 9770400p • Suite 101 PROJECT NUMBER: oS ENGINEERS INC .3 ; 8 4 8 6 96 DATE: 11/ 2 /o 5 ■ BY: .4%09,1 A zu4t &�• Avsw- 7D GzveSTiory # 2. $, # it/ora - aye rive ✓tee de -e<; ( 2 ectMc"tfo.,/ 4. . n 1) o j • &'x►Z. 3)(,;)l NEW RT. .1)4(x 5TuO • .. M IL. To Gala wall e r2 l� . � 15 ,`_ :� kilclq r!� coda. • Nt w 2 x Le OF 0 2 sTun • - _(-:, WI- To e.T,' O W/ c0 el € e • —._____ Wei MEW RR7: T Ple EY !z` / . Ye" lb Coble. FT /. Q f f /crde.6 0 .. I Nov 09 05 05:37p Froelich Consulting Eng 503 - 624 -9770 p.6 1 v AdNL j ' °_ I ; Ike 5 ;; SD SD , i ®x10 p .r TYP 0® i I2 OC �er IF WOOD C 5• i - y- E. PE D E 's : a t i O .— lS' 12:2— 6 — i il r;:1 , Lj —� — 0 o L# •: ; 3 4 STD r + ■ ■ 01 0 4127 s+ 6 1 ` ? �' � � ,�c0 fir" 5 L .i •B7 `• �iJ SIM LU5214 -2 � O • 1 l A Q� ri,, HANGER TYP m m I 0 e 0 ' ; 2 x12pF� A1 1 � O p i nu I, e , c, j' S >' J 1 C [' e 71_ :::J 0 Ili i ,-., i a L71 I° tI sl `_, 4' MAX. CONCRETE © • ^� TOPPING OVER 3 4' ` : .. , P.T. PLYWOOD -; SD SD . TYP ID O ® C ' I GARAGE ".; :1 ! ri . 13 3 i O u O II ❑ e o �,o o- SD :,i ? TYPa I I 6x6 DF°2 POST W/ SIMPSON BC6 _GARAGE I POST CAP SIMPSON ABU66 POST SD BA6E WI 5 /8'4) x 3' MN EMBED L I ) WEDGE ANCHOR - TYP 35 /el) ib %aba 35 REQ': As - 1 �i _11 I15I Y-■