Loading...
Permit MASTER PERMIT -CITY OF TIGARD DATETISSUED:.09 /24/96 �Zl�r 7 COMMUNITY DEVELOPMENT DEPARTMENT 13125 SW Hall Blvd. Tigard, Oregon 97223.8199 (503) 639 -4171 PARCEL: 25 1+Zi4DC— HWObEl SITE `ADDRESS... : 14296 SW LUKAR CT SUBDIVISION....: HILLSHIRE WOODS ZONING: R -7 PD ELOCK.......,.. LOT .............:58 Remarks: Path I BUILDING -- REISSUE: STORIES • 2 FLOOR AREAS--- - - - - -- BASEMENT...: 0 sf REQUIRED SETBACKS - - -- REQUIRED CLASS OF WORK.:NEW HEIGHT • 26 FIRST • 931 sf GARAGE • 440 sf LEFT : 6 SMOKE DETECTRS: Y TYPE OF USE...:SF FLOOR LOAD • 40 SECOND...: 732 sf FRONT : 20 PARKING SPACES: ! TYPE OF CONST.:5N DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT • 13 OCCUPANCY GRP.:R3 BORN: 3 BATH: 3 TOTAL - - - - -: 1663 sf VALUE..f: 119034 REAR • 35 PLUMBING - SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRrS.: 0 RAIN DRAIN ft: 0 TRAPS • 0 LAVATORIES....: 4 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 0 SF RAIN DRAINS: 1 CATCH BASINS..: 0 TUB /SHOWERS...: 2 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 100 BCKFLW PREVNTR: i GREASE TRAPS..: 1p OTHER FIXTURES: 0 — MECHANICAL - - -- FUEL TYPES FURN (100)( ..: 1 BOIL /CMP ( 3HP: 0 VENT FANS : 4 CLOTHES DRYERS: 1 /GAS / / / FURN ) =100K ..: 0 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1 MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES : 0 GAS OUTLETS...: 1 -- ELECTRICAL - - -- -- RESIDENTIAL UNIT - -- --- SERVICE /FEEDER - -- --TEMP SRVC /FEEDERS -- - -- BRANCH CIRCUITS - -- - - -- MISCELLANEOUS - - -- - -ADD'L INSPECTIONS- - 1000 SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FOR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 3 201 - 400 amp..: 0 201 - 480 amp..: @ 1st W/G SiC /FOR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0 LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0 MANF H.M /SVC /FDR: 0 601 - 1000 amp.: 0 601 +amps -1000 v: 0 MINOR LABEL -10: 0 1000+ amp /volt.: 0 --- -------- - - - - -- PLAN REVIEW SECTION — Reconnect only.: 0 ) =4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V "NOMINAL: CLS AREA/SPC OCC: ELECTRICAL - RESTRICTED ENERGY A. SF RESIDENTIAL B. COMMERCIAL - - - -- --- AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: OTH: :: X BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL: GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDICAL OTHR: HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL # SYSTEMS: 0 Owner: - - -- -- Contractor: -- -- - --- TOTAL FEES :$ 4056.06 WINDWOOD HOMES INC WINDWOOD HOMES 14076 SW BENCHVIEW TERRACE 14076 SW BENCHVIEW TERRACE TIGARD OR 97224 TIGARD OR 97224 Phone #: 590 -4700 Phone #: 590-4700 Reg #..: 050196 This permit is issued subject to the regulations contained in the Tigard Municipal Coae, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. --- - - - - -- REQUIRED INSPECTIONS --- Footing Insp PLM /Underfloor Framing Insp Gas Fireplace Water Service In Building Final Foundation Insp Mechanical Insp Shear Wall Insp Insulation Insp Appr /Sdwlk Insp Erosion Control Post /Beam Struct Plumb Top Out Low Voltage Gyo Board Insp Electrical Final Post /Beam Mechar Electrical Servi Fireplace Insp Rair. drain Insp cna: 1 Final Crawl Drain Electrical Rough Gas Line Insp Water Line Insp Plumb Fina Permit tee Signat, e .tee -- — / — Issued By '' i , .e,' / _ _ Call for inspection -- 639 -4175 • .... . 1 U g- Plan Check # ,ITY OF TIGARD Residential Building Permit Application Rec'd By .M44_ 3125 SW HALL BLVD. New Construction Additions or Alterations Date Recd / •; 6 IGARD, OR 97223 Single Family Detached or Attached _ Date to P.E. , .. , 303) 639 -4171 Date to DST - S - Print or Type Permit # / MT/ 7 Incomplete or illegible applications will not be accepted Called _ Name of Subdivision Lot # Name Job ff ll,LsEf1(L� Li�0 S S8 ' sca�.� -O Architect Mailing Address Address Site Address /Sc s Ps w .2 3 „f 1 4 c29(.=, 5L,.; LU.fr A C T City /State Zip Phone Name W sr Oc 0 N - S .t C (' w o on 5'� 22s Name Owner Mailing Address w A- t — 6Lz w (r f t -M9 Jw Svc c4∎Ji 1,./ CL- tAiE'c- 1 City/State Zip Phone Engineer En i Mailing Address r o {- T( C�/M- 0, oft 7-22_4 S - 40 .4 ( o 3 S L ! o a Zip F City/State Zip Phone Name • P6s4 lLtrr0 oil q - 21 b General 5A-1- C A - per; J2 Describe work new) addition 0 alteration 0 repair 0 Contractor Mailing Address to be done: � Additional Description of Work: City/State Zip Phone Oregon Const. Cont. Board Lic.# Exp. Date Attach Copy of ' OS (. t 6 . 31 2 -S3( >/ Project . , Current COT Business Tax or Metro # Exp. Date ✓ Valuation � ' ) 1 Licenses 46 -S r994 NEW CONSTRUCTION ONLY: Name Mechanical /4 VANcc1) H G Sq•J House: : Sq.Ft.G�� e: Sub- Mailing Address . . Contractor C. `t t ei SE 4 a � A-k) Corner Lot Yes No Flag Lot Yes No City/State Zip Phone (check one) V (check one) i.--- 1pc - Cv+.,1 t7t on. `t 4-2eA. 43-4 -01 Co I Restricted Audio /Stereo Burglar Oregon Const. Cont. Board Lic.# . Date Energy System Alarm Attach Copy of 00? Q s-?-3 s-?-3 4( Z.�19 ✓ Installation Garage Door HVAC Current COT Bus' ess Tax or Metro # Exp. Date Licenses a ' ),(D e 2-4 / y c 1/ Opener Systems Name (check all that Other: Plumbing '' S eL.LL0-1 d ,•v 6 apply) Sub Mailing Address Will the electrical subcontractor wire for all Yes No Contractor fDt. awc "7---/ 6a • restricted energy installations? C/ City/State Zip Phone • • Has the Subdivision Plat recorded? N/A Yes No ` r4L. - t1.A i 0 a 43 -0z3- Cog -1( o34 Oregon Const. Cont. Board Lic.# Exp. Date Reissue of MST# Solar Compliance { Attach Copy of 7 6 0 3/2 (1 9-7 (Calculation Attached) Current Plumbing Lic. # p. D to / I hereby acknowledge that I have read this application, that the Licenses _344-I Q6 e8 1 1.3 i ( ? ✓ information given is correct, that I am the owner or authorized agent of COT Business Tax or Metro # Exp. Date ✓ the owner, and that plans submitted are in compliance with Oregon 00°0 (G 85” (( -9. State laws. Name Signature of Owner /Agent Date Electrical ()'T. t+0 EL cTel- L c - N C. Contact Person Name Phone Sub- Mailing Address Contractor moo Sw 6tA-, FOR OFFICE USE ONLY: City/State Zip Phone Plat # Map/TL #: Po rt - I 4- - 22,3 639 - 583 3 ) C I o � ?� - 32 25(o y gG /MO Oregon Const. Cont. Y Board Lic.# Ex,a� - JJ Attach Copy of ll 3 � D i l l / J � � / a J � Setback Zone: Sol Current Electrical Li . # Exp. D to y/ n Licenses 311 - t(25 c ( OI o cr6 ! 1 J� COT Business Tax or Metro # Exp. Date / Engineering Approval: Planning Approval: TIF: _1sts\rnstapp.doc Ple 1 (1 1411(4- iF 7 P-- Permit # Account Description Amount Amt. Pd. Bal. Due - /NO ..0 MST. Permit (BUILD) 483 00 4l f 3 Plumb. Permit (PLUMB) ac,S.01 ..22 Mech. Permit (MECH) L) 3.5 0 4t3. cv ELC /ELR Permit ( ELPRMT) - a/ State Tax (TAX) difit -," Bldg: .. c/, 1 ,5' 4.02 Plumb: • /1 L Mech: . I ELC /ELR: 00 ,{ ( I . 2Ct q. a 5.--- Plan Check MST: 4/ 5 - 0 1 I , (BUPPLN) v{ 50115116 Plumb: ..S 50 (PLMPLN) Mech: (MECPLN) / v, rf /12 V' CDC Review (LANDUS) 1 /D — y 0 --- ,.54.q( -64 /. Sewer Connection (SWUSA) o ? a ' u - 0 v Sewer Inspection (SWINSP) 3 s 3 ■ Parks Dev Charge (PKSDC) /d 5 / OS 0 Residential TIF (TIF -R) /5 7 0 45 G Mass Transit TIF (TIF -MT) 1 2.0 /al 0 Water Quality (WQUAL) Water Quantity (WQUANT) / 0 0 / U 0 Erosion Control Permit (ERPRMT) 6 cf 6e( Erosion Planck/USA (ERPLAN) aD p pv ,i'v Erosion Planck/COT (EROSN) (2 4 9i 411 Fire Life Safety (FLS) TOTALS: 4 3 0(, , / fi(r41 i:ldstslmstapp.doc cp4- bag /. db Rev. 7/96 CITY OF TIGARD 13125 S.W. HALL BLVD. TIGARD, OR 97223 IMPORTANT PERMIT NOTICE MT HOOD ELECTRIC INC 8900 SW BURNHAM #F -7 TIGARD OR 97223 • Electrical Signature Form Permit # • MST96 -0407 Date Issued.: 09/24/96 Parcel - 2S104BC -HW058 Site Address: 14296 SW LUKAR CT Subdivision.: HILLSHIRE WOODS Block • Lot: 58 Zoning • R -7 PD Remarks: Path I Your company has been indicated as the electrical contractor for the permit indicated above. In order for the electrical permit to be valid, the signature of the supervising electrician is required. Please have the appropriate individual from your company sign below and return this Electrical Signature Form prior to the start of work. No electrical inspections will be authorized until this completed form is received. AN INK SIGNATURE IS REQUIRED ON THIS FORM OWNER: ELECTRICAL CONTRACTOR: WINDWOOD HOMES INC MT HOOD ELECTRIC INC 14076 SW BENCHVIEW TERRACE 8900 SW BURNHAM #F -7 TIGARD OR 97224 TIGARD OR 97223 Phone #: 590 -4700 Phone #: Reg #..: 113641 Sign. � r'71': Sue s nr iiv iiv g Electrician Please return this completed form to the address above. ATTN: Building Dept. If you have any questions, please call 639 -4171, ext. #310 CITY OF TIGARD 13125 S.W. HALL BLVD. TIGARD, OR 97223 IMPORTANT PERMIT NOTICE JIMS PLUMBING P 0 BOX 7160 ALOHA OR 97007 Plumbing Signature Form Permit # . MST96 -0407 Date Issued.: 09/24/96 Parcel • 2S104BC -HW058 Site Address: 14296 SW LUKAR CT Subdivision.: HILLSHIRE WOODS Block Lot: 58 Zoning R -7 PD Remarks: Path I Your company has been indicated as the plumbing contractor for the permit indicated above. In order for the plumbing permit to be valid, please have the appropriate individual from your company sign below and return this Plumbing Signature Form prior to the start of work. No plumbing inspections will be authorized until this completed form is received. AN INK SIGNATURE IS REQUIRED ON THIS FORM OWNER: PLUMBING CONTRACTOR: WINDWOOD HOMES INC DIMS PLUMBING 14076 SW BENCHVIEW TERRACE P 0 BOX 7160 TIGARD OR 97224 ALOHA OR 97007 Phone #: 590 -4700 Phone #: Reg #..: 71860 X E:t-k Signature of Authorized Plumber Please return this completed form to the address above. ATTN: Building Dept. If you have any questions, please call 639 -4171, ext. #310 • Pgge No. 1 CASE HISTORY FOR CASE NO.: MST96-0407 • WINDWOOD HOMES 14296 SW LUKAR CT 08/01/97 .Action Description Rea/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By - - -- --- -- ------ --- MSTA005 Application received / / / / 08/16/96 PASS JMH 08/26/96 JDA MSTA008 Permit Created / / / / 08/26/96 PASS JDA 08/26/96 JDA MSTA010 Check for prcl. restrict. / / / / 08/26/96 PASS JDA 08/26/96 JDA MSTA012 Plans routed to Plans Examiner / / / / 08/26/96 PASS JDA 08/26/96 JDA MSTA026 Plans approved by Plans Exmr / / / / 09/05/96 PASS RT 09/05/96 BT2 MSTA030 Reviewed plans routed to DSTS / / / / 09/05/96 PASS RT 09/05/96 BT2 MSTA080 (F) Ready to issue / / / / 09/07/96 APPR TAT 09/07/96 TAT MSTA092 (F) Issue combination permit / / / / 09/24/96 PASS DRA 09/24/96 DRA MSTA097 Issue plumbing signature form / / / / 09/24/96 PASS DRA 09/24/96 DRA MSTA098 Issue electric signature form / / / / 09/24/96 PASS DRA 09/24/96 DRA MSTA705 Footing Insp / / / / 10/14/96 APP GS 10/14/96 GES MSTA706 Foundation Insp / / / / 10/30/96 APP GS 10/31/96 GES MSTA710 Post /Beam Structural / / / / 11/08/96 APP GS 11/08/96 GES MSTA711 Post /Beam Mechanical / / / / 11/08/96 APP GS 11/08/96 GES MSTA713 Crawl Drain / / / / 12/27/96 APP GS 12/27/96 GES MSTA717 PLM /Underfloor / / / / 11/08/96 APP GS 11/13/96 GES MSTA720 Mechanical Insp / / / / 02/24/97 # -1- see framing notes this date _ DIS KS 02/25/97 KBS MSTA720 Mechanical Insp / / / / 02/18/97 gas pressure 0#'s; extend dryer vent FAIL RB 02/18/97 RB inward; insulate heat duct w /in soffit; . cover stud w /flame spread w /in fireplace cavity; exhaust vent disconnected - upstairs bath & make tighter seal at master bath. MSTA720 Mechanical Insp / / / / 02/27/97 pending - make tighter seal at master PASS RB 02/27/97 RB bath exhaust vent; insulate heat duct at garage soffit; MSTA720 Mechanical Insp / / / / 03/03/97 damaged wall duct stairs /kitchen PEND RB 03/03/97 RB do not drywall over this section. MSTA722 Plumb Top Out / / / / 01/09/97 trap arm exceeded developed length FAIL MS 01/10/97 MRS MSTA722 Plumb Top Out / / / / 01/13/97 PASS MS 01/14/97 MRS MSTA723 Electrical Service / / / / 01/23/97 sign label APP GS 01/23/97 GES MSTA724 Electrical Rough In / / / / 01/23/97 APP GS 01/23/97 GES MSTA724 Electrical Rough In / / / / 01/30/97 CALLED FOR COVER AND SERVICE [ALREADY DIS GS 01/30/97 GES DONE ] WET CONC FLOOR I COULDN'T SEE IF PANEL WAS SIGNED MSTA724 Electrical Rough In / / / / 02/25/97 APP GS 02/25/97 GES • Page No. 2 CASE HISTORY FOR CASE NO.: MST96-0407 WINDW00D HOMES 14296 SW LUKAR CT 08/01/97 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By -- -- - -- -- --- --- --- MSTA725 Framing Insp / / / / 02/24/97 # -1- strap glu /lam to plates at garage DIS KS 02/25/97 KBS # -2- insulate heat ducts at garage # -3- support micro /lam hip at garage # -4- fireblock soffit adjacent to furnace # -5- add support under lvl header hallway # -6- support rafters at rear bay # -7- provide clearance at fireplace #-8- strap notched plates at oval duct # -9- provide complete roof framing detail # -10- strap trimmers to garage header MSTA725 Framing Insp / / / / 02/27/97 pending- mech issues; cover studs w /in PASS RB 02/27/97 RB fireplace cavity w/ flame spread. • MSTA725 Framing Insp / / / / 03/03/97 Mech issue PEND RB 03/03/97 RB Also noted: plumbing is in the crawl access hole and needs to be protected; allow for 18 X 24 clearance w /in opening of access. MSTA726 Shear Wall Insp / / / / 01/09/97 nail floor sheathing above garage; nail FAIL RB 01/09/97 RB garage wings 2/8; HTT -22's missed at living room wings- nail sheathing 6/12; FTA's missed upstairs- sheathing req'mts w/4/12 nailing; exterior sheathing- nail 6 -inch o.c. if side wall of garage and fireplace chase. MSTA726 Shear Wall Insp / / / / 01/06/97 # -1- no approved plans on site DIS KS 01/06/97 KBS MSTA726 Shear Wall Insp / / / / 02/18/97 PASS RB 02/18/97 RB MSTA735 Gas Line Insp / / / / 02/24/97 #-1- 25 psi for 15 minutes APP KS 02/25/97 KBS MSTA735 Gas Line Insp / / / /' 02/18/97 0# FAIL RB 02/18/97 RB MSTA740 Insulation Insp / / / / 03/03/97 PASS RB 03/03/97 RB MSTA745 Gyp Board Insp / / / / 03/10/97 pending- missed nailing- marked! PASS RB 03/10/97 RB MSTA755 Rain drain Insp / / / / 12/27/96 APP GS 12/27/96 GES MSTA761 Water Service Insp / / / / 12/27/96 APP GS 12/27/96 GES MSTA765 Appr /Sdwlk Insp / / / / 05/01/97 SIDE 8 APPROACH FINAL PASS PI 05/01/97 KAS • Ode No. 3 CASE HISTORY FOR CASE NO.: MST96 -0407 • • • WINDW00D HOMES 14296 SW LUKAR CT 08/01/97 Action Description Reg/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done • Date By - - -- - -- - - - - ---- --- MSTA790 Electrical Final / / / / 04/30/97 secure grounding conductor for phone FAIL DD 05/01/97 RB lines & cable grounding service; grounding conductors req'd to go to separate grounding lugs in service; panel labeling; smoke detector not interconnected in bedrm upstairs. MSTA790 Electrical Final / / / / 05/01/97 PASS TLP 05/05/97 TLP MSTA795 Mechanical Final / / / / 05/01/97 see building final this date FAIL RB 05/01/97 RB MSTA795 Mechanical Final / / / / 05/02/97 PASS DD 05/02/97 RB MSTA797 Plumb Final / / / / 04/30/97 not ready FAIL MS 04/30/97 MRS MSTA797 Plumb Final / / / / 05/02/97 PASS MS 05/02/97 MRS MSTA799 Building Final / / / / 05/01/97 seal siding at meter location; FAIL RB 05/01/97 RB usa erosion approval; electrical final; _ fwd bedrm smoke detector not interconnected; handrail needs to be extended to nosing of tread at base of stairs; UNDER- FLOOR- support flex 4" off ground /4' intervals insulate bare metal of duct MSTA799 Building Final / / / / 05/02/97 electrical not approved FAIL DD 05/02/97 RB • exterior grading 4% slope 6" clearance from siding -to -earth MSTA799 Building Final 05/07/97 / / 05/06/97 PASS GL 05/07/97 JT MSTA960 (F) Issue Cert. of Occupancy / / / / 05/06/97 mailed 8 - - 97 08/01/97 S *W • • -v i CITY OF TIGARD BUILDING INSPECTION NOTICE I nspection Line: 639 -4175 Business Phone: 639 -4171 r' Footing Rain Drain Cover /Service FINAL: Foundation Water Line Ceiling - Plumb. Post/Beam Mech. Shear /Sheath Framing -Mech. PIbg.Und /FIr /Slab Plbg. Top Out Insulation - Elect. Post/Beam Struct. Mech. Rough -in Gyp. Bd. -Bldg San. Sewer Gas Line Appr /Sdwlk Reins. Other: Date: � A.M. P.M. Entry: Address: P /Z Tenant: Ste: MST: ! e a 46 7 Q , BUP: Con /Own: O l O I `O ' -Q � ] 5 MEC: PLC ELC: : THE FOLLOWIW CORRECTIONS ARE REQUIRED: ELR: Inspector: 6 ' `G 16 1 1. Date:5 7 L9P O D DISA`PPROVED /CALL FOR REINSP. CF CO