Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
CITY OF TIGARD MASTER PERMIT r PE: RM I T f#........ MST �q— �Z►�Z►c•_q % �i � �� �� ,� DEVELOPMENT SERVICES DATE ISSUED: 02/20/98 PARCEL: 2S111DA -01600 SITE ADDRESS...: 08670 SW LODI LN SUBDIVISION, ...: APPLEWOOD PARK NO. 1 ZONING: R -7 PD BLOCK.......... LOT .............:012 J•URISDICTIONI: TIG , Remarks: PATH 1: New single family dwelling w /attached garage. - - - -- BUILDIm ------------ _— _----- ______ -_----- - - - - -- - -- REISSUE: STORIES • 2 FLOOR AREAS ---- BASEMENT...: 0 sf REQUIRED SETBACKS - -- REQUIRED------- -- CLASS OF WORK. :NEW HEIGHT • 25 FIRST • 1037 sf GARAGE • 479 sf LEFT • 13 SMOKE DETECTRS: Y TYPE OF USE...:SF FLOOR LOAD....: 40 SECOND...: 1273 sf FRONT • 20 PARKING SPACES: 2 TYPE OF CONST.:SN DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT : 5 OCCUPANCY GRP.:R3 BDRM: 3 BATH: 3 TOTAL - - - -: 2310 sf VALUE..$: 163008 REAR • 15 -------- - - - - -- - -- --PLUMBING------------ SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 1 RAIN DRAIN ft: 100 TRAPS : 0 LAVATORIES • 4 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 1 SF RAIN DRAINS: 1 CATCH BASINS..: 0 TUB /SHOWERS...: 3 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 100 BCKFLW PREVNTR: 1 GREASE TRAPS..: 0 OTHER FIXTURES: 0 -------- - - - - -- - - -- -- - - - - -- MECHANICAL ----------------------------------------- -- FUEL TYPES-- --- - -- FURN ( 1YK ..: 0 BOIL /CMP ( 3HP: 0 VENT FANS • 4 CLOTHES DRYERS: 1 GAS FURN )= 1v4( ..: 1 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1 MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES : 0 GAS OUTLETS...: 1 - -- ------------- - - - - -- ELECTRICAL - - - - - -- -- --------------- - ----- - - - -- -- RESIDENTIAL UNIT --- - -- SERVICE /FEEDER -- - -TEMP SRVC /FEEDERS— - -- BRANCH CIRCUITS - -- - - -- MISCELLANEOUS -- - -ADD'L INSPECTIONS- - 1000 SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0 EA ADD'L 500SF.: 4 201 - 400 amp..: 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT:•0 PER HOUR • : 0 LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT : 0 MANF HM /SVC /FDR: 0 601 - 1000 amp.: 0 601 +amps -1000 v: 0 MINOR LABEL -10: 0 i!m + amp /volt.: 0 • -- --- -- PLAN REVIEW SECTION — - -- Reconnect only.: 0 )=4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC: - ---- -- — — - - - - - -- ELECTRICAL - RESTRICTED ENERGY -- - -- - - - - -- A. SF RESIDENTIAL ----- - - - - -- B. COMMERCIAL---------------------------------------- AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM : INTERCOM /PAGING: OUTDOOR LNDSC LT: BURGLAR ALARM..: OTH: :: X BOILER HVAC • LANDSCAPE /IRRIG: PROTECTIVE SIGNL: GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDICAL OTHR: .. HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL # SYSTEMS: 0 Owner: - -- Contractor: --- - ----- TOTAL FEES:$ 3050.95 LEGEND HOMES LEGEND HOMES CORP /MATRIX DEV. This permit is subject to the regulations contained in the 6900 SW HAINES STREET PLAZA II, SUITE #200 Tigard Municipal Code, State of Ore. Specialty Codes and all TIGARD OR 97223 6900 SW HAINES STREET other applicable laws. All work will be done in accordance TIGARD OR 97223 with approved plans. This permit will expire if work is Phone #: 620 -8080 Phone #: 620 -8080 not started within 180 days of issuance, or if the work is Reg #..: 000006 suspended for more than 180 days. ATTENTION: Oregon law - _----- - - - - -- - _ - - -__— ------ requires you to follow rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952- YY1- '�' You may obtain copies of these rules or direct questions to OUNC by calling (503)246 -1987. ----- ------.-------------------- REQUIRED INSPECTIONS ------- - - - - -- - --- --- -------- --- - -- Erosion Control Crawl Drain /Back Electrical Rough Gas Line Insp Water Line Insp Plumb Final Footing Insp PLM /Underfloor Framing Insp Gas Fireplace Water Service In Building Final Foundation Insp Mechanical Insp Shear Wall Insp Insulation Insp Appr /Sdwlk Insp Post /Beam Struct Plumb Top Out ow Voltage Gyp Board Insp Electrical Final Post /Beam Meehan Electrical Fireplace Insp Rain drain Insp Mechanical Final /'�� �j� Issued By : `� , Perm i t t e e Signature: il aYt t o V'y y ,� I/i- (/i'� " �/�( ±+- ++++±+-.74: -++++ r7 + ++++++-0- -F•-1-1 -I-- 1-4-1- 1- ±±±- F-I-°I ++ ++ +++ ++++- ++++I- +++++-1 +±+++++++ Call 639 -4175 by .00 p. m. for an inspection needed the next business day id Plan Check # � � • CITY OF TIGARD Residential Building Permit Application Recd By_ 13125 SW HALL BLVD. New Construction Additions or Alterations Date Recd CLC TIGARD, OR 97223 Single Family Detached or Attached (Duplex) Date to P.E. ,, —ii 9 V 503- 639 -4171 \ Date to DSTY " 1 L -�f Permit # 5r9 SS ooh F 503- 684 -7297 Called I Print or Type Incomplete or illegible applications will not be accepted i f req ` -co. 5 A vi / N''e of Project Lt/ ame Job >*le/. A1A ai' dress i�'YI.t'.6 Architect Maili Address Address Site Address (0900) l q 62 10 „,/(A LO ci l L �✓I City/State Zip Phone NaTe ,/ ,(� t � e /Lef C 97 3 (020 - Lep /, ri-i& S Nam I Owner Mailing Address r` D-? .0 A—c)A fQ () -4 11(ANY17`� if En Mailing Address i /State Zip Phone Coq & q / i J City/State Zip Phone General Nam g722 (4211 Contractor L.P ..Qr / Describe work ew Addition Alteration 0 Repair 0 Mailing(Address to be done: Prior to permit logo e) Additional Description of Work: issuance, a copy City/State Zip Phone • of all licenses 1Topo - n9. q'7 7 Z 62-C-) -- TS 0S are required if OregWi Const. Cont. Board Exp. Date PROJECT expired in COT Lic.# O 6-19°) VALUATION 3 7 , database GO 5 0)7) , Mechanical Name NEW CONSTRUCTION ONLY: Sub- ..3 3C q 3 Inc__ Sq. Ft. House: 3 ,. Sq. Ft. G ("/ Contractor Mailing Add r Prior to permit 2p2_ 5C I 0 5 -1.) Corner Lot YE NO Flag Lot YES NO issuance, a copy City /State Zip Phone (check one) (check one) of all licenses ?O1 11::tnci (SP, q7Z I Co 25 3 ' 7 Rl Restricted Audio /Stereo Burglar are required if Oregon Cons . Cont. Board Exp. Date Energy . Alarm expired in COT Lic.# - database q g % 3 1 S ,}c -- q � Installation Garage Door HVAC Plumbing Name Opener Systems Sub- a 1 u mks t r�� (check all that Other: Contractor Mailing Address 1" apply) Will the electrical subcontractor wire for all YE NO P0 O ( 2 CD restricted energy installations? Prior to permit City/State Zip Phone Has the Subdivision Plat recorded? N/A s NO issuance, a copy C1 r6, s nom, 4 7c' 3n CcG, L -ctc I ]� of all licenses are Oregon Const. Cont. Board Exp. Date required if Lic.# Reissue of MST #: Solar Compliance expired in COT 2 3 2P V 7 /0 L (Q -9 4 6 (Calculation Attached) database Plumbing Lic. # Exp. Date I hearby acknowledge that I have read this application, that the a x203 °6 - - information given is correct, that I am the owner or authorized Name agent of the owner, and that plans submitted are in compliance with Oregon State laws. Electrical C .Elear c _ Sig ture /Age Date L S Mailing Address1� -.%%// v� �� j. l Contractor 2 545 5 W I v t h t,.J C ers 6 n e ,N C -?C) / hone # City/State Zip Phe �a t C' Prior to permit c FOR OFFICE USE ONLY: O issuance, a copy A- \A CST, el 9;1 / J L32° Plat #: Map/TL #: of all licenses are Oregon Co Cont. Board Exp. Date /l3- 31, 3a ,, j //l 1 - 646° required if Lic.# Setbacks: Zone: Solar:,, /� i expired in COT i I CD721 p � j .- Icf -q� �-7 CPL)i -s I rd /�' database Electrical Lic. # Exp. Date - E y �3U5 Engineering Approval: Planning Approval: TIF: 1 /v-/ & r r -/ - Y I:SFREM.DOC (DST) 4/97 CITY OF TIGARD 13125 S.W. HALL BLVD. TIGARD, OR 97223 IMPORTANT PERMIT NOTICE WOLCOTT PLUMBING CONT. INC PO BOX 2007 GRESHAM OR 97030 Plumbing Signature Form Permit # • MST98- . 0028 Date Issued.: 02/20/98 Parcel • 2S111DA -01600 Site Address: ` 0 - 86 - 70 - SW 'LODI - LNG Subdivision.: APPLEWOOD PARK NO. 1 Block Lot: 012 Zoning R -7 PD Remarks: PATH 1: New single family dwelling w /attached garage. Your company has been indicated as the plumbing contractor for the permit indicated above. In order for the plumbing permit to be valid, please have the appropriate individual from your company sign below and return this Plumbing Signature Form prior to the start of work. No plumbing inspections will be authorized until this completed form is received. AN INK SIGNATURE IS REQUIRED ON THIS FORM OWNER: PLUMBING CONTRACTOR: LEGEND HOMES WOLCOTT PLUMBING CONT. INC 6900 SW HAINES STREET PO BOX 2007 TIGARD OR 97223 GRESHAM OR 97030 Phone #: 620 -8080 Phone #: Reg #..: 000238 X yl /4 Signature of Authorized Plumber • • Please return this completed form to the address above. ATTN: Building Dept. ' If you have any _questions, please call 639 -4171, ext. #310 CITY OF TIGARD 13125 S.W. HALL BLVD. TIGARD, OR 97223 IMPORTANT PERMIT NOTICE GARNER ELECTRIC 21787 SW TUALATIN VALLEY HWY SUITE L ALOHA OR 97006 -1248 Electrical Signature Form Permit # • MST98 -0028 Date Issued.: 02/20/98 Parcel • 2S111DA -01600 Site Address: 08670 SW LODI LN Subdivision.: APPLEWOOD PARK NO. 1 Block Lot: 012 Jurisdiction: TIG Zoning R -7 PD Remarks: PATH 1: New single family dwelling w /attached garage. Your company has been indicated as the electrical contractor for the permit indicated above. In order for the electrical permit to be valid, the signature of the supervising electrician is required. Please have the appropriate individual from your company sign below and return this Electrical Signature Form prior to the start of work to the address above, ATTN: Building Dept. No electrical inspections will be authorized until this completed form is received. AN INK SIGNATURE IS REQUIRED ON THIS FORM OWNER: ELECTRICAL CONTRACTOR: LEGEND HOMES GARNER ELECTRIC 6900 SW HAINES STREET 21787 SW TUALATIN VALLEY HWY TIGARD OR 97223 SUITE L ALOHA OR 97006 -1248 Phone *: Phone #: Re a 4 , # . : 001211 X • 0 Si -� . upervising Electrician Solar Balance Point Standard Worksheet Address 86 70 Sc, / /1 Box A calculations: North -South dimension for the lot. • Box A: This dimension is determined by finding the midpoint of the North lot line and drawing an intersecting line perpendicular to that point. First, determine which property line is the North lot line. The North lot line is the line with the smallest angle from a line drawn east -west and intersecting the northern most point of the lot. NORTHERN NORTHERN LOT UNE i LOT UNE ry North -South Dimension for Lot: Measure the distance from the midpoint of the North lot line to the South lot line along the described line. 7v feet <== NCR7H -SCU11-1 DIMENSION •,.■�' 4 ' �a Box B calculations: Shade point height for your residence. Box B: 1. Determine whether measurements will be based on the peak or eave of your Which describes structure. The orientation of the ridge is also important. your residence? la: if the roof line runs North- South, measurements wil (circle one) be based on the peak of the root. 0 0 0 W; UM UM "a'"'n=iti■ 1A 1B 1C 1 b: If the roof line runs East -West and the roof pitch is less than 5/12, measurements will be based on the eave. 5 SHADE POINT CAE lc: If the roof line runs East -West and the roof pitch is 5/12 or steeper, measurements will be based on the S n 12 Poor Arch p eak. ❑or steeperp SHALE PCWi RIDGE Box B. continued Box B: 2. Measure change in elevation from front property line to finished floor elevation. If the lot slopes up from the front lot line to the foundation, the figure is positive. If ft the lot slopes down from the front lot line to the foundation, the figure is negative. 3. Measure distance from finished floor elevation to the affected peak/eave. + Z ft 4. If the roof line runs North - South, deduct three feet. If the roof line runs East -West, - ft deduct nothing. 5. Subtract one foot for each foot of difference in elevation from the front property line to the rear property line, if the lot slopes up from the front to the rear. If the lot has no slope or slopes up from the rear to the front, deduct nothing. - / ft 6. Total figure for box B: 2 S S ft Box C. Distance to the shade reduction line. Box C: 1. Measure the distance from the North property line to the foundation near the / '' ft affected peak/eave. 2. Measure the distance from the foundation to the affected peak or eave. + / ' ' ft 3. Total figure for box C: 3 Z ft It is most useful to draw a vertical line to represent the appropriate figure found in box "A" and a horizontal line to represent the appropriate figure found in box "C'. The intersection of the vertical and horizontal lines determines the value found in box "D ". The value in box "D" should be compared to the value in box "B "; if the value in box "B" is less than or equal to the value found in box "D ", then the building is in compliance with the solar balance code. If you have any questions, please contact us at 639 -4171, x304 or at the Community Development Counter. MAXIMUM PERMITTED SHADE POINT HEIGHT (in Feet) I Distance to North -south lot dimension (in feet) shade 100+ 95 90 85 80 75 70 65 60 55 50 45 40 reduction line from northern lot line (in feet) 70 40 40 40 41 42 43 44 65 38 38 38 39 40 41 42 43 60 36 36 36 37 38 39 40 41 42 55 34 34 34 35 36 37 38 39 40 41 50 32 32 32 33 34 35 36 37 38 39 40 45 30 30 30 31 32 33 31 33 36 37 38 39 40 28 28 28 29 30 31 32 33 34 35 36 37 38 35 26 26 26 27 28 29 30 31 32 33 34 35 36 30 – 24 - -- 24 -- 2425 26 - 2 - 7— I x"3'°' - 3031 32' 33 34 25 22 22 22 23 24 25 2 27 28 29 30 31 32 20 20 20 20 21 22 23 214 25 26 27 28 29 30 15 18 18 18 19 20 21 212 23 24 25 26 27 28 10 16 16 16 17 18 19 2 21 22 23 24 25 26 5 14 14 14 15 16 17 118 19 20 21 22 23 24 Box D. Maximum allowed shade point height: L8 feet h: \does \nancy \ventu ra\solar.chp Revised 2/26/96 12/23/2004 Case Activity Listing 12:44:57PM TIDEMARK Case #: MST98 -00028 COMPUTER SYSTEMS, INC. r ., er ...r��N ,. 9!%5A71:2314,14001•734:=1:!:: .. >. .., >a- �x;,� q,�',; ;� .4 °fti%,'n '' � �; >,, , YY ✓, w, a1; %;;. ",, %� °. Vii, _ ±',1�',::air e e r9 �""9' CJ�, 36 gq ,� - . _ .., - �. . ,.�•� ��.n -�.. a � 9.. . F �, ,� , .. 1� s , ,.,,,, , , �' -a���� °nom. <�' .�.. ... � ., MSTA005 Application received 2/5/1998 None RECD JSD 2/11/1998 GEO MSTA008 Permit Created 2/11/1998 None DONE GEO 2/11/1998 GEO MSTA010 Check for prcl. 2/11/1998 None DONE GEO 2/11/1998 restrict. GEO MSTA012 Plans routed to Plans 2/11/1998 None PASS GEO 2/11/1998 Examiner GEO MSTA026 Plans approved by Pln 2/12/1998 None PASS RT 2/12/1998 Examiner BT2 MSTA030 Reviewed plans 2/12/1998 None PASS RT 2/12/1998 routed to DSTS BT2 MSTA032 DST Post Review 2/13/1998 None DONE B 2/13/1998 Completed BON MSTA705 Footing Insp 2/24/1998 None PASS TLP 2/24/1998 TLP MSTA706 Foundation Insp 2/26/1998 None PASS TLP 2/26/1998 J *H MSTA710 Post/Beam Structural 3/6/1998 None PASS TLP 3/9/1998 J *H MSTA711 Post/Beam 3/6/1998 None PASS TLP 3/9/1998 Mechanical J *H Page 1 of 4 CaseActivity..rpt Case Activity Listing 12/23/2004 12:44:59PM TIDEMARK Case #: MST98 -00028 COMPUTER SYSTEMS, INC. v ,viva „,,yam :, -t+ rrr'r.:�rd ; , N « .,.,;.M >,, -� I ,, .�..:.� �. ,r �� -„ ... - .: °;.. , �,� >„ v �.�f�,- �= "4 °6% %:.ir�,.; �.: Ica.. ;3, ;- .«t ��,,, y, ... ,•.. �l�15�1 ..lid v ti� ..r.:.:,. , .. , :.,.....,g...,r:.. -< a , refit ! ; . <_ i , i '': ,�. ti i # te;l, ,r ate a o his " � .,,, w�� ;,- ,,,;.�;,,- N�:r; .� ,��- ..,,.,�l�o.,,,�,,.�„ �fb,,,.:..,,..,�� ,.. - .,...A. ..�_. ,w�,���;,.._ .�.,�, a...., a .., ., r., ..� ��a ... - �.�'.:�y;. .,..ny11r..,..r,._..,, ., ;'nirr, MSTA713 Crawl 2/27/1998 None PASS TLP 3/1/1998 Drain/Backwater J *H valve MSTA717 PLM/Underfloor 3/5/1998 None FAIL TLP 3/5/1998 Not ready J *H MSTA720 Mechanical Insp 4/14/1998 None FAIL TLP 4/17/1998 No pressure on test gauge. Interior J *H duct work mechanical okay. Retest gas line. Crawl access completely blocked by ductwork. MSTA722 Plumb Top Out 4/1/1998 None PASS TLP 4/2/1998 J *H MSTA723 Electrical Service 6/10/1998 None PASS BRP 6/11/1998 J *H MSTA724 Electrical Rough In 6/10/1998 None PASS BRP 6/11/1998 J *H MSTA725 Framing Insp 4/14/1998 None PART TLP 4/14/1998 Crawl access completely blocked by J *H ductwork. MSTA726 Shear Wall Insp 4/1/1998 None PASS TLP 4/2/1998 J *H MSTA728 Low Voltage 6/10/1998 None PASS BRP 6/11/1998 J *H MSTA735 Gas Line Insp 4/14/1998 None FAIL TLP 4/16/1998 see mechanical this date JT MSTA740 Insulation Insp 4/17/1998 None PASS TLP 4/17/1998 J *H Page 2 of 4 CaseActivity..rpt Case Activity Listing 12/23/2004 12:44:59PM TIDEMARK Case #: MST98 -00028 COMPUTER SYSTEMS, INC. /lC;de •• •ego`" 35• , s.�•: /. "7/i�- ,'L.= �iS-�.; •:Pw: Ia4• x3P�x :��y ' ", i. /.ev i`ii4 .. /'rq /, �)'.� '% v %%:1��% ��m"�y,.c:r;3� e ;'!'P, �nO ^%ter. '��'+.. ,,, fi x:,.. \•.�., r, w rekotylii f` �ji i� # K t MSTA745 Gyp Board Insp 6/16/1998 None PASS TLP 6/17/1998 J *H MSTA755 Rain drain Insp 2/27/1998 None PASS TLP 3/1/1998 J *H MSTA760 Water Line Insp 6/16/1998 None PASS TLP 6/17/1998 J *H MSTA765 Appr /Sdwlk Insp 4/27/1998 None PASS PI 4/29/1998 DGW MSTA795 Mechanical Final 6/15/1998 None FAIL TLP 6/16/1998 SEE BLDG FINAL J *H MSTA797 Plumb Final 6/15/1998 None FAIL TLP 6/16/1998 SEE BLDG FINAL -Water line J *H inspection ? ? ?? MSTA080 (F) Ready to issue 2/13/1998 None PASS B 2/13/1998 BON MSTA092 (F) Issue combination 2/20/1998 None PASS JSD 2/20/1998 permit JSD MSTA095 Issue plumbing 3/2/1998 None RECD JMT 3/2/1998 signature form JT MSTA097 Issue electric 3/2/1998 None RECD JMT 3/2/1998 signature form JT MSTA717 PLM/Underfloor 3/6/1998 None PASS TLP 3/9/1998 J *H Page 3 of 4 CaseActivity..rpt Case Activity Listing 12/23/2004 ��� 12:44:57PM TIDEMARK Case #: MST98 -00028 COMPUTER SYSTEMS, INC. Q ,/ $',✓ ,- G%- /.k, 3 `�.�, gay :, // 9:_.«,.. %, s�„/, .,, .. ,lz.,.r � - , •e:..briw•jrF,�r. .e r '::i �,��,:, 9 r, � : ro .,,., - ....�,..: <�. u- ..,,..,:`� ats� � S1 �' a ..T1'OA =:�:, p >.;�;� � :- , yr� >;�`,,., r , : ' -y' 3 ' Vii �" �� " ✓ ,. �'Ek.. ,: �..= -f. < , ,;.',,, . >•- r k', ,- . ��.;,�::.. �:.., .acs; „'.,,... �n -;3 J�n `•.” ,�,,,. - s".,:,,f, ". B , sue.,- ,rr >„ T r- Y sk a I� c ho ` .. s > �Va, �F,A MSTA713 Crawl 3/6/1998 None PASS TLP 3/9/1998 Drain/Backwater J *H valve MSTA720 Mechanical Insp 4/17/1998 4/17/1998 None PASS TLP 4/17/1998 J *H MSTA735 Gas Line Insp 4/17/1998 4/17/1998 None PASS TLP 4/17/1998 J *H MSTA795 Mechanical Final 6/17/1998 6/16/1998 None PASS TLP 6/17/1998 J *H MSTA797 Plumb Final 6/17/1998 6/16/1998 None PASS TLP 6/17/1998 J *H MSTA799 Building Final 6/17/1998 6/16/1998 None PASS TLP 6/17/1998 J *H MSTA790 Electrical Final 6/10/1998 None PASS BRP 6/11/1998 LINE VOLTAGE 121, KITCHEN J *H GFCI 2 MA. & 3 MA. GFGI TRIP LOW - MAY EXPERIENCE NUISANCE TRIPS. TRIM& FINISH VERY GOOD. MSTA799 Building Final 6/15/1998 None FAIL TLP 6/16/1998 1. Ductwork in crawl space w /broken J *H straps and laying on ground. 2. Turn hot water heater so I can see plumbing fixtures for proper control of cold/hot water. MSTA970 Case Finaled 12/23/2004 None DONE JMT 12/23/2004 JMT Page 4 of 4 CaseActivity..rpt oq.3i a 915L- " A , CITY OF TIGARD BUILDING INSPECTION DIVISION 24 -Hour Inspection. Line: 639 -4175 Business Phone: 639 -4171 Date Requested: 6-/O-9? A.M. )( x P.M. MST: eb 'd 2s , Location: o 70 5a) ?ddL C . BUP: Tenant: Suite: Bldg: MEC: Contractor: Phone: 5 ?' 07 PLM: Owner: Phone: ELC: ELR: / . SIT: ` BUILDING BLDG (con't) 31525 '. MECHANICAL ELECTRICAL, SITE Site Post/Beam osr� Post/Beam a � _ � ' / �`=' �� n � Sewer /Storm Footing Roof UndFl/Slab Rough -In Ceiling Waterline Slab Framing Top Out Gas Line Rough -In UG Sprinkler Foundation Insulation Sewer Hood/Duct Reconnect Vault Bsmt Damp Drywall Storm Furnace Temp Service MISC. Masonry Ceiling Rain Drain A/C UG Slab Shear /Sheath Fire Spklr /Alm Crawl/Found Dr Heat Pump t �7olt� Approved • p 'roved Approved Approv • 4 Approved Appr /Sdwlk Not Approved :. v • d Not Approved zq►� on..)► . ved Not Approved sir/%' a ' -- t FINAL A `; t • . FINAL t AL FINAL -- / ri e. V /91lG -- /. )'II. 6: c1° ,.Z mg, el, 3 4, G= 7--,41.o L ©1.4/ °— hi o ° r / e. r) c' P n vi s'e h e- P 7's-1r r��- L)-ihi qh c /i )mac° r 0 4c2cj . 0 Call for reinspection `� / ne 0 Reinspection fee of $ required before next inspection 0 Unable to inspect Inspector: 1 "" 1 "</ e.:) � Date: G9 --/ — [ Page of sue. k