Loading...
Correspondence / IP .: , INDUSTRIES, INC. - MEMORANDUM • , TO: Bob Poskin RECEIVED City of Tigard SEp 0 FROM: Steve Johnson 3 199 VIP'S Industries, Inc. COMMUNITY DEVELOPMENT RE: Site Plan Review SIT #: 99 -00049 , Phoenix Inn Expansion Project . SITE PLAN REVIEW COMMENTS -JULY 29; 1999 DATE: September 3, 1999 Bob: �� ��:e ; +:, q <; e �. � . ° w ; q �•F" `SITE - WOR � <_ .., 1. Planning Staff (Mark Roberts) provided no instruction or requirement . regarding further planning processes required. I. would appreciate a little more direction from you as to exactly what your requirement is. If it is to simply consolidate the parcels currently in common ownership into one, we can simply execute a- deed from ourselves to ourselves accomplishing that. I need further direction from you please. . A,liquefaction statement from a certified geotechnical engineer has already been provided, and is assumed to be adequate: Accordingly, nothing further will be provided at this time. Please advise if you require more. . :fir 77%,„ - "` 3 ", ':v A -,11:%- . BIa E SSI LITY � -. - -ACC ��, ..... _�= .�: °'e _ r a . . Sheet #1 -see revised note with ODOT sign standard at detail' 1/1. • . - . Sheet #1- location of 2 ADA stalls has been revised to comply. Also, see detail 1/1. Sheet #1 -see five foot wide sidewalk added for compliance. '. , 6 29757 SW Boones Ferry Rd. • Wilsonville, Oregon 97070 Telephone 503 - 682 -9284 • FAX 503 - 682 -9257 4. Sheet #1-see additional notes. Wit Ell Per our telephone conversation the day before yesterday, fire hydrant and, fire department connection information referenced in comments #1-7 are not required to be submitted at this time, but must be on file before a building permit will be issued. Acknowledged and agreed. 8. Acknowledged and agreed. tclkte 1% 1. Per our telephone conversation, nothing further is necessary regarding Valuation information: Enclosed herein please find three copies of revised submittal documents. Since the only comments addressed in this Site Plan Review relate to Sheet #1 only, I will enclose 'three copies of cover sheet (Sheet 0) and Sheet #1, only. If you need anything further, please advise immediately. As before, in the interests of time and convenience, please direct any further questions/comments/requests directly to me at 682-9284. Thank you for your courtesies and cooperation throughout. Ver Truly Yours, lab Steven V. Johnson Enclosures: Architectural Drawings-Sheets 0 and 1 only , .. , . • , - p . . ,, IN DUSTRIES, INC. RECEIVED TO: Bob Poskin JUL 3 0 1999 FROM: . ' Steve Johnson Phoenix Inns COMMUNITY DEVELOPMENT Re: Soils Report /Liquefaction Statement July. 30, 1999 Bob: , Per my request please find Geotechnical Report, and, Liquefaction Statement from GeoDesign, Inc. for the above referenced project. . If you need anything else, please give me a call direct at 682 -9284. Thanks 411i , . . . . . . . . . , . . . , . . , . , . • . . , , .. . 29757 SW Boones Ferry Rd. •, Wilsonville, Oregon 97070 Telephone 503 - 682 -9284 • FAX 503 -682 -9257 • • GEODESIGN, INC. -'' GEOTECHNICAL, ENVIRONMENTAL, AND GEOLOGICAL CONSULTANTS . I 1 REPORT OF GEOTECHNICAL ENGINEERING SERVICES Phoenix Inn Expansion Tigard, Oregon GDI Project: VIP's -4 I 1 1 ' For VIP Industries, Inc. 17400 SW Upper Boones Ferry Rd., Suite 230 • Portland, Oregon 97224 • Phone (503) 968 -8787 • Fax (503) 968 -3068 1 For a 3,500 psf design bearing pressure, total settlement of footings is anticipated to be less than 1 -inch. Most of this settlement will occur during construction of the building. Differential settlements should not exceed 1 -inch. Lateral Capacity We recommend using a passive pressure of 300 pcf for design purposes for footings confined by structural fill. In order to develop these capacities, concrete must be poured neat ' in excavations, the adjacent confining structural fill must be level and that static groundwater must remain below the base of the footing throughout the year. Adjacent floor slabs, pavements or the upper 12 -inch depth of adjacent, unpaved areas should not be considered when calculating passive resistance. A coefficient of friction equal to 0.32 may be used when calculating resistance to sliding. FLOOR SLABS Satisfactory subgrade support for building floor slabs supporting up to 300 psf areal loading ' can be obtained from the native silt or from structural fill, when prepared in accordance with the recommendations presented in the "Site Preparation" section of this report. A minimum 6- inch -thick layer of floor slab base rock should be placed over the prepared subgrade to assist as a capillary break. A subgrade modulus of 250 pounds per cubic inch can be used for the design of the floor slab. Floor slabs constructed as recommended will likely settle less than '/z -inch. Vapor barriers are often required by flooring manufacturers to protect flooring and flooring adhesives. Many flooring manufacturers will warrant their product only if a vapor barrier is PI installed according to their recommendations. Selection and design of an appropriate vapor barrier, if needed, should be based on discussions among members of the design team. We can provide additional information to assist you with your decision. Floor Slab Base Floor slab base rock should consist of crushed rock that is fairly well- graded between coarse and fine, contains no organic matter or other deleterious materials, has a maximum y particle size of 1'h inches, and has less than 5 percent passing the U.S. Standard No. 200 Sieve. The floor slab base rock should be placed in one lift and compacted to not less than 92 percent of maximum dry density, as determined by ASTM D 1557. GROUNDWATER CONSIDERATIONS Underslab Drains To reduce the possibility of uplift pressures on the floor slab from groundwater infiltration, we ' recommend that a subfloor drainage system consisting of perforated PVC pipe at 20 -foot centers be installed beneath the floor slab. The drains should consist of 4- inch - diameter perforated drainpipe wrapped in a non -woven geotextile filter. The geotextile should have an ' apparent opening size (AOS) between the U.S. Standard No. 100 Sieve and the U.S. Standard No. 4 Sieve, and a water permittivity of greater than 1.5 sec'. The drainpipe should be located in minimum 12 -inch deep trenches, be embedded in a zone of drain rock, and be ' sloped to drain to a suitable discharge. The drain rock should be uniformly graded, have a GeoDesign, Inc. 6 Vip's- 4:072399 When used as structural fill, the on -site silty material should be placed in lifts with a maximum uncompacted thickness of 6 to 8 inches. The silt should be compacted to not less than 92 percent of the maximum dry density, as determined by American Society for Testing and Materials (ASTM) D 1557. Imported Granular Material If imported granular material is used as structural fill, this material should consist of pit or quarry run rock, crushed rock, or crushed gravel and sand that is fairly well- graded between coarse and fine, contains no organic matter or other deleterious materials, has a maximum particle size of 3 inches, and has less than 5 percent passing the U.S. Standard No. 200 Sieve. The percentage of fines can be increased to 12 percent of the material passing the U.S. Standard No. 200 Sieve if placed during dry weather. Imported granular material should be moisture conditioned to the approximate optimum moisture content for compaction, placed in 12- inch -thick lifts, and compacted to not less than 95 percent of maximum dry density as determined by ASTM D 1557. TEMPORARY SLOPES AND SHORING Based on soil conditions, temporary slopes for excavation of the basement of 0.75H:1V (horizontal to vertical) may be used to vertical heights of 16 feet or less where seepage is not encountered. If seepage is encountered, then flatter slopes and drainage will be necessary. It may be necessary to flatten the slopes to protect the surface from raveling. All cut slopes should be protected from erosion by covering them with plastic sheeting during construction. CONSTRUCTION DEWATERING Based on groundwater levels that we measured at the site, we anticipate that dewatering may be accomplished using sumps and pumps inside the excavation. Open excavation techniques may be used to excavate the basement, provided the walls of the excavation are cut at a slope of 0.75H:1V and groundwater seepage is not present. Sloughing may occur if the excavation extends below the groundwater table. The walls of the trench should be flattened or braced for stability if seepage is encountered. SHALLOW FOUNDATIONS We recommend that spread footings be embedded at least 18 inches below the basement floor slab. Continuous wall footings should have a minimum width of 18 inches, and be founded a minimum of 18 inches below the basement floor slab. Bearing Pressure and Settlement ' Footings founded as recommended should be proportioned for a maximum allowable soil bearing pressure of 3,500 pounds per square foot (psf). This bearing pressure is a net bearing pressure and applies to the total of dead and long -term live loads and may be —' increased by 1/3 when considering earthquake or wind loads. The weight of the footing and overlying backfill can be ignored in calculating footing loads. 1 GeoDesign, Inc. 5 Vip's- 4:072399 RETAINING STRUCTURES For walls not restrained from rotation, we recommend using- an equivalent fluid pressure of 35 pcf for design. We recommend using an equivalent fluid pressure of 52 pcf for design of. walls restrained from rotation. When computing resistance to lateral loads, we recommend using a base friction coefficient of 0.32. Footings for the retaining walls should be designed for a maximum bearing pressure of 3,500 psf, in accordance with the recommendations given for shallow spread footings. Wall drains should include perforated drainpipe wrapped in a non-woven geotextile filter installed behind the walls at the base. Backfill walls with imported granular material, as described in the "Structural Fill" section of this report. The above design recommendations are based on the assumptions that: (1) the walls consist of conventional cantilevered retaining walls or embedded building walls, (2) the walls are less than 10 feet in height, (3) the backfill is level and drained and consists of imported granular materials, and (4) no surcharges are imposed behind the wall. Reevaluation of our recommendations will be required if the retaining wall design criteria for the project vary from these assumptions. PAVEMENTS AC Pavements We have calculated pavement sections using American Association of State Highway Transportation Officials design methods, a design life of 20 years, and a resilient modulus of 7,500. We have assumed that traffic at the site will consist mostly of passenger cars and up to about five trucks per day. A pavement section of 2.5 inches of AC over 6.0 inches of aggregate base can be used in paved areas that will be exposed to the traffic described above. Aggregate base should be placed in one lift and compacted to not less than 95 percent of the maximum dry density, as determined by ASTM D 1557. The design of the recommended pavement section is based on the assumption that construction will be completed during an extended period of dry weather. Wet weather construction could require an increased thickness of aggregate base to support paving equipment without damaging the subgrade. We recommend that a non -woven geotextile be placed between the subgrade and the baserock to prevent migration of the silt into the rock. The geotextile should have a minimum Mullen burst strength of 250 pounds per square inch and a AOS between a U.S. Standard No. 70 and No. 100 Sieve. All thicknesses given are intended to be the minimum acceptable. AC should conform to Section 00745 of the Standard Specifications for Highway -' Construction, Oregon State Highway Division, 1991 Edition, for light -duty AC and aggregate base should conform to Section 02630 of the same specifications. GeoDesign, Inc. 8 Vip's- 4:072399 \CIS/ , f 7 oN.I__ ask \ . " JJ ,1 ' July 29 , 1999 CITY OF TIGA Charles Nagel & Associates OREG 11580 SW 67th Tigard, OR 97223 RE: Phoenix Inn Expansion Site Plan Review 9575 SW Locust PC #: 7 -36c SIT #: 99 -00049 Submittal documents for the above referenced project have been reviewed for conformance with the applicable 1998 Oregon Specialty Codes and other applicable codes and standards. The following comments are noted: {. .. <{ ., , - Sri'- •..,.,'.F;,+t, MF�..t.:t( •4+F - :?F +;:t1 ^-, •.- �f41 l: ' 3FS?, a,.. � \:- :;:.;.:::r.F�r;"�n:"i-: ;:�: h>?. , !x5�a� : :rr S: x,» ......,. ,. Fx. ��.L $i .rs�{ ^1 •h °"_�, , .. 6;cisa.t ..:� „�^s.,.�.. ...sr as a,rryr�,r sn :� ;ri : : : :. :: � - }y1 3 . :,r?..,e'Ea. €.�:? ,n{:� :.is,<.• } .•'£ti ro F ,S t' i ;t�. . I�TIIA'<� .� v . 6 _: }. «. ,. .. �. �,., �q., ;' ., .... ` ._..n „r.•�.: f.<:: q&;t':. h, i:.K..K`..,.::; = ..1 "".J: >f'n}S: :'7�.}%4 Fi!::.!tieZG° n•' {'.1: .... > .....:... . , :nun. »<r., „n: �^:.. � - :.:..Y., rva•,�a. �f- :.a.n= ;r', :- ,,...._.ra :..; :.r:{ :: P k'; c,. �#,» a��( r: N, r:! ara: x-:: f; rtr :�m.:.t...;�r=; ::...srt,...1._ !i:; ? „ ii:': : :� :< �u .... , 1. The proposed project site consists of more than one parcel of land. There shall be no underlying land divisions unless the buildings are designed for location to property lines. Provide a true copy of the recorded document describing the site as one parcel. 2. Provide a liquefaction potential and soil strength loss report (OSSC, Section 1804.1.1 and 1804.5). ,ar l.:s„m. :S� :x :: ,•.v,...:vt..- :id.<.u_ .�'3:i ::E ?= .,:.:ii; "si�:�. :i� :.;. - ... .,, 3• �n, fi.., .. :.,,,,,,,,,,,,,; °. ::.., ».,... ,._. ....,, - .,�',... _._.. Sri'` . >.. :.., >... #ea..r_.wn >r•+�,s §�ie,: s,a„t,n' «: "• •,._• .S4F,ivSi"e S cwa % k�i:�a , ta „u a..- rsu,an. +shF �a<i; :Fi :at �; ...s:. .,., , Vt,t »N.bJie.r= ipfs.n Y. t;LN ,.,... ._ .... .... ... ... .., ., , • r 1. Revised plans shall show details of the accessible signage, including the van accessible sign, and parking in accordance with Oregon Department of Transportation minimum standards (OSSC, Section 1104.1). SE_ 2. The 2 new ADA stalls must comply with OSSC, Chapter 11, Figure 9, provide e S�t*y details. S ��vis '� y 4 2V J SE!D 1 S P LL 3. You have not provided a continuous accessible route as defined by OSSC, S\QR.- 1 Section 1102. Door #1 does not lead to a public way. Secondly, check in occurs from the existing motel. The accessible route must also comply between the two buildings. Provide details. S 1rE. ! - I – vl ? W (D. \IVAC.,, St 1 .44. Width. All walks on accessible routes shall be continuous with a minimum clear width complying with Section 1109.4.1 (OSSC Section 1103.2.4.1). N .��%u= •.*ztietix'ay. .n. s, ..,.. r `a: p` :i :lFt.,,;�t;.':t;i, :,'<t•acF °i34'�. ' :”- 3�+ -=� :; c- us<i; �k�' i.�€;, :i __ 3 y 1. COMMERCIAL BUILDINGS - MINIMUM NUMBER OF FIRE HYDRANTS: The minimum number of fire hydrants for a building shall be based on the required 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 - 2772 Phoenix Inn Expansion Site Plan Review PC#: 7 -36c BUP #: 99 -00049 Page #2 fire flow prior to giving any credits for fire protection systems. There shall not be less than one (1) fire hydrant for the first 1,500 gallons per minute (GPM) required fire flow and one (1) additional fire hydrant for each 1,500 GPM or portion thereof over 1,500 GPM. Fire hydrants shall be evenly spaced around the building and their locations shall be approved by the building official. (UFC Sec. 903.4.2.1) 2. COMMERCIAL BUILDINGS - REQUIRED FIRE FLOW: The required fire flow for the building shall be 3000 gallons per minute (GPM) at 20 psi. Hydrants shall be flow tested in accordance with NFPA 291. Results shall be submitted to the City of Tigard, Attn: Plans Examiner, 13125 SW Hall Blvd., Tigard, OR 97223, on the form enclosed. 3. COMMERCIAL BUILDINGS - FIRE HYDRANTS: No portion of the exterior of a commercial building shall be located more than 250 feet from a fire hydrant when measured in an approved manner around the outside of the building and along an approved fire apparatus access roadway. (UFC Sec. 903.4.2.1) 4. FIRE HYDRANT /FIRE DEPARTMENT CONNECTION: A fire hydrant shall be located within 70 feet of a fire department connection (FDC). Fire hydrants and FDC's shall be located on the same side of the fire apparatus access roadway. (UFC Sec. 903.4.2.5) FDC locations shall be approved by the building official. (1996 Oregon Structural Specialty Code, Sec. 904.1.1) 5. FIRE DEPARTMENT CONNECTIONS ON BUILDINGS: Fire department connections shall not be located on the building that is being protected. (UFC Sec 903.4.2.5) 6. UFC (TVFR) Appendix III.F — A building survey and plans shall be provided to the fire department. Forward the attached survey when completed to include a site plan and one set of architectural drawings to: Plans Examiner, City of Tigard, 13125 SW Hall Blvd., Tigard, OR 97223. 7. No building shall be constructed, altered, enlarged, moved or repaired in a manner that by reason of size, type of construction, number of stories, occupancy or any combination thereof, creates a need for a fire flow in excess of 3,000 gallons per minute at 20 psi residual or exceeds the available fire flow at the site of the structure [UFC, Section 903.3]. A. Provide Fire Flow Testing pursuant to NFPA 291 using the enclosed "Hydrant Flow Test Report Form." B. Complete the enclosed "Fire Flow Work Sheet" and return to the City of Tigard, attention Plans Examiner. Note: These documents shall be on file before a building permit will be issued. • ` : Phoenix Inn Expansion Site Plan Review PC #: 7 -36c BU P #: 99 -00049 " Page #3 g 8. The installation of piping from the city vault, and the backflow device shall be installed by a licensed plumber. Installation, inspection and test shall be in accordance with NFPA 13. ` b 15a. Pe Th)& WAY t� .��„.-�;� :'��;?�a °is': :` i"", iY�;, �p�;„.:« „i:�;a;�,�!%�i?;z•„>",`,',c�„-: -•�,� -;{a ^;irri - �i '4G *., '' _ a>�S:J r.. �C .�,iST:4'An::3.p. .., � . 7t. ;M � ( '�>3;. ^ -! _ _ S �i3'i� r f �., ;�,�` §.: � i;�4; era:: ,4va..,.,�.. -' - �` >w•A�� ,4 . �1 . W1 ,.s �.” - .i7ix€s'.';:..•s. .7.,,. >r:r.. 00.44.0: ' :::;i.., ��� �'�3�i6§.- ,_.aeaia:, -�_ -, �#_� .i3� > -�e,m „;:�� >�an•..,. ,.. �,.�m..� �- - 1 Provide a notarized copy of the owner accepted bid. Please submit three copies of revised submittal documents and a letter indicating your response to the above comments -for review. Please call me at (503) 639 -4171 if you have any questions. . Sincerely, o rt Poskin, CBO SE OR PLANS EXAMINER lbldgSpnnsys109949. doc 4 lA (4 July 29,.1999 art OF TIGAR Charles Hagel & Associates OREGON 11580 SW 67th Tigard, OR 97223 RE: Phoenix Inn Expansion Site Plan Review 9575 SW Locust PC #: 7 -36c SIT #: 99 -00049 Submittal documents for the above referenced project have been reviewed for conformance with the applicable 1998 Oregon Specialty Codes and other applicable codes and standards. The following comments are noted: - - � SITE WOIKm�4 l � f ,,. ,\_. �..;e . i r-r: ,, .. .._ ;.. �.,r..,,, .. ... �,.�.,; .�a.., �' .{� , > Kmi ° >�ar r ,.. ��c�''�`';��, 1. The proposed project site Asts of more than one parcel (, land. There shall be no underlying land divk is unless the buildings are desi,...ed for location.to property lines. Provide a true copy of the recorded document describing the site as one parcel. Provide a liquefaction potential and soil strength loss report (OSSC, Section 1804.1.1 and 171.5). \ 4CCSSIBILITYr' " 'i,, ._ n,7 4• Ft .. �m- 6 e.--- Revised plans shall show details of the accessible signage, including the van accessible sign, and parking i g p g n accordance with Oregon Department of Transportation minimum standards (OSSC, Section 1104.1). 1 5K.-- / � The 2 new ADA stalls must comply with OSSC, Chapter 11, Figure 9, provide details. 3. You have not provided a. continuous accessible route as defined by OSSC, 0 Section 1102. Door #1 does not lead to a public way. Secondly, check in occurs from the existing motel. The accessible route must also comply between the two O buildings. Provide details. 0 Width. All walks on accessible routes shall be continuous with a minimum clear width complying with Section 1109.4.1 (OSSC, Section 1103.2.4.1). a,+`:s.,ti -.H:, ', M� ' , M ",: i" gw+:¢ y...9..:... - -. v5 itsm W.&: _ . _ _ .a' , f, sev', a -e 1 / COMMERCIAL BUILDINGS = MINIMUM NUMBER OF FIRE HYDRANTS: The minimum number of fire hydrants for a building shall be based on the required 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Phoenix Inn Expansion Site Plan Review PC #: 7 -36c BUP #: 99 -00049 Page #2 fire flow prior to giving any credits for fire protection systems. There shall not be less than one (1) fire hydrant for the first 1,500 gallons per minute (GPM) required fire flow and one (1) additional fire hydrant for each 1,500 GPM or portion thereof over 1,500 GPM. Fire hydrants shall be evenly spaced around the building and their locations shall be approved by the building official. (UFC Sec. 903.4.2.1) 2. COMMERCIAL BUILDINGS - REQUIRED FIRE FLOW: The required fire flow for the building shall be 3000 gallons per minute (GPM) at 20 psi. Hydrants shall be flow tested in accordance with NFPA 291. Results shall be submitted to the City of Tigard, Attn: Plans Examiner, 13125 SW Hall Blvd., Tigard, OR 97223, on the form enclosed. 3. COMMERCIAL BUILDINGS - FIRE HYDRANTS: No portion of the exterior of a commercial building shall be located more than 250 feet from a fire hydrant when measured in an approved manner around the outside of the building and along an approved fire apparatus access roadway. (UFC Sec. 903.4.2.1) 4. FIRE HYDRANT /FIRE DEPARTMENT CONNECTION: A fire hydrant shall be located within 70 feet of a fire department connection (FDC). Fire hydrants and FDC's shall be located on the same side of the fire apparatus access roadway. (UFC Sec. 903.4.2.5) FDC locations shall be approved by the building official. (1996 Oregon Structural Specialty Code, Sec. 904.1.1) 5. FIRE DEPARTMENT CONNECTIONS ON BUILDINGS: Fire department. connections shall not be located on the building that is being protected. (UFC Sec 903.4.2.5) 6. UFC (TVFR) Appendix III.F — A building survey and plans shall be provided to the fire department. Forward the attached survey when completed to include a site plan and one set of architectural drawings to: Plans Examiner, City of Tigard, 13125 SW Hall Blvd., Tigard, OR 97223. 7. No building shall be constructed, altered, enlarged, moved or repaired in a manner that by reason of size, type of construction, number of stories, occupancy or any combination thereof, creates a need for a fire flow in excess of 3,000 gallons per minute at 20 psi_ residual or exceeds the available fire flow at the site of the structure [UFC, Section 903.3]. A. Provide Fire Flow Testing pursuant to NFPA 291 using the enclosed "Hydrant Flow Test Report Form." B. Complete the enclosed "Fire Flow Work Sheet" and return to the City of Tigard, attention Plans Examiner. Note: These documents shall be on file before a building permit will be issued. Phoenix Inn Expansion Site Plan Review PC #: 7 -36c BUP #: 99- 00049' Page #3 8. The installation of piping from the city vault, and the backflow device shall be installed by a licensed plumber. Installation, inspection and test shall be in accordance with NFPA 13. Provide a notarized copy of the owner accepted bid. Please submit three copies of revised submittal documents and a letter indicating your response to the above comments -for review. Please call me at (503) 639 -4171 if you have any questions. Sincerely, Ro rt Poskin, CBO SE OR PLANS EXAMINER iAbldglpnnsyslsit9949 doc i 'P 45 -UNIT ADDITION r 5 (rI l 9 PHOENIX INN MOTEL L' SW LO T� 6 �� 1 TIGARD, OREGON STORM WATER DRAINAGE CALCULATIONS The attached calculations were prepared March 30, 1999 by: Timothy R. Turner, P.E. TRT Engineering, Inc. 2636 SE Market Portland, Oregon 97214 (503) 235 -7592 — fax (503) 235 -7593 The proposed drainage system consists of roof drains, parking lot catch basin inlets, and underground detention storage. Discharge will be to an existing stormsewer manhole located in SW Locust Street. Design features are depicted on the site plans (by TRT Engineering, Inc.) submitted by to City of Tigard Public Works by the motel owner, VIP's Industries, Inc. The detention system was designed consistent with Unified Sewerage Agency (USA) technical guidelines. On -site pipe sizes and slopes were calculated per the guidelines of the State of Oregon UPC Specialty Code. 4` 14,494 REGrJN 3j3 ri .evf. 6136(°° calccoverph.doc