Specifications I RECE IVED CU 15 1007 CIT x tai 1 iuARD BUILDING DIVISION ( Q007 00 53? Submittals For: METZGER 10350 SW LINCOLN STREET PORTLAND OREGON 97223 Submitted By: T & L Communications, Inc. P.O. Box 87387 Vancouver, WA 98661 360 - 737 -9725 360 - 737 -9648 fax ticomm @wa- net.com 37 -428 CLE Oregon Contractor 67787 CCB Number 6981 Metro Number 684 LEA Supervising Journeyman Larry E. Bushaw r , , METZGER P LENGEND EOL END OF LINE 110 WP H/S OUTDOOR HORNSTROBE 110 V H/S HORNSTROBE V S STROBE ILENT KNIGHT 5820 SILENT KNIGHT 5820 BY OTHERS 0 SMOKE DETECTOR F PULL STATION SK BELL EXPANDER 549 AIM ADRESSABLE MODUEL METZGER PORTABLES F F AIM SLC A IM AIM AIM AI SLC F F TO EXSISTING HORNS 110 30 30 30 30 SILENT KNIGHT 5499 SK HS g HS HS g HS 5820 12V7 AMP 12W AMP EXSITING PANEL BY OTHERS 120 Volt AC 20 AMP Circuit Gbbal ProlectVatuest ` SII,F.N'I� Project Name :JMETZGER PORTABLES Standby Hours:1 24 1 KNIGIII' Project ID:113746-07 1 Alarm Mins: 5 [ Prepared By: T & L Communications, Inc. Derating Factor:[ 1. 1 5820XL Calculations Date: [ 10/9/2007 Voltage Drop Warning Threshold %:[ 10 Panel ID: 15820XL Model: 5820XL Addressable Fire Alarm Control Max NAC Current: 3.0 Amps Location: [ELECTRIC ROOM I Volts: 24 VDC Max Panel Current: 5.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ o Ckt.# Circuit Name Qty /oDrop 'Standby Alarm & Type 1000 Ft. ` One -Way - Ohms EOL 5820XL 5820XL Main Control 1 0.140 0.260 SLC -DEV Addrsbl SLC Devices 4 0.000 0.000 5815XL SLC Loop Expander 0.000 0.000 5860 LCD Remote Annunc 0.000 0.000 5824 Serial /Parallel Module 0.000 0.000 5895XL ! Power Expander 0.000 0.000 5865 -4 LED Annunciator (4G) 0.000 0.000 5865 -3 LED Annunciator (3G) 0.000 0.000 5880 LED Driver Module - 0.000 0.000 SD505 -6SB Sounder Base s 0.000 0.000 SD505 -6RB Relay Base 0.000 0.000 SD -Duct Duct Hsg w /Relay 0.000 0.000 5883 Relay Module 0.000 0.000 PGM -1/0 #1 Notification Appl Circuit 0.000 0.021 #14 Solid 2.52 0.00 24.00 0.00% PGM -I/0 #2 Notification Appl Circuit 0.000 0.042 #14 Solid 2.52 0.00 24.00 0.00% PGM -1 /O #3 Notification Appl Circuit 0.000 0.067 #14 Solid 2.52 0.00 24.00 0.00% PGM -1 /O #4 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 24.00 0.00% PGM -I/0 #5 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 24.00 0.00% PGM - I/0 #6 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 24.00 0.00% Total Standby Current (Amps) 0.140 0.391 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 3.365 0.033 Total Alarm AH Required Total Combined AH Required 3.40 Command Shortcuts Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required >4.08, Configure Circuits Print Page 5820XL on the Web • t 1 it SILENT i ! ,- METZGER PORTABLES a KNIGHT � 24 `��" �� � r� 13746 -07 �t �1�ae�xA �i � 5 T & L Communications, Inc. + , 5499 Power Expander Calculations • {f � [�.mxa .. .� �.° " ....... _._..,,..,::. u. ,.u.;..u....:;.:..:..,,..•..a.. ..,. �., �. .�- ...�..:.n...e.:,....L..w.�.r _ aa,.�.. � _ _ ° . um»....,.,. _ . L._.,.,._ u.. � - :_.� ::K,... ,._ � "'a..°""° '" or 3= TELCO RM 2FLOOR �� I p,i ;r �� ; �� ����� -a! P ' y� e v a a r' os' � � ° �� a �t I ' _ at �Y..F1��.....,..�,.� 4tw _ ' �'� _...._..�._- ; S � � j 0.000 0.601 #14 Solid 500 6.31% 0.000 0.000 #14 Solid 0.00% 0.000 0.000 #14 Solid - "q 0.00% 0.000 0.000 #14 Solid 0.00% 5499 1 Aux Power Out 0.000 0.000 #14 Solid a `�4 '� is uc " Wire resistances are based upon an ambient temperature of 72 degrees F. Because of the minimal difference between solid and stranded wire no differential was made. s '�attkls.,L4�' • • 1 tiI1.I " " ` "' Circuit Configuration • Project Information Project Name: METZGER PORTABLES Project ID: 13746-07 Prepared By: T & L Communications, Inc. Date: 10/9/2007 Ckt. Number: 1 Panel ID: 5499(1) Ckt, Name: 5499(1) Circuit 1 Max Circuit Current: 3 Amps Current Draw Each Current Draw Total . Qty s, i. ^ Device Standby Alarm Standby Alarm 1 SYSTEM SENSOR 110 HORNSTROBE 0.000 0: 0.000 0.209 4 SYSTEM SENSOR 30 HORNSTROBE 0.000 0.098 0.000 0.392 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.601 Ckt NumbW2 lf � ` t ' � 4 f t Panel ID: 5499(1) ''''''''I: ". Ckt. Name. 5499(1} 6i ?cr� 2 f t �� Max Circuit Current' 3 Amps Qty Device Current Draw Each Current Draw Total Standby - Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused - 0.000 0.000 0.000 0.000 Unused 0:000. 0.000 0.000 0.000 0.000 0,000 Totals 0.000 0.000 ` r Ckt. Number: 3 Panel ID: 5499(1) Ckt. Name: 5499(1) Circuit 3 Max Circuit Current 3 Amps 1 - �� { - Qty Device Current Draw Each Current Draw Total `` Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000'' Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 _ 0.000 0.000 Unused _ 0.000 0.000 0.000 0.000 x000( : _: 0.000 Totals 0.000 0.000 Ckt.' Numberr $ * VO Panel ID: 5499(1)1 ;` -;!; k Ckt. Name: 5499(1) Circuit 4 Max Circuit Current: 3 Amps . � £ w , C 3 e I � . Current Draw Each Current Draw Total � }. ma - -� Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 . Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 : _ Unused 0.000 0.000 0.000 0.000 I 0.000 0.000 Totals 0.000 0.000 INTELLIKNIGHT FIRE ALARM CONTROL PANEL � . IntelliKnight® Model 5820XL " Addressable Fire Alarm Control System Y }5 4 o £. F _ 2 z a The IntelliKnight System is the easy a z way to make the most of fire alarm technology. s 07 IntelliKnight is the first fire alarm system to provide you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built -in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1- 800 - 446 -6444, or in Minnesota, call 612 - 493 -6435. Description programming via PC. The IntelliKnight 5820XL performs • Built -in digital communicator. drift compensation and calibration • Built -in Form C trouble relay checks on each of the sensors in rated at 2.5 amps at 24 VDC. the system. • Two built -in Form C The basic IntelliKnight 5820XL programmable relays rated at 2.5 system can be expanded by adding amps at 24 VDC. : modules such as the Model 5860 • Uses standard wire —no shielded Remote Annunciator, Model or twisted pair required. . "- 1 t 5815XL Signalling Line Circuit • Supports Sounder Bases. - p Expander the Model 5824 e Serial /Parallel Interface (for printing Primary VRMS at 50 / 60 f y 4 system reports), and the 5895XL Intelligent Power Module. The hz, 2.5A Model 5820XL also features a Total Accessory Load: 5A at 24 powerful built -in dual line fire VDC = . communicator that allows for 5 amps at 24 VDC of power - limited reporting of all system activity to a notification power location. Weight: 28 lbs. (12.8 kg) remote monitoring Standby Current: 140 mA Color: Red Features Alarm Current: 260 mA Telephone Requirements: • Up to 381 addressable points. Flexput Circuits FCC Part 15 and Part 68 approved • Supports Class B (Style 4) and Six ro rammable circuits which T Class A (Style 6) configuration p 9 Type of Jack: RJ31X (two required) for SLC, SBUS, and Flexput can be programmed individually as: provalst circuits. Notification circuits: 3 amps of UL Listing • Distributed, intelligent power. power- limited power per circuit at NFPA 72 - Central Station • Drift compensation. 24 VDC. - Remote Signalling • Flexput I/O circuits. Auxiliary power circuits: 3 amps -Local Protective • Eight pre - programmed output of power - limited power per circuit at Signalling System cadences, (including ANSI - 3.41), 24 VDC' - Auxiliary Protected and 4 programmable outputs. Initiation Circuits: 100 mA of Premises Unit • Built -in annunciator with 80- power limited power per circuits at CFSM: 7165 -0559: 130 character LCD display. 24 VDC. • RS 485 bus provides communi- Mechanical Specifications: SILENT cation to system accessories. Dimensions: 16 "W x 26.4 "H x ` KNIGHT • Built -in RS -232 interface for 4.65 "D (40.6 x 67 x 11.8 cm) v ii,„.,,..4 INTELLIKNIGHT FIRE ALARM CONTROL PANEL . . . IntelliKnight Mode1,5820XL Addressable Fire Alarm Control Pane! itlWilKiiitht:.5820 -- Acktitsabte:R*14000 . Syetem 1031•••• . PI* • S 1<4,,,V2,4' • ...• C- ... -: ... ... ,..., ,.....'. .=.- ' -. 11007-: • , 'ION -i!**64.3,44T ■ •:,;;-.' • ' itimolchlm .t. tricnuti-:. .- • - • .. _ 7," • IC elilitiv • . .. . s _ . ,7•••••wh•-, • • . • •• - •:•:4„ ,,,,,, - ..7 -- "--..---','", - - s : - . • , - „ • ' ,..., , „ .. . ,_ • • . •.. .........• ,,- - agrta..1-1: . :-'• .- - t : xi; .1.14 F.+Orrt.vnviiir , ,1.7•4 -:: ' z . -= oppor g 1 . ... - 4 i •%0,... -..1 J. .. . I 1 . I • ..-. , -.I. , ......:. : ... , - . . . . • ,., .„--,.4„-...-_,,, .... ',... N, 404,-- .....,• ;:,,s,....-.tz , • it , i ,, - . . . _ lir • . . . . . . . . . ,; 1 .G7.• , •.:- .=, t - ....:. ri .-4' • ..... . -------,...4.4„- • •• • • 00.4.0 1 „ .*-..4,400,00*-.44- :.. .. 44 4 4 .-„.„... „..... ........ • teas* ; &net Milillt l**** . . :-. - ... - i •; - .1i- I :Siii•• •: :* • - .-.• . Alfiblikki. .... i . 4,416 . . . . . 1 '47"",,,1•,.•., ' • ' - •-<,,,' 2, '•• 42 -1.1 - =' - -- - • • •• -4104 % 111 .g M# : - .. '.!`:: •••:••-- ISO • "' WI tr F:• .:. 44;411/ . . . . I •••• It ' r. ..,.. : ,:. ".-- •.:.; ''6;--'-'6' 4 i I - 1 .-.. --•,--'-,-.:- .... -- -- - oc. .. .. • 164 .r : ik,401., ...,.: .1 1:1.0.-- • . .. 1 :1,;....1,...... . • ..- . - --- • - - _.._ 1 I 042Ft trviattigr4at • Rotecknigt magma sottop4mi tioice•Aitm 4§1)14o74 =r"q' 'itrIZEI: .44 "1= +=Tr, 7.ttte-'.1 I . ••-"" • -- ...I :-..--: -÷- .•''. ''''' - - - - - Ittii *0 4 Al t....-1.1 =a...aft*. • avai.it•weee. . 1. MO WOW, ,. ; : - - • - _ - ' - :•-• • July 7, 2000 ON-1109 • E -200 • NOTI Fl E R FIRE SYSTEMS PS Series Batteries Section: Power Supplies GENERAL Power -Sonic PS Series batteries provide secondary power for the whole series of NOTIFIER fire alarm control panels. u FEATURES • Provide secondary power for control panels. LISTED • Gelled electrolyte. MH14328 (S) • Sealed and maintenance -free. • Overcharge protected. • Extended shelf life. • Easy handling with leakproof construction. • Ruggedly constructed, high - impact case (ABS, polystyrene, or polypropylene depending on model). • Long service life. • Compact design. CAPACITY Battery capacity, expressed in ampere -hours (AH), is the product of a discharge current and the length of time that the current is dis- charged. Batteries are rated according to their performance during 20 hours of discharge at a constant current. The rated capacity of a battery is determined by subjecting it to a constant discharge current for 20 hours at 68 °F (20 °C). After 20 hours the voltage across the terminals is measured. The discharge current which causes a reading of 1.72 volts per cell (5.16 V on a 6 SEALED RECHARGEABLE V battery and 10.32 Von a 12 V battery) is called the rated current. BATTERY This current multiplied by 20 Is the rated capacity of the battery. APPLICATIONS /°YWAIPp Mod•1 p8 -195 6 Volt 9.5 AK Use the PS Series batteries to provide backup power for control Po•r -Sonic Corporation panels. Select batteries based on current requirements for your system and the capacity of its charger. These batteries can be used over a temperature range of -76 °F to +140 °F (-60 °C to +60 °C). CONSTRUCTION The sealed construction of the Power -Sonic battery allows trouble - free, safe operation in any position. There is no need to add elec- s trolyte, as gases generated during overcharge are recombined in a unique "Oxygen Cycle." The battery is sealed, leakproof, and main- tenance -free. The case is of high - impact materials with high resis- tance to chemicals and flammability. The PS-695 Battery INSTALLATION All panels have space reserved for batteries. See the appropriate panel installation manual for battery size restrictions. Typical inter- connection diagrams are shown in the literature accompanying each control panel. This document Is not Intended to be used for installation purposes. We try to keep our product Information up to and accurate. We cannot cover all specific applications or O 9001 anticipate all requirements All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484 -7161 FAX: (203) 484 -7118 C E R Y a F u E 0 N OTI FI E R One Fire - Lite Place, Northford, Connecticut 06472 Bt6D&BING I MANIFACT1tlNC DN -1109 •07/07/00 — Page 1 of 3 ( HEIGHT 1 BELOW g . ................... .. °........ °. °.°....°...- °.e... ..°..°°. aaaa.° a°. a °aa°a.a°aa.a°a.a.a.....aaa.a°.. TOP VIEW 3 ± 0.08 Inches (94 ± 2 mm) e HEIGHT 2 BELOW E 3.86 ± 0.08 inches • (96 ± 2 mm) If- n n . a..... aa...a............a.°..... °..a. I T n n SEALED RECHARGEABLE BATTERY 1 BB -17: Optional Battery Backbox A 14 -1/2" W x 8 -1/4" H x 4 -3/4" D SIDE 2 (mm: 368.3 W x 209.55 H x 120.65 D) MODEL PS -1270 VIEW For remote mounting of two 12 -volt PS -12180 batteries. 12 VOLT 7.0 AMP. HOUR -- 5.94 i 0.04 inches (151 ± 1 mm) 2.56 ± 0.04 inches (65 t 1 mm) 1 1100dim 1,W - - - -- - - - BB-55: Optional Battery Backbox _ See CHG -120 data sheet for details. ENGINEERING SPECIFICATIONS The fire control panel shall be equipped with secondary power provided by gelled - electrolyte batteries. The batteries shall be maintenance-free and shall be capable of powering the system in a manner and for a length of time determined by the governing regulations and the authority having jurisdiction. Nominal Discharge DIMENSIONS Capacity Current Height over Nominal @ @ Width Depth Height terminal Weight Voltage 20 hr. rate 20 hr. rate - MODEL V A.H. mA in. mm. in. mm. In. mm. In. mm. lbs. kg. PS -695 6 9.5 475 4.26 108 2.75 70 5.54 141 5.54 141 4.9 2.2 P8-1250 12 5.0 250 3.54 90 2.76 70 4.02 102 421 107 4.1 1.9 PS -1270 12 7.0 325 5.94 151 2.56 65 3.70 94 3.86 98 5.7 2.6 PS -12120 12 12 600 5.94 151 3.86 98 3.70 94 3.86 98 8.8 4.0 P8-12180 12 18 875 7.13 181 2.99 76 6.57 167 6.57 167 12.8 5.8 PS -12250 12 25 1300 6.89 175 6.54 166 4.92 125 4.92 125 18.7 8.5 PS -12550 12 55 3000 10.25 260 6.60 168 8.20 208 9.45 240 39.7 18.0 PS- 121000 12 100 5000 12.00 305 6.60 168 8.20 208 9.45 240 65.7 29.8 110911.L4 Characteristic Discharge Curves 120% Effect of Temperature on Capacity 8.5 -13 ----- _ -��. 100% ' • 0. C 2 8.0 -12 ��„ o 80% IllE �- 0.25C 5 -5 -11 ' -� -0.6C `` Ce 5.0 -10 1 ` ; 0.1isc o.sc -' 60% �� / _ . -1 C � 0.25C A -2 C m 4. - 9 `0ec U 40% 11E/1% 1 / 4.0 -8 20% gp-■ I" 30 2C -- 1 C -0 1 2 3 5 10 20 30 60 2 3 5 10 20 30 0% • 11C td I minutes I hours -I -20' -10' 0' 10' 20' 30' 40' 50' 60' Discharge Time Q 20 °C (68 °F) 11o9¢rzwia Temperature (Degrees C.) Page 2 of 3 - DN -1109 • 07/07/00 PS-121000 RECHARGEABLE BATTERY: APPLICATIONS AND CHARGING CYCLE APPLICATIONS: Limit initial current to 20A Charge until battery voltage (undercharge) reaches 14.40 to 14.70 volts at 68 °F (20 °C). Hold at 14.40 to 14.70 volts until current drops to approximately 1000 mA. Battery is fully charged under these conditions, and charger should either be disconnected or switched to hoar voltage. "FLOAT" OR "STAND -BY" SERVICE: Hold battery across constant voltage source or 13.50 to 13.80 volts continu- ously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged position. NOTE: Due to the self- discharge characteristics of this type of battery, it is imperative that the battery be charged after six to nine months of storage, otherwise permanent loss of capacity might result from sulfation. 100% \�_ ____ - "' Charging is NOT 90% necessary unless ` � O , �__ � 100% of capacity 80% is required. 0 70% \HEN 5 5°C Charging before re c o c (41°F) ) ) use is necessary 60% „�'` to help fiver Et 50% alitri. A Charge may (� 40 °C 30°C fail to restore ■ (104 °F) (86°F) 20 ° 20°C I DO O ry 40% ° _ ) (� (68°F) I let batteries € 11 reach this state. s 0 % � 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) Aillh■ PS- 121000 14.OV III 1 i lii i Shelf -Life Ambient Temperature 20 °C (68 °F) 13.0 v and Storage e 12.0 V - - -- `�'��;E`�� \�._ MI! 111111111 •... > 11.0 V it o.�v a Jp'�— 20A ~ s.o v _rig 50A F inal 100A PS- 121000 a v Voltage Discharge I 2ooA Characteristics 1.2 2.4 6 12 24 36481 2 4 6 8 10 20 40 MINUTES X HOURS Discharge Time DN- 1109.07/07/00 — Page 3 of 3 FIRE SYSTEM ACCESSORY o 4 Firepower 5499 Distributed Power Module !_ - 1F i we The NAC expander that packs quite a combination - , punch, a whopping nine amps and built -in t ` synchronization for appliances . - The Firepower 5499 Distributed Power Module by Silent Knight is the most - ,_a `` powerful and cost- effective power supply available today. It delivers 9 amps of notification appliance circuit power and built -in synchronization for appliances from System Sensor®,Gentex®, and Faraday — what you need to drive power -hungry components like ADA notification appliances. The 5499's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5499 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost - effective notification power supply available, you need the Firepower 5499. Call Silent Knight today for more information at 1- 800 - 446 -6444. Firepower 5499 • Ground fault detector /indicator supervision between the 5499 and the Distributed Power Module • Independent trouble relay fire control panel. Polarized audible The firepower 5499 is a 9 amp • AC loss delay option shuts off power and/or visual notification devices are notification power expander that to non - essential high - current then connected to the 5499 signal provides its own AC power connection, accessories like magnetic door circuits using the 4.716 end -of -line battery charging circuit, and backup holders resistors provided. Since the 5499 battery for use with fire and security • Built -in synchronization for draws very little power from the control, controls that have 9-32 VDC outputs, appliances from System it is possible to connect one Firepower such as the Silent Knight Model 5208 5499 to each notification circuit on the Fire Control /Communicator. The 5499 Sensor®,Gentex ®, and Faraday control panel and still provide full is the cost- effective solution for • Stand alone operation. supervision of the notification circuits all the way back to the control panel. powering notification appliances • Lightweight design adds to ease of required by the Americans with installation and reduces shipping Disabilities Act (ADA). The 5499 has costs built -in ANSI cadence pattern, which • Operates with most polarized, UL can upgrade older control panels that Listed notification devices lack cadence capability. • UL 864 & 1481 listed - Features • • UL Listed for 9 amps of notification CSFM approved power • ANSI Cadence pattern output • Power supply's advanced switch capability built -in mode design reduces damaging Connection to Local Fire Control heat and manages power up to 50% f: more efficiently than other systems Firepower 5499 may be connected to a • Dip switches allow for easy local fire control which utilizes Class A reconfiguration or Class B type notification circuits operating between 9 and 32 VDC. The • 24 VDC filtered output voltage control panel's notification circuit is • Four power - limited notification connected to one of the inputs on the outputs; 2 Class A (Style Z) or 4 5499. The control panel's notification i Class B (Style Y), circuit end-of -line resistor is also or 1 Class A and 2 Class B connected across two terminals on the • Additional continuous auxiliary Firepower 5499, which provides 5r ;',V output SILENT - 3 amps per output circuit Firepower 5499 • 2 inputs; 2 Class B (Style B) ElleKNIGHT Distributed Power Module or 2 Class A (Style D) • FIRE SYSTEM ACCESSORY Firepower 5499 ;` ::. ;r .;`ar.° Distributed Power Module l',. "'d kL Supervision Auxiliary Ambient Firepower 5499 supervises a variety of power circuit: 1 Temp.: 32° to 120° F functions including: Notification 0° to 49° C • Low AC power. circuits: 4 Humidity 85% non- condencing • Low battery condition. Output max. • Earth ground fault. configuration: 2 Class A (Style Z) Mechanical • Auxiliary output power limit 4 Class B (Style Y) Dimensions: 12.25° W x 16 H x condition. (1 Class A & 3° D (30.88 cm W • EOL supervision trouble or power 2 Class B) x 40.64 cm H x limited condition at an output. Amps per 7.62 D cm) When a trouble condition occurs, output circuit: 3.0 (9.0 amps total) Indicator Lights Firepower 5499 creates a trouble Notification AC power on : Green condition on the host control signal circuit output: 20.4 to 27.3 VDC circuits to which it is connected. Battery trouble: Yellow Firepower 5499 still maintains the 4. 3.0 amps each, 4.7 kS2 EOL Ground fault: Yellow ability to be activated by the host resistor required Aux Trouble: Yellow control. In addition, the 5499 provides a on each Class B Outp Form C trouble relay output as anci circuit troubles (1-4): Yellow alternative to using the notification circuit trouble. No. of inputs 2 Approvals: Electrical Specification Input UL: 864 & 1481 configuration: 2 Class B (Style Y) or NFPA: 72 AC Input: 120 VAC at 3.6A 2 Class A (Style Z) Output: 24 VDC at 9 A Input Current voltage range: 9 - 32 VDC Standby 75 mA Battery charging Alarm 175 mA capacity: 33.0 AH Model 5499 Bieck. Diagram n ail *ow it�uit ado* F X811 5i0nat Gttcuttthi t7t$t t .. tl4 120 WC_ ksa_ P.reve t Avis" le thltput t.a t Fite # ; firitticerrAivir io rvir .atlon tirctri t m* ., i - it SILENT io KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800 -446 -6444 or in Minnesota 763 - 493 -6435 FORM# 350396, Rev. 02/01 FAX: 763 - 493 -6475 World Wide Web: http: / /www.silentknight.com Copyright ®2001 Silent Knight ' ..-. . - F .. „ i- r .c� k s F .fi c, ,� r r3 Vii "t -= -- 3 x t _o-z n - u ` c _ �, r� K r A L.LtlltNlGl ,•; u - z- - ....�_.'" }...,a,. r K ��', t.-:`, �s . . �i,- � _3 srs.�.�'�k? a. kt +� t -. - \+� r - ' T A N _ K ;7 ' i , : Addressable ionization y r .1 •K, 2 - - • . . a :. =4 4 Type Smoke Detector ' •• f . _ ' . *.: ...::re '. -- ��•� � An tntelliKni o ght addressable ionization smoke detectors ,. -. - =.T combine early warring with pin -point location ID combination that saves lives and property. Hospitals, industrial environments and other locations where rapid fire development is expected of their IntelliKnight detection package. Ionizations smoke detectors prvide early warning in fast flaming fires hat show little visible smoke. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds ate not wasted in detertnihing 1e of an al-arin. p The SD505 -AIS automatically compensates for contamination in the environment. Checking detector calibration is simple —even from a remote site. Like other IntelliKnight detector models, the SD505 -AIS offers for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, profile , odel SD505--6AA, allowing compl - application and ptacementflexibility. Combine all this with 'the you Model come to expect from Silent Knight smoke detectors —easy installation, stable operation, RF /transient protection, and vandal- resistant locking —and -it adds tip o a flexible solution to p t your fire protection needs. y sosos.jus inside the detector. After reaching the critical level, the detector tri Addressable Ionization T alarm. 99ers into at, f i : . The SD505 - AIS includes a status LED "� .. The 5D505 - Ais has responsive, yet which blinks a - • every high operational stability for an seconds, indicating that the head is j - extremely wide range of uses. The communicating with the loop. The .s SD505 -AIS can be used in areas status LED lights continuously during where early warning of trouble from an alarm. super- heated or flaming combustibles is is expected. . • The detector features automatic Radioactive Source: AM -241 .098pCi • compensation for contamination, and a Operating Voltage: 24 VDC `!$ simple detector calibration test procedure that can be run from he Current Consump • Low profile, 2.25 inches, panel, or remotely (using the S�ndby: :55 rnA including base WindowTM based downloading Alarm: .55 mA • Simple and reliable software). Ambient Temperature: 32 °F to 400 °F without mechanical swift hes Operation (0°C to 50°C) • Automatic compensation for Mounting: 4• SQR, eoc sensor contamination The SD505 -AIS ionization smoke Single gang mud detector has two chambers: a sampling ring • • Built - fire test feature chamber, and a reference chamber. Relative Humidity: 8S % Simple detector the Smoke or invisible combustion gases noncondensing testing through the control panel, can freelypenetretethe sampling or remotely through a chamber, but the reference chamber is Sensativity: 0.5;9% - 1.15 %° FT virtually closed to prevent easy entry. h 300 - 4000 FPM WindowsT based computer. Air Velocity. (Windows software required With both chambers ionized by a single radioactive source, a very small current for remote testing.) flows. • Vandal resistant locking feature Presence of visible smoke or invisible • Meld cleanable gases greatly influences the current • UL listed, meets NFPA 72 Ch 7 • flow in the sampling chamber, changing CSFM approved the voltage ratio between the two chambers. This difference is amplified • MEA approved P . SILENT GI-TT ...::..- trr'�+r�" -+ CY K... s ue , 1. ro - - Y ,. . - F f re, t. 4 —r • ° - t y >- • rittodel SD5054AIS 5 - .,:- ; i - f - - ' - Addressable 1efi2jfe®n Type Smoke Detector moke The d°a or Silent 11 f wish and install where indicated at the plans, dual- chamber, addressable ionization s sfed elm Knight SD5O5 -AIS. The corns fion detector head, and twist -lock base, shall be ULe file with Silent Knight's tntenlKnight 582OXL fire panel. The base shall pern>;t nrrect interchange with Sent Knight t SD505 A Photoelectric Smoke Detector, oc appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the Ong LED will latch on steady. The detector may be reset by actuating the control panel reset switch. need for external test apparatus. shall capable of being selected and measured by the control panel without the The vandal - resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD5O5 shall automatically, pew a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. =s ts/ts' Diameter = 3- 15/16" \wig* ........„.._...00:„„ ..,,,,, ......., 0 © e p Height = 2.25 inches, Dia/ net,, 1 Cc ( 7---- ;;�'; Z including base Ei 0 libiti Z564/41 efron 41 yr &so tibia SQa$ Detector Mod KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 $00 444 r in Minnesota 612- 493-6435 RM# 3 2 AMERICA • FAX 612-493-6475 FORM 350227, Rev. 01/00 World Wide Web: http://www_sHentknight_com Copyright 02000 Silent Knight INTELLIKNIGHT ACCESSORY:' SD500 -PS Addressable Pull- Station t i tli - — i- 3 .- *� intelliKnight's addressable pull stations combine Lx _ f ast response with pin -point location 1D. ,----,, _ r= _ -, _ - . The SD500 -PS is an addressable manual fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SD500 -PS provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving preaous seconds in deteirhining the ibcatlett of an alarm. The SD500 -PS mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine oil - this' with the Teatures you've tame to exp2Ct - from Silb it 1 Knkjfit - Sasy irtstatietith - arid Stable operation - and it adds up to a flexible solution for all your fire protection needs. Model SDS41041 Operation Wrenn& Pill Station The SD500 -PS single action pull The SD500 -PS is a single action stations are operated by a pull on ,t► PULL addressable fire pull station the front pull cover of the station. r---- featuring rugged metal A plunger switch, wired to a self }'"`: construction. A terminal strip on contained addressable module, is �_ r , back of the pull station allows to initiate the alarm. Once released as the pull station opensz `'=- r interconnection of the -pull station to the SLC of an IntelliKnight control operated, the cover hangs down panel. The SD500 -PS is designed and can be seen up to 100 feet for indoor use in non - explosive away The pull station is reset by environments. The normally open returning the front cover to the initiating point contacts are gold- normal upright position and plated to avoid risk of corrosion. relocking the station with a reset The SD500; -PS has been tested -by key. The reset keys are the same UL for compliance to the keys used on Silent Knight requirements of the Americans with enclosures. d Disabilities ACT (ADA). The SD500 -PS includes a status Fadvres LED which blinks, indicating that the addreetebre rnodtile it , „ii - UL Listed communicating with the loop. The '" " `" r • CSFM listed status LED lights continuously • ADA compliant during an alarm. A dip switch on - Key reset (Same key as Silent the addressable module is used to Knight enclosures) set the unique address. • Surface mount back box Spodbanions available Operating Voltage: 24VDC • Terminals - accept up to 14 Standby Current: 55mA gauge wire Alarm Current: .55mA • Extremel. eaS t0 Ambient Temperature: 32 °F to 120 °F y y operate (0 °C to 49 °C) • Corrosion- resistant gold - plated Mounting: Single gang contacts. box - SILENT Optional fled Surface Mount - SMB B • Reflective label makes it easier " IQVIGH, to locate in low light INTE.LIKNIGHT ACCESSORY - • SD500 ®PS Addressable Pull - Station . } Manual pull station shall be addressable Module SD500- PS.Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be dearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable MIM module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings . Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. f 4 . . l } 1,� l ti ( I 1 , ' f ■ x _ �'. 1 . Y . a\ Y irk r.� - 1 1 4 ` �... } Wiring t - -.._. _-r . ,� jirD i S Mounting Mountin ' to Single Gang g • to Optional Surface "` _ Electrical Box Mount Box 1 1 , t 1 Dimensions '" SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800- 446 -6444 or in Minnesota 612 - 493 -6435 FORM# 350342, Rev. 1/2000 FAX: 612 -493 -6475 World Wide Web: http : / /www.silentknight.com Copyright ©2000 Silent Knight INTELLIKNIGHTACCESSQRY Addressable Heat Detector 4 - Y 3 J j f IntelliKnight® addressable heat detectors combine • accurate heat detection with pin -point location ID. An essential combination for any installation. IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Like other IntelliKnight detector models, the SD505 -AHS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight detectors —easy installation, stable operation, RF /transient protection, and vandal- resistant locking —and it adds up to a flexible solution for all your fire protection needs. Model SDSOS.AHS If the temperature exceeds the trip _ Addressable Heat Detedor point (programmed at the panel), k • an alarm occurs. The status LED The SD505 -AHS is a heat detector lights continuously during the alarm (` i F suited to virtually any commercial period. setting. The SD505 -AHS is an absolute temperature device. This Under normal conditions, the status F. means that it responds in alarm if LED blinks approximately every 15 seconds, indicating that "t'- X �'' the temperature goes above the g at the head is trip point (programmed at the communicating with the loop. panel). Features The SD505 -AHS provides accurate • Low profile, 2 inches, including SD505 - AHS Heat Detector temperature measurement data to base Specifications the fire alarm control panel. This Absolute temperature device Operating Voltage: 17 to 41 VDC heat detector is particularly suited to environments where smoke • Simple and reliable addressing Current Consumption: detectors cannot be used because • Uses digital communication Standby: .55 mA of the presence of steam or protocol Alarm: 55 mA cooking fumes, such as in a • The SD505 -AHS is UL Listed Detection Temperature kitchen. and meets the requirements Range: to 1 (57°C 65°C) Operation outlined in NFPA 72 Inspection Ambient Temperature: 3 2°) to 100°F Testing and Maintenance, p The SD505 -AHS unit is made up of Chapter 7. (o C to 37 C) an externally mounted thermistor Mounting: 4" SQR, 4" OCT with a specially designed cover that • CFSM listed Single gang mud protects the thermistor while • MEA listed ring allowing maximum air flow. The • FM approved Rated Spacing: 70' between thermistor reads the temperature seniors on smooth from the air it takes in. It then ceilings. transmits a signal representing the — SILENT Compatible Bases: SD505 -6AB temperature to the IntelliKnight (Sold Separately) (6' Base) D505-4AB panel. .. KNIGHT (4" Base) (4" Base) 0 INTEtIKNIGHTACCESSORY 2 ;a Model SD5O5 -AHS • Addressable Heat Detector Eng!ag ns The contractor shall furnish and install where indicated on the plans, addressable heat detector Silent Knight SD505 -AHS. The combination detector head, and twist -lock base, shall be UL listed compatible with Silent Knight's IntelliKnight 5820XL fire panel. The base shall permit direct interchange with Silent SD505 -APS Photoelectric Smoke Detector, or SD505 -AIS • Ionization Smoke Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal - resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Voltage and RF /transient suppression techniques shall be employed to minimize false alarm potential. H Diameter = 5- 15/1 H Diameter = 3- 15/16" HI N 0 <1<# ii\- 0. f ' ; \ '' 4 i itnd-bA - , . : ....p Height = 2 inches, l" including base 1 rib l j'''. ) (Ica l 0 Model SD505 -6AB Detector Base Model SD505 -AHS Detector Head (Front View) (Front View) • tv SILENT KN 7550 Meridian Circle, Maple Grove, MN 55369 -4927 MADE IN AMERICA 800 - 446 -6444 or in Minnesota 763 - 493 -6435 FORM# 350229, Rev. 01/01 FAX: 763 -493 -6475 Copyright ©2001 Silent Knight World Wide Web: http: / /www.silentknight.com A U D J B E/ tU J S J B L E • N . O T! F f G'A J aN SPECT ._ .. rt Selectable Output Strobe �� SYSTEM and Ho rn / Strobes SENSOR Models Available • „-� ` "' � � ,- 7 t� Strobes F R °� � � _',, ' A..� -: ' ,°° s Red White t -v S1224MC S1224MCW "r S1224MCP S1224MCPW / % -cep S1224MCK A , _ S1224MCSP 5 ' - i Horn /Strobes `°= ' Air; I Red White I �_ . ' P1224MC P1224MCW ; P1224MCP P1224MCPW t ; t'" P1224MCK � s � `� 4 t '1 , ��� � t�.� s � f' P1224MCSP l k t` Y '" 1 , '� Z j ,. I Horns - ; . aa; s t Red White 4"' . H12/24 H12/24W M1 H12/24K Product Overview Operates on either 12V or 24V SpectrAlert Selectable Output Horns, Strobes, and Horn /Strobes offer enhanced fea- tures that Include the widest range of candela options available and the capability to Widest range of candela options: recognize and self - adjust for either 12 or 24 volt operation. With an overall feature 12V: 15 and 15/75 candela $et that combines performance, installation ease. flexibility, and a consistent, 24V: 15, 15/75, 30, 75, 110 candela aesthetically pleasing appearance, the SpectrAlert Selectable Output devices Easy candela selection provide both the innovation and efficiency synonymous with the SpectrAlert name, Lower current draw Performance. SpectrAlert selectable output wall - mount horns, strobes, and horn/strobes Easy DIP switch selection for horn offer key performance features long associated with the SpectrAlert name. The select - able candela strobes and horn/strobes offer average current draws that are not only options lower than conventional fixed- candela SpectrAlert products, but also lower than similar Easy mounting with QulckCllckT' selectable candela products. By consuming less current, the ability to connect even more Synchronlzable with MDL devices per loop is possible, resulting in a lower installed cost. Sync•ClrcuitTA/ module Installation. SpectrAlert selectable output horns, strobes, and horn/strobes offer the Meets UL1971, NFPA72, and ADA same installation- friendly features synonymous with the SpectrAlert name, such as the signaling requirements option of 2- and 4 -wire operation; the ability to use standard size backboxes with no encroachment into the box; and universal mounting incorporating the labor- saving All strobe and horn /strobe models incorporate QuickClick'" feature. Such labor - savings features make wire connections simple and fast, a new patented voltage booster design that has a more consistent flash bulb voltage over the further reducing installed cost. range of candela selections. The benefit to the Flexibility. SpectrAlert selectable output strobes and horn/strobes offer the broadest customer is a high quality strobe device. range of candela options. In addition, the selectable output strobes and horn/strobes - can operate on either 12V or 24V, with no setting required; the device recognizes and ■ O self- adjusts to the correct current automatically. Temporal 3 or Continuous tone options continue to be available, in either an Electromechanical or 3kHz pattern. iiiihthai S1 Aesthetics. SpectrAlert selectable output horns, strobes, and horn/strobes incorporate 7125-1209:222 54011 71351209:223 the same stylish, low profile design of the conventional SpectrAlert products, for a con- 4; NEA sistent and aesthetically pleasing appearance across the entire product line. approved 4N•0+. 112-07 -E 3014150 12&02 -E Engineering Specifications General fire protective service. Horn /strobe shall be wired as a primary SpectrAlert horns, strobes and horn/strobes shall he capable of signaling notification appliance and comply with the Americans mounting to a standard 4" x 4" x 1 back box or a single gang with Disabilities Act requirements for visible signaling appliances, 2' x 4' x 1' /a" back box using the universal mounting plate flashing at 1Hz over the strobe's entire operating voltage range. included with each SpectrAlert product. Also, SpectrAlert prod- The strobe light shall consist of a xenon flash tube and associated ucts, when used in conjunction with the accessory Sync•Circuit lens/reflector system. The horn shall have two tone options, two Module, shall be powered from a non -coded power supply audibility options (at 24 volts) and the option to switch between and shall operate on 12 or 24 volts. 12 volt rated devices shall a temporal 3 pattern and a non - temporal continuous pattern. have an operating voltage range of 9 -17.5 volts. 24 -volt rated Strobes shall be powered independently of the sounder with the devices shall have an operating voltage range or 17 -33 volts. removal of factory installed jumper wires. The horn on horn/ SpectrAlert products shall have an operating temperature of strobe models shall operate on a coded or non -coded power sup - 32° to 120 °F and operate from a regulated DC or full wave ply (the strobe must be powered continuously). rectified, unfiltered power supply. Synchronization Module Strobe Module shall be a System Sensor Sync•Circuit listed Strobe shall be a System Sensor SpectrAlert Model to UL 464 and shall be approved for fire protective service. The listed to UL 1971 and be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns strobe shall be wired as a primary signaling notification appliance at temporal 3. Also, the module shall silence the horns on horn/ and comply with the Americans with Disabilities Act require- strobe models, while operating the strobes, over a single pair of ments for visible signaling appliances, flashing at 1Hz over the wires. The module shall be capable of mounting to a 4 x strobe's entire operating voltage range. The strobe light shall con- 4 /i6" x 2 back box and shall control two Style Y (class B) or sist of a xenon flash tube and associated lens/reflector system. one Style Z (class A) circuit. Module shall be capable of multiple zone synchronization by daisy chaining multiple modules together Horn /Strobe Combination and re- synchronizing each other along the chain. The module Horn/Strobe shall be a System Sensor SpectrAlert Model shall not operate on a coded power supply. listed to UL 1971 and UL 464 and shall be approved for Specifications Walk Test Weight, horn only Voltages SpectrAlert horn /strobe and horn only 7.2 oz. 12 or 24VDC and FWRi unfiltered work on "walk tests' with time dura- Weight, strobe and horn /strobe Operating voltage range tions of 4 seconds or greater 8.8 oz 12V: 8- 17.5V; 24V: 16-33V Input Terminals Mounting Operating voltage range (with 12 to 18 AWG 4' x 4" x 1 or 2" x 4" x 1 Sync•Circuit module, MDL) Dimensions standard boxes 12V: 9- 17.5V; 24V: 17 -33V Strobe and horn/strobe with universal Operating Temperature (Indoor) U.S. Patent Numbers plate 32 °F to 120 °F (0 °C to 49 °C) 5,593,569 5" x 5 x 2 /ie" 5,914,665 Strobe and horn /strobe with small Maximum humidity (Indoor) 6,049,446 footprint plate 95% as tested per UL464 3 x 5 x 2 Outdoor (K Series) Operating Temperature • Horn with universal mounting plate —40 °F to 151 °F 5" x 55/a` x 15/16' (-40 °C to 66 °C) Horn without mounting plate Outdoor rating 2 /t8" x 5 x 1 NEMA 3R (per UL 50) Notes 1. Full Wave Rectified (FWR) voltage is a non- regulated, time - varying power source that Is used on some power supply and panel outputs. 2. The MDL causes a one -volt voltage drop In the notification appliance circuit. Table 1 -A: SpectrAlert Strobe UL Max. Current Draw Explanation of Published Voltage, Current, and SPL FbVR Operating DC Operating Specifications Current - Stroh -a Current -Strobe Candela (mA RMS) (mA RMS) In May 2004 Underwriters Laboratories changed standard Setting 8 -17.5V 16-33V , 8 -17.5V 16-33V UL 1971 to require that operating current measuremments 15 112 64 127 59 are made using RMS (root mean square) instead of peak 15/75 135 74 127 69 or average values. RMS measurements more accurately 30 ig,01110 93 w,;=:�� :41 : 90 predict the power consumption of a device since they take 75 X. ekliti.S 158 L:.`. 160 110 aatigmg 208 ='=n 209 into account the entire current draw profile including surge, repetitive surge, and peak values. The published RMS cur- rent is the maximum operating current of that device within its operating voltage range. This current maximum may or Table 1-B: Horn UL Max. Current Draw Measurements (mA RMS) may not occur at the endpoints of the voltage range. DC F1VR Selectable Horn Tones 8-17.5V 16-33V 8-17.5V 16-33V . Similarly, UL tests the audibility of devices in accordance Temporal Low Electromechanical 15 23 13 23 with UL 464 by measuring them across the operating volt - Volume 3000 Hz interrupted 15 33 13 23 age range to determine the minimum sound pressure level High Electromechanical 36 53 20 44 produced at any particular setting. Volume 3000 Hz Interrupted 43 57 21 40 Non- Lox Electromechanical 16 37 19 29 During May 2004, UL also changed the way they list the Temporal Volume 3000 Hz Interrupted 16 32 1s 33 voltage range of a device. All 12V products will be listed High Electromechanical 38 49 46 49 between 8 - 17.5V and all 24V products will be listed Volume 3000 Hz Interrupted 44 56 42 58 between 16 - 33V. Those devices are considered "regulat- ed". Any product that does not operate within these ranges will be listed as a "special application" with its operating • Table 1 32VDC Horn /Strobe UL Max. Current Draw voltage specified on the device. Measurements (mA RMS) Temporal Notes Low Volume HIgh Volume 1. Current draw for strobe -only products is shown in Table 1 -A. Candela Electromechanical 3000 Hz Electromechanical 3000 Hz 2. Current draw for horn -only products Is shown in Table 1 -B. Setting 3. 12VDC 2 - wire horn /strobe current Is shown in Table 1 - C. 15 111 111 112 112 15/75 127 127 126 129 4. 24VDC 2 -wire hom /strobe current draw Is shown In Table 1-0. Non - Temporal 15 113 112 114 115 5. Current draw for other hom /strobe power supplies can be calculated by adding the strobe current in Table 1 -A to the 15/75 128 128 130 134 horn current in Table 1 -B from the chosen settings. Table 1 -D: 24VDC Horn /Strobe UL Max. Current Draw SpectrAlert Strobe Candela Selections Measurements (mA RMS) For strobe candela selection, adjust slide switch located on the Temporal rear of the product while watching the viewing window on the Low Volume High Volume side of the reflector. Candela Electromechanical 3000 Hz Electromechanical 3000 H Permissible Candela Settings Setting Candela Operating Voltage 15 71 70 73 75 Setth 12V 24V P ' 41111 ng 15/75 86 85 87 f olio.' i� 15 OK OK 30 99 98 100 100 `a1m 15J75 OK OK 75 166 166 167 170 - � 30 OK 75 110 209 209 210 213 � OK Non-Temporal 110 OK ' 15 74 74 79 82 V iewing Window A013300 15/75 86 88 93 96 30 101 101 107 110 75 167 167 173 176 110 213 213 218 222 • SpectrAlert Horn Sound Measurements (dBA) Typical weatherproof mounting with universal plate + WBB Plate ee -36 x 1(2 Flat Head Selectable Horn Tones 8 -17.5V 1533+1 �_�_�� r Screw(4total) Ir y �_ � , Temporal Low Electromechanical 67 75 _ �__, .. r "_ ' as Volume 3000 Hz Interrupted 68 75 � High Electromechanical 71 80 Volume ' \a III I • 3 000 Hz Interrupted 72 81 I I �'� ll Nor- Low Electromechanical 71 79 II Tampon Volume . , 3000 Hz Interrupted 72 79 i ' 1 `a �I High Electromechanical 76 84 Gasket 1 ```, ! �i • Xs Volume 3000 Hz Interrupted 77 86 Sid Paper Liner Locking Rib DIP Switch Operation on P1224MC ask G et m Gasket Aot Factory OFF ON Defa I DIP Switch Low I II High ri Temporal .I I Nov- Tenpora) il m tf Be trornech. I- I XcrMz o o Base (rear) Ash o-00 SpectrAiert Ordering Information Model Description model Description P1224MC Selectable Output Horn /Strobe, 12/24 volt, red H12/24 Horn, 12/24 volt, red P1224MCW Selectable Output Horn /Strobe, 12/24 volt, white H12/24W Horn, 12/24 volt, white P1224MCP Selectable Output Horn /Strobe, 12/24 volt, red, H12/24K Horn, 12/24 volt, red, outdoor plain housing Accessories P1224MCPW Selectable Output Horn /Strobe, 12/24 volt, MDL Sync•Circuit Module, red white, plain housing P1224MCK Selectable Output Horn /Strobe, 12/24 volt, red, MDLW Sync•Circuit Module, white outdoor MDLWA Sync•Circuit Module, white, Canadian model P1224MCSP Selectable Output Horn /Strobe, 12/24 volt, red, S-MP Small Footprint Mounting Plate, red, for single - 'FUEGO' housing gang back box S1224MC Selectable Output Strobe, 12/24 volt, red S-MPW Small Footprint Mounting Plate, white, for single - S1224MCW Selectable Output Strobe, 12/24 volt, white gang back box S1224MCP Selectable Output Strobe, 12/24 volt, red, plain BBS Surface Mount Back Box Skirt, red housing BBSW Surface Mount Back Box Skirt, white S1224MCPW Selectable Output Strobe, 12/24 volt, white, D-MP Universal Mounting Plate (replacement), red plain housing D-MPW Universal Mounting Plate (replacement), white S1224MCK Selectable Output Strobe, 12/24 volt, red, WBB Weatherproof Back Box outdoor 51224MCSP Selectable Output Strobe, 12/24 volt, red, " FUEGO' housing Notes All of these SpectrAlert products are designed for wall mount only. All outdoor models must use weatherproof back box model WBB. Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 22). However, it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. All 15175 candela strobes or horn/ strobes are recommended for 20' x 20' rooms or less. System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor In China System Sensor — Far East System Sensor — India 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.8832.0119 Ph: 85.22.191.9003 Ph: 91.124.237.1770 x.2700 St. Charles, IL 60174 Fx: 905.812.0771 Fs: 86.29.8832.5119 Fx: 85.22.736.6580 Fx: 91.124.237.3118 Ph: 800 /SENSOR2 System Sensor Europe System Sensor In Singapore System Sensor — Australia System Sensor — Russia Fx: 630/377-6495 Ph: 44.1403.276500 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 www.systemsensor.com Fx : 44.1403.276501 Fx: 65.6273.2610 Fx: 613.54.281.172 Fx: 70.95.937.7983 0 2005 System Sensor. The company reserves the rlgnt to change product specifications without notice. A05-0325-006•9/O5•#1525 Silent Knight SD500 -AIM Addressable Input Module Page 1 of 2 ii 1 STUNT KNIGHT SK Home let Products 16 System Tools fit, Support IS About SK Contact Us ill Search SD500 -AIM Addressable Input Module Document Downloads Control./System Tools H. Battery Calcs CSFM Listings Troubleshooting PDF Downloads Products EaT : Fire Alarm Systems Digital Receivers Telephone Entry Systems III Fast Fax Newsletter Signup Knight School Training The SD500 -AIM and SD500 -MIM are addressable input modules for use with Silent Agency Links Is Knight's IntelliKnight fire control panel. The SD500 -AIM and SD500 -MIM are design€ Silent Knight Press Releases be used with pull station, water flow switches, and other applications requiring dry co Trade Show Calendar alarm initiation devices. Support The SD500 -AIM addressable input module mounts to a 4" -square box. The SD500- Contact Us p -s q Customer Survey mini input module fits inside a single gang box. The modules are Class B supervised Feedback/Request Form single input contact monitors. Using an EOL resister, they monitor for alarm contact Help on PDF and Zip Files closures and for open circuit wiring fault conditions. Software Updates Technical Support Home Technical Support Form The SD500 -AIM and SD500 -MIM offer a compact design for adaptability and pleasin! aesthetics as well as easy installation and stable operation - a flexible solution for all fire protection needs. Download: • SD500 -AIM Addressable Input Module Spec Sheet (54K PDF file) • SD500 -AIM Installation Sheet (208K PDF file) • SD500 -AIM CSFM Listing (39K PDF file) • SD505 -AIM UL Listing UOXX.S3511 Control Unit Accessories, System (39K p file) • Home I Contact us I Privacy Statement I Products I Product Catalog I Search I Site Map I Software I T Support ©2002 by Silent Knight Silent Knight is a Honeywell Company file: / /D: \skwebsite \htmfiles \fire \sd500aim.htm 10/10/2007