Permit , :r CITY OF TIGARD
,, DEVELOPMENT SERVICES MASTER PERMIT
h 1i: Y'� 1 PERMIT # • MST'�7 -00cc
-- -- "� -. . 13125 SW Hall Blvd., Tigard, 0R 97223 (503)639-4171 DATE ISSUED: 03 / 03 / 97
PARCEL: 2S104BA- -1E100
SITE ADDRESS...: 13696 SW LIDEN DR
SUBD I_ V I S I ON.... _ .: CPSTLE HILL Nl:. 3 ZONING a R-12 PD
BLOCK • LOT .............. '? 1
Remarks: Path 1
------------------ --- - - - - -- BUILDING - - - --
REISSUE: STORIES : 2 FLOOR AREAS - - - - -- BASEMENT...: 0 sf REQUIRED SETBACKS---- REQUIRED------- --
CLASS OF WORK.:NEW HEIGHT • 26 FIRST • 1455 sf GARAGE • 587 sf LEFT : 5 SMOKE DETECTRS: Y
TYPE OF USE... :SF FLOOR LOAD • 40 SECOND...: 1587 sf FRONT : 24 PARKING SPACES: 1
TYPE OF CONST.:5N DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT : 5
OCCUPANCY GRP.:R3 BDRM: 3 BATH: 3 TOTAL ---: 3042 sf VALUE..$: 213888 REAR : 37
-- - -- - - -- — — - - - -- PLUMBING --------- - - ---- --
SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 0 RAIN DRAIN ft: 0 TRAPS • tr
LAVATORIES • 4 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 0 SF RAIN DRAINS: 1 CATCH BASINS..: 0
TUB /SHOWERS...: 4 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 100 BCKFLW PREVNTR: 1 GREASE TRAPS..: 0
OTHER FIXTURES: 0
- ------------- - ---- - - - - -- MECHANICAL ---- - - ---- --------------- - - - --
FUEL TYPES -- FURN (100K ..: 0 BOIL/CMP ( 3HP: 0 VENT FANS • 4 CLOTHES DRYERS: 1
/GAS/ / / FURN ) =1',4K ..: 1 UNIT HEATERS..: 0 HOODS • 1 OTHER I. ITS...: 1
MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS : 0 WOODSTOVES • 0 GAS OUTLETS...: 1
- ----- ---------- ------ -- - - - - -- — ELECTRICAL ------- -,_------- -- - - -- ------- - - - - --
- RESIDENTIAL UNIT - -- - -- SERVICE /FEEDER -- —TEMP SRVC /FEEDERS— -- BRANCH CIRCUITS - -- -- MISCELLANEOUS ---- - -ADD'L INSPECTIONS- -
1000 SF OR LESS: 1 0 - 200 amp..: 0 0 - 200 alp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 5s SF.: 6 201 - 4 %' amp..: 0 201 - 400 alp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR • 0
LIMITED ENERGY.: 0 401 - 600 amp..: 0 401 - 600 amp..: 0 ER ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT : 0
MANF HM /3VC /FDR: 0 601 - 1m amp.: 0 601 +amps -1000 v: 0 MINOR LABEL -10: 0
1m+ amp /volt.: 0 ---------------- - - - - -- PLAN REVIEW SECTION - - - - - --
Reconnect only.: 0 )=4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC:
----------- - - - - -- - - - -- ELECTRICAL - RESTRICTED ENERGY - - -- - - - - - -- - -- --
A. SF RESIDENTIAL--------------------------- B. COMMERCIAL ----- — ------ ------------ - --
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM INTERCOM /PAGING: OUTDOOR LNDSC LI:
BURGLAR ALARM..: OTH: :: X BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SI6NL:
GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICAL OTHR: ::
HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL # SYSTEMS: 0
Owner: - - - - -- ------------------Contractor: ----- ---- - - - --- TOTAL FEES:$ 3215.55
DON MORISSETTE HOMES DON MORISSETTE HOMES
5000 SW MEADOWS RD 5000 SW MEADOWS RD
SUITE 151
LAKE OSWEGO OR 97035 LAKE OSWEGO OR 97035
Phone #: 620 -7538 Phone #: 620 -7538
Reg #..: 35533
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other
applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180
days of issuance, or if work is suspended for more than 180 days.
--------- - - - - -- --- ----- -- -- REQUIRED INSPECTIONS ------ ---- --- --------------- --
Erosion Contol Post /Beam Nechan Electrical Servi Fireplace Insp Rain drain Insp Mechanical Final
Grading Inspecti Crawl Drain Electrical Rough Gas Line Insp Water Line Insp Plumb Final
Footing Insp PLM /Underfloor Framing Insp Gas Fireplace Water Service In Building Final
Foundation Ir•.sp Mechanical Insp Shear Wall Insp Insulation Insp '._ • /Sdwlk Insp
Post /Beam Struct Plumb Top Out Low Voltage 6yp Board Insp Elect 'cal Final
Per�mittee Signatur e: Issued B : . .) / / /IL,e A
Call for inspection — 639 -4175
r Plan Check # 0i
:1TY OF TIGARD Residential Building Permit Application Rec'd By breA
13125 SW HALL BLVD. New Construction Additions or Alterations Date Rec'd off? /'97
'1GARD, OR 97223 Single Family Detached /Attached (1 or 2 units) Date to P.E. I
503) 639 -4171 Date to DST -, — 7
Permit # `5V11-Ob72- i q7 -
Print or Type BOZI
Called
Incomplete or illegible applications will not be accepted
Name of Project `` N�
Job t- '\ I - III �1�,
S i a Add re s Architect Mailing Address
Address 1 L SIN lUaeXr '. vv t'l EPID5 le-r) .
City /State Zip Phone
Name t-�� tint-l!?� L �. r Q7 U? - 7�.�3
Owner M ilin Address ame�U (5' t•IEr..-S
MENJ Engineer Mailing Address
L. pity/State Zi Phone g OR ' `a
.0. t t " ' _� City/ISta �� H PIZ-NJ 5r.
tat`e �Z,iP� � Ph 1 one
Name ,� -- 11(.<a), p Ce g 7 3 L,,C++ i - 70:)
j
General �� E'L3F _t j E { IE t't"t j7 Describe work New • Addition 0 Alteration 0 Repair 0
Contractor Mailing M � to be done:
.l re J Type of Use
Tity'State `„ Z i p Phone
LL , o C� - Type of Construction t,l� " I i .
Oregon Const. Cont. Board Lic.# p Date CJ �"-�c7
Attach Copy of 3SS 3 � e1670 Occupancy Class
Current COT siness Tax or Metro # Exp. Date
Licenses L.° - ` -'1 Will it be sprinklered? Yesp NoK
Name If Yes, separate FLS plans and
C hu ^ ' applica to be submitted
Mechanical t�l �/ I Number of Stories
Sub- Mailing Address 0
Contractor, t2j( 51 .: ki-S' j L -D. Proposed Use ej 71 4DE✓1z1 tp2,
City /State ZIP Phone
. biR The e- 31 15 Previous Use
Ore on C sf Cont. Board Lic.# Ex Da (/
Attach Copy of W � Valuation $ 7 / -5 . ��G �
Current COT Business Tax or Metro # qate
Licenses I. 1 Cp Rt I 7 NEW CONSTRUCTION ONLY:
Name Building ID
Plumbing .� ° 17t 1_.E l�.k.m- P> Nor Unit Types - square ft. # of units
Sub- Mailing Address
A.)
Contractor PQ - BOY. lSLO
B.)
City/State Zip Phone.
'i1.t°a71N, D1 c lam' 43 o C.)
Oregon Const. Cont.. Board Lic.# Ex a e D.)
Attach Copy of i On . 1 1 Will the electrical subcontractor wire for all restricted YAs N
Current Plumbi�ngLi t
c_# ExR. energy installations?
Licenses ✓ 1 l�`-r 3 `f I4 Has the Subdivision Plat recorded? N/A See No
COT Business Tax or Metro # Ex
9 io **?)5 8 / 7 Ian I hereby acknowledge that I have read this application, that the
Name information given is correct, that I am the owner or authorized agent of
Electrical Reth 1=.-�° the owner, and that plans submitted are in compliance with Oregon
Sub- Mailing Address State laws.
t A �, r 1Le • nature of Ow Q I �
Contractor U Y `+ � `
1 i L 61 Q7 ELI p Name
l�l 3T MD - -2 5- Phonp
Oregon Const. r:nnt. Board p Lic.# Date FOR OFFICE USE ONLY:
Attach Copy of 0 I I S --I L I2�0 Plat # Map/TL# Zone
Current Elect( �ILi�. # Expp ,pa
Licenses � 5 1 U l 1 k5 1 9 - z. 751 O n - R O M `12
COT one s�T i or Metro # E5p a Engineering Approoval p Planning FriF .
dsts\sfapp.doc li/ / t Lf119 �11TF i � 17�tJ�N` I-13-9/ Ap ra t
1h- OK -&J
=. .,� ,
Permit # Account Description Amount Amt. Pd. Bal. Due
/7n /i_uu12 MST. Permit (BUILD) 7 /li.' _ ,/7 /f ..
Plumb. Permit (PLUMB) .2.2s, w VP.?.)-.
w
Mech. Permit (MECH) s,/,'. ,4.7',
ELC /ELR Permit (ELPRMT) 300. /30A 65'
State Tax (TAX) Cif, ‘1
Bldg: 35. /
Plumb: //. /
Mech: c2, Z/ /
ELC /ELR: A5... 7
Plan Check •
MST: ✓dMi 4 A4 " ( BUPPLN) ✓,S Z- Z9c
14“
Plumb: (PLMPLN)
ef
Mech: (MECPLN) // l� ��
CflC pi_v .. a p.e0
CDC Review (LANDUS) ///G `" 4- 1°"'`'" ✓
449_voz ( • Sewer Connection (SWUSA) ( A 0 ,/0 U— 2 D a
Sewer Inspection • (SWINSP) aid , 3 ) '
Parks Dev Charge (PKSDC) /05d ,i /t0 S®
Residential TIF (TIF -R) --
Mass Transit TIF (TIF -MT)
Water Quality (WQUAL)
Water Quantity (WQUANT) /00 ,/ GO
Erosion Control Permit (ERPRMT) ey ✓ c(e
Erosion Planck/USA (ERPLAN) fib( 4.11. —
Erosion Planck/COT (EROSN) d 2 , 4 /
Fire Life Safety (FLS)
TOTALS: SOD, s--- -�� i sitle•
p
is \dsts\mstapp.doc ,; ' J
Rev. 7/96 i
•
` i
Page No. 1 CASE HISTORY FOR CASE NO.: MST97-0022
DON MORISSETTE HOMES
• 13696 SW LIDEN DR
07/22/97
•
Action Description Reg/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
- - -- --- -- ---- -- - --
MSTA005 Application received / / / / 01/21/97 RECD DRA 05/30/97 J *H
MSTA008 Permit Created / / / / 01/23/97 PEND B 01/23/97 BON
MSTA010 Check for prcl. restrict. / / / / 01/23/97 PASS B 01/23/97 BON
MSTA012 Plans routed to Plans Examiner / / / / 01/23/97 PEND B 01/23/97 BON
MSTA026 Plans approved by RPE / / / / 01/27/97 PASS RT 01/27/97 8T2
MSTA030 Reviewed plans routed to DSTS / / / / 01/27/97 PASS RT 01/27/97 BT2
MSTA032 DST Post - Review Completed / / / / 01/30/97 PASS DRA 03/03/97 DRA
MSTA080 (F) Ready to issue / / / / 01/30/97 Collect $248.83 for previous plan review PASS DRA 01/30/97 DRA
on MST96 -0553, those plans are attached
to these plans. Pay fees for MST96 -0553
& then void permit.
MSTA092 (F) Issue combination permit / / / / 03/03/97 PASS DRA 03/03/97 DRA
. MSTA095 Issue plumbing signature form / / / / 03/14/97 RECD JT 07/11/97 JT
MSTA097 Issue electric signature form / / / / 03/14/97 RECD JT 07/11/97 JT
MSTA700 Erosion Contol / / / / 03/05/97 PASS USA 03/05/97 RB
MSTA703 Grading Inspection / / / / / / 01/23/97 BON
MSTA705 Footing Insp / / / / 03/05/97 PASS RB 03/05/97 RB
MSTA706 Foundation Insp / / / / 03/05/97 pending- #4 rebar at HPAHD location rear PEND RB 03/06/97 RB
south location
•
MSTA706 Foundation Insp / / / / 03/06/97 PASS RB 03/06/97 RB
MSTA710 Post /Beam Structural / / / / 03/18/97 pending- remove wood debris; cross PASS RB 03/18/97 RB
girder missed; support plenum box;
missed stud behind furnace - marked.
MSTA711 Post /Beam Mechanical / / / / 03/18/97 see structural this date PASS RB 03/18/97 RB
MSTA713 Crawl Drain / / / / 03/13/97 PASS MS 03/13/97 MRS
MSTA717 PLM /Underfloor / / / / 03/18/97 PASS MS 03/19/97 MRS
MSTA720 Mechanical Insp / / / / 04/25/97 insulate horizontal duct w /in soffit; FAIL RB 04/25/97 RB
exhaust venting disconnected; protect
b -vent w /in attic; seat all thru hole
• penetrations w /in RA; gas connector &
shut off missing at fireplace unit;
remove wires away from fireplace; sael
gas line thru hole penetration to u/f in
garage.
MSTA720 Mechanical Insp / / / / 04/30/97 exhaust venting disconnect; insulate FAIL RB 04/30/97 RB
duct w /in soffit; seal all thru
penetrations w /in RA
MSTA720 Mechanical Insp / / /_ / 05/01/97 see insulation this date _ . FAIL RB 05/01/97 RB
MSTA720 Mechanical Insp / / / / 05/02/97 see insulation this date FAIL DD 05/02/97 RB
•
Page No. 2 CASE HISTORY FOR CASE NO.: MST97 -0022
ir
DON MORISSETTE HOMES
13696 SW LIDEN DR
07/22/97
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
•
MSTA720 Mechanical Insp / / / / 05/05/97 pending- remove drywall to view exhaust PASS RB 05/05/97 RB
venting
MSTA720 Mechanical Insp / / / / 04/25/97 1. Inadequate room on return plenum for FAIL DT 05/30/97 J *H
req'd r -8 insulation. 2. Verify minimum
2" clearance (R -8) insulation in return
and supply plenum. 3. Install screws at
insplicer collar as per instructions.
4. 4" vent connector to small (supply
GAMH chart to verify venting will work).
5. Supply proper connector for splice
•
at exhaust fan duct. 6. Inst. foil all
exhaust fans. 7. "8" vent lack
• • firestop at attic /top floor.
MSTA722 Plumb Top Out / / / / 04/21/97 need a proper ramp to house NR MS 04/22/97 MRS
MSTA722 Plumb Top Out / / / / 04/23/97 PASS MS 04/23/97 MRS
MSTA722 Plumb Top Out / / / / 05/12/97 upstairs soaker tub okay PASS MS 05/12/97 GES
MSTA723 Electrical Service / / / / 04/30/97 PASS DD 05/01/97 RB
MSTA724 Electrical Rough In / / / / 04/30/97 pending- neutral pigtail needed at LR PASS DD 05/01/97 RB
mutt. wire branch circuit; NM cable in
attic needs to be secured;
NM cable to exterior needs to be caulked
MSTA725 Framing Insp / / / / 04/30/97 mech issues; electrical cover; support FAIL RB 04/30/97 RB
notched stud at den; shim rafters aft
alcove of garage; master bedrm egress
•
exceeds height req'mts.
•
MSTA725 Framing Insp / / / / 05/01/97 see insulation this date FAIL RB 05/01/97 RB
MSTA725 Framing Insp / / / / 05/02/97 see insulation this date FAIL DD 05/02/97 RB
MSTA725 Framing Insp / / / / 05/05/97 pending- mech issue; shim rafters PASS RB 05/05/97 RB
MSTA726 Shear Wall Insp / / / / 04/03/97 upper C -wall detail missed (above FAIL RB 04/03/97 RB
garage); J -wall detailing- sheath both
sides 8 nail roc
MSTA726 Shear Wall •Insp / / / / 04/04/97 C -wall above garage- not installed FAIL RB 04/04/97 RB_
other issues as per garage wings to be
checked at framing
MSTA726 Shear Wall Insp / / / / 04/30/97 pending- J -wall sheathing application PASS RB 04/30/97 RB
•
Page No. 3 r CASE HISTORY FOR CASE NO.: MST97 -0022
DON MORISSETTE HOMES
13696 SW LIDEN DR
07/22/97
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd -
Code Sent Done Done Date By
•
---- - -- -- -- - - -- ---
MSTA735 Gas Line Insp / / / / 04/25/97 PASS RB 04/25/97 RB
MSTA740 Insulation Insp / / / / 05/01/97 laundry exhaust needs a reducer for 4" FAIL RB 05/01/97 RB
venting;
seal all thru hole penetrations w/in.RA;
support all rafters notched;
master bedrm egress req'd;
exhaust vent disconnected upstairs;
insulation incompleted.
MSTA740 Insulation Insp • / / / / 05/02/97 shear wall at J -nails penetrate FAIL DD 05/02/97 RB
sheathing
reducer needed at exhaust vent at
laundry;
master bedrm egress.
MSTA745 Gyp Board Insp / / / / 05/09/97 pending- b -vent clearance PASS RB 05/11/97 RB
partial un -cover at kitchen - maintain
nailing req
MSTA755 Rain drain Insp / / / / 03/13/97 PASS MS 03/13/97 MRS
MSTA760 Water Line Insp / / / / 03/13/97 PAS MS 03/13/97 MRS
MSTA765 Appr /Sdwlk lnsp / / / / 05/15/97 PASS PI 05/21/97 MRS
MSTA790 Electrical Final / / / / 06/26/97 Panel schedule not in compliance with PASS BRP 06/27/97 J *H
Art 384 -12, 110 -22, identification not
specific, not complete, not easily
understood.
Flex at garbage disposal to be secured
in accordance with ARt 350 -18, 110 -12.
Gap at recept in upstairs storage room,
sheetrock, Art 370 -21.
Wall plate left of fireplace not flush
410 -56(e) & 110-12.
MSTA790 Electrical Final / / / / 06/29/97 PASS BRP 06/29/97 J *H
MSTA795 Mechanical Final / / / / 06/27/97 PASS MS 06/29/97 J *H
MSTA795 Mechanical Final 06/29/97 / / 06/27/97 See mech. final notes. FAIL RC 07/09/97 J *H
MSTA797 Plumb Final / / / / 06/27/97 1. Kitchen sink requires a clean -out. FAIL MS 07/09/97 J *H
2. Tub needs caulking in front.
3. Tub valve.
MSTA797 Plumb Final / / / / 07/01/97 see bldg final notes this date PASS GS 07/02/97 J *H
•
•
•
•
Page No. 4 CASE HISTORY FOR CASE NO.: MST97 -0022
DON MORISSETTE HOMES
13696 SW LIDEN DR •
07/22/97 •
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
•
---- - -- -- - - ---- ---
MSTA799 Building Final / / / / 06/27/97 1. AC unit must be on concrete pad 3" FAIL RC 07/09/97 J *H
from earth.
2. Provide ladder to underfloor. •
3. All exterior openings must be sealed
and weathertight.
4. All holes in garage ceiling & walls
must be sealed with approved material. •
5. Stove not installed.
• 6. Need plumbing approval before
• building final.
MSTA799 Building Final 06/29/97 / / 06/30/97 1. Cap rain drain at rear of house. PASS GS 07/02/97 J *H
2. Previous final corrections approved.
3. Final plumbing and building
appproved. •
•
MSTA960 (F) Issue Cert. of Occupancy / / / / 06/30/97 mailed 7 -22 -97 JT 07/22/97 S *W
•
•
•
•