Loading...
Correspondence City • o f Tigard, Oregon 13125 SW Hall Blvd. • Tigard, OR 97223 NI ® October 15, 2007 Jim Standring Cedar Mill Townhomes II, LLC 12670 SW 68 Ave. Suite 400 Tigard, OR 97223 RE: NEW SINGLE FAMILY RESIDENCE Project Information Building Permit: MST2007 -00178 Construction Type: VB Address: 8147 SW Langtree St. Occupancy Type: R -3 Area: 2156 sq. ft. Stories: 2 The plan review was performed under the 2005 Oregon Residential Specialty Code. The review of the submitted plans will be completed when the following information is provided. 1. Show on (2) revised plan sheets how the braced panels at the main level on each corner of the fireplace will be constructed without penetrating them for the fireplace vent. 2. Clarify on a revised plan sheet 2 of 5, and 3 of 5 that the wing walls for the portal frame are equal widths, or provide engineered design. Provide (2) copies of this revision. 3. At the rear wall of the master bath, show a braced panel that meets code, or provide engineered design. Provide (2) copies of this revision. 4. The two ABPs at the front on the upper floor den are completely over an opening below. Revise to meet code, or provide engineered design. Provide (2) copies of this revision. 5. Provide (2) copies of the manufactured floor framing layouts and calculations. R106.1.1 Note: Any change in orientation of floor joists due to plan review items above must be shown on manufacture's floor joist layout. 6. Provide (2) copies of the beam calculations for all beams, girders and headers shown on the framing plans. RI06.1.1 7. Revise the one story portal frame detail to reflect the two story portal frame situation actually being built. 8. SHOW smoke detectors on the plan where required. 9. SHOW bathroom fans on the plan where required. 10. When responding, provide an itemized letter stating in what way each issue has been addressed in the revision. Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 4 T City of Tigard, Oregon 13125 SW Hall Blvd. ® Tigard, OR 9 7223 z k � 1' g � g g � * - IN ., When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Loraine Sellers Plans Examiner loraine @tigard - or.gov Phone: 503.718.2708 Fax: 503.624.3681 Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard - or.gov • TTY Relay: 503.684.2772 PROJECT ADRESS: 8147 SW Langtree St. Lot 18 Gage Forest PERMIT #: MST2007 -00178 PLANS REVISED BY: JEFF GERBERG -503- 218 -5121 ECEWFD PLAN CHECK RESPONSE: OCT 2 s CITY OF-U(I D Item #1: Moved bp 4' away from corner & added 2 hd8a hold downs to allow vent penetration. Item #2: Revised dimensions of wing walls so they are both equal. Item #3: Brace panel meets exceptions for brace panel over openings. Item #4: Removed abp at corner's. moved left side abp to align with lower floor corner & added straps. Added abp at front side corner of den that is within 8' of opposite bp. Item #5: Manufacturer's floor joist layouts to be provided by builder. Item #6: Designer's gravity calculations are provided. Manufacturer's truss /joists /beam calculations to be provided by builder Item #7: Revised portal frame sheet as requested. Item #8 & #9: Smoke detectors & fans shown on plans.