Permit CAN of TIGAR® \/' COMMUNITY DEVELOPMENT DEPARTMENT 13125 SW Hall Blvd. Tigard, Oregon 97223.8199 (503) 639 -4171 MASTER PERMIT PERMIT # : MST94 -045' 639 -4171 DATE ISSUED: 12/20/94 PARCEL: 1 S 125CD- 07200 SITE ADDRESS...: 09734 SW LANDAU PL SUBDIVISION LANDAU WOODS ZONING: R -4.5 B LOCI' LOT ............. :009 BUILDING - - - -- - -. REISSUE: DWELLING UNITS :I BASEMENT........ :0 sf CLASS OF WORK. :NEW BEDRMS :3 BATHS :3 GARAGE :441 sf TYPE OF USE... :SF FLOOR AREAS -- REQUIRED SETBACKS - - - -- TYPE OF CONST.: 5N FIRST -935 sf LEFT; :25 ft RIGHT .: 5 . ft OCCUPANCY GRP. :R3 SECOND... :1019 sf FRONT. :55 ft REAR.. :30 ft STORIES....... :2 FINBSMENT :0 sf REQUIRED HEIGHT........ :26 ft TOTAL• :1954 sf SMOKE DETECTORS. :Y FLOOR LOAD....:40 psf VALUE °....$: 133521 PARKING SPACES.. :1 Remarks: PATH I PLUMBING -- _ • SINKS.......... :1 FLOOR DRAINS....:0 BACKFLOW PREVNTRS.. :1 LAVATORIES..... :3 WATER HEATERS... :1 TRAPS .............. :0 TUB /SHOWERS.... :3 LAUNDRY TRAYS... :0 • CATCH BASINS....... :0 WATER CLOSETS.. :3 SEWER LINE (ft). :0 GREASE TRAPS....... :0 DISHWASHERS.... :1 WATER LINE (ft). :100 OTHER FIXTURES..... :0 GARBAGE DISP... :1 RAIN DRAIN (ft).:0 WASHING MACH... :1 SF RAIN DRAINS.. :1 MECHANICAL - __.--- •-- _.____ _ FEES FUEL TYPES - -- UNIT HTRS.. :0 type amount by date recpt /GAS/ / / VENTS ..... :0 TIF $ 4550.00 JF 12/20/94 - MAX INPUT :O BTU VENT FANS.. :4 SWM $ 180.00 JF 12/20/9 - FURN < 100K .. :0 HOODS. .....:1 SWM $ 100.1011 JF 12/20/94 - FURN >=100K ..:1 WOODSTOVES. :0 BPRT $ 518.00 JF 12120/94 - FLOOR FURN.... :0 CLO DRYERS.: 1 BPLC $ 336.70- JF 12/02/94 94- BOIL/CMP < 3HP :0 OTHER UNITS :1 B5PC $ 25.90 JF 12/20/94 -- GAS OUTLETS :1 PARK $ 500.00 JF 12/20/94 - Owner. - -• MPRT $ 45.00 JF 12/20/94 - MICHAEL CHURCH HOMES INC MPLC $ 11.25 JF 12/20/94 - 7440 SW 35TH M5PC $ 2.25 JF 12/20/94 - 38TH $ 225.00 JF 12/20/94 - PORTLAND OR 97219 PaPC $ 11.25 JF 12/20/94 - Phone #: 293 -2109 EROS $ 64.00 JF 12/20/94 - Contractor i _. -__. ERPC $ 20.•80 JF 12/20/94 - MICHAEL CHURCH HOMES INC ERPC $ 20.80 JF 12/20/94 - 7440 SW 35TH PORTLAND OR 97219 Phone #: 293 -2109 Reg #..: 91961 $ 3610.95 TOTAL This pereit is issued subject to the regulations contained in•the REQUI RED INSPECTIONS Tigard Municipal Code, State of Ore. Specialty Codes and all other Foot /found Insp Fireplace Insp applicable laws. All work will be done in accordance with approved Post /Beam Struct Gas Line Insp plans. This peroit will expire if work is not olal - within 180 Post /Beam .Mechan Insulation Insp days of issuance, or if work is suspended for .' - - 180 days. P l m / un d s l a b Insp Gyp Board Insp PLM /Underfloor Rain drain Insp Permittee Signature: Mechanical Insp Water Line Insp / Plumb Top Out Appr /Sdwlk Insp Issued By: Framing Insp Mechanical Final Call for inspection - 639-4175 Av • Residential Building Permit Application" ° � i )6 City of Tigard �' J 13125 SW Hall Blvd. ' I � Tigard, OR 97223 01. (503) 639 -4171 ) f P- "l . 3 Jobsite Address: 923 V5 / 4�i�i /l �� • 'i�o s Lot�j ubd • v s S i .. /4/ n: -t - Valuation:. — s- / Va I - Corner Lot Y N 3 j S 2/ Permit #:' :. .. ..... . .::::. n Flag Lot? Y N >':` Reis e . a Map :& TL:# f5 /: .6 ::: ;: 7 !:.:..i. i.:::;: S y% Owner: A / / ` Approval Req ?> ::: >:: ><::: >;`::<:: >::: >` >; Address: 2 � 5 P :::.; :. ,.. :.,,.. » :. L : #: = . -- : . .• kez / ,.i.:..'::-_.,':- (ix," 2::), ::::,:.:::„Er„.„.,.,..:::.:.:::,.....,::::.,:.....:.,..........:..........................„:„„„..„.„„„,:„.„:„„„„„,,,,,,,,:,:,,„:„:::,,,,:.,.......,......„. Phone s� 6 / O r� l� v/ 4 acto . ntr >: ».s u red::::::: ««'_` ` <`'`' < > < >` ;`' >` Co << >::: < ><!> Ite rn q Address: `: >:>Sutcon oars `s D'eta ` :«':` ; ••••_••:, : ` ` >;' < >` >> ; <:Truss ails Phone: g/96 - • • License # Contractor's is e nt .. ....:..: : ...........:::. . : (attach copy of current Oregon license) ) E Contact Name & Phone: l/ I t i4 /•S i SS C .. /L Subcontractors: Architect/Engineer: J Plumbing: (` /�(J � l (,l�'I � - Address: 0 /' /Iv zi 4' Mechanical: 4i //,741-7/1/ C (attach copy of current OR Contractor's License) Phone: JOB DESCRIPTION: //',(Ve /� ' Applicant Signature - & Phone - number - 6/1-7 Received by: Date Received: 2" Permit # Account Description Amount Amt. Pd. Bal. Due / M %- 04- Bldg. Permit (BUILD) _5 S7ey ,c-,,, v _ Plumb. Permit (PLUMB) 02 .7--C," 2 ..) ✓ Mech. Permit (MECH) z /c, 01) State Tax - (TAX) 3 9s1 d J l 3 ?, ,, 0 1 / Bldg: o2S. J . Plumb: //, L' J . Mech: g. 2, i • Plan Check PLANCK 3q 1. 95 , - 97 J- Bldg: 334' , 2° / . Plumb: Mech: //r 2‘ „5 4.0(1 -o-i/ Z Sewer Connection (SWUSA) 2 26- 224/0 Sewer Inspection (SWINSP) 3c 3 J Parks Dev Charge (PKSDC) S G U SG IJ 1 S,_____— - / Residential TIF (TIF -R) / 1/ 3 v / `/ 3 0 ✓ Mass Transit T1F (TIF -MT) / 7 - d / " Commercial TIF (TIF -C) Industrial T1F (TIF -1) Institutional T1F (TIF -IS) Office TIF (TIF -O) Water Quality (WQUAL) / (C/ `✓ Water Quantity (WQUANT) / al / & d I Fire Life Safety (FLS) Erosion Cntri Permit (ERPRMT) C 1 6, V. e,d I Erosion Planck/USA (ERPLAN) P-0 .5' 0 J Erosion Planck/COT (EROSN) ,p-t r .I v TOTALS: SM.5 . 9 il --- SS ` . • c ..)/ Page No. 1 CASE HISTORY FOR CASE NO.: MST94 -0459 MICHAEL CHURCH HOMES INC 09734 SW LANDAU PL 06/16/98 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By MSTA007 Application received / / / / 12/02/94 PASS JF 12/15/94 BLT MSTA010 Plan check deposit paid / / / / 12/02/94 PASS JF 12/15/94 BLT MSTA020 Plan check by 12/15/94 / / 12/15/94 PASS RT 12/15/94 BLT MSTA030 Check for prcl. restrict. / / 12/15/94 12/15/94 PASS JLG 12/15/94 BLT MSTA050 Hold for / / / / 10/21/97 e mail from mark roberts september 19. NOTE JT 10/21/97 JT "I went to site, did not find where all required trees had been planted. It looked like 3 -4 had been planted. Mr Church agreed to plant 15 trees on three lots in response to a court order involving a citation for illegal tree removal. Mark will send a letter to current tax records listing as property owner & Michael Church. If that does not work, bring him into court for not meeting the court order. this will likely take some time." David Scott's response "follow up and let me know what happens" MSTA055 Hold Release to Issued / / / / 06/05/98 PER MARK ROBERTS "DELETE HOLD, mATT AND JT 06/05/98 JT i JUST CAN'T FIND THIS GUY" MSTA092 (F) Issue combination permit / / / / 12/20/94 JF 12/20/94 JF MSTA097 Issue plumbing signature form / / / / 12/20/94 JF 12/20/94 JF MSTA705 Foot /found Insp / / / / 12/28/94 PENDING- USA INSPECTION; SEISMIC PASS RB 12/28/94 RB RESTRAINT; CRAWL DRAIN MSTA705 Foot /found Insp / / / / 01/03/95 pending- additional vent palcement. PASS RB 01/03/95 RB MSTA710 Post /Beam Structural / / / / 01/18/95 APP SUBJECT TO SOLID BLOCK OR SHEATH PEND GS 01/18/95 GES BOTH SIDES OF PONY WALL W/ STUDS LESS THAN 14" PRIOR TO INSULATION WHEN CALLING FOR MEC ROUGHIN OR TOP OUT CALL FOR UNDERFLOOR ALSO MSTA710 Post /Beam Structural / / / / 03/06/95 GUSSET ALL POSTS 4' AND OVER ON BOTH DIS GS 03/06/95 GES SIDES MSTA710 Post /Beam Structural / / / / 03/08/95 PASS RB 03/09/95 RB MSTA711 Post /Beam Mechanical / / / / 03/03/95 N/R GS 03/06/95 GES MSTA711 Post /Beam Mechanical / / / / 07/26/95 PASS RB 08/01/95 RB MSTA713 Crawl Drain - - - / /- - -/- - / -- `03 runs - to dry well - - -- - --- - - -- PASS -MS- 03/07195 MRS - - - MSTA717 PLM /Underfloor / / / / 03/03/95 APP GS 03/06/95 GES MSTA720 Mechanical Insp / / / / 03/15/95 APP GS 03/15/95 GES Page No. 2 CASE HISTORY FOR CASE NO.: MST94 -0459 MICHAEL CHURCH HOMES INC 09734 SW LANDAU PL 06/16/98 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By MSTA722 Plumb Top Out / / / / 03/03/95 APP GS 03/06/95 GES MSTA725 Framing Insp / / / / 03/15/95 2X10 FL JOISTS OVER FAMILY RM OVER SPAN, DIS GS 03/15/95 GES BLOCK AT MID POINT MSTA726 Framing < REINSP> / / / / 03/20/95 # -1- corrections not done from prior DIS KS 03/20/95 KBS inspection (GS) fl/ joist over span at liv/ rm block at mid span as indicated MSTA726 Framing <REINSP> / / / / 03/21/95 APP KS 03/21/95 KBS MSTA735 Gas Line Insp / / / / 03/16/95 APP GS 03/16/95 GES MSTA740 Insulation Inap / / / / 03/21/95 APP KS 03/21/95 KBS MSTA745 Gyp Board Insp / / / / 03/27/95 # -1- seal joint adjacent to furnace A/N KS 03/27/95 KBS plenum at stem wall ( 26 gage sheet metal MSTA755 Rain drain Insp / / / / 01/06/94 PASS MS 01/09/95 MRS MSTA760 Water Line Insp / / / / 01/06/94 PASS MS 01/09/95 MRS MSTA765 Appr /Sdwlk Insp / / / / / / no request for reinspection. send JF 12/27/95 JF letter with cert. of occup per Letha Thomas MSTA765 Appr /Sdwlk Insp / / / / 06/05/95 FAIL LT 06/20/95 JS MSTA770 Misc. Inspection / / / / 03/06/95 exterior shearwall only app PART GS 03/06/95 GES interior hds and shearwalls insp not wanted at this time MSTA770 Misc. Inspection / / / / 03/08/95 shear- incompleted as per insp dtd. PEND RB 03/09/95 RB 3/3/95. MSTA770 Misc. Inspection / / / / 03/16/95 EXTER SHEATHING NAIL APP APP GS 03/16/95 GES MSTA770 Misc. Inspection / / / / 08/01/95 EFA MJR 08/01/95 MJR MSTA795 Mechanical Final / / / / 06/05/95 # -1- see inspection notes DIS KS 06/06/95 KBS MSTA795 Mechanical Final / / / / 07/26/95 SEE REPORT FAIL RB 08/01/95 RB MSTA797 Plumb Final / / / / 06/05/95 PASS MS 06/06/95 MRS MSTA799 Building Final / / / / 06/05/95 # -1- see inspection notes DIS KS 06/06/95 KBS MSTA799 Building Final / / / '/ 07/26/95 SEE REPORT FAIL RB 08/01/95 RB Page No. 3 CASE HISTORY FOR CASE NO.: MST94 -0459 MICHAEL CHURCH HOMES INC 09734 SW LANDAU PL 06/16/98 Action Description Reg/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By MSTA799 Building Final 04/28/98 / / 07/27/95 ELECTRICAL FINALED 5/9/95. PLUMBING PEND KS 04/28/98 JT FINALED 7/27/95 1. NEED FINAL EROSION CONTROL APPROVED. PAST 7/27/95 2. NEED SIDEWALK & APPROACH FINALED. MSTA960 (F) Issue Cert. of Occupancy / / / / 07/27/95 NOT MAILED; COPY TO FILE 6/15/98 FILE VN 06/15/98 VLN MSTB706 Erosion Control / / / / 07/27/95 W/C APP 07/27/95 KBS MSTB707 Wtr Proofing Bsm't Walls / / / / / / 12/15/94 BLT MSTB713 Crawl Drain / / / / 03/03/95 needs to be pumped or dry well DIS GS 03/06/95 GES no backwater valve MSTB714 Ftg Drain Bsm't Walls / / / / / / 12/15/94 BLT CITY OF TIGARD BUILDING INSPECTION NOTICE Inspection Line (Rec -O- Phone): 639 -4175 Business Phone: 639 -4171 Inspection: Footing Susp. Ceiling Sprink. Rough -in Appr /Sdwlk Foundation Plbg. Underslab Mech. Rough -in Fireplace Post /Beam Struct. Plbg. Top Out Elec. Rough -in �E1NIAL? Post /Beam Mech. San. Sewer Gas Line '2 field.. Plbg. Underfloor Rain Drain Framing - Plumb. Alarm Water Line Insulation Underflr. Insul. Shear Wall Gyp. Bd. Elect. Date Requested: I J '7 I 9, Time: AM PM Address: Builder: g 7 7,s" Permit #: - 7 THE FOLLOWING CORRECTIONS ARE REQUIRED: /24.494e -CV - LZ ` 70c,.€6 • 7-- 4 -- Inspector: Date: 7 - 2_7 —F5 APPROVED DISAPPROVED ' STOVED SUBJECT TO ABOVE _Call For Reinsp.