Permit CITY OF T1GARD ASTER PERMIT
10, DEVELOPMENT SERVICES �ERh4IT° ° ° ° ° ° ° ° h1sT98 -043
= �'1+� 1 p I ��l� 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 1 l+ 198
PARCEL: 1S125CD —TIG06
SITE ADDRESS...:09879 SW LANDAU PL
SUBDIVISION....:TIGARD WOODS ZONING: R -4.5
BLOCI'..... °.. °.. LOT °006 JURISDICTION: TIG
Remarks: Path I
__— ______ —____ — __ - -_ - -- - - - - --- BUILDING ------- - - - - --
REISSUE: STORIES • 2 FLOOR AREAS- -- - - -- BASEMENT...: 0 sf REQUIRED SETBACKS -- REQUIRED ---- --
CLASS OF WORK.:NEW HEIGHT • 23 FIRST • 1235 sf GARAGE • 489 sf LEFT : 7 SMOKE DETECTRS: Y
TYPE OF USE...:SF FLOOR LOAD : 40 SECOND...: 1280 sf FRONT • 20 PARKING SPACES: 2
TYPE OF CONST.:SN DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT • 5
OCCUPANCY GRP.:R3 BORN: 4 BATH: 3 TOTAL - -: 2515 sf VALUE..$: 184968 REAR • 92
-- ----------------------- --- - -- PLUMBING - - - -- ________________ — — —
SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 1 RAIN DRAIN ft: I'"" TRAPS • 0
LAVATORIES • 4 DISHWASHERS...: 1 FLOOR DRAINS..: 0 SEWER LINE ft: 1'' SF RAIN DRAINS: 1 CATCH BASINS..: 0
TUB /SHOWERS...: 3 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 100 BCKFLW PREVNTR: 1 GREASE TRAPS..: 0
OTHER FIXTURES: 0
- -- ---- -- — - - -- MECHANICAL -------- - _- _-- __ —__ -- —____—
FUEL TYPES FURN i 100K ..: 0 BOIL /CMP ( 3HP: .0 VENT FANS : 4 CLOTHES DRYERS: 1
6AS FURN ) =100K ..: 1 UNIT HEATERS..: 0 HOODS • 1 OTHER UNITS...: 1
MAX INP.: 0 BTU FLOOR FURNACES: 0 VENTS • 0 WOODSTOVES....: 0 GAS OUTLETS...: 1
- ------- __ _ — ----------- ELECTRICAL -- ----------------
- RESIDENTIAL UNIT -- — SERVICE /FEEDER -- —TEMP SRVC /FEEDERS -- --- BRANCH CIRCUITS -- - -- MISCELLANEOUS ---- - -ADD'L INSPECTIONS -
1000 SF ,OR LESS: 1 0 - 200 amp..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 500SF.: 4 201 - 400 amp..: 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR : 0
LIMITED ENERGY.: 0 401 - 6v< amp..: 0 401 - 600 amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT • 0
MANF HM /SVC /FDR: 0 601 - 1aa; amp.: 0 601 +amps- 1<<' v: 0 MINOR LABEL -10: 0
1m+ amp /volt.: 0 --------------- - - - - -- PLAN REVIEW SECTION - -- -
Reconnect only.: 0 ) =4 RES UNITS..: SVC /FDR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC OCC:
- -------- -------------------------------- ELECTRICAL - RESTRICTED ENERGY - - -- --- ------ ---- --- - --- ----
A. SF RESIDENTIAL - ---- -- B. COMMERCIAL---- _ --- - - - -__ — _____— ______- --- _— _ —_____
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: OTH: :: X BOILER • HVAC • LANDSCAPE /IRRIG: PROTECTIVE SIGNL:
GARAGE OPENER..: CLOCK INSTRUMENTATION: MEDICAL OTHR: ..
HVAC DATA /TELE COMM.: NURSE CALLS • TOTAL # SYSTEMS: 0
Owner: --------------- - ----- - --- Contractor: -- --- ---- -- - TOTAL FEES:S 5280.71
BEACON HOMES, INC BEACON HOMES This permit is subject to the regulations contained in the
9500 SW 125TH AVE 9500 SW 125TH Tigard Municipal Code, State of Ore. Specialty Codes and all
BEAVERTON OR 97008 BEAVERTON OR 97008 other applicable laws. All work will be done in accordance
with approved plans. This permit will expire if work is
Phone #: 524 -1999 Phone #: 524 -1999 not started within 180 days of issuance, or if the work is
Reg 0..: "707 suspended for more than 180 days. ATTENTION: Oregon law
----------------------- _ __- _— _________ —_ —_ requires you to follow rules adopted by the Oregon Utility
Notification Center. Those rules are set forth in OAR 952- 001 -0010. through OAR 952 - 001 -0080. You may obtain copies of these rules or
direct questions to OUNC by calling (503)246 -1987.
--------------------------------------------------------- _ REQUIRED INSPECTIONS --------------------------- w
Erosion 844 -8444 Crawl Drain /Back Electrical Rough Insulation Insp Mechanical Final
Footing Insp PL.M /Underfloor Framing Insp Rain drain Insp Plumb Final
Foundation Insp Mechanical Insp Shear Wall Insp Water Service In Building Final
Post /Beam Struct Plumb Top Out Low Voltage Appr /Sdwlk Insp
Post /Beam Meehan Electrical Servi Gas Line Insp Electrical Final
Issued By: S / Fer mittee Srgnatr_ir�e: FIVikit..
++++++++++++++++++++++++++++++++++ + + + + ++ + + + + + + + + + + + + + + + + + + + + + + + ++ + + + + + + + + + ++
Call 639 -4175 by 7:00 p.m. for an inspection needed the next bu -iness day
CITY OF TIGARD Residential Building Permit Application C h e c k
13125 SW HALL BLVD. New Construction Additions or Alterations Recd B �
Date Rec'd /b /fi
TIGARD, OR 97223 Single Family Detached or Attached (Duplex)
Date to P.E. d LO 9ef
V503- Cz 3g=41%1 /6 "b;-G(�l Date to DST / /'_, S�
F 503 - 684 -7297 c 98 - b 7- Permit # / —, 3
Print or Type 7� Called / /e`f f5
Incomplete or illegible applications will not be accepted � `-) " g
Name of Project Name
Job TIGARD WOODS PETER MAGARO ARCHITECTURE
Address S ite Address Architect Mailing Address
9879 SW. Landau P1. Lot 6 10570 SW Citation Dr.
City/State Zip Phone
Name Beaverton 97008 579 -2421
BEACON HOMES, INC. Name
Owner Mailin Address JEFF DOVE ENGINEERING
9 SW 125th Avenue Engineer Mailing Address
- City/State Zip Phone g 4914 Oakridge Rd.
Beaverton 97008 524 -1999 City/State Zip Phone
General Name Lake Oswego 97035 697 -5926
BEACON HOMES, INC.
Contractor Describe work New Addition 0 Alteration 0 Repair 0
Mailing Address to be done:
Prior to permit 9500 S W 125th Avenue Additional Description of Work:
issuance, a copy City/State Zi Phone
of all licenses Beaverton 9 524 -1999
are required if Oregon Const. Cont. Board Exp. Date PROJECT G
expired in COT Lic.# 70782 12/98 v VALUATION $
database
Mechanical Name NEW CONSTRUCTION ONLY:
Sub- MUEHE QUALITY HEATING Sq. Ft. House: Sq. Ft. Garage
yd'%
Contractor Mailing Address
2515 cRp
Prior to permit PO BOX 9 Indicate the restricted energy installation by the electrical
issuance, a copy City/State Phone subcontractor in the following areas
of all licenses West Linn 9 5 9 8 - 0 9 6 6 Restricted Audio /Stereo
are required if Oregon Const. Cont. Board Exp. Date Energy System ,Alarms
expired in COT Lic.# 50096 3/5/99 '- Installations • Irrigation
database System System
Plumbing Name (check all that Other:
Sub- CUSHMAN FAMILY PLUMBING apply)
Contractor Mailing Address
Corner O er Lot YES Flag Lot YES .[�10,
4 5 3 SE 35th Place (check one) (check one) X
Has the Subdivision Plat recorded? N/A YES NO
Prior to permit City/State Zip Phone X
issuance, a copy Portland 97202 7 7 5 - 4 4 7 2 Solar Compliance
of all licenses are Oregon Const. Cont. Board Exp. Date ✓. (Calculation Attached) •
required if Lic.# 106842 6/7/99 I h acknowledge that I have read this application, that the
expired in COT Y 9 PP
database Plumbing Lic. # Exp. Date information given is correct, that I am the owner or authorized agent
26-564 P B 6/30/99 ✓ of the owner, and that plans submitted are in compliance with
Oregon State laws. - +
Name _ Signet Owne /A e 4, p l,l q g Electrical BEAR ELECTRIC, INC. I 1. �� I
Mailing Address Contact Person Nam Phone #
Sub- PO g Box 389 � � g, K Lt lc i I`ili
Contractor FOR OFFICE USE ONLY:
City/State Zip Phone Plat #: / /ZE7//EW 1a0n/E
Prior to permit Donald, OR 9702C 678 -1355 Map/11#:
di✓ an/2�o2d� P c.�T /s / a se p - 77GQ(,
issuance, a copy
of all licenses are Oregon Const. Cont. Board Exp. Date ; Zone: Solar: /
required if Lic.# 20919 2/20/00 'V- 7 �� G '.�
expired in COT Engineering Approve : Planning Approval: TIF:
database Electrical Lic. # Exp. Date/ 73: p, /my /0/2e9e
24 -107C 10/0//99
0 /0 99 "-'
3 /6,2 s /0//o/ i/ ‘
G I:SFREM2.DOC (DST) 8/11/98
CITY OF TIGARD
13125 S.W. HALL BLVD.
TIGARD, OR 97223
IMPORTANT PERMIT NOTICE
CUSHMAN FAMILY PLUMBING
4535 SE 35TH PLACE
PORTLAND OR 97202
Plumbing Signature Form
Permit # • MST98 -0433
Date Issued.: 12/02/98
Parcel • 1S125CD -TIG06
Site Address: 09879 SW LANDAU PL
Subdivision.: TIGARD WOODS
Block Lot: 006
Zoning R -4.5
Remarks:
Path I .
Your company has been indicated as the plumbing contractor for the permit indicated above. In order
for the plumbing permit to be valid, please have the appropriate individual from your company sign
below and return this Plumbing Signature Form prior to the start of work:
No plumbing inspections will be authorized until this completed form is received.
AN INK SIGNATURE IS REQUIRED ON THIS FORM
OWNER: PLUMBING CONTRACTOR:
BEACON HOMES, INC CUSHMAN FAMILY PLUMBING
9500 SW 125THrAVE 4535 SE 35TH PLACE
BEAVERTON OR 97008 PORTLAND OR 97202
Phone #: 524 -1999 Phone #:
Reg #..: 001068
x 0
Signature of Authorized Plumber
Please return this completed form to the address above.
. ATTN: Building Dept.
If you have any questions, please call 639 -4171, ext. #310
CITY OF TIGARD
13125 S.W. HALL BLVD.
TIGARD, OR 97223
IMPORTANT PERMIT NOTICE
BEAR ELECTRIC
PO BOX 389
28085 BUTTEVILLE RD NE
DONALD OR 97020
Electrical Signature Form
Permit # • MST98 -0433
Date Issued.: 12/02/98
Parcel 1S125CD -TIG06
Site Address: 09879 SW LANDAU PL
Subdivision.: TIGARD WOODS
Block Lot: 006
Jurisdiction: TIG
Zoning R -4.5
Remarks:
Path I
Your company has been indicated as the electrical contractor for the permit indicated above. In
order for the electrical permit to be valid, the signature of the supervising electrician
is required.
Please have the appropriate individual from your company sign below and return this Electrical
Signature Form prior to the start of work to the address above, ATTN: Building Dept.
No electrical inspections will be authorized until this completed form is received.
AN INK SIGNATURE IS REQUIRED ON THIS FORM
OWNER: ELECTRICAL CONTRACTOR:
BEACON HOMES, INC BEAR ELECTRIC
9500 SW 125TH AVE PO BOX 389
BEAVERTON OR 97008 28085 BUTTEVILLE RD NE
DONALD OR 97020
Phone #: Phone #: F- 678 -1108
Reg #..: 000209
x
Signature of Supervising Electrician
If you have any questions, please call 639 -4171, ext. #310
Date Rec'd:
CITY OF TIGARD Rec'd By:
SINGLE FAMILY ATTACHED OR DETACHED (New, Addition) Plan Check #:
APPLICAl IONIPLANS SUBMITTAL REQUIREMENTS
•
Applicants: Please complete
1. APPLICANT NAME: BEACON HOMES, INC. PHONE #: 524 -1999
2. SITE ADDRESS: 9879 SW Landau P1 (lot 6) FAX # 524 -1998
1. 5 SITE PLANS (Fully dimensional, drawn to scale) labeled with:
❑ map & tax lot #, ❑ subdivision name, ❑ subdivision lot #, : - afxsite a- ddr_ess,
J( t❑ zoning,. applicant name, ❑ phone number.
Si requirement: 8 -1/2" x 11" to a maximum 11" x 17" and NOT attached to building plans.
A. North Arrow.
B,:— S.cale_(an_y_stan.dar_d., architectural or engineering only):
C. Street Names.
D. All building plans shall reflect actual building dimensions.
E. Finished floor elevations (all levels, actual topographical).
F. Garage finished floor elevation (actual topographical).
G. Cor_be.Llot_elevations (actuaLtopogr-aphical').
H . l2riveway corner elevations.
IJ Zoningsetbacks (front, side_and- rear-):
J. The location of all public and private easements.
K. The location, termination, and all invert elevations of all drainage piping (sanitary
and storm) showing all elevations necessary to show positive gravity flow to the
approved drainage device (i.e.: peepholes, storm lateral, sanitary lateral).
L. Residential driveways, sidewalks and wheelchair ramps will be shown on site
plans and will be in accordance with the CITY OF TIGARD standards. Drive -way
cuts shall not be permitted within 30 feet of intersecting right -of -way lines nor
within 5 feet of property lines. Weep holes /drain pipes will be installed 5 feet frorrr'
adjoining property lines. Multiple driveways on individual parcels of land must
have 30' of separation; joint use driveways require a formal agreement.
M. Show all erosion control devices proposed for site; refer to UNIFIED SEWERAGE
AGENCY (USA) Technical Guidance Handbook (Revised 1994), or telephone
USA at 648 -8621 for assistance.
N. Show location of existing facilities and new or relocated structures (mailboxes,
power poles, water meter, light pole, stop sign, etc...).
O. Indicate property slope directions.
P. Existing and finished contours when slope in any direction exceeds 20 %.
i:SFREQ1.DOC (dsts) 9/98
Solar Balance Point Standard Worksheet
r ce 9879 SW Landau Place
Address
Box A calculations: North -South dimension for the lot, Box A:
This dimension is determined by finding the midpoint of the North lot line and drawing
an intersecting line perpendicular to that point.
First, determine which property line is the North lot line, The North lot line is the line
with the smallest angle from a line drawn east -west and intersecting the northern most
point of the lot.
45° -
wT U w + North -South
N
Dimension for Lot:
Measure the distance from the midpoint of the North lot line to the South lot line along
the described line. I/
5O - P feet
NoRtH SOUK OmA6reACIN
Box B calculations: Shade point height for your residence. Box B:
1. Determine whether measurements will be based on the peak or cave of your Which describes
structure. The orientation of the ridge is also important. your residence?
la: If the roof line runs North - South, measurements will (circle one) �
be based on the peak of the roof. a o d tl
um I Inn
fx.vfri co+ 1B 1C
1 b: If the roof line runs East -West and the roof pitch is
less than 5/12, measurements will be based on the
IF 7
eave.
hMDE POI( DA
1c: If the roof line runs East -West and the roof pitch is yam
5/12 or steeper, measurements will be based on the o =' o
peak. t LOWY ROLE
1
Sox S. continued Box l3:
2. Measure change in elevation from front property line to finished floor elevation. If
the lot slopes up from the front lot line to the foundation, the figure is positive. if ft
the lot slopes down from the front lot line to the foundation, the figure is negative.
3. Measure distance from finished floor elevation to the affected peaWcave.
4. if the roof line runs North - South, deduct three feet. If the roof line runs East -West, ft —)
deduct nothing.
5. Subtract one foot for each foot of difference in elevation from the front property
line to the rear property line, if the lot slopes up from the front to the rear. If the
lot has no.slope or slopes up from the rear to the front, deduct nothing. - _ ft
6. Total figure for box B: 23 ft OW—
Box C. Distance to the shade reduction line. Box C:
1. Measure the distance from the North property line to the foundation near the - 5 ft
affected peak/eave.
2. Measure the distance from the foundation to the affected peak or eave. + " ft
3. Total figure for box C: lA7 ft
It is most useful to draw a vertical line to represent the appropriate figure found in box "A" and a horizontal line to represent the
appropriate figure found in box "C ". The intersection of the vertical and horizontal lines determines the value found in box "D ". The value
in box "D" should be compared to the value in box "8 "; if the value in box 1" is less than or equal to the value found in box "Q ", then
the building is in compliance with the solar balance code. If you have any questions, please contact us at 639 -4171, x304 or at the
Community Development Counter.
MAXIMUM PERMITTED SHADE POINT HEIGHT (In Feet)
Distance to North -south lot dimension (in feet)
shade 100+ 95 90 85 80 75 70 65 60 55 t9 45 40
reduction line
from northern
• •1 -
70 40 40 40 41 42 43 44
65 38 38 38 39 40 41 42 43
60 36 36 36 37 - 38 39 40 41 42
55 34 34 34 35 36 37 38 39 - 40 41
50 32 32 32 33 34 35 36 37 38 39 40
45 30 30 30 31 32 33 34 35 36 37 38 39
40 28 28 28 29 30 31 32 33 34 35 36 37 38
35 26 26 26 27 28 29 30 31 32 33 34 35 36
30 24 24 24 25 26 27 28 29 30 31 32 33 34
25 22 22 22 23 24 25 26 27 28 29 30 31 32
20 20 20 20 21 22 23 24 25 26 27 28 29 30
15 18 18 18 19 20 21 22 23 24 25 26 27 28
16 16 16 17 18 19 20 21 22 23 (C 25 26
5 14 14 14 15 16 17 18 19 20 21 22 23 24
Box D. Maximum allowed shade point height: feet p6c.
hmocs\nancy \ventura\solar.chP
Revised 2/26/96
8/20/99 Activities for Case #: MST98 -00433
3:1 8:57 PM •
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA005 Application received 10/16/98 JSD RECD DLH i 10/20/98
MSTA008 Permit Created 10/20/98 DLH DONE DLH 10/20/98
MSTA010 Check for prcl. restrict. 10/20/98 DLH DONE JSD 11/25/98 Done at post review time on
paper copy only, per BrianR. jsd
MSTA012 Plans routed to Plans Examiner 10/20/98 DLH SENT DLH 10/20/98
MSTA026 Plans approved by Pln Examiner i 10/20/98 RT PASS BT2 10/20/98
MSTA030 Reviewed plans routed to DSTS 11/24/98 RT PASS BT2 11/24/98
MSTA032 DST Post - Review Completed 11/24/98 JSD PASS JSD 11/24/98
MSTA700 Erosion 844 -8444 DLH 10/20/98
MSTA705 Footing lnsp 12/17/98 RC FAIL J *H 12/18/98 SEE LETTER IN FILE:
FOUNDATION EXCAVATIONS
FOR LOTS 5 -8 SHOULD BE
• REVIEWED BY A
GEOTECHNICAL ENGINEER
PER REPORT. HAP %jh120498
INSPECTION 121798: 1.
Carlson Report on site:
Engineering for foundation must
be approved by Plans
Examiner. 2. Bottom of footing
may not exceed 1 -in -10 slope.
3. Place forms for pads or
identify location.
MSTA706 Foundation lnsp 12/7/98 WDJ PASS J *H 12/7/98 Cannot inspect until USA is
approved and report from
geotechnical engineer is
received.
MSTA710 Post/Beam Structural 1/4/99 KS PASS KBS 1/5/99 #-1- tall crawl space approx six
ft or more no under floor
• plumbing or mechanical
installed @ this time. #-2-
lateral support post four ft high
also complete blocking as
shown tji fl system #.3-
. additional nailing @ rim joist
tomud sill #-4- min; of three
studs @ corners #-5- install low
point drain sleeve through ftg.
MSTA711 Post/Beam Mechanical 3/23/99 KS PART AKJ 3/23/99 1) Crawl drain not installed at
this time 2) Gas piping p.t. test=
22 psi for 15 min
MSTA713 Crawl Drain /Backwater valve 3/9/99 RB PART RB 3/10/99 Provide back -water valve at low
point drain. To be re- checked
at final.
MSTA717 PLM /Underfloor 3/9/99 RB PART RB 3/10/99 Low point drain req'mt. at final.
. Inspection made when.already
decked and at top -out.
Page 1 of 4
8/20/99 Activities for Case #: MST98 -00433
3:18:57 PM .
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA720 Mechanical lnsp 3/18/99 KS FAIL AKJ 3/21/99 11) Provide collar ties at comm
rafters 12) Ventilate each rafter
at vaulted ceiling 13) Provide
hangers at stair jacks 4)
. • Provide sleeve at s.s.t. gas
. tubing 15) Complete framing at
fireplace vent 16) Protect s.s.t.
gas pipe at garage
MSTA722 Plumb Top Out 3/9/99 RB FAIL RB 3/10/99 Crawl drain issue. Plumbing
under -floor issue. 1. Structural
conditions violated. To be
corrected prior to framing
inspection. 2. Mid -guide
strapping missed thru out. 3.
Jet tub access req'd prior to
final. 4. No test on DWV.
MSTA723 Electrical Service 3/2/99 CD PASS CD 3/3/99
MSTA724 Electrical Rough In 3/2/99 CD PASS CD 3/3/99
MSTA725 Framing lnsp 3/9/99 KS FAIL KBS 3/10/99 #-1- need under fl plumbing top
out also under fl mechanical
approved prior to framing
mechanical inspection]
MSTA726 Shear Wall Insp 2/2/99 RC FAIL AKJ 3/25/99 NO APP. PLANS AT SITE
MSTA728 Low Voltage DLH 10/20/98
MSTA735 Gas Line Insp 3/23/99 KS PASS AKJ 3/23/99
MSTA740 Insulation lnsp - 3/31/99 KS PART AKJ 3/31/99 1) F.S. paper touching B vent at
upper level. Need clearance
and secure f.s. paper to prevent
contact 2) OK to cover except
• for item #1 above
MSTA752 Rain drain Insp 3/3/99 MDS PASS MRS 3/3/99
MSTA761 Water Service Insp 3/3/99 MS PASS MRS 3/3/99
MSTA765 Appr /Sdwlk Insp 5/27/99 MH PASS AKJ 5/27/99 install weep hole pipe;at 2
locations, on each side of dw
MSTA790 Electrical Final 6/16/99 CD PASS AKJ 6/16/99 note: ac unit not installed at this
time
MSTA795 Mechanical Final 7/29/99 GS FAIL AKJ 7/28/99 house locked
MSTA797 Plumb Final 7/28/99 MS FAIL AKJ 7/29/99 house locked
MSTA080 (F) Ready to issue 11/24/98 JSD PASS JSD 11/24/98
MSTA092 (F) Issue combination permit 12/2/98 DLH DONE DLH 12/2/98
MSTA095 Issue plumbing signature form 12/8/98 JMT RECD JT 12/8/98
MSTA097 Issue electric signature form 12/9/98 JMT RECD JT 12/9/98
Page 2 of 4
8/20/99 Activities for Case #: MST98 -00433
3:18:57 PM
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA770 Misc. Inspection 12/8/98 CD FAIL CD 12/8/98 not ready, scheduled in error
MSTA705 Footing Insp 12/18/98 KS PASS J *H 12/21/98 Received compaction report
using T -180 w /approved
compaction per Jeff at Carlson
Testing (field report copy
attached to inspection report).
MSTA706 Foundation lnsp 12/18/98 KS PASS J *H 12/21/98 See attached engineering
provided by Dove Civil
Engineering and approved by
Plans Examiner/RDP.
FOOTING /FOUNDATION
MONO POUR INSPECTION: 1.
Monolithic f.t.g. /f.d.n 2. Initial
erosiion control (app) 3. See
compaction report (Carlson). 4.
Ufer rod (tag). 5. Install
hold -downs as shown 6. Install
anchor bolts as shown. 7. Call
for inspection (garage slab on
grade) reinforcing required
perimeter. 8. Due to cold
weather conditions protect from
freezing.
MSTA726 Shear Wall Insp 2/4/99 RC FAIL ROC 2/4/99 1. RENAIL WHERE
OVERDRIVEN 2. COMPLETE
SHEAR IN GARAGE 3. FINISH
NAILING WHERE MISSED
MSTA726 Shear Wall lnsp 2/5/99 RC PASS ROC 2/5/99 EXTERIOR SHEAR ONLY
MSTA707 Slab Insp 2/24/99 KS PASS KBS 2/25/99 #-1- slab on grade provide
protective barrier @ f font of
mechanical
MSTA722 Plumb Top Out 3/12/99 RB FAIL RB 3/15/99 1. DWV- no test. 2. Structural
conditions to be re- checked at
framing. Once approved,
plumbing issue to be resolved.
MSTA722 Plumb Top Out 3/16/99 RB PASS RB 3/17/99
•
Page3of4
8/20/99 Activities for Case #: MST98 -00433
3:18:57 PM
•
•
Assigned Hold Updated
Activity Description Date 1 Date 2 Date 3 To Done By Disp. Level By Updated Notes
MSTA725 Framing Insp 3/18/99 KS FAIL AKJ 3/21/99 1) Top flange cut at t.j.i. at
' garage 2) Add stud at >t.j.i. adj.
to elec. service 3) Provide pos.
conn. glulam to plates at
garage 4) Studs over bored at
utility rm 5) Provide full bearing
under double micro lams at din
rm also nail staggered 6)
Provide hanger at couble micro
lams 7) Provide pos. conn. post
to beam fam rm also splice at
plates 8) Pos. conn. glulam to
plates and studs above stairs 9)
Nail hanger at rafters 10)
Provide full bearing under beam
at front bedroom 11) Provide
collar ties at comm rafters 12)
Ventilate each rafter at vaulted
ceiling 13) Provide hangers at
stair jacks
MSTA725 Framing lnsp 3/25/99 RC FAIL AKJ 3/25/99 Remove insul. until framing
corrections have been insp and
approved. Reinsp fee of $15.00
MSTA780 «REINSPECTION» 3/25/99 RC PAID DST 3/25/99 framing reinsp fee Paid
re- inspection fee of $15.00,
receipt 99- 313998. Geo
MSTA725 Framing lnsp 3/30/99 KS PASS AKJ 3/30/99
MSTA740 Insulation Insp 4/1/99 KS PASS AKJ 4/1/99
MSTA799 Building Final 7/28/99 7/28/99 7/28/99 GS FAIL No Hold AKJ 7/28/99 house locked
MSTA795 Mechanical Final 7/29/99 7/29/99 7/29/99 KS FAIL No Hold AKJ 7/29/99 see bldg final 7/29/991
MSTA799 Building Final 7/29/99 . 7/29/99 7/29/99 KS FAIL No Hold AKJ 7/29/99 1) need final erosion control app
2) kitch range not functional
. 3) seal around gas pipe at ext
and other hole adj to
4) remove wood debris at crawl
recover vapor as needed
5) slope grade at crawl to low
point drain
6) provide landing at ext stairs
MSTA797 Plumb Final 7/29/99 7/29/99 7/29/99 MS PASS No Hold AKJ 7/29/99
MSTA799 Building Final 8/5/99 8/5/99 8/4/99 TLP PASS No Hold AKJ 8/5/99
MSTA795 Mechanical Final 8/5/99 8/5/99 8/4/99 TLP PASS No Hold AKJ 8/5/99
MSTA960 (F) Issue Cert. of Occupancy 8/4/99 TIG TLP DONE No Hold JMT 8/20/99
Page4of4
CITY OF TIGARD BUILDING INSPECTION DIVISION MST 97-0
24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171
BUP
Date Requested F` (4-Z p q AM PM BLD
g
Location 1 ' ' LQyP Suite MEC
Contact Person reL/ 1 / 1 Ph SZZ —gc L/ '7 PLM
Contractor Ph SWR
IL Tenant/Owner ELC
•
Retaining Wall ELR
Footing Access:
Foundation FPS
Ftg Drain SGN
Crawl Drain Inspection Notes:
Slab SIT
Post & Beam
Ext Sheath /Shear
Int Sheath /Shear
Framing
Insulation
Drywall Nailing / /�
Fire wall fr/ Jy/ ger / 7 1 L1f ��/'� ! e 1 /
Fire Sprinkler
Fire Alarm
Susp'd Ceiling
Roof
Misc:
•
PART FAIL
P". `.
Post & Beam
Under Slab
Top Out
Water Service •
Sanitary Sewer
Rain Drains
Fi t :..
ART FAIL
Tr-
Post & Beam
Rough In
Gas Line
Smoke Dampers
PART FAIL
-- CTRICAL
Service
Rough In
UG /Slab J
Low Voltage
Fire Alarm
Final
PASS PART FAIL
SITE
Backfill /Grading
Sanitary Sewer
Storm Drain 1 [ I Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd
Catch Basin [ ] Please call for reinspection RE: [ ] Unable to inspect - no access
Fire Supply Line
ADA
Approach /Sidewalk
Other Date � Inspector / an-3 Ext
Final
PASS PART FAIL DO NOT REMOVE this inspection record from the job site.