Permit CITY OF T MASTER PERMIT
PERMIT #...... o o MST97 0293
` ^ 11, 1 �� , DEVELOPMENT R SERVICES 6CES DATE ISSUED: 07/30/97
PARCEL: 25111CB —ULW03
SITE ADDRESS...:10060 SW LADY MARION DR
SUBDIVISION. ...: ULWELL I NG MLP96- -0015 ZONING: R-3.5
BLOCK.......... LOT..,o..a.,....:003 JURISDICTION: TIG
Remarks: SF - Path 1 street opening ereit required from engineering
P 9P q 9 9
----------- - ----- ------------------------ - - - - -- BUILDING —
REISSUE: STORIES • 2 FLOOR AREAS — --- BASEMENT...: 0 sf REQUIRED SETBACKS - -- REQUIRED------- ---
CLASS OF WORK.:NEW HEIGHT • 26 FIRST....: 1465 sf GARAGE • 818 sf LEFT..........: 5 SMOKE DETECTRS: Y
TYPE OF USE...:SF FLOOR LOAD : 40 SECOND...: 1406 sf FRONT • 20 PARKING SPACES: 2
TYPE OF CONST.:5N DWELLING UNITS: 1 FINBSMENT: 0 sf RIGHT.........: 5
OCCUPANCY GRP.:R3 BORN: 3 BATH: 3 TOTAL : 2871 sf VALUE..$: 206532 REAR..........: 73
SINKS • 1 WATER CLOSETS.: 3 WASHING MACH..: 1 LAUNDRY TRAYS.: 1 RAIN DRAIN ft: 100 TRAPS • 0
LAVATORIES • 4 DISHWASHERS...:. 1 FLOOR DRAINS..: 0 SEWER LINE ft: 100 SF RAIN DRAINS: 1 CATCH BASINS..: 0
TUB /SHOWERS...: 3 GARBAGE DISP..: 1 WATER HEATERS.: 1 WATER LINE ft: 100 BCKFLW PREVNTR: 1 GREASE TRAPS..: 0
OTHER FIXTURES: 0
---- ----------------------------- - - ---- MECHANICAL -- - --- - -_ ---
FUEL TYPES--- - - - - -- FURN ( 1',' ..: 0 BOIL /CMP ( 3HP: 0 VENT FANS • 4 CLOTHES DRYERS: 1
GAS FURN ) =100X ..: 1 UNIT HEATERS..: 0 HOODS.........: 1 OTHER UNITS...: 1
MAX IMP.: 0 BTU FLOOR FURNACES: B VENTS : 0 W00DSTOVES....: 0 GAS OUTLETS...: 1
- - -- -- ELECTRICAL ---- - - - - -- - -- - - --
-- RESIDENTIAL UNIT --- - -SERVICE /FEEDER ---- —TEMP SRVC /FEEDERS -- -- BRANCH CIRCUITS - -- ---- MISCELLANEA -- - -ADD'L INSPECTIONS- -
1000 SF OR LESS: 1 0 - 200 aop..: 0 0 - 200 amp..: 0 W /SVC OR FDR..: 0 PUMP /IRRIGATION: 0 PER INSPECTION: 0
EA ADD'L 500SF.: 6 201 - 400 amp..: 0 201 - 400 amp..: 0 1st W/O SVC /FDR: 0 SIGN /OUT LIN LT: 0 PER HOUR.......: 0
LIMITED ENERGY.: 0 401 - 600 aop..: 0 401 - 6 r amp..: 0 EA ADDL BR CIR: 0 SIGNAL /PANEL...: 0 IN PLANT . (11 .:
MANF HM /SVC /FDR: 0 601 - 1000 amp.: 0 601 +amps -1002 v: 0 ' MINOR LABEL -10: 0
1000+ amp /volt.: B • ------- ---- - ----- PLAN REVIEW SECTION - - - - -- --
Reconnect only.: 0 ) =4 RES UNITS..: SVC /FUR) =225 A.: ) 600 V NOMINAL: CLS AREA /SPC BCC:
--- ------------------ - - - - -- ELECTRICAL - RESTRICTED ENERGY --- — ____ --
A. SF RESIDENTIAL ----- -- - - -- B. COMMERCIAL -- ------------------ - - - - -- --- - --
AUDIO & STEREO.: VACUUM SYSTEM..: AUDIO & STEREO.: FIRE ALARM • INTERCOM /PAGING: OUTDOOR LNDSC LT:
BURGLAR ALARM..: 0TH: :: X BOILER HVAC LANDSCAPE /IRRIG: PROTECTIVE SIGNL:
GARAGE OPENER..: CLOCK • INSTRUMENTATION: MEDICAL OTHR: ..
HVAC . DATA /TELE COMM.: NURSE CALLS TOTAL # SYSTEMS: 0
Owner: --- - ----- --- - - ---- Contractor: ------------------ - - ---- TOTAL FEES:$ 4680.61
RANDALL C MYERS INC RANDALL MYERS INC This permit is subject to the regulations contained in the
6655 SW HAMPTON 4455 SW HAMPTON ST Tigard Municipal Code, State of Ore. Specialty Codes and all
PORTLAND OR 97225 STE 100 other applicable laws. All work will be done in accordance
PORTLAND OR 97223 -8358 with approved plans. This permit will expire if work is
Phone #: 598 -7565 Phone #: 639 -9054 not started within 180 days of issuance, or if the work is
Reg #..: 000489 suspended for more than 180 days. ATTENTION: Oregon law
-------- - - - - -- ------------ ---- ---- requires you to follow rules adopted by the Oregon Utility
Notification Center. Those rules are set forth in OAR 952 -001 -0010 through OAR 952- 001 -0080. You may obtain copies of these rules or
direct questions to OUNC by calling (503)246 -1987.
— °-- — -- ---- -- REQUIRED INSPECTIONS --------- - - - - -- -- -- ---- - - ----
Erosion Contol Crawl Drain Electrical Rough _ Gas Fireplace Water Se ±•_e In Building Final
Footing Insp PLM /Underfloor Franing Insp Insulation Insp Appr /Sdwl( Insp
Foundation Insp Mechanical Insp Shear Wall Insp Gyp Board Insp Electric.' . Final
Post /Beam Struct Plumb Top Out Low Voltage Rain drain Insp Mecha,rr lteina
Post /Beao Meehan Electrical Servi Gas Line Insp Water Line Insp Pludil Fink
Issued By: ___ �(�f�-- _ Per�mitt Signature:
IiiiiIIII...,
i-A- -h +A-•i t-•i- i-+ -f-- S--1- fi- -h-r- 3-• +- 1•- F- 1 -4°:- A-i-- h••i••-i-+A- •i- -FA- FA - 9--1-••1-•1-•F•- A- A- A-+A-- 1-i-- f- -:--I•-f- 1 -1 -++, '--I-- F-F -l-- 1--4--9- '- F i- +-l-A-A- -1--h
Call 639-4175 by 6 :00 p.m. for an inspection needed the ne' bussinr ss day
•
y
Plan Check 4
OF TIGARD Reside Building Permit Application
9 P P Recd By
3 25 SW HALL BLVD. New Construction Additions or Alterations Date Recd te / J
°IGARD,'OR 97223 Single Family Detached or Attached (Duplex) Date to P.E. 1 '7' .
1 503- 639 -4171 Date to DST : "' 23 7
503 -684 -7297 Permit # ' 5 1- l7V 5ta -4l—
Print or Type Called /Y71- ' c&-&161.
Incomplete or illegible applications will not be accepted .,��- `/ P"e'1
Name of Project Name -
1 ' Job .
Address ice dress Architect Mailing Address
�b � W l hA 1 1 v° ores.
Name � � City /State Zip Phone
1 0 ce ' �" i Name
M i"
caner g c c • • ) /
P//11,tjV77L P hone Engineer Mailing Address
� 7 ( s Ci /State
Came 17 , b Zip Phone
General , 49ii. C ) Describe work New 0 Addition 0 Alteration 0 Repair O
Contractor ailing Address to be done:
Additional Description of Work: -
City /State Zip Phone -
Oregon Contt o Lic.# Exdte) I r
attach Copy of ,-f e a j� 1
Currant COT Bus�gess ax or Met Exp. Date ' PROJECT
Licenses t/I ..L_ i„ �t _ VALUATION $
Na
Mechanical
S t N NEW CONSTRUCTION ONLY:
Sub- Sq. Ft Hou�/e�� e ., / Sq. Ft rage � Contractor r l iN i Comer / •
Lot YES NO Flag Lot YES . NO
city Zip Phone ( one
�j U one) (check one) • V
Oregon c ns�ont. Board Lic# E�icp. ac , •
Energy System Restricted
L.------ -Audio/Stereo ,Burglar
xach Copy of tf� � j Alarm
Licenses OT Business Tax dr Metro # Exp. Oatf ` Installation , .Garage Door -HVAC
Name �/C ° Opener Systems
-
9 IA a " l MA P- " - " 8 a p all that L Other.
Plumbin .- �"
Sub- rrin9 dress Will the electrical subcontractor wire for all YES NO
Contractor e) D(( restricted energy installations? `
0:
c s L 5/ L hQr,I_ v Has the Subdivision Plat recorded? YES NO
Oregon n �C n Board Lic.# I Exp., Date Reissue of MST# Solar Compliance
Atach Copy of C 6
Current Plumbing Lic. 4 / Exp. Date (Calculation Attached)
/ L �� I I hearty acknowledge that I have read this application, that the
Licenses -
�
information given is correct, that I am the owner or authorized
� c COT Business Tax or Metro # Exp.Se / `j
I� agent of the owner, and that plans submitted are in compliance
I'
Name with Orego State laws. , 1
Electrical • Vik CO _ Signature Owner /A a 97
w(,�.�� I 0 /47
S Ma. ing Address Contact F on
' V
4 � n ci a N m , Pelt
Contractor c < (U�JM- 'tCM K 1 L'( , bin-- r I /f`
City, tom/ Zip Phone FOR OFFICE USE ONLY: Z3 7//7'
V /" A Plat # '0 Map/TL#:
Or on Contt, C� t Board Lic.# Exp ate k 017 - 2--St 1106 `) [_13
Attach Copy of - - 111 - Setbacks: -- - Z77: - - - -- - - Solar
Sola
Current
Licenses ` L E!eatat. L ic # I Exp. Date b t I 0 1_ I �3 ,-
j t C�� Engineering Ap r ova : Planning Approval: TIF:
COT Business Tax or Metro 4 Exp.` Da �tl in y ) A� ki t t � � J rQQ1 S
: (dst) 1/97 �
1/7-51 ' 7 .
Permit # Account Description D Amount Amt. Pd, Bal. due °\
ms r1 o 2 y3 MST. Permit (BUILD) ?ad. 0 79045:g
Plumb. Permit (PLUMB) 22s — 21i
Mech. Permit = _ (MECH) 4S, `V `g'
ELC /ELR Permit ( ELPRMT) 300, '
/ 30D, —
State Tax TAX) ‘3 f 3 / �
Bldg: 3.5, v3 .
Plumb: 1/. ' V `
Mech: 2.
ELC /ELR: /3 � e° /
Plan Check
MST: (BUPPLN) $SS, 33 Z 20S; 3
Plumb: - (PLMPLN)
Mech: V (MECPLN) // Z ' ✓ it a,
- CDC Review . 0f Nt`7 'yam 0 E, �� , 0
57-o22 Sewer Connection (SWUSA) . 2Zv v / 2200
Reimbursement District ( )
Sewer Inspection SWINSP - 33 V 3 a
Parks Dev Charge (PKSDC) /DR. /0,, w
Residential TIF (TIF -R) ./60 i✓ . /‘C4 --'
Mass Transit TIE (TIF -MT) / .30 " y V %30
Water Quality (WQUAL) 2/ U , NO
:/
Water Quantity (WQUANT) 02-90 - at 9 0
Erosion Control Permit (ERPRMT) g L '/ 0
Erosion Planck/USA (ERPLAN) 0 L5 �° " � / 02e, 44
el Go i/ 44
Erosion Planck/COT (EROSN) a 02f,
Fire Life Safety (FLS) /
TOTALS: 540. V i& (73/0. $7 -I'l/APA
i:\s \ .d�97
Page No. 1 CASE HISTORY FOR CASE NO.: MST97 -0293
RANDALL C MYERS INC
• 10060 SW LADY MARION DR
12/08/98
Action Description Reg/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTA005 Application received / / / / 07/17/97 RECD JD 07/23/97 BON
MSTA008 Permit Created / / / / 07/23/97 PASS . B 07/23/97 BON
MSTA010 Check for prcl. restrict. / / / / 07/23/97 PASS B 07/23/97 BON
MSTA012 Plans routed to Plans Examiner / / / / 07/23/97 PASS B 07/23/97 BON
MSTA026 Plans approved by Pln Examiner / / / / 07/23/97 PASS RT 07/23/97 BT2
MSTA030 Reviewed plans routed to DSTS ./ / / / 07/23/97 PASS RT 07/23/97 BT2
MSTA032 DST Post- Review Completed / / / / 07/28/97 PASS JSD 07/28/97 JD
MSTA050 Hold for / / / / 07/28/98 E -MAIL TO TOM P. /HAP. NO APPROVED CRAWL 07/28/98 JT
DRAIN. TOM APPROVED PB STRUCTURAL.
HOLDING C /O. JEANNE T.
MSTA055 Hold Release to Issued / / / / 10/30/98 tom made notation that crawl was okay 10/30/98 JT
MSTA080 (F) Ready to issue / / / / 07/28/97 Need CCB and PLM for Plumber. PASS JSD 07/28/97 JD
MSTA092 (F) Issue combination permit / / / / 07/30/97 PASS B 07/30/97 BON
MSTA095 Issue plumbing signature form / / / / 08/15/97 RECD SW 08/15/97 S *W
MSTA097 Issue electric signature form / / / / 08/06/97 RECD SW 08/07/97 S *W
MSTA700 Erosion Contol / / / / / / 07/23/97 BON
MSTA705 Footing Insp / / / / 08/13/97 APP KS 08/13/97 KBS •
MSTA705 Footing Insp / / / / 08/12/97 Need initial erosion control approval FAIL KS 08/15/97 J *H
MSTA706 Foundation Insp / / / / 08/22/97 1. USA Erosion approved 081297. PASS RP 08/25/97 J *H
2. HD 8A's missed at side wall of
garage.
3. Remove all wire (holding HPAHD's and
HTT -22's at all locations), allow for
bonding.
4. HTT -22's missing at garage wing wall.
5. Extend UFER ground to a height of 12"
above mud sill height.
6. Provide adequate ventilation as per
formula: 1463 sq ft / 150 x 144/ 73 =
vent area.
7. Move vents away from holddowns, at
least 8- inches.
MSTA710 Post /Beam Structural / / /. / 09/16/97 Gusset both sides posts over 4 -feet and PASS TLP 09/19/97 J *H
solid post next to doubled 2x4's Check
at framing.
MSTA711 Post /Beam Mechanical / / / / 09/16/97 see PB Structural note PASS TLP 09/19/97 J *H
Page No. 2 CASE HISTORY FOR CASE NO.: MST97 -0293
RANDALL C MYERS INC
10060 SW LADY MARION DR
12/08/98
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTA713 Crawl Drain / / / / 09/09/97 no low point drain FAIL MS 07/28/98 DGW
/ / /MS approved final plmb 6 -17 -98 after
corrections 4 -20 -98 by WA. Must assume
that crawldrain approved hap ///
MSTA713 Crawl Drain /Backwater valve / / / / 06/17/98 entered by review of final plumbing PASS MS 07/29/98 TLP
inspection records.hap
MSTA717 PLM /Underfloor / / / / 09/16/97 req.3 " clean -out in garage PASS MS 09/16/97 MRS
MSTA720 Mechanical Insp / / / / 11/03/97 Approved as noted: PASS TLP 11/05/97 J *H
Bend the top of the bath fan exhaust
pipe so it is sticking directly into
attic vent opening.
MSTA722 Plumb Top Out / / / / 11/19/97 no test FAIL MS 11/19/97 MRS
MSTA722 Plumb Top Out / / / / 11/21/97 PASS MS 11/21/97 MRS
MSTA723 Electrical Service / / / / 11/24/97 sign and post label FAIL MJR 12/12/97 TLP
MSTA724 Electrical Rough In / / / / / / 07/23/97 BON
MSTA725 Framing Insp / / / / 11/26/97 PASS KS 12/09/97 J *H
MSTA726 Shear Wall Insp / / / / 10/24/97 Shear wall nailing approved pending PART RC 11/06/97 J *H
corrections:
1. Interior hold -downs not installed.
MSTA727 Low Voltage / / / / 06/11/98 PASS BRP 06/11/98 J *H
MSTA730 Fireplace Inap / / / / 11/03/97 Masonry inspection approved. PASS TLP 11/05/97 J *H
MSTA735 Gas Line Insp / / / / 12/19/97 no insp entered into tidemark,• contr PASS GS 12/19/97 GES
called for a re tag of gas line house
was drywalled so piping was not visible
MSTA740 Insulation Insp / / / / 12/08/97 Note: You have vents for exhaust venting FAIL TLP 12/16/97 J *H
of 1st floor laundry room and bath not
connected. Let me know if you have
visually seen that this has happened
before covering those specific areas.
MSTA740 Insulation Insp / / / / 12/09/97 Same corrections as before, connect all FAIL TLP 12/16/97 J *H
exhaust fans.
MSTA745 Gyp Board Insp / / / / 12/08/97 Same corrections as before. Connect all FAIL TLP 12/16/97 J *H
exhaust fans.
Page No. 3 CASE HISTORY FOR CASE NO.: MST97 -0293
RANDALL C MYERS INC
10060 SW LADY MARION DR
12/08/98
Action Description Reg/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
•
MSTA745 Gyp Board Insp / / / / 12/18/97 No approved plans on site to verify if FAIL KS 12/18/97 J *H
shear nailing is applicable.
MSTA745 Gyp Board Insp / / / / 12/23/97 REnail where marked PASS FS 12/23/97 RB
No gypsum shearwalls
MSTA755 Rain drain Insp / / / / 09/10/97 1. Low point drains need to be pumped to FAIL MS 09/11/97 J *H
storm sewer.
2. Rain drain needs to tie into storm
sewer in street.
MSTA755 Rain drain Insp / / / / 09/09/97 Rain drains around house only PART MS 09/13/97 J *H
MSTA755 Rain drain Insp / / / / 11/18/97 rd tied into storm sewer PASS MS 11/18/97 MRS
MSTA761 Water Service Insp / / / / 09/19/97 PASS TLP 09/21/97 J *H
MSTA765 Appr /Sdwlk Insp / / / / 02/02/98 ok to pour PASS MH 02/03/98 J *H
MSTA790 Electrical Final / / / / 06/11/98 Line voltage 120, GFCI trip 4 ma, PASS BAP 06/11/98 J *H
kitchen, 4.5 bath.
For Record: Sink counter top 1 cir.
island & wall counter 1 cir. master
bathroom - left receptacle, bottom ears
float. Center caulking may be needed to
prevent water from running into outlet
and wall. Overall a good trim out job.
Final approved. Low volt approved. No
label or address posted.
MSTA795 Mechanical Final / / / / 06/17/98 See bldg final FAIL KS 06/18/98 J *H
MSTA795 Mechanical Final 06/25/98 / / 06/19/98 PASS KS 06/25/98 J *H
MSTA797 Plumb Final / / / / 04/20/98 1. Upstairs master bath shower hot water FAIL WA 04/21/98 J *H
on wrong side; needs to be to left.
2. Cap off unused raindrain under deck
with permanent type cap.
3. No low point drain located in crawl
area.
MSTA797 Plumb Final / / / / 06/17/98 PASS MS 06/18/98 J *H
•
Page No. 4 CASE HISTORY FOR CASE NO.: MST97 -0293
RANDALL C MYERS INC
10060 SW LADY MARION DR
12/08/98
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
MSTA799 Building Final / / / / 06/17/98 1. Seal around all penetrations at FAIL KS 06/19/98 J *H
garage.
2. Insulate ducts at garage supply
return air.
3. Support gas piping at water heater
• also at furnace.
4. Insulate around door jamb at upper
storage both.
5. Relocate exhaust duct at kitchen
range (blocked) by exterior stair jack
wont open fully.
6. Provide landing at exterior stair
earth built up not adequate. •
7. Insulate exposed cap at end of heat
duct.
8.. Sump pump at crawl in lieu of low
point drain needs inspected and approved
by plumbing inspector.
9. Records show no rain drain approval.
10. Need final erosion control approval
from USA.
11. Final plumbing not approved.
MSTA799 Building Final / / / / 06/19/98 Approved subject to final grading away PASS KS 06/25/98 J *H
from structure at right side.
MSTA960 (F) Issue Cert. of Occupancy / / / / 06/19/98 12/08/98 JT
•