Loading...
Correspondence January 4, 2012 RE: TENANT IMPROVEMENT Project Information Building Permit: BUP2011 -00264 Construction Type: 2 -B Address: fp /g SW Washington Sq. Occupancy Type: M Area: 1253 Sq. Ft. Stories: 1 Name: Claires Sprinklers: Yes The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2010 edition; 2010 Oregon Fire Code. Please respond to conditions below. 1) Construction requirements for suspended ceiling systems are found in the Oregon Building Codes Division website under Statewide Code Interpretations dated 4/20/2007. (see interpretations {structural} at www.bcd.oregon.gov) 2) Provide calculations and construction details (including seismic bracing details) for all walls. Note: The roof structure may be approximately 30' above the finished floor. OSSC 106.1 3) Please provide calculations and construction details for the soffits and storefront construction. Every structure, and portion thereof, including non structural components that are permanently attached to structures and their supports and attachments, shall be designed and constructed to resist the effects of earthquake motions in accordance with ASCE 7 as modified by Section 1613.7. The seismic design category for a structure is permitted to be determined in accordance with Section 1613 or ASCE 7. OSSC 1613.1 When responding, provide an itemized letter stating in what way each numbered issue has been addressed in the revision. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, �A ,eztj 1 Dan Nelson Senior Plans Examiner (503) 718 -2436 dann @tigard - or.gov