Loading...
Correspondence s (T' 1 cT Z -076-it) 3/ E Cop y h. ciry OF T1GMD ti):EGON Thursday, May 01, 2003 Renaissance Development Curtis Heintz Excavation 1672 SW Willamette Falls Dr. 27475 SW 145' Ave. West Linn, OR 97068 Sherwood, OR 97140 Attn: Randy Sebastian, President Attn: Curtis Heintz Robert and Mary Meehl 10810 SW Kable St. Tigard, OR 97224 obert E. Vann 10722 SW Kable St. Tigard, OR 97224 Tony and Dionnie Storino 10630 SW Kable St. Tigard, OR 97224 RE: Retaining Walls on Lots # 4, 6, and 9, Erickson Heights II, 10810, 10722, and 10630 SW Kable St., Tigard. The purpose of this note is to let you know that we have received a copy of a report dated April 24, 2003, from GeoPacific Engineering on Rock Wall Evaluations for Lots 4, 6, and 9. That report includes an extensive analysis and an assessment that: "Based on our observations, explorations, assumptions, analyses, and findings, we conclude that the existing geometry and rock wall construction on Lots 4, 6, and 9, although less than a Factor -of- Safety of 1.5, is sufficient such that they do not represent a hazard to the existing residences or adjoining properties." Based on this assessment, the geometric cross - sections provided by Geopacific, and our own observations we accept the walls on Lots 4, 6, and 9 on an "as- built" basis and as requiring no further corrective action. Accordingly, we have issued a final inspection approval of those walls under permit SIT2002 -00030 for Lot #4, SIT2002 -00031 for Lot #6, and SIT2002 -00033 for Lot #9. A copy of the GeoPacific report is enclosed for the homeowners and a copy of our final inspection report is enclosed for all recipients of this letter. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Retaining Walls, Lots 4, 6, and 9. 5/1/2003; p. 2 of 2. Please note that the GeoPacific report cautions that "The homeowners should be aware that severely uncontrolled and concentrated runoff, leaking water pipes, or other sources of potential localized slope saturation may reduce portions [of] the upper wall factor -of- safety to near 1.0 and could cause partial failure of the uppermost rockery wall. We have included our list of items to consider for maintenance of hillside homesites to aid the homeowners in safeguarding against such occurrences." The "Maintenance of Hillside Homesites" list is the last page of the GeoPacific report and it includes specific references to such items as "make sure that roof rain drains are connected ... check your roof drains, gutters, and spouts to make sure that they are clear ... watch for wet spots ... do not allow water to pond on the property ... and do not irrigate in an unreasonable or excessive manner." As this list implies, it is the on -going responsibility of the respective homeowners to ensure that house rain drains and other systems are properly maintained and that neither they nor irrigation systems over - saturate the retained fill behind and beneath the rockery walls. These walls and the fill behind them are non - structural and no additional loads may be put on either that could add surcharge to the walls, such as additional fill, decks, accessory buildings, or other structures. Thank you for your cooperation in resolving the issues pertaining to the walls on this lot. Please let me know if you have any questions. Sincerely, ' I Allb■ Albert Shields Building Codes Enforcement Officer cc: Jim Imbrie, Geopacific Engineering; Property File. CITY OFTIGARD 24 -Hour BUILDING Inspection Line: (503) 639 -4175 ° INSPECTION DIVISION Busines Li : (503) 639 - 4171 MST BUP Received Date Requested v3 AM ,r PM BUP Location Z2_ 311714- — 5 S ' e �c er#6 MEC Contact Person Ph ( PLM Contractor Ph ( ) SWR BUILDING Tenant/Owner ELC Footing Foundation ELC Access: Ftg Drain ELR Crawl Drain Slab Inspection Notes: SIT 2 3O2.-00O Post & Beam Shear Anchors Ext Sheath/Shear Int Sheath/Shear Framing Insulation (/P %4 i ' i / / Drywall Nailing Firewall /2/ 3 r2y- Fire Sprinkler Fire Alarm /�� .�,5/7'L — f ' - /C Susp'd Ceiling ,, /�• C Roof i /k r✓ ,4 Other: Final �L �/�� �/' lJ /4 7 '& PASS PART FAIL PLUMBING ' 1 Post & Beam Under Slab Rough -In Water Service Sanitary Sewer Rain Drains Catch Basin / Manhole Storm Drain Shower Pan Other: • Final PASS PART FAIL MECHANICAL.... Post & Beam Rough -In Gas Line Smoke Dampers Final PASS PART FAIL • ELECTRICAL . Service Rough -In UG /Slab Low Voltage Fire Alarm Final Reinspection fee of $ required before next inspec'on. Pay at Ci .all, 13125 SW Hall Blvd. PART FAIL SITE::;; ; ;: I Please call for reinsp•ctio► RE: A Unab - o inspect – no access ' Fire ADASupply Line / / 1/ /t-2.-/4 3 Approach/Sidewalk Date inspector � //� IExt pp idewalk DO NOT REMOVE this inspection re ord from the job site. PASS PART FAIL December 31, 2002 FILE copy •- ADD Renaissance Homes, Inc. OREGON 1672 Willamette Falls Dr. West Linn, OR 97068 Re: Rockery Wall Construction with Associated Fill Dear Mr. Hunt, The rock retaining walls and associated fill for Lots 2, 4 -6 & 8 -10 have been reviewed and approved per the design by Carlson Geotechnical and your agreement with them to monitor placement of the walls and the compaction of the soils on a continuous basis. This agreement is a condition of approval of the plan review and is included as part of • the permit document package. Carlson Geotechnical shall submit daily field reports regarding drainage, wall base compaction, drainage, fill compaction, and fill slopes. At the end of construction on each lot, they must also submit a final summary report that verifies the compliance with their design and the acceptance of all supported fill at each retaining wall. This will assure the owners, developer and the City of Tigard that the terraced slope and its component elements are now and will be stable in the future. A City of Tigard Building Inspector will also make regular periodic visits once you have commenced work. Please notify Albert Shields as you begin work on each lot. His phone number is 503 - 718 -2426. The fees for these permits reflect only those pertaining to issuing each permit, and do not include any investigation or penalty fees. This will be addressed under separate cover by Albert Shields who does our uniform code enforcement. It is important to note that there is still an open enforcement case at each of these lots, and there will be no final approval by the City until those cases are resolved, and all fees paid, lot by lot or en masse. f Sincerely, SS /l� -" dpa f rx Darrel "Hap" Watkins 6 -7 I Inspection Supervisor Cc Robert Wood, Renaissance Homes, Inc. Q (0 30 Albert Shields, Codes Enforcement Officer Owners of individual properties / D‘ 0° 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 • 1 72-0 - 6 - 6v 3I L_s CITY OF TIGARD Wednesday, August 07, 2002 OREGON Homeowners at 10600, 10630, 10652, 10690, 10722, 10810, 10832, and 10856 SW Kable St, Tigard Dear Neighbors: I have spoken with some of you and have tried to reach each of you by telephone but, since many people now have unlisted numbers, just as I do, myself, I will send a copy of this note to each of you. This is to let you know that I, other inspectors from the City of Tigard, and engineers from Kleinfelder, Inc., a geotechnical engineering firm, will be taking photographs and various measurements of the rock walls and fill at the rear of each of your properties over the next few days. We plan to begin on Friday morning, August 9 about 9:00 a.m. We will not need access to your homes and we hope to be as unobtrusive as possible. Hopefully, you will not even notice that we are there and we won't inconvenience you in any way. Our sole interest is in the retaining walls that were added to the properties subsequent to the completion of the subdivision phase in December 1999, and in the composition and compaction of the fill behind those walls. The fact is that we do not have an adequate description of the size, location, and composition of those walls and fill. The purpose of our photographs and measurements will be to provide that description. • If you have any questions or if I can be of assistance in any way, please call me at 503 -639- 4171, Ext. 2426. Thank you for your cooperation. Sincerely, Albert Shields Housing Inspector, Building Codes Enforcement Officer 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772