Loading...
Plans IL E Cpl \JED , �} 1 f_ 4 ,,«;\:\,-;, GENERAL NOTES ` = � - ''?(t ,. n0.-C, 0 , 193 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OF L``.. jj3082 �+' TIr A� THE INTERNATIONAL BUILDING CODE AS AMENDED BY THE STATE OF OREGON AND ALL = l TENANT IMPROVEMENT f O O F NGa 1 VI $ �� DEFERRED O THER STATE OR LOCAL CODE REQUIREMENTS THAT APPLY. M ARTI W. HANSOM a -- - 3 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON C TX BUSINESS SOLU1I N S � DRAWINGS AND AT THE EXISTING BUILDING AND NOTIFY ARCHITECT OF ANY DISCREPANCIES Ml�rt PRIOR TO STARTING THE WORK. r f CLACKAMAS, OREGON . �' Ifecimilerni '� /,%'e > , -f •, , , Piumbhis rr 3. CONTRACTOR SHALL KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A K; O - i Eleterkal DAILY BASIS. ono 4. ALL GYPSUM BOARD TO BE A MINIMUM OF 5/8" THICK VERTICALLY ATTACHED TO 3 1/2" PROJECT #07710 Shop Dromingt OWNS METAL STUDS 24" O.C. WITH 1" TYPE S -12 SCREWS 12" O.C. UNLESS OTHERWISE NOTED. w 5. ACOUSTICAL CEILING SYSTEM IS EXISTING: TUNE UP GRID AT REMOVED WALLS AND w Other i -) REPLACE STAINED OR BROKEN TILES, F SW 's A " _ Tj 1 I•-1 C> �� T -G 6. HVAC IS EXISTING. ADJUST DUCT WORK TO NEW WALLS. -T E 1 3r 1 O - ° 1 V k r 1 : . i i 1111 ealrany Type 7. ADJUST EXISTING SPRINKLER SYSTEM PER NEW WALL CONFIGURATION. �i O ER F,c = + --r, a v blA 8. ELECTRICAL IS EXISTING. ADJUST CIRCUITRY TO NEW WALLS. SEPERATE CIRCUITS FROM OE U S H 1 • ra coNSOU ,T so r 1 o� I h` ADJACENT SPACE. '� N x a _ Energy 9. TELECOMMUNICATION SYSTEM BY TENANT. 0 O `n 4 F BU �— Accessibility p O Q N 10. PROVIDE A GASKETS WHERE WALL INTERSECTS MULLIONS OR GLAZING. ►x ,, .0 SW 74TH AVENUE z -- 11. CONTRACTOR TO CLEAN & TUNE-UP EXISTING BLINDS. — p. Z Q ,.-. co U BUILDING LOCATION 12. CONTRACTOR TO PROVIDE AND INSTALL FIRE EXTINGUISHERS AS REQUIRED PER CODE. F"' `r' O , o o Q is C _� :512` � � LL ALL DIMENSIONS ARE TO FACE OF SHEETROCK UNLESS OTHERWISE NOTED. R F21 Q LOCATION MAP TO S-2. Z SCALE -NOT TO SCALE Mr 4 PROJECT NARRATIVE z PROJECT CONSISTS OF MINOR ALTERATIONS AND FINISH WORK TO 8,175 SF OF BUILDING INFORMATION ® 0 1472547-225-0 g � ' EXISTING INTERIOR SPACE. WORK SHALL INCLUDE BUT NOT BE LIMITED TO OWNER: PACIFIC REALTY ASSOCIATES, L.P. 0 ;, — - -- - s .—? :E - — - " -" SELECTIVE DEMOLITION, DRYWALL /METAL STUDS, DOORS /FRAMES, 15350 SW SEQUOIA PKWY #300 ' ' I h O E ° o A CABINETRY FLOOR FINISHES AND PAINTING. ALL WORK TO MEET ADA PORTLAND, ORE 97224 ` . REQUIREMENTS. ' " (503) 624 -6300 (PHONE) 011 - 1 - ' ; W WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT (503) 624 -7755 (FAX) ON I ' it c./) c . N c q ei q PLUMBING WORK BLDG. #: OPBIII BLDG. B (3opb215) OR a FIRE PROTECTION SPRINKLERING �' v)ao 0 0 HEATING, VENTILATION & AIR CONDITIONING WORK CONST. TYPE.: III -B � #7W Y � �/ ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE O Z TENANT INFORMATION a w v 0 �• DRAWING INDEX TENANT: CTX BUSINESS SOLUTIONS I CITY OrTIG�ARD - H o x A -1 GENERAL INFORMATION, FINISHES, NOTES & LEGEND 0 I lL - w ,.t 51 0 P o A -2 DEMOLITION PLAN, FINISHES & NOTES OCCUPANCY AREAS & LOADS: r See Cond. �� f 3 A -3 PARTITION & POWER PLAN & NOTES B 1 SF 20 occ l Foil A-4 CEILING PLAN & NOTES S -2 6,185 SF 12 OCC REVISION A -5 DETAILS TOTAL 8,175 SF 32 OCC . ! � ' � ��r -� 1.5 � A` � r 3 . N UMBER OF EXITS REQUIRED 1 EXIT -EACH SPACE . B a ` _ , ` .An • 4 BUILDING PLAN illk z DATE: 12/6/07 NUMBER OF EXITS PROVIDED PERMIT SET 1 EXIT -EACH SPACE SCALE: 1" = 50' - 0" 11111, OFFICE COPY A -1 na t. tl OD 4/?();,, CONSTRUCTION LEGEND - - #3082 n � E XISTING TO REMAIN MARTIN W. HANSON 1 O 9 � E EXISTING TO BE REMOVED ~. .7 1 v Ci) ,- <. CLACK AS, OREGON !- NEW STANDARD LOW WALL I , DUPLEX RECEPTACLE a@, SPECIAL OUTLET 4 F, CO I I 0 ' , - - - L -- - - - - -- iii.. FOURPLEX RECEPTACLE ' TEL /DATA MUD RING WITH PULL STRING PROJECT #07710 J �M I a c L ; c D,Q DEDICATED OUTLET q ELECTRICAL PANEL I I - - Qv V EXISTING ELECTRICAL TO REMAIN ® POWER J -BOX W } I @ID1 FLOOR MONUMENT W/ SERVICES SHOWN ® FLUSH MOUNT FLOOR MONUMENT W/ POWER AND DATA p F R Iii - 1 I r I I 0 U 4t N W in i I c ; i� 2 X 4 FLUOR. FIXTURE I EXHAUST FAN Q/� 0. 1;1 I PARABOLIC LENSE 2 x 2 0 I u TILE • SPRINKLER HEAD LL I CU 2 X 4 FLUOR. FIXTURE Z r Cl. � x n SPRINKLER ���IIh���• P ARABOLIC LENSE /EMERG. EGRESS BALLAST e EXIT SIGN (LED RED) Q N a RISER 0 ((Ij HORN /STROBE FIRE ALARM 4 0 fy o N D / I _ I _ - +r RECESSED INCANDESCENT LIGHT ON RHEOSTAT (TYP.) Q I i O `p t` Q 1 SUPPLY DIFFUSER O SMOKE DETECTOR Z Z LL � - ID FIRE EXTINGUISHER IN RECESSED CAB. L . I ¢ r--, -. 14 U RETURN DUCT [ � 4 / I CA a M M OT ® FIRE EXTINGUISHER - SURFACE MOUNTED (2 p H p p w THERMOSTAT Q M !x ..--...-• LL ABBREVIATIONS a w Q I m II �I I Iil BRK BRICK PAVERS PT-# PAINT i .I 1 I ' : CP-# CUT PILE CARPET RC RUBBER BASE COVED Cl) ! I I 1..� � r I CR CHAIR RAIL RF RUBBER BASE FLAT Z E EXISTING SAT SUSPENDED ACOUSTICAL TILE O ETR EXTEND TO ROOF SC SEALED CONCRETE FWC FABRIC WALL COVERING SV SHEET VINYL [ Q 1 GT GROUT VCT WBC VINYL COMPOSITION TILE HM HOLLOW METAL WALL BOARD CEILING PGWB PAINTED GYPSUM WALL BOARD WCG WALL CORNER GUARD 0 °o 1 PL-# PLASTIC LAMINATE WD WOOD O 6 - - I PLW PLASTIC LAMINATE WAINSCOT WOC WALK OFF CARPET �j �` ,,' I Or -, T �0 I O POT PORCELAIN TILE WW WINDOW WALL a. z CI) 1 I a POTW PORCELAIN TILE WAINSCOT ¢ N cv 5 O w W a b_ Ell -� _= I PT-# PAINT II a I O :�! 0 �_- 7 W E B _ ![ - — - - - i ° �-- �-+ 4 / �� ' Y 0 v l -- = DEMOLITION NOTES O II Finishes: W Q II II II 0 MM • Z 0 1 I _ 1 _ _ PT -1 Miller Satin Latex 8772W Desert Castle G I. F-��I Z �� _ - � T � _ - -��� - - - - -- O REMOVE EXISTING PARTITIONS- SAFEOFF "3 ¢ ' \-- L !O II O O. J i 1 /O1 ELECTRICAL. PT -2 Miller Satin Latex 8733M Walnut Wash U 0 C/• H c ,. "- O II if O. Ii II II O I 2 REMOVE EXISTING RECITE OR DOOR / FRAME Carpet ¢ � H l p - f I I! I — — O -TURN OVER TO LANDLORD FOR SALVAGE / t� a. V O r a ii H STORAGE.. Cambridge, Summit 75077 Fujiyama L ` O REMOVE / RELOCATE EXISTING DOOR / FRAME. Rubber Base Johnsonite #47 Brown REVISION 1. r` O REMOVE FLOOR FINISHES THROUGHOUT VCT Armstrong Standard EXCELON 51804 Easrthstone Greige 2. INCLUDING RUBBER BASE -PATCH WALL FOR NEW RUBBER BASE INSTALLATION. LEAVE STONE TIILE AT Plastic Laminate 3. DEMOLITION PLAN SUITE ENTRY. PL -1 Hortozonial surfaces Wilsonart 4674 -60 Evening Tigris 4. PL -2 All faces and wainscot Wilsonart 1530 -60 Beige DATE: 12/6/07 SCALE: 1/8" = 1' - 0" GZ 0 REMOVE EXISTING WALL TRANSFER GRILL & INFILL OPENING. Steam clean existing ceramic tile in restrooms. PERMIT SET O REMOVE EXISTING WATER HEATERS & OLD WASHER / A -2 DRYER HOOK -UPS. _ ._. j - — - - - - - - - L' - - - - c - -_ -.7. - - _ — - *)\.\e'-'"' 411e,„?........t. ! — CONSTRUCTION NOTES 5 #3082 i MARTIN W. HANSOM 0 NEW BUILDING STANDARD LOW PARTmON TO 4T 10 RE -PAINT EXISTING WAREHOUSE (DEMISING WALL, 11 AFF W/ WOOD CAP. SEE DETAIL 3 / A -5. I DRYWALL SURFACES, TS COLUMNS, I i[ �� DOORS/FRAMES -NO CONC.) PATCH HOLES IN � CLACK / MAS, OREGON i O RELOCATED DOOR / FRAME. DRYWALL PRIOR TO PAINTING. ' 12 � � { D OORS. \ (EJSC vCT RE O INFILL EXISTING DOOR OR RECITE OPENING. 11 INSTALL INSULATION KITS AT EXISTING OVERHEAD I -- i REPAIR C � OF 0 NE W UTILITY SINK. 1 109 OF O 1 12 REMOVE & REPLACE EIXTING VERTICAL BLINDS 16 O ~ 5 UPGRADE EXISTING DUPLEX OUTLETS TO 20A. WITH BUILDING STANDARD VERTICAL BLINDS. 17 1 P ROJECT #07710 ! I 13 SECURE EXISTING STOREFRONT DOOR CLOSED _........_._._...... O I I O NEW 208V OUTLET ON DROP-CORD. i r-- PosmoN. 6 + 0 PROVIDE & INSTALL DOCK PLATE THIS DOOR. ER DOCK PLATE TO HAVE SMOOTH SURFACE (FOR 15 UPGRADE EXISTING FIRE - PROTECTION SPRINKLER O I �� � 13 �I W ROLLING STOCK). SYSTEM TO CLASS IV COMMODITY RACKED TO 1 E ELECTRICAL O O L I HIGH IN WAREHOUSE AREA. PANEL �7(� �7 � }j1 r 11 0 NEW ACCESSIBLE BREAK COUNTER /UPPERS. SEE Y Y I O [�.� y O ELEVATION 2 / A -5. CHANGE ALL ORBIT STYLE LATCHSETS TO LEVER co-- I+ M N 16 HANDLES. MATCH EXISTING FINISH. l_ N 58 W O NEW PLUMBING FIXTURES / GRAB BARS & WWITH I 1 7 P ROVIDE NEW KICK - PLATES THIS DOOR(S). 2' LDW ! O W M I O a o D 0. _I, -. 1 1 d' a - - - ACCESSORIES. SEE E 1 / A - - - - x3 T. - - - - - 1 107 1 10 - - - �— - 1114 1 -.'i w Z a . .. Z a N NOTE: ALL WALLS TO BE PAINTED PT -1 UNLESS NOTED AS ;, w i O PT -2 (ACCENT WALLS) I ice �1I .:. - CA t------- �.__ > CIRC. 106 2' I; 16 r- O vii W pM� Ezsc vcr I 1 0> d i A y � a f I ( \I /1 � � � I .1 l r ; I P T -2 i -.I En a M M WAREHOUSE I O 5 ' BREAK RE B C� F -' in Q 1 I I 1051 1104 ; 12 , p x kr) y� a , , ._, a aw Q 10 15 +45' O 6 09. 5 \ I O O „ I a C) I PT -2 i ,,� o I CID a '7I REPAIR ! A N 1,os1 V a r. 4 g w VET _ (E) 5T ENTRY 11011 O O - -- w Z O ; ! Q r-�� ,z U C7 on H VET _ LP / 16 C v o w 021E > 1 REVISION G Y I I �� � 0 1. w CC cn , 2. O Q D Q� 3. / S . __• __ _. b �� f I 4. N I 12 DATE: 12 /6/07 PARTITION AND POWER PLAN PERMIT SET SCALE 1/8" =1' - 0" j A-3 N. r I l — ---- — - - - - - _i 1 - - ) - -- OD 4l #3082 I • r (. i i 1 I CEILING NOTES I r a RE —LAMP EXISTING OFFICE LIGHTS WITHT -8 I -" i s - I ; I -� i MARTIN W. HANSON c a i' z F. c r I LAMPS ,8ALIASTS I 1 7NE5T PATH i �I \ i I 1 �, i' l ! C2 REPLACE EXISTING WAREHOUSE FIXTURES ' C 1 j it I I � C r I W ill IN EW T -5 FIXTURES. SD LIB FEET j . ' O L , ;I 4 J CL' K AS, OREGON I ■ 1 1 ' L C3 TUNE —UP EXISTING CEILING GRID — REPLACE ANY I _ r } _ 1 BROKEN OR STAINED ACOUSTICAL TILES. ; I — OF J .-'- I • r� PROJECT #07710 c2 I t_.........�j \ - I i h , r C4 REPLACE EXISTING HVAC SUPPLY &RETURN GRILL I 11 \ d — I F I ! 1 FACE— PLATES. I \ I ` i I I�._... ; .. I - - -- f ' I Ct i i j I∎ -I o �" C.) N _ J , I j { T I I w Q , D ,- O I 1-- 4.--- rr C Q I t N � I O ,r, , i I !' I? I - Otn ol -- t i ! W 1 I z , z 1 - I 11 ■m C4 _ �____1- a C2 I C4 lit ! x O 7 O� M en O� Q I ' �I n O X Ii Ct I I I c / I °u N O I� - -_ I ! II c I 1 __jJI - I - ___�I - - - - - - - Q — — — hL ' O O x I C3 �C4' ;II I � aZ I i II 4 I w W a h. � I _._.........:::_::._ I Q @ ci I I O • Z :; I ( I t I w Z�� i\ I I I r W � U ,W H , CC ( i . .._ `' � ' 1I j I U O w I I 1 ?-- - I - , — - = REVISION w 0 �w I 1 \ iI }, 1. o : \ I l® I I I 2. WOE 0_ Cr) y! l!' yI _IX U3 CC — — i 'l I i I I 3. 4. N , DATE: 12 /6/07 CEILING PLAN PERMIT SET r ® INDICATES COMMON PATH OF TRAVEL REQUIREING EMERGENCY SCALE 1/8" = 1' 0" LIGHTING EQUAL TO 1 -FOOT CANDLE. /� _ 1 (E) 1�� at *441-1D 441? 3' -1" 2' -11 1/4" 2' -11 1/4" 3/4" Cr 4N.,; 3082 S 1 WARTIN W. HANSON ,+CLACK MAS, OREGON 2 ' -6 " EXISTING (E) & VALANCE /� . ' op ot'' - , \ VALANCE I I - > i ADJ. SHELF EXISTING (E) - - / PROJECT #07710 _ (E) FLUOR LIGHT FIXT. ' \ ADJ. °PELF / N MIRROR cn 18' DEEP MICROWAVE 7 \ SHELF WIN 3' \ / N RADIUS CORNERS i ' , AND OPEN BACK ``f in x ° N - REFRIGERATOR V N W dam' i 0 WW g Q , @ ^ r _ BACK SPLASH I l a M �J • 1 N x Q ADA WALL Q V ► ' I � _ -ft---' 0 DUNG SINK e a PLAM WAINSCOT // I I O N n PLAM WAINSCOT , @ I , < ADJ SHELF >/ / / / �Q OH O A Y, Csi i , '''' -'' ■ ■ ,•• r,ld gi lg a ' EXIST. CT. BASE / 1 _ \ r _ EX IST. CT. BASE L _ Y _ ` j ~/ P. LAM. BASE / P Q �� u 11�� — F rn ,.,a o 0 1 , - � , 1 -E'" -�" 3 -I 2' -11 1/4" !r 2' -il 1/4" l 3/4" unf � � LL _ ALL BREAK ROOM APPLIANCES BY TENANT r-" a a w Q 1 REST ROOM ELEVATION - MEN 108 2 BREAK ROOM ELEVATION A -5 SCALE 3/8" = 1' - 0" WOMEN 107 OPP. HAND A - 5 SCALE 3/8" =1' - 0" Z -IC 4 4" 0 riffL((I(((I HARDWOOD CAP TO MATCH DOOR FINISH ANt RACO #FS -4B RECESSED O REVEAL HEADER � 0-1 N W w aP II g a IY 3 -5/8 MTL. STUDS @ 24" O.C. O O / / 5/8" GYP. BRD. BOTH SIDES PI Z CENTER LINE OF STUD p = z A Q l_ 25(2"x1 /4" T.S. ON (2) 1/2"4"x3/8" W H III PLATE W/ (2) 1/2" PARABOLTS MID ¢ H c N WALL AND FEE STANDING ENDS a O a ON 6' -0" O.C. (4' -0" O.C. ON TRANS. v) WALLS) REVISION / 4" RUBBER BASE -TYP. 1 2. FINISH FLOOR 4 . 4. DATE: 12/6/07 PARTIAL HT. WALL SECTION PERMIT SET �A -5 SCALE 1" = l' -0" A-5