Correspondence City of Tigard, Oregon 13125 SW Hall Blvd. m Tigard, OR 97223 :76";:
January 30, 2008 t'
• RE: TENANT IMPROVEMENT <
wT�I t ®at
Project Information V-"-'7
Building Permit: BUP2008 -00004 Construction Type: 5 -B
Address: 9225 SW Hall Blvd. Occupancy Type: M
Area: 2975 Sq. Ft. Stories: 1
The plan review was performed under the State of Oregon Structural Specialty Code
(OSSC) 2007 edition; 2007 Oregon Fire Code. Provide the following items prior to
issuance of this permit.
1) Optional suspended ceiling to be installed as per ASCE 7 or Oregon State
Interpretation.
2) All improvements made to the building shall be inspected prior to covering.
3) Make approved set of plans available for all inspections.
4) A total of 25% of the cost of the project shall go towards removing architectural
barriers (accessibility).
FIRE LIFE AND SAFETY / GENERAL
The main exterior door or doors are permitted to be equipped with key- operated locking
devices from the egress side provided:
1. The locking device is readily distinguishable as locked,
2. A readily visible durable sign is posted on the egress side on or adjacent to the
door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED.
The sign shall be in letters 1 inch (25 mm) high on a contrasting background. Sec.
1008.1.8.3
All exit doors shall be openable from the inside without the use of a key or any special
knowledge or effort. Sec. 1008.1.8
Exits and exit access doors shall be marked by an approved exit sign readily visible
from any direction of egress travel. Access
to exits shall be marked by readily visible exit signs in cases where the exit or the path
of egress travel is not immediately visible to the occupants. Sec. 1011.1
Exit signs shall be illuminated at all times and shall be provided with a second source of
power that will provide 1 1 /2 hours of illumination in case of primary power loss. Sec.
1006.3 FYI
Additional exit signs may be required by the city field inspector to clearly indicate the
path of egress.
The means of egress shall be provided with illumination of not less than 1 foot candle at
the floor level anytime the building is occupied. The means of egress illumination shall
be provided with a second source of power in case of primary power loss.
Amended Construction Documents: Work shall be installed in accordance with the
approved construction documents, and any changes made during construction that are
not in compliance with the approved construction documents shall be resubmitted for
• ,approval as an amended set of construction documents. OSSC 106.4
Phone: 503.639.4171 • Fax: 503.684.7297 0 www.tigard- or.gov ® TTY Relay: 503.684.2772
Work Commencing Before Permit Issuance: Any person who commences any work
on a building or structure before obtaining the necessary permits shall be subject to an
investigation fee equal to the permit fee that shall be in addition to the required permit
fees. OSSC 108.4
Inspections: Construction or work for which a permit is required shall be subject to
inspection by the building official and such construction or work shall remain accessible
and exposed for inspection purposes until approved. Approval as a result of an
inspection shall not be construed to be an approval of a violation of the provisions of this
code or of other laws or ordinances of the jurisdiction. Inspections presuming to give
authority to violate or cancel the provisions of this code or of other laws or ordinances of
the jurisdiction shall not be valid. OSSC 109.1
Approval Required: Work shall not be done beyond the point indicated in each
successive inspection without first obtaining the approval of the building official. The
building official, upon notification, shall make the requested inspections and shall either
indicate the portion of the construction that is satisfactory as completed, or notify the
permit holder or his or her agent wherein the same fails to comply with this code.. Any
portions that do not comply shall be corrected and such portion shall not be covered or
concealed until authorized by the building official. OSSC 109.6
Use and Occupancy: No building or structure shall be used or occupied, and no
change in the existing character, use or occupancy classification of a building or
structure or portion thereof shall be made until the building official has issued a
certificate of occupancy for such change in character, use or occupancy, therefore, as
provided herein. Issuance of a certificate of occupancy shall not be construed as an
approval of a violation of the provisions of this code or of other ordinances of the
jurisdiction. OSSC 110.1
American with Disabilities Act (ADA): It shall be the responsibility of the Architect,
Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the
ADA requirements for the structure. The City of Tigard reviews the plans and inspects
the structure only for compliance with Chapter 11 of the OSSC, which may not include
all of the requirements of the ADA.
Premises Identification: Approved numbers or addresses shall be provided for all new
buildings in such a position as to be plainly visible and legible from the street or road
fronting the property.
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp,
shall be maintained on the jobsite. The plans shall be available to the Building Division
inspectors throughout all phases of construction. (106.3.1 OSSC)
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City
of Tigard in tracking and processing the documents.
Respectfully,
an Nelson
Senior Plans Examiner
(503) 718 -2436
dann @tigard - or.gov
35O)/ 3 L po tr- x'�
57'f-'O n8''w
•
f"
( 4l g S 1-0 r e 't L .rS EA.
5Pa-c— ,906 — , 4` �5. A . aloe.
_ HANGER SPREADER . L ACE SPREADER
fo it „LES3i /)✓ 57644) (I) 0.0'X20GA STEEL STUD WI 9) (1) 35'X20GA STEEL STUD W/ Wi!!
,9 dOL•APY (W 'eGS� 2' %2 " %5' %20 GA ANGLE CLIP W/ 9BSSCREWS EA ROOF JOIST A.
(8)9 SCREWS TO (E) JOISTS ^d L I
l
� v 31=7 77 S� 3
1 ) 043 C.4 Al'_
• O (� (E)RO JOIST •i t� 3 O
I .
i i �✓ Lam)
For x .
)
N I
LATERAL BRACE SPLAY WIRES ) i )
WITH COMPRESSION STRUT _
DETAIL 9EA1H� STEPPED SOSOFFIT T- I � I ,
LOCATE EACH STEPPED PARTITION BRACE - 5' M- .VERTICALHEIGHT
CORNER AND 12' CVC MAX. 1' �_ (1) 3 5'X25GA STEEL STU / 9 MAX. B' INC W/
CO 3t1=tteeetcridhre=s4..meameerrerT-rri
1 10:1111111=1111% Is
Si
' i
. I
l I
§ 111111,
t 1 . ” GYPSUM WALLBOARD (GWB) ON ACOUSTIC PANELS IN SOFFIT BRACE: ;
a 3 DIRECT HUNG SUSPENSION SYSTEM DIRECT HUNG SUSPENSION SYSTEM (1) 1.5' COLD FORMED STEEL CHANNEL 9 MAX. 4' O/C 1 I O
m (2 A8S
)SCREWS EA END
u G LLI f c .+4 — EW PARTITION WALL J
' o C (S ♦:u /f /U) ' f— F GWB ON
^ REFER TO DETAIL IIAT FOR ADDITIONAL I 35' X 25GA STL SODS 9 2C 0/C
c6' SUSPENSION SYSTEM REQUIREMENTS C .4t,1 I I S
OJ BOTTOM TRACK W/
O 6 OX 1 S POWDER DRIVEN
_ RAMSET ANCHORS 9 24 . 0/C TO
(E) SLAB ON GRADE
\
I
, O TYP SOFFIT FRAMING O TYP PARTITION BRACING
8 1 112' F. 1 0744KE02 1 112- = 1'D' 0749E002
1:
of
Ea
P.
10 •
E
g
U .
•
arc itecture
LLP
TRANSMITTAL/ MEMO 2525 E Burnside Street
Portland, Oregon 97214
503.226.3617 phone
503.226.3715 fox
Date: January 28, 2008 www.seatlp.com
To: City of Tigard
Building Permits Dept.
13125 SW Hall Blvd.
Tigard, OR 97223
Attn: Dan Nelson
From: Kelly Edwards
Job: LaRog Jewelers - Plan Check No. BUP2008 -00004
Re: 2 ea. Revised Sets - Rev No 2 dated 1 -25 -08
1 ea. Site photos
Response to plan check:
1) Details for the suspended ceiling systems, both direct hung wallboard
and lay -in acoustic panel types, are shown on sheet A7. This detail is
also cross referenced from ceiling plan note and section target (A4) and
ceiling specifications (A1).
Note of explanation of ceiling system:
Both ceiling systems are specified with a Heavy -Duty rating per ASTM
C635 and are hung /braced per ASCE 7 -05.
The direct hung wallboard ceiling is seismically fixed to braced perimeter
walls and /or braced interior partitions. Splay bracing is required at 12' -0"
o/c and, I have added splay bracing at the corners of coffered soffits as
additional bracing.
2) Details for the interior partitions, including bracing are shown on sheet
A7. This detail is also cross referenced from floor plan wall legend (A3),
to Keynotes (A1), to details (A7).
3) Details added on sheet A7. All soffits shown on ceiling plan are the
same.
4) Added expanded code summary on sheet Al.
5) See added parking details on floor plan (A3) and site plan (A2) showing
existing HC amenities.
City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223
January 22, 2008 sa
RE: TENANT IMPROVEMENT "I CARD
sl .ard�t �s 14,: t - i
Project Information
Building Permit: BUP2008 -00004 Construction Type: 5 -B
Address: 9225 SW Hall Blvd. Occupancy Type: M
Area: 2975 Sq. Ft. Stories: 1
The plan review was performed under the State of Oregon Structural Specialty
Code (OSSC) 2007 edition; 2007 Oregon Fire Code.
1) Please provide engineered design for the grid ceiling supports,
including seismic struts. OSSC106.1
2) Please indicate on the plans which partition walls are to terminate
above the ceiling grid and which are to go to structure and show all
connection details. OSSC 106.1
3) Provide all framing (ie soffits, coves, floating ceilings) details along with
calculations.
4) Provide a complete code summary.
5) Show accessibility to the building taking into account Section 1113
OSSC.
When submitting revised drawings or additional information, please attach a copy
of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal
assists the City of Tigard in tracking and processing the documents.
Respec
l i 1 �;� `o ff ! .I
Nel on
Senior Plans Examiner
(503) 718 -2436
dann @tigard- or.gov
Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard - or.gov • TTY Relay: 503.684.2772