Specifications 1 acy's - 1st floor Drawing Date:5 -21 -08 6/26/08 16: 7 HYDRAULIC DESIGN INFORMATION SHEET OCs 44 p? ' f az 0 70 3 Job Name: Macy's - 1st floor ` ay 9 /a/ / /vd o�� Location: 9009 SW Hall Blvd. Tigard. OR Drawing Date: 5 - - Remote Area Number: 4 Contractor: SimplexGrinnell Telephone:972- 587 -5233 1125 E. Collin Blvd RECEIVED Richardson, TX Designer: J. Waldrop JUN 2 7 2008 Calculated By:SprinkCAD www.sprinkcad.com CITY OFTIGARD 451 N. Cannon Ave. BUILDING DIVISION Lansdale, PA 19446 Construction: Non - Combustible Occupancy:Ord. Gp. 2 Reviewing Authorities:City /Owner SYSTEM DESIGN Code: Hazard: System Type:WET Area of Sprinkler Oper. sq ftl Sprinkler or Nozzle Density (gpm /sq ft) 0.200 1 Make: TYCO Area per Sprinkler 120.0 sq ftl Model: TY -FRB Hose Allowance Inside 0 gpm K- Factor: 5.60 Hose Allowance Outside 0 gpm 1 Temperature Rating: 155 CALCULATION SUMMARY 10 Flowing Outlets pm Required: 510.5 psi Required: 48.9 @ Source WATER SUPPLY Water Flow Test Pump Data Date of Test 10/06 Rated Capacity 0 gpm Static Pressure 69.0 psi Rated Pressure 0.0 psi Residual Pres 60.0 psi Elevation 0 At a Flow of 1872 gpm Make: Elevation 0" Model: Location: @City Connection Source of Information: Owner SYSTEM VOLUME 468 Gallons Notes: 1st floor Rev. 2 / 06.23.08 / Change 'Area' number OFFICE COPY •Macy's - 1st floor Drawing Date:5 -21 -08 6/26/08 16: 7 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS ry DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 4 261 41.7 psi 5 4" Grvd 90 Ell 50' 120 4.026 261 1.1 1 4" Fingd Gate Valve "721U" PIV 2' 120 4.026 261 0.0 1 Pipe 4" 10x25 20' 120 4.260 261 0.3 1 8" MJ 90 Ell 18' 120 8.071 261 0.0 1 Pipe 8" DIx18 Cl 350 300' 140 8.488 261 0.1 1 8" MJ Tee 35' 120 8.071 261 0.0 1 8" Fingd Gate Valve "721U" PIV 4' 120 8.071 261 0.0 Elevation Change 12'10" 5.6 Fixed Flow Flow Loss 250 gpm Hydr Ref R1 Required at Source 511 48.9 psi Water Source 69.0 psi static, 60.0 psi residual @ 1872 gpm 511 gpm 68.2 psi SAFETY PRESSURE 19.3 psi Available Pressure of 68.2 psi Exceeds Required Pressure of 48.9 psi This is a safety margin of 19.3 psi or 28 % of Supply Maximum Water Velocity is 18.8 fps Macy's - 1st floor Drawing Date:5 -21 -08 6/26/08 16: 7 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. K FACTOR Flow factor for open head or path where Flow (gpm) = K x - \/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf /ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting na Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q /C) ^1.85 / ID ^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q ^2 /ID ^4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Macy,'s - 1st floor Drawing Date:5 -21 -08 6/26/08 16: 7 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K- FACTOR FLOW FLOW DENSITY (FT) (GPM /(PSI" )) (PSI) (GPM) (GPM) (GPM /SQ.FT) 101 13.37 30.6 101S 11.00 5.60 30.4 30.9 24.0 0.26 102 13.34 23.7 102S 11.00 5.60 23.7 27.2 24.0 0.23 103 13.35 24.2 103S 11.00 5.60 24.2 27.5 24.0 0.23 104 13.33 25.0 104S 11.00 5.60 25.0 28.0 24.0 0.23 105 13.37 26.9 105S 11.00 5.60 26.8 29.0 24.0 0.24 106 13.67 13.5 106S 11.00 5.60 14.0 20.9 17.6 0.24 107 13.17 13.3 107S 11.00 5.60 13.6 20.7 17.6 0.23 108 13.34 18.1 108S 11.00 5.60 18.4 24.0 24.0 0.20 109 13.35 20.7 109S 11.00 5.60 20.8 25.5 24.0 0.21 111 13.67 22.7 111S 11.00 5.60 22.8 26.7 24.0 0.22 120 12.83 38.1 121 12.83 33.6 122 12.83 31.2 123 12.83 30.2 124 12.83 29.6 125 12.83 33.1 126 12.83 28.6 127 12.83 25.9 128 12.83 22.9 129 12.83 17.8 130 13.17 27.3 140 13.17 16.5 Al 12.83 38.5 A2 12.83 38.5 A3 12.83 38.6 W 12.83 41.7 Max velocity of 18.76 occurs in the pipe from 125 TO 126 Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an "S" is on the branch. N1acy's - 1st floor Drawing Date:5 -21 -08 6/26/08 16: 7 Tyco Fire Products Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 107 TO W (PRIMARY PATH) 20.68 1.049 1E 2.17 13.6 13.6 K = 5.60 107S C =120 2.00 -0.9 0.0 20.68 0.138 4.17 0.6 13.6 Vel = 7.75 1.049 1T 18.08 13.3 13.3 EqK = 5.68 107 0=120 5.00 0.0 0.0 20.68 0.138 23.08 3.2 13.3 Vel = 7.75 20.94 1.049 1E 0.33 16.5 16.5 140 C =120 2.00 0.1 0.0 See PATH 2 41.62 0.505 2.33 1.2 16.5 Vel = 15.60 1.049 10.00 17.8 17.8 129 C =120 0.00 0.0 0.0 41.62 0.505 10.00 5.0 17.8 Vel = 15.60 24.00 1.380 10.00 22.9 22.9 128 C =120 0.00 0.0 0.0 See PATH 3 65.62 0.308 10.00 3.1 22.9 Vel = 14.21 25.54 1.610 9.89 25.9 25.9 127 C =120 0.00 0.0 0.0 See PATH 4 91.16 0.267 9.89 2.6 25.9 Vel = 14.51 26.73 1.610 10.51 28.6 28.6 126 C =120 0.00 0.0 0.0 See PATH 5 117.89 0.430 10.51 4.5 28.6 Vel = 18.76 2.067 iT 32.93 33.1 33.1 125 C =120 10.00 0.0 0.0 117.89 0.127 42.93 5.5 33.1 Vel = 11.38 142.65 4.260 1E 152.43 38.6 38.6 A3 C =120 1T 39.50 0.0 0.0 See PATH 6 260.54 0.016 191.93 3.1 38.6 Vel = 5.92 W 260.54 41.7 K = 40.34 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) 'Macys - 1st floor Drawing Date:5 -21 -08 6/26/08 16: 7 Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 2 FROM HYDRAULIC REFERENCE 106 TO 140 20.94 1.049 1E 2.67 14.0 14.0 K = 5.60 106S 0=120 2.00 -1.2 0.0 20.94 0.142 4.67 0.7 14.0 Vel = 7.85 1.049 1E 17.50 13.5 13.5 EqK = 5.70 106 C =120 2.00 0.2 0.0 20.94 0.142 19.50 2.8 13.5 Vel = 7.85 140 20.94 16.5 K = 5.16 PATH 3 FROM HYDRAULIC REFERENCE 108 TO 128 24.00 1.049 1E 2.34 18.4 18.4 K = 5.60 108S 0 =120 2.00 -1.0 0.0 24.00 0.182 4.34 0.8 18.4 Vel = 9.00 041/ 1.049 1E 17.51 18.1 18.1 EqK = 5.63 108 0=120 iT 7.00 0.2 0.0 24.00 0.182 24.51 4.5 18.1 Vel = 9.00 128 24.00 22.9 K = 5.02 PATH 4 FROM HYDRAULIC REFERENCE 109 TO 127 25.54 1.049 1E 2.35 20.8 20.8 K = 5.60 109S 0=120 2.00 -1.0 0.0 25.54 0.205 4.35 0.9 20.8 Vel = 9.57 1.049 1E 17.52 20.7 20.7 EqK = 5.62 109 0=120 1T 7.00 0.2 0.0 25.54 0.205 24.52 5.1 20.7 Vel = 9.57 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Nacy`s - 1st floor Drawing Date:5 -21 -08 6/26/08 16: 7 Tyco Fire Products Page 7 e. HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn 127 25.54 25.9 K = 5.01 PATH 5 FROM HYDRAULIC REFERENCE 111 TO 126 26.73 1.049 lE 2.67 22.8 22.8 K = 5.60 111S C =120 2.00 -1.2 0.0 26.73 0.223 4.67 1.0 22.8 Vel = 10.02 1.049 1E 17.50 22.7 22.7 EqK = 5.61 111 0=120 2.00 0.2 0.0 26.73 0.223 19.50 4.4 22.7 Vel = 10.02 1.049 1T 0.33 27.3 27.3 130 0=120 5.00 0.1 0.0 26.73 0.223 5.33 1.2 27.3 Vel = 10.02 126 26.73 28.6 K = 5.00 PATH 6 FROM HYDRAULIC REFERENCE 102 TO A3 27.25 1.049 1E 2.34 23.7 23.7 K = 5.60 102S C =120 2.00 -1.0 0.0 27.25 0.231 4.34 1.0 23.7 Vel = 10.21 1.049 1E 17.51 23.7 23.7 EqK = 5.60 102 0=120 1T 7.00 0.2 0.0 27.25 0.231 24.51 5.7 23.7 Vel = 10.21 1.380 10.00 29.6 29.6 124 0=120 0.00 0.0 0.0 27.25 0.061 10.00 0.6 29.6 Vel = 5.90 27.52 1.610 9.90 30.2 30.2 123 C =120 0.00 0.0 0.0 See PATH 7 54.77 0.104 9.90 1.0 30.2 Vel = 8.72 27.99 1.610 10.51 31.2 31.2 122 C =120 0.00 0.0 0.0 See PATH 8 82.76 0.224 10.51 2.3 31.2 Vel = 13.17 _TITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) 'Macy's - 1st floor Drawing Date:5 -21 -08 6/26/08 16: 7 Tyco Fire Products Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 6 FROM HYDRAULIC REFERENCE 102 TO A3 CONTINUED 29.01 2.067 1T 32.93 33.6 33.6 121 C =120 10.00 0.0 0.0 See PATH 9 111.77 0.115 42.93 5.0 33.6 Vel = 10.79 30.88 4.260 12.00 38.5 38.5 A2 C =120 0.00 0.0 0.0 See PATH 10 142.65 0.005 12.00 0.1 38.5 Vel = 3.24 A3 142.65 38.6 K = 22.97 PATH 7 FROM HYDRAULIC REFERENCE 103 TO 123 27.52 1.049 1E 2.35 24.2 24.2 K = 5.60 103S C =120 2.00 -1.0 0.0 27.52 0.235 4.35 1.0 24.2 Vel = 10.32 1.049 1E 17.52 24.2 24.2 EqK = 5.60 103 C =120 1T 7.00 0.2 0.0 27.52 0.235 24.52 5.8 24.2 Vel = 10.32 123 27.52 30.2 K = 5.01 PATH 8 FROM HYDRAULIC REFERENCE 104 TO 122 27.99 1.049 1E 2.33 25.0 25.0 K = 5.60 104S 0=120 2.00 -1.0 0.0 27.99 0.242 4.33 1.0 25.0 Vel = 10.49 1.049 1E 17.50 25.0 25.0 EqK = 5.60 104 0=120 1T 7.00 0.2 0.0 27.99 0.242 24.50 6.0 25.0 Vel = 10.49 122 27.99 31.2 K = 5.01 ITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Macy's - 1st floor Drawing Date:5 -21 -08 6/26/08 16: 7 Tyco Fire Products Page 9 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 9 FROM HYDRAULIC REFERENCE 105 TO 121 29.01 1.049 1E 2.37 26.8 26.8 K = 5.60 105S 0=120 2.00 -1.0 0.0 29.01 0.259 4.37 1.1 26.8 Vel = 10.87 1.049 lE 17.54 26.9 26.9 EqK = 5.59 105 C =120 1T 7.00 0.2 0.0 29.01 0.259 24.54 6.4 26.9 Vel = 10.87 121 29.01 33.6 K = 5.01 PATH 10 FROM HYDRAULIC REFERENCE 101 TO A2 30.88 1.049 lE 2.37 30.4 30.4 K = 5.60 1015 0=120 2.00 -1.0 0.0 30.88 0.291 4.37 1.3 30.4 Vel = 11.57 1.049 lE 17.54 30.6 30.6 EqK = 5.58 101 C =120 1T 7.00 0.2 0.0 30.88 0.291 24.54 7.2 30.6 Vel = 11.57 2.067 1T 32.93 38.1 38.1 120 C =120 10.00 0.0 0.0 30.88 0.011 42.93 0.5 38.1 Vel = 2.98 4.260 12.00 38.5 38.5 Al C =120 0.00 0.0 0.0 30.88 0.000 12.00 0.0 38.5 Vel = 0.70 A2 30.88 38.5 K = 4.98 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Water Required le Allowance s - 1st floor tatic Pressure: 69.0 psi Pressure: 48.9 psi .1e: 0 gpm SW Hall Blvd. Residual Pressure: 60.0 psi System Flow: 511 gpm Outside: 0 gpm i. OR Flow: 1872 gpm System +Hose: 511 gpm )te Area: 4 Date: 10/06 Safety Pres: 19.3 psi Loc: @City Connection Head Elev Pres: 4.8 psi Supply • 8psi 150 225 300 375 450 525 600 675 750 Clnut !piney.% Nacy's Drawing Date:Nay 14, 2008 6/10/08 15:20 HYDRAULIC DESIGN INFORMATION SHEET Job Name: Macy's Location: 9009 SW Hall Blvd Tigard, OR 97223 Drawing Date: May 14, 2008 Remote Area Number: 1 Contractor: SimplexGrinnell L.P. Telephone:972- 587 -5233 1125 E. Collins Blvd. Richardson, TX 75081 Designer: R. Timmons Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Non - Combustible Occupancy:Retail Dept Store Reviewing Authorities:Owner /Fire Marshall SYSTEM DESIGN Code:NFPA 13 Hazard:O.H. Gp2 System Type:WET Area of Sprinkler Oper. 975 sq ftl Sprinkler or Nozzle Density (gpm /sq ft) 0.200 I Make: TYCO Area per Sprinkler 120.0 sq ftl Model: TY -FRB Hose Allowance Inside 100 gpm I K- Factor: 5.60 Hose Allowance Outside 150 gpm I Temperature Rating: 155 : ALCULATION SUMMARY 10 Flowing Outlets gpm Required: 522.2 psi Required: 64.4 @ Source WATER SUPPLY Water Flow Test Pump Data Date of Test 10/06 Rated Capacity 0 gpm Static Pressure 69.0 psi Rated Pressure 0.0 psi Residual Pres 60.0 psi Elevation 0 At a Flow of 1872 gpm Make: Elevation 0" Model: Location: @ connection to 12" city main Source of Information: TV Water Co. SYSTEM VOLUME 485 Gallons Notes: AREA 1 CALCULATION: DEMONSTRATES SYSTEM ADEQUACY AT THE MOST PHYSICALLY REMOTE AREA Macy's Drawing Date:May 14, 2008 6/10/08 1.5:20 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 1 272 49.9 psi 5 4" Grvd 90 Ell 50' 120 4.026 272 1.2 1 4" Fingd Gate Valve "721U" PIV 2' 120 4.026 272 0.0 1 Pipe 4" 10x25 20' 120 4.260 272 0.4 Fixed Flow Flow Loss 100 gpm 1 8" MJ 90 Ell 18' 120 8.071 372 0.0 1 Pipe 8" DIx18 Cl 350 300' 140 8.488 372 0.2 1 8" MJ Tee 35' 120 8.071 372 0.1 1 8" Flngd Gate Valve "721U" PIV 4' 120 8.071 372 0.0 Fixed Flow Flow Loss 150 gpm Elevation Change 29'0" 12.6 Hydr Ref R1 Required at Source 522 64.4 psi Water Source 69.0 psi static, 60.0 psi residual @ 1872 gpm 522 gpm 68.2 psi SAFETY PRESSURE 3.7 psi Available Pressure of 68.2 psi Exceeds Required Pressure of 64.4 psi This is a safety margin of 3.7 psi or 5 % of Supply Maximum Water Velocity is 21.0 fps Nacy's Drawing Date:May 14, 2008 6/10/08 15:20 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. K FACTOR Flow factor for open head or path where Flow (gpm) = K x - \/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf /ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting OPe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q /C) ^1.85 / ID ^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q ^2 /ID ^4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Nacy's Drawing Date:hay 14, 2008 6/10/08 15:20 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K- FACTOR FLOW FLOW DENSITY (FT) (GPM /(PSI ^)) (PSI) (GPM) (GPM) (GPM /SQ.FT) 10 12.54 44.3 11 12.54 36.4 12 11.83 30.1 13 11.83 28.1 14 12.54 43.7 15 12.54 34.0 16 11.83 26.3 17 12.04 21.0 18 11.54 20.8 19 12.54 46.7 20 12.54 45.8 50 12.54 31.7 51 12.54 29.6 52 12.54 27.7 53 12.54 24.2 Al 12.54 46.7 A2 12.54 46.8 A3 12.54 46.9 A4 12.54 48.6 A5 12.54 48.8 A6 12.54 49.3 A7 12.54 49.9 oft S1 13.04 22.4 S1S 11.00 5.60 22.4 26.5 24.0 0.22 S2 11.83 24.1 S2S 11.00 5.60 23.8 27.3 24.0 0.23 S3 11.83 25.9 S3S 11.00 5.60 25.6 28.3 24.0 0.24 S4 13.06 29.3 S4S 11.00 5.60 29.1 30.2 24.0 0.25 S5 13.04 18.2 S5S 11.00 5.60 18.4 24.0 24.0 0.20 S6 12.04 17.2 S6S 11.00 5.60 17.2 23.2 14.8 0.39 S7 11.54 17.2 S7S 11.00 5.60 17.0 23.1 14.8 0.38 S8 11.83 22.6 S8S 11.00 5.60 22.3 26.5 24.0 0.22 S9 13.06 27.3 S9S 11.00 5.60 27.2 29.2 24.0 0.24 S10 13.06 37.1 SlOS 11.00 5.60 36.6 33.9 24.0 0.28 W 12.54 49.9 Max velocity of 20.95 occurs in the pipe from 15 TO 52 Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an "S" is on the branch. Nacy's Drawing Date:Nay 14, 2008 6/10/08 15:20 Tyco Fire Products Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE S7 TO W (PRIMARY PATH) 23.07 1.049 lE 0.54 17.0 17.0 K = 5.60 S7S C =120 2.00 -0.2 0.0 23.07 0.169 2.54 0.4 17.0 Vel = 8.65 1.049 1E 19.54 17.2 17.2 EqK = 5.57 S7 C =120 2.00 0.0 0.0 23.07 0.169 21.54 3.7 17.2 Vel = 8.65 1.049 1E 0.50 20.8 20.8 18 C =120 2.00 -0.2 0.0 23.07 0.169 2.50 0.4 20.8 Vel = 8.65 23.21 1.049 1T 0.50 21.0 21.0 17 C =120 5.00 -0.2 0.0 See PATH 2 46.28 0.614 5.50 3.4 21.0 Vel = 17.35 24.00 1.380 10.00 24.2 24.2 53 C =120 0.00 0.0 0.0 See PATH 3 70.28 0.350 10.00 3.5 24.2 Vel = 15.22 26.46 1.380 10.00 27.7 27.7 52 C =120 0.00 0.0 0.0 See PATH 4 96.74 0.632 10.00 6.3 27.7 Vel = 20.95 29.19 1.610 20.00 34.0 34.0 15 C =120 0.00 0.0 0.0 See PATH 8 125.93 0.486 20.00 9.7 34.0 Vel = 20.04 2.067 1T 11.00 43.7 43.7 14 0=120 10.00 0.0 0.0 125.93 0.144 21.00 3.0 43.7 Vel = 12.16 112.36 4.260 12.00 46.8 46.8 A2 C =120 0.00 0.0 0.0 See PATH 5 238.29 0.014 12.00 0.2 46.8 Vel = 5.42 33.87 4.260 96.00 46.9 46.9 A3 C =120 0.00 0.0 0.0 See PATH 10 272.16 0.018 96.00 1.7 46.9 Vel = 6.19 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Nacy's Drawing Date:Nay 14, 2008 6/10/08 15:20 Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE S7 TO W (PRIMARY PATH) 4.260 12.00 48.6 48.6 A4 C =120 0.00 0.0 0.0 272.16 0.018 12.00 0.2 48.6 Vel = 6.19 4.260 24.00 48.8 48.8 A5 C =120 0.00 0.0 0.0 272.16 0.018 24.00 0.4 48.8 Vel = 6.19 4.260 iT 8.31 49.3 49.3 A6 C =120 26.33 0.0 0.0 272.16 0.018 34.64 0.6 49.3 Vel = 6.19 4.260 3.45 49.9 49.9 A7 C =120 0.00 0.0 0.0 272.16 0.018 3.45 0.1 49.9 Vel = 6.19 W 272.16 49.9 K = 38.51 PATH 2 FROM HYDRAULIC REFERENCE S6 TO 17 23.21 1.049 1E 1.04 17.2 17.2 K = 5.60 S6S C =120 2.00 -0.5 0.0 23.21 0.171 3.04 0.5 17.2 Vel = 8.70 1.049 1T 17.00 17.2 17.2 EqK = 5.59 S6 C =120 5.00 0.0 0.0 23.21 0.171 22.00 3.8 17.2 Vel = 8.70 17 23.21 21.0 K = 5.06 PATH 3 FROM HYDRAULIC REFERENCE S5 TO 53 24.00 1.049 1E 2.04 18.4 18.4 K = 5.60 S5S C =120 2.00 -0.9 0.0 24.00 0.182 4.04 0.7 18.4 Vel = 9.00 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Nacy's Drawing Date:hay 14, 2008 6/10/08 15:20 Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 3 FROM HYDRAULIC REFERENCE S5 TO 53 CONTINUED 1.049 2E 27.50 18.2 18.2 EqK = 5.62 S5 C =120 4.00 0.2 0.0 24.00 0.182 31.50 5.8 18.2 Vel = 9.00 53 24.00 24.2 K = 4.88 PATH 4 FROM HYDRAULIC REFERENCE S8 TO 52 26.46 1.049 1E 0.83 22.3 22.3 K = 5.60 S8S C =120 2.00 -0.4 0.0 26.46 0.218 2.83 0.6 22.3 Vel = 9.92 1.049 17.00 22.6 22.6 EqK = 5.57 S8 C =120 0.00 0.0 0.0 26.46 0.218 17.00 3.7 22.6 Vel = 9.92 MD 1.049 1E 0.71 26.3 26.3 16 0=120 1T 7.00 -0.3 0.0 26.46 0.218 7.71 1.7 26.3 Vel = 9.92 52 26.46 27.7 K = 5.03 PATH 5 FROM HYDRAULIC REFERENCE S1 TO A2 26.52 1.049 1E 2.04 22.4 22.4 K = 5.60 S1S C =120 2.00 -0.9 0.0 26.52 0.219 4.04 0.9 22.4 Vel = 9.94 1.049 2E 27.50 22.4 22.4 EqK = 5.60 S1 C =120 4.00 0.2 0.0 26.52 0.219 31.50 6.9 22.4 Vel = 9.94 27.34 1.380 10.00 29.6 29.6 51 C =120 0.00 0.0 0.0 See PATH 6 53.86 0.214 10.00 2.1 29.6 Vel = 11.67 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) N.acy's Drawing Date:Nay 14, 2008 6/10/08 15:20 Tyco Fire Products Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 5 FROM HYDRAULIC REFERENCE S1 TO A2 CONTINUED 28.31 1.380 10.00 31.7 31.7 50 C =120 0.00 0.0 0.0 See PATH 7 82.17 0.467 10.00 4.7 31.7 Vel = 17.80 30.19 1.610 20.00 36.4 36.4 11 C =120 0.00 0.0 0.0 See PATH 9 112.36 0.394 20.00 7.9 36.4 Vel = 17.88 2.067 1T 11.00 44.3 44.3 10 0=120 10.00 0.0 0.0 112.36 0.117 21.00 2.4 44.3 Vel = 10.85 4.260 12.00 46.7 46.7 Al C =120 0.00 0.0 0.0 112.36 0.003 12.00 0.0 46.7 Vel = 2.55 A2 112.36 46.8 K = 16.43 PATH 6 FROM HYDRAULIC REFERENCE S2 TO 51 27.34 1.049 1E 0.83 23.8 23.8 K = 5.60 S2S C =120 2.00 -0.4 0.0 27.34 0.232 2.83 0.7 23.8 Vel = 10.25 1.049 17.00 24.1 24.1 EqK = 5.57 S2 C =120 0.00 0.0 0.0 27.34 0.232 17.00 4.0 24.1 Vel = 10.25 1.049 1E 0.71 28.1 28.1 13 0=120 1T 7.00 -0.3 0.0 27.34 0.232 7.71 1.8 28.1 Vel = 10.25 51 27.34 29.6 K = 5.03 PATH 7 FROM HYDRAULIC REFERENCE S3 TO 50 28.31 1.049 1E 0.83 25.6 25.6 K = 5.60 S3S C =120 2.00 -0.4 0.0 28.31 0.247 2.83 0.7 25.6 Vel = 10.61 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Macy's Drawing Date:May 14, 2008 6/10/08 15:20 Tyco Fire Products Page 9 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 7 FROM HYDRAULIC REFERENCE S3 TO 50 CONTINUED 1.049 17.00 25.9 25.9 EqK = 5.56 S3 C =120 0.00 0.0 0.0 28.31 0.247 17.00 4.2 25.9 Vel = 10.61 1.049 1E 0.71 30.1 30.1 12 0=120 1T 7.00 -0.3 0.0 28.31 0.247 7.71 1.9 30.1 Vel = 10.61 50 28.31 31.7 K = 5.02 PATH 8 FROM HYDRAULIC REFERENCE S9 TO 15 29.19 1.049 1E 2.06 27.2 27.2 K = 5.60 S9S C =120 2.00 -0.9 0.0 29.19 0.262 4.06 1.1 27.2 Vel = 10.94 1.049 1E 17.52 27.3 27.3 EqK = 5.58 S9 C =120 1T 7.00 0.2 0.0 29.19 0.262 24.52 6.5 27.3 Vel = 10.94 15 29.19 34.0 K = 5.00 PATH 9 FROM HYDRAULIC REFERENCE S4 TO 11 30.19 1.049 lE 2.06 29.1 29.1 K = 5.60 S4S C =120 2.00 -0.9 0.0 30.19 0.279 4.06 1.1 29.1 Vel = 11.32 1.049 1E 17.52 29.3 29.3 EqK = 5.58 S4 C =120 1T 7.00 0.2 0.0 30.19 0.279 24.52 6.9 29.3 Vel = 11.32 11 30.19 36.4 K = 5.00 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Nacy's Drawing Date:Nay 14, 2008 6/10/08 15:20 Tyco Fire Products Page 10 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 10 FROM HYDRAULIC REFERENCE S10 TO A3 33.87 1.049 1E 2.06 36.6 36.6 K = 5.60 SlOS C =120 2.00 -0.9 0.0 33.87 0.345 4.06 1.4 36.6 Vel = 12.70 1.049 1E 17.52 37.1 37.1 EqK = 5.56 S10 0=120 1T 7.00 0.2 0.0 33.87 0.345 24.52 8.5 37.1 Vel = 12.70 1.610 20.00 45.8 45.8 20 C =120 0.00 0.0 0.0 33.87 0.043 20.00 0.9 45.8 Vel = 5.39 2.067 1T 11.00 46.7 46.7 19 0=120 10.00 0.0 0.0 33.87 0.013 21.00 0.3 46.7 Vel = 3.27 A3 33.87 46.9 K = 4.94 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Job Water Required Hose Allowance Macy's Static Pressure: 69.0 psi Pressure: 64.4 Inside: 100 gpm 9009 SW Hall Blvd Residual Pressure: 60.0 psi System Flow: 272 gpm Outside: 150 gpm Tigard, OR 97223 Flow: 1872 gpm System +Hose: 522 gpm Remote Area: 1 Date: 10/06 Safety Pres: 3.7 psi Loc: @ connection to 12" city Head Elev Pres: 11.9 psi 70� Suppl O 250 gpm hose 60 - - 50 40 30 - 20 - 11.9 psi 10 150 225 300 375 450 525 600 675 750 Flow (gpm) Macy's Drawing Date:May 14, 2008 6/10/08 15:40 HYDRAULIC DESIGN INFORMATION SHEET Job Name: Macy's Location: 9009 SW Hall Blvd Tigard, OR 97223 Drawing Date: May 14, 2008 Remote Area Number: 2 Contractor: SimplexGrinnell L.P. Telephone:972- 587 -5233 1125 E. Collins Blvd. Richardson, TX 75081 Designer: R. Timmons Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Non - Combustible Occupancy:Retail Dept Store Reviewing Authorities:Owner /Fire Marshall SYSTEM DESIGN Code:NFPA 13 Hazard:O.H.Gp 2 System Type:WET Area of Sprinkler Oper. 975 sq ftl Sprinkler or Nozzle Density (gpm /sq ft) 0.200 I Make: TYCO Area per Sprinkler 126.0 sq ftl Model: TY -FRB Hose Allowance Inside 100 gpm I K- Factor: 5.60 Hose Allowance Outside 150 gpm I Temperature Rating: 155 CALCULATION SUMMARY 13 Flowing Outlets gpm Required: 593.9 psi Required: 67.5 @ Source WATER SUPPLY Water Flow Test Pump Data Date of Test 10/06 Rated Capacity 0 gpm Static Pressure 69.0 psi Rated Pressure 0.0 psi Residual Pres 60.0 psi Elevation 0 At a Flow of 1872 gpm Make: Elevation 0" Model: Location: @ connection to 12" city main Source of Information: TV Water Co. SYSTEM VOLUME 485 Gallons Notes: AREA 2: CALCULATION: DEMONSTRATES SYSTEM ADEQUACY FOR BLINES WITH MULTIPLE 2 HEAD OUTLETS Macy's Drawing Date:Nay 14, 2008 6/10/08 15:40 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 2 344 52.0 psi 5 4" Grvd 90 Ell 50' 120 4.026 344 1.9 1 4" Flngd Gate Valve "721U" PIV 2' 120 4.026 344 0.1 1 Pipe 4" 10x25 20' 120 4.260 344 0.5 Fixed Flow Flow Loss 100 gpm 1 8" MJ 90 Ell 18' 120 8.071 444 0.0 1 Pipe 8" DIx18 Cl 350 300' 140 8.488 444 0.3 1 8" MJ Tee 35' 120 8.071 444 0.1 1 8" Flngd Gate Valve "721U" PIV 4' 120 8.071 444 0.0 Fixed Flow Flow Loss 150 gpm Elevation Change 29'0" 12.6 Hydr Ref R1 Required at Source 594 67.5 psi Water Source 69.0 psi static, 60.0 psi residual @ 1872 gpm 594 gpm 67.9 psi SAFETY PRESSURE 0.4 psi Available Pressure of 67.9 psi Exceeds Required Pressure of 67.5 psi This is a safety margin of 0.4 psi or 1 % of Supply Maximum Water Velocity is 23.1 fps Macy's Drawing Date:Nay 14, 2008 6/10/08 15:40 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. _ K FACTOR Flow factor for open head or path where Flow (gpm) = K x - \/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf /ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting ?e Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q /C) ^1.85 / ID ^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q ^2 /ID ^4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Nacy's Drawing Date:hay 14, 2008 6/10/08 15:40 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K- FACTOR FLOW FLOW DENSITY (FT) (GPM /(PSI ^)) (PSI) (GPM) (GPM) (GPM /SQ.FT) 28 11.83 29.4 29 11.83 30.4 30 11.83 26.0 32 13.15 40.1 33 13.15 32.4 34 13.15 27.5 35 13.15 26.3 39 11.83 36.2 40 11.83 29.8 41 12.54 27.1 42 11.54 20.4 60 12.54 49.3 61 12.54 42.2 62 12.54 34.7 63 12.54 32.0 64 12.54 48.6 65 12.54 38.1 66 12.54 31.4 67 12.04 20.6 A4 12.54 51.4 AS 12.54 51.5 A6 12.54 51.6 A7 12.54 51.9 B2 12.54 51.2 B3 12.54 51.2 B4 12.54 51.3 D1 12.54 51.8 S21 11.54 17.4 S21S 9.50 5.60 17.6 23.5 14.8 0.35 S22 12.04 16.0 S22S 9.50 5.60 16.4 22.7 16.6 0.27 S23 13.05 21.6 S23S 9.50 5.60 22.0 26.2 14.8 0.39 S24 11.83 24.7 S24S 9.50 5.60 24.7 27.8 25.2 0.22 S25 11.83 30.4 S25S 9.50 5.60 30.1 30.7 25.2 0.24 S26 13.04 24.5 S26S 9.50 5.60 24.7 27.9 14.8 0.39 S27 11.83 25.5 S27S 9.50 5.60 25.4 28.2 14.8 0.47 S28 11.83 20.1 S28S 9.50 5.60 20.2 25.2 25.2 0.20 S29 11.83 20.1 S29S 9.50 5.60 20.3 25.2 25.2 0.20 S30 13.15 20.8 S3OS 9.50 5.60 21.2 25.8 14.8 0.36 S31 13.15 21.5 S31S 9.50 5.60 21.9 26.2 24.0 0.22 S32 13.15 22.5 S32S 9.50 5.60 22.9 26.8 25.2 0.21 Macy's Drawing Date:May 14, 2008 6/10/08 15:40 Page 5 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K- FACTOR FLOW FLOW DENSITY (FT) (GPM /(PSI^)) (PSI) (GPM) (GPM) (GPM /SQ.FT) S33 13.15 24.2 S33S 9.50 5.60 24.4 27.7 25.2 0.22 W 12.54 52.0 Max velocity of 23.07 occurs in the pipe from 61 TO 62 Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an "S" is on the branch. Nacy's Drawing Date:May 14, 2008 6/10/08 15:40 Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE S22 TO W (PRIMARY PATH) 22.66 1.049 1E 2.54 16.4 16.4 K = 5.60 S22S 0 =120 2.00 -1.1 0.0 22.66 0.164 4.54 0.7 16.4 Vel = 8.49 1.049 1E 20.90 16.0 16.0 EqK = 5.66 S22 0 =120 1T 7.00 0.0 0.0 22.66 0.164 27.90 4.6 16.0 Vel = 8.49 23.47 1.049 1E 9.04 20.6 20.6 67 C =120 2.00 -0.2 0.0 See PATH 2 46.13 0.611 11.04 6.7 20.6 Vel = 17.29 26.24 1.380 11.46 27.1 27.1 41 0 =120 0.00 0.0 0.0 See PATH 7 72.36 0.369 11.46 4.2 27.1 Vel = 15.67 27.84 1.380 10.00 31.4 31.4 66 C =120 0.00 0.0 0.0 See PATH 10 100.20 0.675 10.00 6.7 31.4 Vel = 21.70 30.74 1.610 20.00 38.1 38.1 65 C =120 0.00 0.0 0.0 See PATH 13 130.95 0.522 20.00 10.4 38.1 Vel = 20.84 2.067 iT 11.00 48.6 48.6 64 0=120 10.00 0.0 0.0 130.95 0.155 21.00 3.2 48.6 Vel = 12.64 4.260 1T 3.69 51.8 51.8 D1 C =120 26.33 0.0 0.0 130.95 0.005 30.03 0.1 51.8 Vel = 2.98 212.92 4.260 3.45 51.9 51.9 A7 C =120 0.00 0.0 0.0 See PATH 3 343.87 0.027 3.45 0.1 51.9 Vel = 7.82 W 343.87 52.0 K = 47.67 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Macy's Drawing Date:May 14, 2008 6/10/08 15:40 Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 2 FROM HYDRAULIC REFERENCE S21 TO 67 23.47 1.049 lE 2.04 17.6 17.6 K = 5.60 S21S C =120 2.00 -0.9 0.0 23.47 0.175 4.04 0.7 17.6 Vel = 8.80 1.049 17.00 17.4 17.4 EqK = 5.63 S21 C =120 0.00 0.0 0.0 23.47 0.175 17.00 3.0 17.4 Vel = 8.80 1.049 1E 0.50 20.4 20.4 42 C =120 2.00 -0.2 0.0 23.47 0.175 2.50 0.4 20.4 Vel = 8.80 67 23.47 20.6 K = 5.17 PATH 3 FROM HYDRAULIC REFERENCE S28 TO A7 25.20 1.049 1E 2.33 20.2 20.2 K = 5.60 S28S C =120 2.00 -1.0 0.0 25.20 0.200 4.33 0.9 20.2 Vel = 9.45 1.049 1E 22.54 20.1 20.1 EqK = 5.62 S28 0=120 1T 7.00 0.0 0.0 25.20 0.200 29.54 5.9 20.1 Vel = 9.45 25.21 1.049 4.73 26.0 26.0 30 C =120 0.00 0.0 0.0 See PATH 4 50.41 0.720 4.73 3.4 26.0 Vel = 18.90 1.049 1E 0.71 29.4 29.4 28 0=120 1T 7.00 -0.3 0.0 50.41 0.720 7.71 5.5 29.4 Vel = 18.90 56.09 1.380 10.00 34.7 34.7 62 C =120 0.00 0.0 0.0 See PATH 11 106.49 0.755 10.00 7.6 34.7 Vel = 23.07 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Macy's Drawing Date:May 14, 2008 6/10/08 15:40 Tyco Fire Products Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 3 FROM HYDRAULIC REFERENCE S28 TO A7 CONTINUED 1.610 20.00 42.2 42.2 61 C =120 0.00 0.0 0.0 106.49 0.356 20.00 7.1 42.2 Vel = 16.95 2.067 1T 11.00 49.3 49.3 60 0=120 10.00 0.0 0.0 106.49 0.106 21.00 2.2 49.3 Vel = 10.28 106.43 4.260 1T 8.31 51.6 51.6 A6 C =120 26.33 0.0 0.0 See PATH 5 212.92 0.011 34.64 0.4 51.6 Vel = 4.84 A7 212.92 51.9 K = 29.54 PATH 4 FROM HYDRAULIC REFERENCE 529 TO 30 25.21 1.049 1E 2.33 20.3 20.3 K = 5.60 S29S C =120 2.00 -1.0 0.0 25.21 0.200 4.33 0.9 20.3 Vel = 9.45 1.049 1E 22.46 20.1 20.1 EqK = 5.62 S29 0=120 1T 7.00 0.0 0.0 25.21 0.200 29.46 5.9 20.1 Vel = 9.45 30 25.21 26.0 K = 4.94 PATH 5 FROM HYDRAULIC REFERENCE S30 TO A6 25.80 1.049 lE 3.65 21.2 21.2 K = 5.60 S30S C =120 2.00 -1.6 0.0 25.80 0.208 5.65 1.2 21.2 Vel = 9.67 1.049 1E 23.94 20.8 20.8 EqK = 5.65 S30 C =120 2.00 0.0 0.0 25.80 0.208 25.94 5.4 20.8 Vel = 9.67 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Nacy's Drawing Date:Nay 14, 2008 6/10/08 15:40 Tyco Fire Products Page 9 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 5 FROM HYDRAULIC REFERENCE S30 TO A6 CONTINUED 26.19 1.380 6.17 26.3 26.3 35 C =120 0.00 0.0 0.0 See PATH 6 51.99 0.200 6.17 1.2 26.3 Vel = 11.26 26.78 1.380 1T 5.39 27.5 27.5 34 C =120 6.00 0.0 0.0 See PATH 8 78.76 0.432 11.39 4.9 27.5 Vel = 17.06 27.67 1.610 21.68 32.4 32.4 33 C =120 0.00 0.0 0.0 See PATH 9 106.43 0.356 21.68 7.7 32.4 Vel = 16.94 1.610 2E 14.23 40.1 40.1 32 0=120 iT 16.00 0.3 0.0 106.43 0.356 30.23 10.8 40.1 Vel = 16.94 4.260 1T 2.00 51.2 51.2 B2 C =120 26.33 0.0 0.0 106.43 0.003 28.33 0.1 51.2 Vel = 2.42 4.260 8.50 51.2 51.2 B3 C =120 0.00 0.0 0.0 106.43 0.003 8.50 0.0 51.2 Vel = 2.42 4.260 1T 31.00 51.3 51.3 B4 C =120 26.33 0.0 0.0 106.43 0.003 57.33 0.2 51.3 Vel = 2.42 4.260 12.00 51.4 51.4 A4 C =120 0.00 0.0 0.0 106.43 0.003 12.00 0.0 51.4 Vel = 2.42 4.260 24.00 51.5 51.5 A5 C =120 0.00 0.0 0.0 106.43 0.003 24.00 0.1 51.5 Vel = 2.42 A6 106.43 51.6 K = 14.82 PATH 6 FROM HYDRAULIC REFERENCE S31 TO 35 26.19 1.049 1E 3.65 21.9 21.9 K = 5.60 S31S C =120 2.00 -1.6 0.0 26.19 0.214 5.65 1.2 21.9 Vel = 9.82 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Macy's Drawing Date:May 14, 2008 6/10/08 15:40 Tyco Fire Products Page 10 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 6 FROM HYDRAULIC REFERENCE S31 TO 35 CONTINUED 1.049 1T 17.00 21.5 21.5 EqK = 5.65 S31 C =120 5.00 0.0 0.0 26.19 0.214 22.00 4.8 21.5 Vel = 9.82 35 26.19 26.3 K = 5.11 PATH 7 FROM HYDRAULIC REFERENCE S23 TO 41 26.24 1.049 1E 3.55 22.0 22.0 K = 5.60 S23S C =120 2.00 -1.5 0.0 26.24 0.215 5.55 1.2 22.0 Vel = 9.84 1.049 1E 17.51 21.6 21.6 EqK = 5.64 S23 0=120 1T 7.00 0.2 0.0 26.24 0.215 24.51 5.3 21.6 Vel = 9.84 41 26.24 27.1 K = 5.04 PATH 8 FROM HYDRAULIC REFERENCE S32 TO 34 26.78 1.049 1E 3.65 22.9 22.9 K = 5.60 S32S C =120 2.00 -1.6 0.0 26.78 0.223 5.65 1.3 22.9 Vel = 10.04 1.049 iT 17.00 22.5 22.5 EqK = 5.64 S32 C =120 5.00 0.0 0.0 26.78 0.223 22.00 5.0 22.5 Vel = 10.04 34 26.78 27.5 K = 5.11 PATH 9 FROM HYDRAULIC REFERENCE S33 TO 33 27.67 1.049 1E 3.65 24.4 24.4 K = 5.60 S33S C =120 2.00 -1.6 0.0 27.67 0.237 5.65 1.3 24.4 Vel = 10.37 JNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Macy's Drawing Date:May 14, 2008 6/10/08 15:40 Tyco Fire Products Page 11 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 9 FROM HYDRAULIC REFERENCE S33 TO 33 CONTINUED 1.049 2T 24.61 24.2 24.2 EqK = 5.63 S33 0=120 10.00 0.0 0.0 27.67 0.237 34.61 8.2 24.2 Vel = 10.37 33 27.67 32.4 K = 4.86 PATH 10 FROM HYDRAULIC REFERENCE S24 TO 66 27.84 1.049 1E 2.33 24.7 24.7 K = 5.60 S24S C =120 2.00 -1.0 0.0 27.84 0.240 4.33 1.0 24.7 Vel = 10.44 1.049 1E 19.08 24.7 24.7 EqK = 5.60 S24 C =120 2.00 0.0 0.0 27.84 0.240 21.08 5.1 24.7 Vel = 10.44 1.049 1E 0.71 29.8 29.8 40 0=120 1T 7.00 -0.3 0.0 27.84 0.240 7.71 1.8 29.8 Vel = 10.44 66 27.84 31.4 K = 4.97 PATH 11 FROM HYDRAULIC REFERENCE S26 TO 62 27.86 1.049 1E 3.54 24.7 24.7 K = 5.60 S26S C =120 2.00 -1.5 0.0 27.86 0.240 5.54 1.3 24.7 Vel = 10.44 1.049 2E 26.04 24.5 24.5 EqK = 5.62 S26 C =120 4.00 0.2 0.0 27.86 0.240 30.04 7.3 24.5 Vel = 10.44 28.23 1.380 11.46 32.0 32.0 63 C =120 0.00 0.0 0.0 See PATH 12 56.09 0.231 11.46 2.6 32.0 Vel = 12.15 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Macy's Drawing Date:May 14, 2008 6/10/08 15:40 Tyco Fire Products Page 12 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn 62 56.09 34.7 K = 9.53 PATH 12 FROM HYDRAULIC REFERENCE S27 TO 63 28.23 1.049 1E 2.33 25.4 25.4 K = 5.60 S27S C =120 2.00 -1.0 0.0 28.23 0.246 4.33 1.1 25.4 Vel = 10.58 1.049 1E 18.09 25.5 25.5 EqK = 5.59 S27 C =120 2.00 0.0 0.0 28.23 0.246 20.09 5.0 25.5 Vel = 10.58 1.049 1E 0.71 30.4 30.4 29 0=120 1T 7.00 -0.3 0.0 28.23 0.246 7.71 1.9 30.4 Vel = 10.58 63 28.23 32.0 K = 4.99 PATH 13 FROM HYDRAULIC REFERENCE S25 TO 65 30.74 1.049 1E 2.33 30.1 30.1 K = 5.60 S25S C =120 2.00 -1.0 0.0 30.74 0.288 4.33 1.2 30.1 Vel = 11.52 1.049 1E 18.08 30.4 30.4 EqK = 5.58 S25 C =120 2.00 0.0 0.0 30.74 0.288 20.08 5.8 30.4 Vel = 11.52 1.049 1E 0.71 36.2 36.2 39 0=120 1T 7.00 -0.3 0.0 30.74 0.288 7.71 2.2 36.2 Vel = 11.52 65 30.74 38.1 K = 4.98 JNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Job Water Required Hose Allowance Macy's Static Pressure: 69.0 psi Pressure: 67.5 K. Inside: 100 gpm 9009 SW Hall Blvd Residual Pressure: 60.0 psi System Flow: 344 gpm Outside: 150 gpm Tigard, OR 97223 Flow: 1872 gpm System +Hose: 594 gpm Remote Area: 2 Date: 10/06 Safety Pres: 0.4 psi Loc: @ connection to 12" city Head Elev Pres: 11.2 psi 70 • Supply 250 gpm hose or 60 50 40 30 20 ' 1 11.2 psi 10 150 225 300 375 450 525 600 675 750 Flow (gpm) Nacy's Drawing Date:Nay 14, 2008 6/10/08 15:45 HYDRAULIC DESIGN INFORMATION SHEET Job Name: Macy's Location: 9009 SW Hall Blvd Tigard, OR 97223 Drawing Date: May 14, 2008 Contractor: SimPlexGrinnell L.P. Remote Area Number: 3 Telephone :972- 587 -5233 1125 E. Collins Blvd. Richardson, TX 75081 Designer: R. Timmons Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Non - Combustible Reviewing Authorities:Owner /Fire Marshall Occupancy:Retail Dept Store SYSTEM DESIGN Code: Hazard: System Type:WET Area of Sprinkler Oper. 975 sq ft1 Sprinkler or Nozzle Density (gpm /sq ft) 0.200 I Make: TYCO Area per Sprinkler 120.0 sq ft1 Model: TY -FRB Hose Allowance Inside 0 gpm I K Factor: 5.60 Hose Allowance Outside 0 gpm I Temperature Rating: 155 O LCULATION SUMMARY 11 Flowing Outlets m Required: 579.6 psi Required: 63.8 @ Source WATER SUPPLY Water Flow Test Pump Data Date of Test 10/06 Rated Capacity 0 gpm Static Pressure 69.0 psi Rated Pressure 0.0 psi Residual Pres 60.0 psi Elevation 0 At a Flow of 1872 gpm Make: Elevation 0" Model: Location: @ connection to 12" city main Source of Information: TV Water Co. SYSTEM VOLUME 485 Gallons Notes: AREA 3: CALCULATION: DEMONSTRATES SYSTEM ADEQUACY FOR THE MOST HYDRAULICALLY DEMANDING AREA Macy's Drawing Date:hay 14, 2008 6/10/08 15:45 HYDRAULIC CALCULATION DETAILS QTY DESCRIPTION HYDRAULIC FLOW LOSS LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 3 330 48.5 psi 5 4" Grvd 90 Ell 50' 4" Flngd Gate Valve "721U" PIV 2 ' 1 20 4.026 330 1.7 1 Pipe 4" 10x25 2' 120 4.026 330 0.1 20' 120 4.260 330 0.5 Fixed Flow Flow Loss 100 gpm 1 8" MJ 90 Ell 18' 120 8.071 430 0.0 1 Pipe 8" DIx18 Cl 350 300' 140 8.488 430 0.3 1 8" MJ Tee 35' 120 8.071 430 0.1 1 8" Flngd Gate Valve "721U" PIV 4' 120 8.071 430 0.0 Fixed Flow Flow Loss 150 gpm Elevation Change 29'0" 12.6 Hydr Ref R1 Required at Source 580 Water Source 69.0 psi static, 60.0 psi residual @ 1872 gpm 580 gpm 68.0 psi psi SAFETY PRESSURE 4.2 psi Available Pressure of 68.0 psi Exceeds Required Pressure of 63.8 psi This is a safety margin of 4.2 psi or 6 % of Supply Maximum Water Velocity is 22.1 fps Macy's Drawing Date:May 14, 2008 6/10/08 15:45 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee V Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. K FACTOR Flow factor for open head or path where Flow (gpm) = K x - \/p Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf /ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q /C) ^1.85 / ID ^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Nacy's Drawing Date :Nay 14, 2008 6/10/08 15:45 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K- FACTOR FLOW FLOW (FT) (GPM /(PSI ^)) (PSI) DENSITY (GPM) (GPM) (GPM /SQ.FT) 21 12.54 43.9 22 12.54 34.3 23 11.83 26.8 24 12.04 23.0 25 12.04 18.2 31 11.67 43.9 32 13.15 44.4 36 11.83 44.7 37 11.83 39.7 54 12.54 45.5 55 12.54 45.4 56 12.54 41.8 57 12.54 28.1 58 12.54 24.2 59 12.54 19.2 A4 12.54 46.8 A5 12.54 46.9 A6 12.54 47.5 A7 12.54 48.4 B1 12.54 46.1 B2 12.54 46.1 B3 12.54 46.1 B4 12.54 46.2 = 12.54 46.1 S51 13.42 5.60 16.9 23.0 S52 12.04 23.0 0.20 19.0 S52S 9.50 5.60 19.2 24.5 14.8 0.49 S53 12.04 15.5 S53S 11.00 5.60 15.5 22.1 14.8 S54 11.83 0.44 22.2 S54S 11.00 5.60 22.0 26.3 22.6 0.23 S55 13.15 40.9 S55S 11.00 5.60 40.3 35.5 22.6 0.31 S56 13.06 27.6 S56S 11.00 5.60 27.4 29.3 S57 13.42 5.60 24.0 0.24 S58 11.83 36.5 33.8 24.0 0.28 33.2 S58S 11.00 5.60 32.7 32.0 18.0 0.36 S59 11.83 42.9 S59S 11.00 5.60 42.2 36.4 22.6 S60 13.20 0.32 37.3 S60S 11.00 5.60 36.8 34.0 22.6 0.30 S61 11.17 34.7 S61S 11.00 5.60 34.1 32.7 W 12.54 48.5 22.6 0.29 Max velocity of 22.14 occurs in the pipe from Cl TO 55 Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an "S" is on the branch. Nacy's Drawing Date:May 14, 2008 6/10/08 15:45 Tyco Fire Products Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe P * * * * * ** * * * * * ** POINT Qt Pf /ft TOTAL Pf NOTES Pn PATH 1 FROM HYDRAULIC REFERENCE S53 TO W (PRIMARY PATH) 22.06 1.049 1E 1.04 15.5 15.5 K = S53S 0=120 2.00 -0.5 0.0 5.60 22.06 0.156 3.04 0.5 15.5 Vel = 8.27 1.049 17.00 15.5 15.5 EqK = 5.60 S53 C =120 0.00 0.0 0.0 22.06 0.156 17.00 2.7 15.5 Vel = 8.27 1.049 1E 0.50 18.2 18.2 25 0=120 1T 7.00 -0.2 0.0 22.06 0.156 7.50 1.2 18.2 Vel = 8.27 23.00 1.049 8.54 19.2 19.2 59 C =120 45.06 0.585 0.00 0.0 0.0 See PATH 2 8.54 5.0 19.2 Vel = 16.89 24.54 1.380 11.46 24.2 24.2 58 C =120 69.60 0.344 10 0.00 0.0 0.0 See PATH 3 11.46 3.9 24.2 Vel = 15.08 t 26.25 1.380 10.00 28.1 28.1 57 C =120 0.00 0.0 0.0 See PATH 4 95.85 0.621 10.00 6.2 28.1 Vel = 20.76 29.32 1.610 20.00 34.3 34.3 22 C =120 0.00 0.0 0.0 See PATH 5 125.17 0.481 20.00 9.6 34.3 Vel = 19.92 2.067 1T 11.00 43.9 43.9 21 0=120 10.00 0.0 0.0 125.17 0.142 21.00 3.0 43.9 Vel = 12.08 204.40 4.260 24.00 46.9 46.9 A5 C =120 329.57 0.120 0.00 0.0 0.0 See PATH 6 24.00 0.6 46.9 Vel = 7.49 4.260 1T 8.31 47.5 47.5 A6 C =120 26.33 0.0 0.0 329.57 0.025 34.64 0.9 47.5 Vel = 7.49 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Macy's Drawing Date:May 14, 2008 6/10/08 15:45 Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe P * * * * * ** * * * * * ** POINT Qt Pf /ft TOTAL Pf NOTES Pn PATH 1 FROM HYDRAULIC REFERENCE S53 TO W (PRIMARY PATH) 4.260 3.45 48.4 48.4 A7 0 =120 0.00 0.0 0.0 329.57 0.025 3.45 0.1 48.4 Vel = 7.49 W 329.57 48.5 K = 47.33 PATH 2 FROM HYDRAULIC REFERENCE S51 TO 59 23.00 1.049 2E 2.46 16.9 16.9 K = 5.60 S51 0 =120 1T 9.00 0.4 0.0 23.00 0.169 11.46 1.9 16.9 Vel = 8.62 59 23.00 19.2 K = 5.25 t .TH 3 FROM HYDRAULIC REFERENCE S52 TO 58 24.54 1.049 1E 2.54 19.2 19.2 K = 5.60 S52S 0=120 2.00 -1.1 0.0 24.54 0.190 4.54 0.9 19.2 Vel = 9.20 1.049 1E 19.00 19.0 19.0 EqK = 5.64 S52 0 =120 2.00 0.0 0.0 24.54 0.190 21.00 4.0 19.0 Vel = 9.20 1.049 1E 0.50 23.0 23.0 24 0=120 1T 7.00 -0.2 0.0 24.54 0.190 7.50 1.4 23.0 Vel = 9.20 58 24.54 24.2 K = 4.99 PATH 4 FROM HYDRAULIC REFERENCE S54 TO 57 26.25 1.049 lE 0.83 22.0 22.0 K = 5.60 S54S 0 =120 2.00 -0.4 0.0 26.25 0.215 2.83 0.6 22.0 Vel = 9.84 P "TTS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Macy's Drawing Date:hay 14, 2008 6/10/08 15:45 Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** POINT Qt Pf /ft Pf NOTES * * * * * ** TOTAL p PATH 4 FROM HYDRAULIC REFERENCE S54 TO 57 CONTINUED 1.049 1E 19.00 22.2 22.2 EqK = 5.57 S54 C =120 2.00 0.0 0.0 26.25 0.215 21.00 4.5 22.2 Vel = 9.84 1.049 1E 0.71 26.8 26.8 23 C =120 1T 7.00 -0.3 0.0 26.25 0.215 7.71 1.7 26.8 Vel = 9.84 57 26.25 28.1 K = 4.95 PATH 5 FROM HYDRAULIC REFERENCE S56 TO 22 29.32 1.049 1E 2.06 27.4 27.4 K = 5.60 S56S C =120 2.00 -0.9 0.0 29.32 0.264 4.06 1.1 27.4 Vel = 10.99 1.049 1E 17.52 27.6 27.6 EqK = 5.58 S56 0=120 1T 7.00 0.2 0.0 29.32 0.264 24.52 6.5 27.6 Vel = 10.99 22 29.32 34.3 K = 5.00 PATH 6 FROM HYDRAULIC REFERENCE S58 TO A5 32.01 1.049 1E 0.83 32.7 32.7 K = 5.60 S58S C =120 2.00 -0.4 0.0 32.01 0.311 2.83 0.9 32.7 Vel = 12.00 1.049 1E 19.00 33.2 33.2 EqK = 5.56 S58 C =120 2.00 0.0 0.0 32.01 0.311 21.00 6.6 33.2 Vel = 12.00 1.049 1E 0.71 39.7 39.7 37 0=120 1T 7.00 -0.3 0.0 32.01 0.311 7.71 2.4 39.7 Vel = 12.00 PNITS - DIAMETER (INCH) LENGTH FOOT ( ) FLOW (GPM) PRESSURE (PSI) Macy's Drawing Date:May 14, 2008 6/10/08 15:45 Tyco Fire Products Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 6 FROM HYDRAULIC REFERENCE S58 TO A5 CONTINUED 33.83 1.380 11.46 41.8 41.8 56 C =120 0.00 0.0 0.0 See PATH 8 65.84 0.310 11.46 3.6 41.8 Vel = 14.26 36.36 1.380 1.08 45.4 45.4 55 C =120 0.00 0.0 0.0 See PATH 11 102.20 0.700 1.08 0.8 45.4 Vel = 22.14 4.260 0.42 46.1 46.1 C1 C =120 0.00 0.0 0.0 102.20 0.003 0.42 0.0 46.1 Vel = 2.32 68.23 4.260 8.50 46.1 46.1 B3 C =120 0.00 0.0 0.0 See PATH 7 170.43 0.007 8.50 0.1 46.1 Vel = 3.87 33.97 4.260 1T 31.00 46.2 46.2 B4 C =120 26.33 0.0 0.0 See PATH 9 204.40 0.010 57.33 0.6 46.2 Vel = 4.65 4.260 12.00 46.8 46.8 A4 C =120 0.00 0.0 0.0 204.40 0.010 12.00 0.1 46.8 Vel = 4.65 A5 204.40 46.9 K = 29.84 PATH 7 FROM HYDRAULIC REFERENCE S61 TO B3 32.69 1.049 1E 0.17 34.1 34.1 K = 5.60 S61S C =120 2.00 -0.1 0.0 32.69 0.323 2.17 0.7 34.1 Vel = 12.25 1.049 2E 20.17 34.7 34.7 EqK = 5.55 S61 0=120 1T 9.00 -0.2 0.0 32.69 0.323 29.17 9.5 34.7 Vel = 12.25 1.049 iT 0.88 43.9 43.9 31 C =120 5.00 -0.4 0.0 32.69 0.323 5.88 1.9 43.9 Vel = 12.25 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Macy's Drawing Date:Nay 14, 2008 6/10/08 15:45 Tyco Fire Products Page 9 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 7 FROM HYDRAULIC REFERENCE S61 TO B3 CONTINUED 1.380 1T 1.50 45.5 45.5 54 C =120 6.00 0.0 0.0 32.69 0.085 7.50 0.6 45.5 Vel = 7.08 4.260 10.00 46.1 46.1 B1 C =120 0.00 0.0 0.0 32.69 0.000 10.00 0.0 46.1 Vel = 0.74 35.54 4.260 1T 2.00 46.1 46.1 B2 C =120 26.33 0.0 0.0 See PATH 10 68.23 0.001 28.33 0.0 46.1 Vel = 1.55 B3 68.23 46.1 K = 10.04 PATH 8 FROM HYDRAULIC REFERENCE S57 TO 56 ( 33.83 1.049 2E 10.42 36.5 36.5 K = 5.60 S57 C =120 4.00 0.4 0.0 33.83 0.344 14.42 5.0 36.5 Vel = 12.68 56 33.83 41.8 K = 5.23 PATH 9 FROM HYDRAULIC REFERENCE S60 TO B4 33.97 1.049 1E 2.20 36.8 36.8 K = 5.60 S6OS C =120 2.00 -1.0 0.0 33.97 0.347 4.20 1.5 36.8 Vel = 12.74 1.049 1E 17.66 37.3 37.3 EqK = 5.56 S60 0=120 1T 7.00 0.3 0.0 33.97 0.347 24.66 8.6 37.3 Vel = 12.74 B4 33.97 46.2 K = 5.00 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Nacy's Drawing Date:hay 14, 2008 6/10/08 15:45 Tyco Fire Products Page 10 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 10 FROM HYDRAULIC REFERENCE S55 TO B2 35.54 1.049 1E 2.15 40.3 40.3 K = 5.60 S55S C =120 2.00 -0.9 0.0 35.54 0.377 4.15 1.6 40.3 Vel = 13.32 1.049 1E 2.31 40.9 40.9 EqK = 5.56 S55 C =120 iT 7.00 0.0 0.0 35.54 0.377 9.31 3.5 40.9 Vel = 13.32 1.610 2E 14.23 44.4 44.4 32 0=120 1T 16.00 0.3 0.0 35.54 0.047 30.23 1.4 44.4 Vel = 5.66 B2 35.54 46.1 K = 5.23 PATH 11 FROM HYDRAULIC REFERENCE S59 TO 55 36.36 1.049 lE 0.83 42.2 42.2 K = 5.60 S59S C =120 2.00 -0.4 0.0 36.36 0.393 2.83 1.1 42.2 Vel = 13.63 1.380 17.00 42.9 42.9 EqK = 5.55 S59 C =120 0.00 0.0 0.0 36.36 0.103 17.00 1.8 42.9 Vel = 7.88 1.380 1E 0.71 44.7 44.7 36 C =120 iT 9.00 -0.3 0.0 36.36 0.103 9.71 1.0 44.7 Vel = 7.88 55 36.36 45.4 K = 5.40 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Job Water Required Hose Allowance Macy's Static Pressure: 69.0 psi Pressure: 63.8 1. Inside: 0 gpm 9009 SW Hall Blvd Residual Pressure: 60.0 psi System Flow: 580 gpm Outside: 0 gpm Tigard, OR 97223 Flow: 1872 gpm System +Hose: 580 gpm Remote Area: 3 Date: 10/06 Safety Pres: 4.2 psi Loc: @ connection to 12" city Head Elev Pres: 11.9 psi 70 0 - _ Supply • • 60 50 40 - - i 30 - • 20 0 psi 10 150 225 300 375 450 525 600 675 750 Flow (gpm) °. r 'tom ? cl 'lir al led ,,, ,, TUBE & CONDUIT a . • ` '� � �». �` � ��n� �h � � �. R � .aa g - 3 A 5' F � ' ' [ 44M if t � ) Y £ s' t .... ,, ......,, , BID,T;;;;;F...... ,,,,- ...-- . -'-'. . Vi. #. -ir tf„.#11:0, 44 t...,,,0:67 ,„-.:Avisofottegi&gia me .1 ''.. pti.,,,:ii!,. '4‘33010.):::',5.34mMj!&itivitit,443meiViiiil :,::„ iiia .,,,,.„. ,,,,,:41,,TI--.,,,12-i-lt;'..'-cTi.''';',4..-,',-..'''.,-ii-ile''..':IT:i.i.-'7='!''',-,,,,-'7,!i.,.40'?Eir'"'.:.' E ' IR • xi fu ixRAirrif ., OFFICE COPY ,,,/,,tig&r,r- C/Z '7 . ■ q��� s r� N eL li eiV (CC.) • E 1 0/ 4 0 . . . _I . . Schedule-1O®/Schedule-40® Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule -10 /Schedule -40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule -10 /Schedule -40 gives you the extra quality assurance you demand. Our Sch -10 (1' / "- 8 ") pipe and Sch -40 (1"- 2V pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Sch-40 Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') Wt/Lift (24') Wt/Lift (25') Schedule-10/Schedule-40 product can be In; mm In, mm Lbs /Ft; Kg /m Lbs /Ft; Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg "hot -dip" galvanized to meet FM requirements for dry systems in 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 accordance with the zinc coating 25 26.6 2.5 3.05 70 1,120 1,280 1,334 specifications of ASTM A -123. 11/4" 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 Superior Coating 1W 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 Our advanced formula mill coating of- 2" 2.067 3.650 5.13 30 2,300 2,628 2,738 fors a clean, durable surface. It is also 50 52.5 5.4 7.63 30 1,043 1,192 1,242 paint -ready for custom color applications 2W 2.469 5.790 7.86 19 2,310 2,640 2,750 without special preparation. 65 62.7 8.6 11.73 19 1,048 1,197 1,247 The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe Sch•10 Specifications products up to 4.5000" in diameter is coated with our new Antibacterial For- NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') Wt/Lift (24') Wt/Lift (25') mula, "ABF'. In scientific laboratory In; mm In; mm Lbs/Ft; Kg /m Lbs/Ft; Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg test, ABS proved to have superior resis- 1" 1.097 1.400 1.81 91 2,675 3,053 3,185 tance to microbial colonization of pipe 25 27.9 2.1 2.70 91 1,213 1,385 1,445 walls, thereby delaying or possibly pre- 11/4' 1.442 1.810 2.52 61 2,319 2,664 2,760 venting the onset of Microbiologically 32 36.6 2.7 3.75 61 1,052 1,208 1,252 Influenced corrosion (MIC) when the 11/2" 1.682 2.080 3.04 61 2,664 3,045 3,172 First Sprinkler System is first installed. 40 42.7 3.1 4.52 61 1,208 1,381 1,439 American Made 2" 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 Meets "Buy American" requirement 21/2" 2.635 3.530 5.89 30 2,224 2,542 2,648 and is available through distributors in 65 66.9 5.3 8.77 30 1,009 1,153 1,201 the USA, Canada and Mexico. 3" 3.260 4.330 7.94 19 1,728 1,975 2,057 Specifications & Approvals 80 82.8 6.4 11.82 19 784 896 933 4" 4.260 5.610 11.78 19 2,238 2,558 2,665 Schedule -10 /Schedule -40 pipe are in 90 108.2 8.3 17.53 19 1,015 1,160 1,209 compliance with the following: 5" 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 ASTM A -135, and NFPA 13. Both pipe 6" 6.357 9.290 23.03 10 1,951 2,230 2,322 products have a working pressure rating 150 161.5 13.8 34.27 10 885 1,012 1,053 of 300 psi maximum and also meet the 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 stringent requirement for the following 200 209.5 24.5 59.75 7 1,100 1,256 1,309 tests: • Welded Outlets 431 41/:. OTh • Hydrostatic Pressure • Side Wall Rupture Listed Approved Listed • Vibration Test is �e� l�1111 � . _! 16100 S. Lathrop • Harvey, IL 60426 Customer Service: iir�rr allied 11350 Norcom Rd. • Philadelphia, hia, PA 19154 (800) 882 -5543 a vital part of your world TUBE & CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708 - 339 -1806 S5 - 3 z ,a FlexHead Commercial Ceiling Sprinkler System F Loss Data and y Speci y � gd " k% d f ? , ' _ FlexHead Outlet Hose Assembly Equivalent Length of 1" Maximum Rated Model # Size Length ft(m) schedule 40 pipe ft(m) Pressure psi (kPa) 2024 1 /2in. 2ft (0.6m) 17ft (5.1m) 175 (1205) '�" 2036 1 /2in. 3ft (0.9m) 22ft (6.6m) 175 (1205) 2048 1 /2in. 4ft (1.2m) 24ft (7.3m) 175 (1205) { 2060 1 /2in 5ft (1.5m) 25ft (7.5m) 175 (1205) A' <r- 2072 1 /2in. 6ft (1.8m) 28ft (8.4m) 175 (1205) 2024 3 /4in. 2ft (0.6m) 9ft (2.7m) 175 (1205) 4rn 2036 3 /4in. 3ft (0.9m) 16ft (4.8m) 175 (1205) 2048 3 /4in. 4ft (1.2m) 21ft (6.4m) 175 (1205) 2060 3 /4in. 5ft (1.5m) 22ft (6.6m) 175 (1205) , 2072 3 /4in. 6ft (1.8m) 25ft (7.5m) 175 (1205) C, Flexhead products are intended for use in hydraulically designed wet, pre - action, deluge or dry pipe sprinkler systems per NFPA 13, 13R, .)X' and 13D guidelines. The hydraulic loss of the FlexHead needs to be included in the hydraulic design calculations the same as a valve or fitting. Each FlexHead Sprinkler Drop has a 3" minimum bend radius per UL guidelines, and a 7" minimum bend radius per FM guidelines. ` System Specifications Usage of Flexible Piping Systems Sprinkler system final connections in commercial Contractor shall provide flexible piping connections ' i „ ( ceilings shall be FlexHead model # as manufactured to sprinkler heads for both suspended and sheet - 4 by FlexHead Industries Inc. Holliston, MA USA (800) rock ceilings. All flexible piping systems shall be UL 829 6975 or (508) 893 9596, Fax (508) 893 6020 as Listed and FM Approved and suitable for their approved by Factory Mutual Research Corporation intended use. ' ; and Underwriters Laboratories. All flexible piping connections to include a fully ��. Each FlexHead System includes multi port ceiling welded (non - mechanical fittings), braided, leak- mounting bracket with hardware and welded, leak tested sprinkler drop with a minimum internal cor- 'e tested 1" braided FlexHead Flexible Sprinkler Drop'. rugated hose diameter of 1 inch; and a one -piece The Fire Protection Contractor shall be responsible for multi -port ceiling bracket with removable attach- `'. the installation of sprinkler head and the final connec- menit hub and self - securing integrated snap -on don, fill and test of the FlexHead Ceiling System to clip -ends, for attachment to ceiling grid without sprinkler sub -main in accordance to NFPA guidelines. the need for a screw fastener. FlexHead Ceiling Sprinkler System Model Numbers Acceptable Manufacturer(s): Model # 2024 2 ft. FlexHead Sprinkler Drop 1. FlexHead series 2000 as manufactured by Model # 2036 3 ft. FlexHead Sprinkler Drop Flexhead Industries of Holliston, MA USA Model # 2048 4 ft. FlexHead Sprinkler Drop (800) 829 -6975 or (508) 893 -9596, Fax (508) Model # 2060 5 ft. FlexHead Sprinkler Drop 893 -6020 in lengths of 2ft to 6ft. . , . 4 Model # 2072 6 ft. FlexHead Sprinkler Drop r - _ Note: FlexHead products are compatible with FM /UL y listed sprinkler heads. s DIVISION 13 13910 BASIC FIRE SUPPRESSION MATERIALS & METHODS FlexHead Industries, Inc. Holliston. MA FlexHead. Sprinkler Connections Founded in 1992, FlexHead Industries is dedi- cated to providing safe, leading edge technol- og ies that promote increased installation and C ommercial maintenance of automatic sprinkler systems. Sprinkler It Product Description, Applications FlexHead manufactures flexible stainless steel Connection hose assemblies that connect sprinkler heads to Y� •, the branch lines. These systems install in a quarter of the time of hard pipe armovers and o sprinkler heads can be easily relocated, in spected and maintained. With no rigid jo B > b the branch line and the head, the , t ; ,t flexible connection is impervious to building , . , z , s . , motion, even in seismically active areas. It remains completely watertight under the most rigorous conditions. With any contractor installed sprinkler head of choice, this pressure /leak tested system is available in 2 - 6' (0b - 1.8 m) hose lengths, making it ideal for any commercial, institutional duct or cleanroom application. In addition, RexHeade both minimizes the cost and simplifies the labor required to bring unsprinklered build ,. ings up to code. It installs in minutes, even in the : i ` ` ` , `" most restrictive of spaces. #, . j ` Features, Advantages ; + 2 FlexHead sprinkler connections provide engi - J neers, architects, contractors and building .. owners with a level of flexibility previously .z unavailable, including: • Reduced labor costs and callbacks !Exhaust Duct aj' • Expedites retrofitting of buildings with con fined spaces sprinkler li • Predictable installation - Eliminates bidding problems and scheduling delays Connection 41 • Fast -track construction for rapid building oc- cupancy „ .. 4 • • Compatible with any FM /UL approved ) sprinkler head • 100% leak tested system ,-, • Industrial grade, all welded, no 0-ring corn i c i ) struction �gi+h • Adjustable height and sprinkler alignment/ center -of -tile uniformity � • No additional hangers required � ' • • Compatible with Blazemaster Fire Sprinkler C: w,, -$ . � „< Systems j Properties, Performance W • All products meet NFPA 13 guidelines • Commercial products are approved for use 1 with light, medium and heavy load grids ? :0,;:!.1,,,,,,i, t "i . a €�rl (ASTM C635, C636) «i • All products are rated up to 175 or 300 psi (1205 - ®. r �� 4*-,-,--,- or 2067 kPa) • All products are International Building Code <� `• C ,, _ 44 g (IBC) compliant for sprinklers installed in seis- `. r , mic design classes C, D, E and F . fi • Commercial product is FM approved and UL r4 . r z t listed for suspended ceiling and gypsum , - f # � ; ° board ceiling installations s �T J Construction, Materials, Finishes e . � - ,^ "I 6. Every FlexHead sprinkler connection co f, /a complete with the flexible hose and attachment ,., ,+ bracket. Each connection is 100% factory tested, z s,,' :; .• all stainless steel construction and is ready to k I , ` t Install right out of the box. so- rg Contact SP E6 o wrap F112 . CATAL (800) 829-6975: (508) 893 -9596 Qh Er CA 0 Fax: (508) 893-6020 E -mail: info@FlexHead.com www.ReedFir www.flexhead.com c 2006 Deed CannuGbn Darn. AS Rphts Reserved FlexH Suspende Ce iling Deta mo � w �+ Each FM -a roved unit is rea ,, N' 1'1'1' 1'11V '1'IV'$$$$1'1 � pressure- and leak- tested, and comes , rl'►' 111 1 ► 1 ► I j 1 ► 1 ►► 1 ►[' 1�1�1 1 1�1�1 1 1 1 s1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1II 1107 , r lYllllll,llb11 _ complete with a fl e xi ble stainless -steel hose ff1111 n'N %11,1 and mounting bracket with adjustable hub. �11111 Sp rinkler r1r�llllllllll!Ib branchline r% o I%1 % ad ill VIII 11 lll,� sprinkler drop ►1111% % %111 11%11 1111111 111 1111 Multi - c eil i n g grid mounting bracket Adjustable hub ' tr y l I II Suspended /, ` I�� t -bar grid C Ceiling Sprinkler head FlexHead Meta Stud Deta 41 ". HN % %� '1i111Hn,, 1111; 1 I 1 I I � � 1� I� 1� f� 1 � 1� 1' 1' 1 n, Sprinkler 111, 1 � ►1111111 � 1 � 1 ���1�� 1 ��� 1 1 1 1 1 1'1t branchline 1 1 1 I 1 I 1 I 1 1 1 1 1 1�1� 0 ',I 1%11% FlexHead 1,�11I111I111I�1 sprinkler drop 1 1111111 ► mounting bracket x� ice - Metal stud �,� ��'�- ' Sheetrock ceiling Sprinkler head ti 1l FlexHead Commercial Ceiling Sprinkler System T esting and Approvals FM Global Testing - FlexHead series 2000 stainless steel sprinkler connections _ Hydrostatic Strength Test Pressure Cycling Test A sample FlexHead was subjected to a hydrostatic A sample FlexHead was filled with water and bent 5 pressure of four (4) times the rated working pres- at a 90° angle and subjected to 20,000 cycles of sure of 175 psi (1205 kpa) to 700 psi (4825 kpa) for pressure varying from 0 psi (0 kpa) to 175 psi a period of five minutes. The assembly shall show (1205 kpa) at a rate of approximately 6 cycles per no signs of rupture, cracking, permanent distortion, minute. After the successful completion of the pres- 1 or deterioration of performance characteristics. The sure cycling tests the sample was subjected to the FlexHead successfully passed this test. hydrostatic pressure test at 700 psi and showed no signs of deterioration. The FlexHead successfully Vibration Test passed this test. A sample FlexHead was secured to a vibration table. The FlexHead hose was bent in a 90° angle and Fatigue Test pressurized to 90 psi (620 kpa) and the mounting A sample FlexHead was subjected to 50,000 cycles bracket and hose where then subjected to a total of of repeated flexing at a rate of 5 to 30 cycles per 25 hours of severe vibration conditions. After the minute per section 8.3 of ISO standard 10380. After successful completion of the vibration tests the the successful completion of the fatigue test the . sample was subjected to the hydrostatic pressure sample was subjected to the hydrostatic pressure test at 700 psi and showed no signs of deteriora- test at 700 psi and showed no signs of deteriora- - • , tion. The FlexHead successfully passed this test. tion. The FlexHead successfully passed this test. Friction Loss (Equivalent length of pipe.) Head Deployment °, To determine the effect of the FlexHead to the A sample FlexHead installed in a suspended ceiling ' ' discharge coefficient of the sprinkler, the average was fitted with a sprinkler head and pressurized to „ friction loss through the FlexHead shall be equated 26 -175 psi. The sprinkler head was then activated to the theoretical length of nominal 1" diameter by a heat source at various pressures, and the sprin- "' schedule 40 sprinkler pipe which would produce kler head deployed. The assembly shall show no the same amount of friction loss. Please see friction signs of distortion or deterioration of performance loss table. on the assembly or sprinkler head. The FlexHead successfully passed this test. • .` Vacuum Test A sample FlexHead was subjected to a vacuum of 25 inHG for a period of five minutes. After the success- ful completion of the Vacuum Test the sample was subjected to the hydrostatic pressure test at 700 psi and showed no signs of deterioration. The FlexHead successfully passed this test. I i .% Underwriters Laboratory Testing - FlexHead' series 2000 stainless steel sprinkler connections ,,, „, Hydrostatic Pressure Test High Temperature Exposure Test ., , "EpEV A sample FlexHead was subjected to a hydrostatic A sample FlexHead was subjected to hydrostatic ; "� �: i- pressure of five (5) times the rated working pres- pressure of 500 psi (3.45 MPa) and then subjected 5 sure of 175 psi (1205 kpa) to 875 psi (6030 kpa) to a temperature of 375° F (191° C) for a period of _ ,� , . r ” for a period of one minute. The assembly shall show 90 days. After the successful completion of the no signs of rupture, cracking, permanent distortion, high temperature test the FlexHead Sprinkler -Drop 0 � "' or deterioration of performance characteristics. The was subjected to the hydrostatic test of 500 psi FlexHead successfully passed this test. (3.45 MPa) for a period of one minute and showed no signs of deterioration or leakage. The FlexHead Vibration Test successfully passed this test. A sample FlexHead was subjected to hydrostatic pressure of 500 psi (3.45 MPa). The FlexHead hose Salt Spray Corrosion Test was bent in a 90° angle and pressurized to 175 psi A sample FlexHead was subjected to salt spray (fog) :;:,;^.4. (1.21 MPa) and the mounting bracket and hose test, per ASTM B117 -94, for a period of 10 days and . � where then subjected to a total of 60 hours of verti- showed no signs of deterioration or incipient corro :' cal vibration and 60 hours of horizontal vibration sion. The FlexHead successfully passed this test. ' with the amplitude of 0.04 inch (1.02 mm) at a continuously varying frequency between 18 and 37 Water Hammer Test hertz. After the successful completion of the vibra- A sample FlexHead was subjected to 3,000 applica tion tests the sample was subjected to the hydrosta- tions of pressure pressure surges from 50 -500 psig tic pressure test at 500 psi and showed no signs of at a rate of 60 cycles per minute and showed no deterioration or leakage. The FlexHead successfully signs of deterioration or leakage. After the sur- passed this test. cessful completion of the Water Hammer test the FlexHead was subjected to the hydrostatic test of . ,° Friction Loss (Equivalent length of pipe.) 500 psi (3.45 MPa) for a period of one minute and .-' T IVit o determine the effect of the FlexHead to the dis- showed no signs of deterioration or leakage. The charge coefficient of the sprinkler, the average fric- FlexHead successfully passed this test. tion loss through the FlexHead shall be equated to the theoretical length of nominal 1 inch diameter Freezing Test schedule 40 sprinkler pipe which would produce A sample FlexHead was filled with water and the same amount of friction loss. Please see friction exposed to an atmosphere of 10 °F ( -29 °C) for a loss table. period of 24 hours and showed no signs of deterio- ration or leakage. After the successful completion Mechanical Strength Test of the Freezing Test the FlexHead was subjected A sample FlexHead was secured and subjected to a to the hydrostatic test of 500 psi (3.45 MPa) for torsion force with a torque of 60 pound -feet (81 N a period of one minute and showed no signs of m) applied to the outlet. After the successful corn deterioration or leakage. The FlexHead successfully pletion of the mechanical Strength Test the sample passed this test. was subjected to the hydrostatic pressure test at 175 psi (1205 kpa) and showed no signs of deterio- ration or leakage. The FlexHead successfully passed this test. c Ous Underwriters Laboratories Inc.® LISTED VENF March 16, 2000 Flexible Sprinkler Hose Fittings FLEXHEAD INDUSTRIES EX5269 20 MAIN STREET, ACTON, MA 01720 Models 2024, 2036, 2048, 2060, 2072 flexible sprinkler hose fittings having a 300 psi rated pressure. For use with ordinary, intermediate and high temperature rated automatic sprinklers. Maximum number of bends, maximum bend angles and associated pressure losses are shown in the manufacturer's installation instructions. LOOK FOR LISTING MARK ON PRODUCT 4/5/2000 Underwriters Laboratories Inc. Card 1 of 1 VENF July 9, 2002 Flexible Sprinkler Hose Fittings FLEXHEAD INDUSTRIES EX5269 LOWLAND IND PARK, 56 LOWLAND ST, HOLLISTON MA 01746 Models 2024H, 2036H, 2048H, 2060H, 2072H, flexible sprinkler hose fittings having a 300 psi rated pressure. For use with ordinary, intermediate and high temperature rated automatic sprinklers. Models 2024S, 20365, 2048S, 2060S, 2072S , flexible sprinkler hose fittings having a 175 psi rated pressure. For use with ordinary, intermediate and high temperature rated automatic sprinklers. Maximum number of bends, maximum bend angles and associated pressure loses are shown in the manufacturer's installation instructions. LOOK FOR LISTING MARK ON PRODUCT 7/22/2002 Underwriters Laboratories Inc. Card 1 of 1 -ftrklm#11 Mao rdnrii r sriez faA:�.'r fit. trial Stitt Lottrir catk 11 c us Underwriters Laboratories Inc.® FAX N. tip , `'` littp 4WAtit it MTh L LISTED June 21, 2001 ltegtill1 tot WM public FlexHead Industries Mr. Norm MacDonald 56 Lowland St. Holliston, MA 01746 Our Reference: File EX5269 Subject: FlexHead Flexible Sprinkler Hose Fittings Installed Onto Dry Wall Ceiling Grid Dear Mr. MacDonald: This letter is in regard to the subject. Base upon review of the FlexHead UL Listed flexible sprinkler hose fitting system, installation onto a dry wall ceiling grid is acceptable when the ceiling - mounted bracket is screwed to a rigid surface. Self - tapping screws are used to affix the FlexHead mounting bracket to the surface, using the four ports provided which are pre - drilled onto the mount- ing bracket. Very truly yours, EMIL W. MISICHKO (Ext. 42036) Engineering Group Leader Conformity Assessment Services Department 3011 CNBK Emil W. Misichko @us.ul.com A not - for - profit organization dedicated to public safety and committed to quality service APPROVAL REPORT FLEXHEAD CEILING SPRINKLER SYSTEM FOR COMMERCIAL SUSPENDED CEILINGS Prepared For: FlexHead Industries, Inc. 56 Lowland Street Holliston, MA 01746 J.I. 3003667 Class 1637 March 26, 1999 4 1> APPROVED Factory Mutual Research FDLCJ ,nnnnnaolco.com a b of H1BiCD. Revision 3/1/2007 Fig. 200 - "Trimline" Adjustable Band Hanger C OUS LISTED Size Range — 1/2" thru 8" pipe 4> Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping - > purposes. Knurled swivel nut design permits hanger ,-%' - -- adjustment after installation. -`' (, / , k, r'''' i''/^i� Feat — r .. ''7 " 1ij ----- '� • (1/2" thru 2 ") Flared edges ease installation for "' ' ' `' ' " 1 ' � , ` ' \ \ f II . 1 all pipe types and protect C PVC plastic pipe from I (j , 4 `li 1 +l ~.. abrasion. Captured design keeps adjusting nut ■ + - 1 from se B , 9 Han er 9 is easil I � � l aratin P 9 with han er. Y installed around pipe. /I /` A • � " thr u8 tension on nut holds it A / ' V (2 /2 )Sp rin g securely in hanger before installation. Adjusting ;^`�,/ I nut is easily removed. � Approvals — Underwriters' Laboratories listed (1/2" .- � r thru 8 ") in the USA (UL) and Canada (cUL) for steel > and CPVC plastic pipe and Factory Mutual Engineering ,-�'- Approved (3/4" thru 8 "). Conforms to Federal , �- 1/2 THRU 2 INCH PIPE 2 1/2 THRU 8 INCH PIPE Specifications WW -H -171 E, Type 10 and Manufacturers Standardization Society SP -69, Type 10. Maximum Temperature — 650 °F,b* Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCOTM Fig. 200WON.' — t ; • ;` Order By — Figure number and pipe size / f : k r \ f 1( e; `; j /)/ . /I iiiid \ J // :f� Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt. /100 1/2 3/8 8mm or 10mm 31/2 2 /s 400 11 3/4 3/8 8mm or 10mm 31 2 400 11 1 3/8 8mm or 10mm 3% 2% 400 12 11/4 3/8 8mm or 10mm 3 2 400 13 1 3/8 8mm or 10mm 3 2 400 14 2 3/8 8mm or 10mm 4 3 400 15 2 3/8 10mm 5% 4 600 27 3 3/8 10mm 5 4 600 29 3 3/8 10mm 7% 5 600 34 4 3/8 10mm 7% 5 1000 35 5 1/2 12mm 91 6 1250 66 6 1/2 12mm 10 6 1250 73 8 1/2 12mm 13 8 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 90 CUSTOMER SERVICE • 800.786.5266 www.tolco.com tqCD Fire & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series TY -FRB — 2.8, 4.2, 5.6, and 8.0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the Description standard corrosion tests of the appli -.." cable approval agencies, the testing is <„ The Tyco® Series TY -FRB, 2.8, 4.2, not representative of all possible cor- 5.6, and 8.0 K- factor, Upright and Pen- rosive atmospheres. Consequently, it dent Sprinklers described in this data is recommended that the end user be sheet are quick response - standard consulted with respect to the suitability coverage, decorative 3 mm glass bulb of these coatings for any given corro- type spray sprinklers designed for use sive environment. The effects of ambi- , ?` in light or ordinary hazard, commercial ent temperature, concentration of — occupancies such as banks, hotels, chemicals, and gas /chemical velocity, `` Y° shopping malls, etc. should be considered, as a minimum, The recessed version of the Series along with the corrosive nature of the TY -FRB Pendent Sprinkler, where ap- chemical to which the sprinklers will be plicable, is intended for use in areas exposed. with a finished ceiling. It uses either a An intermediate level versions of the two -piece Style 10 (1/2 inch NPT) or Series TY -FRB Pendent Sprinklers Style 40 (3/4 inch NPT) Recessed Es- are detailed in Technical Data Sheet # cutcheon with 1/2 inch 12,7 mm) of ( ) TFP356, and Sprinkler Guards are de- recessed adjustment or up to 3/4 inch tailed in Technical Data Sheet TFP780 (19,1 mm) of total adjustment from the flush pendent position, or a two -piece WARNINGS r . Style 20 (1/2 inch NPT) or Style 30 (3/4 The Series TY - FRB Sprinklers de '° fr- inch NPT) Recessed Escutcheon with scribed herein must be installed and 1/4 inch (6,4 mm) of recessed adjust maintained in compliance with this ment or up to 1/2 inch (12,7 mm) of document, as well as with the applica- total adjustment from the flush pen ble standards of the National Fire Pro - dent position. The adjustment pro tection Association, in addition to the vided by the Recessed Escutcheon re- standards of any other authorities hay- All od el/Sprinkl er duces the accuracy to which the fixed ing jurisdiction. Failure to do so may pipe drops to the sprinklers must be impair the performance of these de- Identification cut. vices. /� Corrosion resistant coatings, where The owner is responsible for maintain- Numbers applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. TY1131 - Upright 2.8K, 1/2 "NPT that which would otherwise be ob - The installing contractor or sprinkler TY1231 - Pendent 2.8K, 1/2 "NPT manufacturer should be contacted TY2131 - Upright 4.2K, 1/2 "NPT with any questions. TY2231 - Pendent 4.2K, 1/2"NPT IMPORTANT TY3131 - Upright 5.6K, 1/2 "NPT Always refer to Technical Data TY3231 - Pendent 5.6K, 1/2 "NPT Sheet TFP700 for the "INSTALLER TY4131 - Upright 8.0K, 3/4 "NPT WARNING" that provides cautions TY4231 - Pendent 8.0K, 3/4 "NPT with respect to handling and instal- TY4831- Upright 8.0K, 1/2"NPT lation of sprinkler systems and com- TY4931- Pendent 8.0K, 1/2 "NPT ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 AUGUST, 2007 TFP171 Page 2 of 10 TFP171 ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SURFACE NPT MAKE -IN ESCUTCHEON DEFECTOR i■r = M 7/, i�� 5 2-1/4" } ( mm) 4 (57,2 mm) ��I . �/� - 1I NOMINAL L 1I 1i MAKE - IN r 2 1- 9/16" I WRENCH `�� i 2- 3/16" 3 (39,7 mm) (55,6 mm) F Pie 1 LATS SSP DEFLECTOR - 2 -7/8" (73,0 mm) DIA. 1 1/2" NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SURFACE NP MAKE -IN ESCUTCHEON DEFLECTOR 6 �_ 7/16" •.,, 5 ! ! rr - -; 2- 3/16" (11,1 mm) (55,6 mm) �- NOMINAL 4 1� 1 i I iI MAKE -IN 1,1/1 m m) I 2-316" � (556 mm) 2 1111r -2" (38 , WRENCH f# 1 . - -- .. .--- . -- FLAT S _ I i i 3 SSP DEFLECTOR 2-7/8" (73,0 mm) DIA. 1 1/2" NPT f + 1 PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K- FACTOR, 1/2 INCH NPT TFP171 Page 3 of 10 ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING NOMINAL RECESSED SURFACE NPT MAKE -IN ESCUTCHEON DEFLECTOR i / ter ? rl1r �[t�, i;;i4IT1g*SITr� 6* 1 MEW_ 5 2-3/16" .� — — '•', - ( 11,1 mm) I 4 (55,6 mm) r�� .� � NOMINAL I ' 1 L "7 MAKE -IN 1 1-1/2" r� r 2 3/16" '4 2 (38,1 mm) I 1 I Ii, WRENCH (55,6 mm) 1 „ - � - c � _ FLATS 1 ,' 3 SSP DEFLECTOR * 2-7/8” (73,0 mm) DIA. 1/2" NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) STYLE 30 or 40 PLATE SEATING NOMINAL RECESSED SU * SURFACE N T MAKE-IN ESCUTCHEON DEFLECTOR 6 1 /2" `' 5 2- 5/16" Ilk � (12,7 mm) (58,7 mm) �� � - I NOMINAL 4 L���, I MAKE -IN /irk 2 r__ 2 -1/4" iii 1 9/16" I I0 i (39,7 mm) WRENCH (5 -1 mm) Y ■ . FLATS I 0� 3 4 "` 1 SSP DEFLECTOR — 2 -7/8" (73,0 mm) DIA. --"– 3/4" NPT I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K- FACTOR, 3/4 INCH NPT Page 4 of 10 TFP171 7/16" (11,1 mm) 1/2" NOMINAL SSU NPT MAKE -IN DEFLECTOR f __--- is • 5 2 -1/4" 2- 3/16" (57,2 mm) f .4m P (55,6 mm) I i 4 I _ � A 1- 9/16" WRENCH r __ Ii 'y 2 (39,7 mm) FLATS y 3 - - 1 SSP * DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K- FACTOR, 1/2 INCH NPT Technical Operation Data The glass Bulb contains a fluid which expands when exposed to heat. When Approvals the rated temperature is reached, the UL and C -UL Listed. fluid expands sufficiently to shatter the FM, LPCB, and NYC Approved. glass Bulb, allowing the sprinkler to (Refer to Table A and B for complete activate and water to flow. approval information including corro- sion resistant status.) Design Maximum Working Pressure Refer to Table C. Criteria Discharge Coefficient K = 2.8 GPM /psi / (40,3 LPM /bar1 /2) The Series TY -FRB Pendent and Up- K = 4.2 GPM /psi (60,5 LPM /bar1 /2) right Sprinklers are intended for fire K = 5.6 GPM /psi (80,6 LPM /bar1/2) protection systems designed in ac- K = 8.0 GPM /psi (115,2 LPM /bar1/2) cordance with the standard installation rules recognized by the applicable Temperature Ratings Listing or Approval agency (e.g., UL Refer to Table A and B Listing is based on the requirements of Finishes NFPA 13, and FM Approval is based Sprinkler: Refer to Table A and B. on the requirements of FM's Loss Pre - Recessed Escutcheon: White Coated, vention Data Sheets ). Only the Style Chrome Plated, or Brass Plated. 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Y Physical Characteristics E Frame Bronze a) Button Brass /Copper o Sealing Assembly E Beryllium Nickel w /Teflont 0 Bulb Glass a Compression Screw Bronze rn Deflector Copper /Bronze a' Bushing (K =2.8) Bronze 5 0 a E TFP171 Page 5 of 10 SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB NATURAL CHROME WHITE*'' LIQUID BRASS PLATED POLYESTER 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY1231) 1, 2, 3, 5 and 175F/79°C Yellow UPRIGHT 200 °F /93 °C Green 2.8 (TY1131) 286 °F /141 °C Blue 1/2° NPT 135 °F /57 °C Orange RECESSED 155F/68°C Red PENDENT (TY1231)* 175F/79°C Yellow Figure 6 200 °F /93 °C Green 1, 2, 5 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT (TY1231) ** 175 °F /79 °C Yellow Figure 7 200 °F /93 °C Green 135F/57°C Orange PENDENT 155FI68°C Red (TY2231) and 175 °F /79 °C Yellow UPRIGHT 200 °F /93 °C Green 4.2 (TY2131) 286 °F /141 °C Blue 1 2 1/2" NPT 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT (TY2231)* 175 °F /79 °C Yellow Figure 6 200 °F /93 °C Green 135F/57°C Orange RECESSED 155 °F /68 °C Red PENDENT (TY2231) ** 175 °F /79 °C Yellow Figure 9 200 °F /93 °C Green NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Re- sponse Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354 -01 -E. 7. Where Polyester Coated Sprinklers are noted to be UL and C -UL Listed, the sprin- klers are UL and C -UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. * ** Frame and Deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K- FACTOR SPRINKLERS Page 6 of 10 TFP171 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE *** LEAD LIQUID BRASS PLATED POLYESTER COATED 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY3231) 1, 2, 3, 4, 5, 6, 7 1,2,3,5 and 175 °F /79 °C Yellow UPRIGHT 200 °F /93 °C Green 5.6 (TY3131) 286 °F /141 °C Blue 1/2" NPT 135 °F /57 °C Orange RECESSED 155F/68°C Red PENDENT 1, 2, 4, 5 N/A (TY3231)* 175 °F /79 °C Yellow Figure 10 200F/93°C Green 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 N/A (TY3231)** 175FI79°C Yellow Figure 11 200F/93°C Green 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY4231) 1, 2, 5 and 175 °F /79 °C Yellow 1, 2, 3, 4, 5, 6, 7 UPRIGHT 200 °F /93 °C Green 8.0 (TY4131) 286 °F /141 °C Blue 3/4" NPT 135FI57°C Green RECESSED 155 °F /68 °C Orange PENDENT 1, 2, 4, 5 N/A (TY4231)* 175 °F /79 °C Red Figure 12 200F193°C Yellow 135 °F /57 °C Orange RECESSED 155 °F /66 °C Red PENDENT 1, 2, 3, 4, 5 N/A (TY4231) ** 175F/79°C Yellow Figure 13 200 °F /93 °C Green 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red 8.0 (TY4931) 1, 2, 5 1/2" and 175 °F /79 °C Yellow 1, 2, 4, 5, 6 NPT UPRIGHT 200 °F /93 °C Green (TY4831) 286F/141°C Blue NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31 -53- 428- 4444/Fax 31 -53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. * ** Frame and Deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K- FACTOR SPRINKLERS TFP171 Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2" RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A 3/4" RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (TY3131) OR 1/2" RECESSED PENDENT 175 PSI (12,1 BAR) NPT (TY3231) N/A (SEE NOTE 1) PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) 3/4" RECESSED PENDENT NPT (TY4231) N/A 8.0 PENDENT (TY4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C -UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE tained with a torque of 10 to 20 ft.lbs. the sprinkler into the sprinkler fitting. Installation (13,4 to 26,8 Nm). A maximum of 30 ft.lbs, (40,7 Nm) of torque is to be used Step 3. Tighten the sprinkler into the The Series TY -FRB Sprinklers must to install sprinklers with 3/4 NPT con- sprinkler fitting using only the W -Type be installed in accordance with the fol- nections. Higher levels of torque may 6 Sprinkler Wrench (Ref. Figure 14). lowing instructions: distort the sprinkler inlet and cause W reference to Figures 1, 2, 3, 4, leakage or impairment of the sprinkler. and 5, the W-Type 6 Sprinkler Wrench NOTES is to be applied to the sprinkler wrench Do not install any bulb type sprinkler if Do not attempt to make-up for insuffi- flats. the bulb is cracked or there is a loss of cient adjustment in the escutcheon The Series TY -FRB Recessed Pen - liquid from the bulb. With the sprinkler plate by under- or over - tightening the dent Sprinklers must be installed in held horizontally, a small air bubble sprinkler. Readjust the position of the accordance with the following instruc- should be present. The diameter of the sprinkler fitting to suit. tions. air bubble is approximately 1/16 inch The Series TY -FRB Pendent and Up- Step A. After installing the Style 10. (1,6 mm) for the 135"F/57°C to 3/32 right Sprinklers must be installed in 20, 30, or 40 Mounting Plate, as appli- inch (2,4 mm) for the 286 °F /141 °C accordance with the following instruc- cable, over the sprinkler threads and temperature ratings. tions. with pipe thread sealant applied to the A leak tight 1/2 inch NPT sprinkler joint Step 1. Pendent sprinklers are to be pipe threads, hand tighten the sprin- should be obtained with a torque of 7 installed in the pendent position, and kler into the sprinkler fitting. to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- upright sprinklers are to be installed in Step B. Tighten the sprinkler into the mum of 21 ft. lbs. (28,5 Nm) of torque the upright position. sprinkler fitting using only the W -Type may be used to install sprinklers with Step 2. With pipe thread sealant ap- 7 Recessed Sprinkler Wrench (Ref. 1/2 NPT connections. A leak tight 3/4 plied to the pipe threads, hand tighten Figure 15). With reference to Figure 1, inch NPT sprinkler joint should be ob- 2, 3, and 4, the W -Type 7 Recessed Page 8 of 10 TFP171 2 -7/8" DIA. _ 2 -7/8" DIA. _ 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) 1/211/8" (73,0 mm) 1/2" (12,7 mm) (15,9±6,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,7±3,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1 /8" - •�' (3,2 mm) __ ,� (3,2 mm) Jr. � loll � , r �:� re„ el. ITr Ii - __� 111 t ' MOUNTING MOUNTING SURFACE SURFACE �r a,, 1 .. - w-1 , .., ' SERIES 1- 5/16" (33,3 mm) SERIES 1- 5/16" (33,3 mm) CLOSURE TY -FRB 13/16" (20,6 mm) CLOSURE TY -FRB 1- 1/16" (27,0 mm) FIGURE 6 FIGURE 7 SERIES TY -FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K- FACTOR, 1/2 INCH NPT 2.8 K- FACTOR, 1/2 INCH NPT 2 -7/8" DIA. 2 -7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) _ 1/2 ±1/8" (73,0 mm) 1/2" (12,7 mm) (15,9 ±6,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,7±3,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8 cor .151 ji ilff __I i (3,2 mm) I l \ ;AWN 111 W (3 2 mm) I' , W MOUNTING IN MOUNTING , SURFACE ■ SURFACE - - CLOSURE SERIES 1 - 1/4" (31,8 mm) CLOSURE SERIES 1 -1/4" (31,8 mm) TY -FRB 3/4" (19,1 mm) TY - FRB 1" (25,4 mm) FIGURE 8 FIGURE 9 SERIES TY -FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K- FACTOR, 1/2 INCH NPT 4.2 K- FACTOR, 1/2 INCH NPT Sprinkler Wrench is to be applied to work on the fire protection system that altered after leaving the factory. Modi- the sprinkler wrench flats. it controls, permission to shut down the fied sprinklers must be replaced. Step C. Athe ceiling has been affected fire protection system must be Sprinklers that have been exposed to S in- S talled After t a finish coat has been n- obtained from the proper authorities corrosive products of combustion, but plied, slide on the Style 10, 20, 30, or and all personnel who may be affected have not operated, should be replaced 40 Closure over the Series TY FRB by th act must be not if they cannot be completely cleaned Sprinkler and push the Closure over The owner must assure that the sprin by wi the sprinkler with a cloth or the Mounting Plate until its flange klers are not used for hanging of any by brush i t with a soft bristle brush. comes in contact with the ceiling. objects; otherwise, non - operation in Care must be exercised to avoid dam - the event of a fire or inadvertent opera age to the sprinklers - before, during, are and tion may result. and after installation. Sprinklers dam - Absence of an escutcheon, which is aged by dropping, striking, wrench u sed to cover a clearance hole, may twist/slippage, or the like, must be re- Maintenance placed. Also, replace any sprinkler delay the time to sprinkler operation in that has a cracked bulb or that has lost The Series TY -FRB Sprinklers must a fire situation. liquid from its bulb. (Ref. Installation be maintained and serviced in accord- Sprinklers that are found to be leaking Section). ance with the following instructions: or exhibiting visible signs of corrosion must be replaced. Frequent visual inspections are rec- NOTES ommended to be initially performed for Before closing a fire protection system Automatic sprinklers must never be corrosion resistant coated sprinklers, main control valve for maintenance painted, plated, coated or otherwise after the installation has been com- TFP171 Page 9 of 10 2 -7/8" DIA. 2 -7/8" DIA. _ 5/8 ±1/4" (73,0 mm) 3/4" (19,1 mm) 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (15,916,4 mm) 1/4" (6,4 mm) (12,713,2 mm) 2 -1/4" DIA. 2 -1/4" DIA. y 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" Il u �' (3,2 mm) (3,2 mm) G I / WilliT � ��� r ArA le . 1 MOUNTING 11011 MOUNTING SURFAC Nil SURFACE == � = CLOSURE SERIES 1 -1/4" (31,8 mm) CLOSURE SERIES 1 -1/4" (31,8 mm) TY -FRB 3/4" (19,1 mm) TY -FRB 1" (25,4 mm) FIGURE 10 FIGURE 11 SERIES TY -FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K- FACTOR, 1/2 INCH NPT 5.6 K- FACTOR, 1/2 INCH NPT 2 -7/8" DIA. - 2 -7/8" DIA. - 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (15,9±6,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,7±3,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" — 7 II (3,2 mm) / rII (3,2 mm) No ' � . \ ..••■■" f .11 ad 1 MOUNTING I ` MOUNTING SURFACE I'� SURFACE • I • CLOSURE SERIES 1- 5/16" (33,3 mm) CLOSURE SERIES 1 -5/16" (33,3 mm) TY -FRB 13/16" (20,6 mm) TY -FRB 1 -1/16" (27,0 mm) FIGURE 12 FIGURE 13 SERIES TY -FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K- FACTOR, 3/4 INCH NPT 8.0 K- FACTOR, 3/4 INCH NPT pleted, to verify the integrity of the cor- L� WRENCH rosion resistant coating. Thereafter, RECESS annual inspections per NFPA 25 should suffice; however, instead of in- WRENCH RECESS 10-T1 specting from the floor level, a random (END "A" USED FOR final n sampling of close -up visual inspec- 1/2" NPT MODELS) / , tions should be made, so as to better �.� `l determine the exact sprinkler condi- `" tion and the long term integrity of the ... corrosion resistant coating, may as it ma WRENCH RECESS (END "B" USED FOR PUSH WRENCH be affected by the corrosive conditions ( 3/4" NPT MODELS) IN TO ENSURE present. ENGAGEMENT The owner is responsible for the in- FIGURE 14 WITH SPRINKLER WRENCHING AREA spection, testing, and maintenance of W - TYPE 6 SPRINKLER FIGURE 15 their fire protection system and de- WRENCH vices in compliance with this docu- W - TYPE 7 RECESSED ment, as well as with the applicable SPRINKLER WRENCH standards of the National Fire Protec- facturer should be contacted relative tion Association (e.g., NFPA 25), in to any questions. addition to the standards of any other It is recommended that automatic Inspection Service in accordance with authorities having jurisdiction. The in- sprinkler systems be inspected, local requirements and /or national stalling contractor or sprinkler menu- tested, and maintained by a qualified codes. Page 10 of 10 TFP171 P/N 57 - XXX - X - XXX I I TEMPERATURE MODEL /SIN RATING SPRINKLER 330 2.8K UPRIGHT (1/2 "NPT) TY1131 135 135 °F /57 °C 331 2.8K PENDENT (1/2 "NPT) TY1231 1 NATURAL BRASS 155 155 °F /68 °C 340 4.2K UPRIGHT (1/2 "NPT) TY2131 4 WHITE POLYESTER 175 175 °F /79 °C 341 4.2K PENDENT (1/2 "NPT) TY2231 3 WHITE (RAL9010)* 200 200 °F /93 °C 370 5.6K UPRIGHT (1/2 "NPT) TY3131 9 CHROME PLATED 286 286 °F /141 °C 371 5.6K PENDENT (1/2 "NPT) TY3231 7 LEAD COATED 390 8.0K UPRIGHT (3/4 "NPT) TY4131 391 8.0K PENDENT (3/4 "NPT) TY4231 * Eastern Hemisphere sales only. 360 8.0K UPRIGHT (1/2 "NPT) TY4831* 361 8.0K PENDENT (112 "NPT) TY4931* TABLE D PART NUMBER SELECTION SERIES TY -FRB PENDENT AND UPRIGHT SPRINKLERS In no event shall TFBP be liable, in Limited contract, tort, strict liability or under Ordering any other legal theory, for incidental, ldam- procedure Warranty indirect, special or consequential dam- ages, including but not limited to labor Products manufactured by Tyco Fire & charges, regardless of whether TFBP When placing an order, indicate the Building Products (TFBP) are war- was informed about the possibility of full product name. Refer to the Price ranted solely to the original Buyer for such damages, and in no event shall List for complete listing of Part Num- ten (10) years against defects in mate- TFBP's liability exceed an amount bers. rial and workmanship when paid for equal to the sales price. Contact your local distributor for avail - and properly installed and maintained under normal use and service. This The foregoing warranty is made in lieu ability. warranty will expire ten (10) years of any and all other warranties. ex from date of shipment by TFBP. No press or implied. including warranties Sprinkler Assemblies with NPT warranty is given for products or corn - of merchantability and fitness for apar Thread Connections: ponents manufactured by companies ticular purpose. Specify: (Specify Model /SIN), Quick ownership with TFBP Response, (specify K- factor), (specify not affiliated b y P This limited warranty sets forth the ex- temperature rating), Series TY -FRB or for products and components which clusive remedy for claims based on (specify Pendent or Upright) Sprinkler have been subject to misuse, improper failure of or defect in products, materi- with (specify type of finish or coating), installation, corrosion, or which have als or components, whether the claim P/N (specify from Table D). not been installed, maintained, modi- is made in contract, tort, strict liability fled or repaired in accordance with ap- or any other legal theory. Recessed Escutcheon: plicable Standards of the National Fire Specify: Style (10, 20, 30, or 40) Re Protection Association, and /or the This warranty will apply to the full ex P fY Y ( ) standards of any other Authorities tent permitted by law. The invalidity, in cessed Escutcheon with (specify*) fin - Having Jurisdiction. Materials found whole or part, of any portion of this ish, P/N (specify *). by TFBP to be defective shall be either warranty will not affect the remainder. * Refer to Technical Data Sheet TFP770. repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor Sprinkler Wrench: authorizes any person to assume for it, Specify: W -Type 6 Sprinkler Wrench, any other obligation in connection with P/N 56- 000 -6 -387. the sale of products or parts of prod- ucts. TFBP shall not be responsible for Specify: W -Type 7 Sprinkler Wrench, sprinkler system design errors or inac- P/N 56- 850 -4 -001. curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tLIcD Fire & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series RFII — 5.6 K- factor "Royal Flush II" Pendent Concealed Sprinklers Quick & Standard Response, Standard Coverage General Cap. The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect the iiilik Description sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- The Series RFII Quick Response tective Cap can also be used to mark (3 mm bulb) & Standard Response (5 the center of the ceiling hole into plas- mm bulb), 5.6 K- Factor, "Royal Flush ter board, ceiling tiles, etc. by gently II" Concealed Pendent Sprinklers are pushing the ceiling product against the decorative sprinklers featuring a flat Protective Cap. When the ceiling in- cover plate designed to conceal the stallation is complete the Protective sprinkler. It is the best choice for archi- Cap is removed and the Cover Plate tecturally sensitive areas such as hotel Assembly installed. lobbies, office buildings, churches, As an option, the Series RFII Standard and restaurants. Response (5 mm bulb) "Royal Flush II" Each unit includes a Cover Plate As- Concealed Pendent Sprinklers may be sembly that conceals the sprinkler op- fitted with a silicone Air and Dust Seal erating components above the ceiling. (Ref. Fig. 5). The Air and Dust Seal is The separable two -piece design of the intended for sensitive areas where it is Technical Cover Plate and Support Cup Assem- desirable to stop air and dust travel blies allows installation of the sprin- through the cover plate from the area Data klers and pressure testing of the fire above the ceiling. protection system prior to installation WARNINGS Approvals for Series RFII of a suspended ceiling or application The Series RFII Concealed Pendent pp of the finish coating to a fixed ceiling. UL and C -UL Listed. FM Approved. They also permit removal of sus- Sprinklers described herein must be NYC under MEA 353 -01 -E. LPCB pended ceiling panels for access to installed and maintained in compli- (Ref. No. 094a/09 for TY3551 & building service equipment without ance with this document, as well as 094a/10 for TY3531) Approved. with the applicable standards of the having to first shut down the fire pro- The approvals apply only to the serv- tection system and remove sprinklers. National Fire Protection Association ice conditions indicated in the Design in addition to the standards of any Criteria section. Also, the separable two -piece design other authorities having jurisdiction. of the the Sprinkler provides for 1/2 Failure to do so may impair the per- Approvals for Air & Dust Seal inch (12,7 mm) of vertical adjustment, formance of these devices. (Part #10908100) to reduce the accuracy to which the UL and C -UL Listed for use with the length of fixed pipe drops to the sprin- The owner is res for maintain RFII (TY3551) Standard Response klers must be cut. ing their fire protection s and de- Concealed Sprinkler. vices in proper operating condition. The Series RFII Sprinklers are The installing contractor or sprinkler Maximum Working Pressure: shipped with a Disposable Protective manufacturer should be contacted Maximum 250 psi (17,3 bar) by UL, with any questions. C -UL, and NYC. Maximum 175 psi (12,1 bar) by FM and LPCB. IMPORTANT Temperature Ratings Always refer to Technical Data Model /Sprinkler 155F/68C Sprinkler - 135F/57C Plate Sheet TFP700 for the "INSTALLER 200F/93C Sprinkler - 165F/74C Plate WARNING" that provides cautions Identification Discharge Coefficient with respect to handling and K = 5.6 GPM /psi / (80,6 LPM /bar lation of sprinkler systems and corn- umbers ponents. Improper handling and in- Adjustment stallation can permanently damage TY3551 (5 mm bulb) 1/2 inch (12,7 mm) a sprinkler system or its compo- TY3531 (3 mm bulb) Finishes nents and cause the sprinkler to fail Cover Plate: Chrome Plated, Brass to operate in a fire situation or cause Plated, or White Painted (Custom it to operate prematurely. paint matches and colors other than white are available on request.) Page 1 of 4 JANUARY, 2008 TFP181 Page 2 of 4 TFP181 Physical Characteristics 1/2" NPT ! / SEALING Frame Bronze , ASSEMBLY Support Cup . Chrome Plated Steel Guide Pins Stainless Steel � �' � 1 i�� Deflector Bronze FRAME ' j Compression Screw Brass i� r n Bulb Glass I ' 1 �'� CAP Cap Bronze or Copper SUPPORT Sealing Assembly CUP WITH 1 � BULB Beryllum Nickel w /Teflon* ROLL FORMED iIi Cover Plate Brass THREADS l Retainer Brass COMPRESSION Ejection Spring . . . . Stainless Steel SCREW GUIDE m .� Patents PINS (2) "' U.S.A. 4,014,388 I ,_ _______, DEFLECTOR I (DROPPED i i Operation DEFLECTOR �=r � POSITION) C- z When exposed to heat from a fire, the I SPRINKLER/SUPPORT CUP Cover Plate, which is normally sol- I ASSEMBLY dered to the Retainer at three points, THREAD INTO ' I RETAINER falls away to expose the Sprinkler As- J I WITH THREAD sembly. At this point heDeflectorsu - UNTIL TIN I Y• P P UNTIL MOUNTING 0 O s DIMPLES ported by the Guide Pins drops down SURFACE IS tO its operational position. FLUSH WITH EJECTION The glass Bulb contains a fluid that CEILING SPRING expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the war glass Bulb, activating the sprinkler and allowing water to flow. SOLDER COVER TABS (3) COVER PLATE /RETAINER PLATE ASSEMBLY Design FIGURE 1 Criteria SERIES RFII CONCEALED SPRINKLER ASSEMBLY The RFII (TY3551), 5 mm Bulb Type, Concealed Pendent Sprinklers are UL Step 1. The sprinkler must only be and C -UL Listed as standard response Installation installed in the pendent position and - standard spray sprinklers for use in with the centerline of the sprinkler per - accordance with the current NFPA The Series RFII must be installed in pendicular to the mounting surface. standard. They are FM Approved as accordance with the following instruc- Step 2. Remove the Protective Cap. standard response - standard spray tions: sprinklers for use in accordance with Step 3. With pipe thread sealant ap- the current FM Loss Prevention Data NOTES plied to the pipe threads, hand tighten Sheets. Do not install any bulb type sprinkler if the sprinkler into the sprinkler fitting. TY3531 3 mm Bulb Type, the bulb is cracked or there is a loss of Step 4. Wrench tighten the sprinkler The RFII (TY3531) yp liquid from the bulb. With the sprinkler Concealed Pendent Sprinklers are UL held horizontally, a small air bubble using only the RFII Sprinkler Wrench Sprinkler Wrench C -UL Listed as quick response - should be present. The diameter of the (Ref. Figure re 3). The RFII S p rin standard spray sprinklers for use in air bubble is approximately 1/16 inch Wrench is to be applied to thhe e 5p- accordance with the current NFPA (1,6 mm) for the 155 °F /68 °C and 3/32 kler as shown in Figure 3. standard. They are FM Approved as inch (2,4 mm) for the 200 °F /93 °C tem Step 5. Replace the Protective Cap standard response - standard spray perature ratings. (Ref. Figure 4) by pushing it upwards sprinklers for use in accordance with A 1/2 inch NPT sprinkler joint should until it bottoms out against the Support the current FM Loss Prevention Data be obtained with a minimum to maxi Cup. The Protective Cap helps prevent Sheets. damage to the Deflector and Arms dur- mum torque of 7 to 14 ft.lbs. (9,5 to The Series RFII Concealed Pendent 19,0 Nm). Higher levels of torque may ing ceiling installation coatis during Sprinklers are only listed and ap- distort the sprinkler inlet with conse appl of the finish coating of the proved with the Series RFII Concealed quent leakage or impairment of the ceiling. It may also be used to locate Cover Plates having a metallic or white sprinkler. the center of the clearance hole by painted finish. gently pushing the ceiling material up Do not attempt to compensate for in against the center point of the Protec- The Series RFII must not be used in sufficient adjustment in the Sprinkler tive Cap. applications where the air pressure Assembly by under - or over tightening above the ceiling is greater than that the Sprinkler /Support Cup Assembly. NOTE below. Down drafts through the Sup Readjust the position of the sprinkler As long as the Protective Cap remains port Cup could delay sprinkler opera fitting to suit. in place, the system is considered to tion in a fire situation. be "Out of Service ". * Registered Trademark of DuPont TFP181 Page 3 of 4 FACE OF CLEARANCE HOLE CLEARANCE SPRINKLER L� DIAMETER HOLE FITTING DIMENSION C I ►i c SPRINKLER 1 • 1 SUPPORT CUP i� - -- ASSEMBLY \ ��� �I�1� I 1/2" (12,7 mm) i 41 t , �I THREADED D ADJUSTMENT i FACE OF CEILING, i RETAINING RING I FIGURE 4 MOUNTING DISPOSABLE PROTECTIVE CAP SURFACE — i Step 6. After the ceiling has been com- /. pleted with the 2 -1/2 inch (63,5 mm) I I diameter clearance hole and in prepa- I I i - ration for installing the Cover Plate As- sembly, remove and discard the Pro - ` � tective Cap, and verify that the 3/16" to 11/16" MANUFACTURER DEFLECTOR COVER PLATE Deflector moves up and down freely. If (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER the Sprinkler has been damaged and REFERENCE 3/32" (2,4 mm) POSITION ASSEMBLY the Deflector does not move up and down freely, replace the entire Sprin- COVER PLATE COVER PLATE kler assembly. Do not attempt to mod- - PROFILE DEPTH . DIAMETER ify or repair a damaged sprinkler. DIMENSION B DIMENSION A Step 7. When installing an Air and Dust Seal, refer to Figure 5, otherwise proceed to Step 8. To attach the Air A: 3 -1/4" (82,6 mm) C: 2 -3/8" to 2 -5/8" (60,3 to 66,7 mm) and Dust Seal, verify the angle of the B: 3/16" (4,8 mm) D: 1 -3/4" to 2 -1/4" (44,5 to 57,2 mm) outside edge of the seal is oriented according to Figure 5. Start the edge FIGURE 2 of the Retainer in the grooved slot of around n d and Dust Seal and con SERIES RFII CONCEALED SPRINKLER around the retainer until the entire Air INSTALLATION DIMENSIONS and Dust Seal is engaged. NOTE - The Air and Dust Seal is only to be installed on the periphery of the Re ,'1 =t� FRAME ; =j __ tainer. sm. ARM 7 r1i Step 8. Screw on the Cover Plate /Re- 11 /, tainer Assembly until the Retainer - ' _ � Figure 2 (or Air and Dust Seal - Figure C SUPPORT i /1.' 5) contacts with the ceiling. Do not CUP I- I 1 continue to screw on the Cover l _ i Plate /Retainer Assembly such that it i lifts a ceilin anel out of its normal lit '■" ' • '� position. If the Cover Plate /Retainer Assembly cannot be engaged with the — — — — O Support Cup or the Cover Plate /Re- 7/8" (23 mm) tainer Assembly cannot be engaged SQUARE sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. L. ALIGN J ARROWS WITH \ Care and FRAME ARMS a� Maintenance ACCEPTS �. � r te' The Series RFII must be maintained 0 1/2" SOCKET — and serviced in accordance with the DRIVE following instructions: NOTES FIGURE 3 Absence of the Cover Plate Assembly RFII SPRINKLER WRENCH may delay sprinkler operation in a fire situation. Page 4 of 4 TFP181 When properly installed, there is a SUPPORT SPRINKLER FACE OF ORIENT nominal 3/32 inch (2,4 mm) air gap CUP CEILING SEAL between the lip of the Cover Plate and BEVEL AS the ceiling, as shown in Figure 2. This covER / �, SHOWN air gap is necessary for proper opera- PLA tion of the sprinkler. If the ceiling is to ` + �; RETAINER — be repainted after the installation of ►, ASSEMBLY ��' the Sprinkler, care must be exercised 1 =111M" to ensure that the new paint does NOT ' I seal off any of the air gap. L � a Are: ROOM Factory painted Cover Plates MUST • .1_ .-∎ SEAL NOT be repainted. They should be re- — — — ' LIP OF COVER RETAINER PLATE placed, if necessary, by factory painted units. FIGURE 5 Do not pull the Cover Plate relative to OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) the Enclosure. Separation may result. Before closing a fire protection system ance with local requirements and /or of merchantability and fitness for a main control valve for maintenance national codes. particular purpose. work on the fire protection system that This limited warranty sets forth the ex- it controls, permission to shut down the clusive remedy for claims based on affected fire protection system must be Limited failure of or defect in products, materi- obtained from the proper authorities als or components, whether the claim and all personnel who may be affected W arranty is made in contract, tort, strict liability by this action must be notified. or any other legal theory. Sprinklers that are found to be leaking Products manufactured by Tyco Fire & or exhibiting visible signs of corrosion Building Products (TFBP) are war- This warranty will apply to the full ex- must be replaced. ranted solely to the original Buyer for tent permitted by law. The invalidity, in ten (10) years against defects in mate- whole or part, of any portion of this Automatic sprinklers must never be rial and workmanship when paid for warranty will not affect the remainder painted, plated, coated or otherwise and properly installed and maintained altered after leaving the factory. Modi- under normal use and service. This fied sprinklers must be replaced. Ordering warranty will expire ten (10) years Sprinklers that have been exposed to from date of shipment by TFBP. No corrosive products of combustion, but warranty is given for products or com- Procedure have not operated, should be replaced ponents manufactured by companies if they cannot be completely cleaned When placing an order, indicate the by wiping the sprinkler with a cloth or not affiliated by ownership with TFBP full product name. Contact your local or for products and components which distributor for availability. brushing it with a soft bristle brush. y• have been subject to misuse, improper Care must be exercised to avoid dam- installation, corrosion, or which have Sprinkler Assembly: age to the sprinklers - before, during, not been installed, maintained, modi- Specify: (SIN), (specify temperature and after installation. Sprinklers dam- tied or repaired in accordance with ap- rating) Series RFII Concealed Pen - aged by dropping, striking, wrench plicable Standards of the National Fire dent Sprinkler, P/N (specify). twist/slippage, or the like, must be re- Protection Association, and /or the placed. Also, replace any sprinkler that standards of any other Authorities 155F/68790-1-155 C 200F/93C TY3551 51- has a cracked bulb or that has lost Having Jurisdiction. Materials found TY3531 51- 792 -1 -155 5 792 -1 - liquid from its bulb. (Ref. Installation by TFBP to be defective shall be either Section). repaired or replaced, at TFBP's sole If a sprinkler must be removed, do not option. TFBP neither assumes, nor Separately Ordered Cover Plate: reinstall it or a replacement without authorizes any person to assume for it, Specify: (specify temperature rating) reinstalling the Cover Plate Assembly. any other obligation in connection with it (s ecif Cos P/N s pec s Plate w If a Cover Plate Assembly becomes the sale of products or parts of prod- with (specify finish), P/N (specify). dislodged during service, replace it im- ucts. TFBP shall not be responsible for 135F/57C(a) 165F/74C(b) mediately. sprinkler system design errors or inac- Brass 56- 792 -1 -135 56- 792 -1 -165 curate or incomplete information sup- Bright Brass 56- 792 -2 -135 56- 792 -2 -165 The owner is responsible for the in- plied by Buyer or Buyer's repre- B us d Chrome 56 -792 -8 -135 56- 792 -5 -165 spection, testing, and maintenance of sentatives. White 56- 792 -0 -135 56- 792 -0 -165 their fire protection system and de- In no event shall TFBP be liable, in White (RAL9010)` 56- 792 -3 -135 56- 792 -3 -165 56-792-4-135 56-792-4-165 vices in compliance with this docu- contract, tort, strict liability or under Off White ite 56-792-5-135 56-792-5-165 ment, as well as with the applicable any other legal theory, for incidental, Black 56 -792 -6 -135 56- 792 -6 -165 standards of the National Fire Protec- indirect, special or consequential dam- Custom 56- 792 -X -135 56- 792 -X -165 tion Association (e.g., NFPA 25), in ages, including but not limited to labor (a) For use with 155F/68C sprinklers. addition to the standards of any other charges, regardless of whether TFBP (b) For use with 200F/93C sprinklers. authorities having jurisdiction. The in- was informed about the possibility of ' Eastern Hemisphere sales only. stalling contractor or sprinkler manu- such damages, and in no event shall Sprinkler Wrench: facturer should be contacted relative TFBP's liability exceed an amount Specify: RFII Sprinkler Wrench, to any questions. equal to the sales price. P/N 56- 000 -1 -075. Automatic sprinkler systems should be The foregoing warranty is made in lieu Air and Dust Seal: inspected, tested, and maintained by a of any and all other warranties. Ax- Specify: Air and Dust Seal, qualified Inspection Service in accord- press or implied. including warranties P/N 56- 908 -1 -001. © 2008 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446