Loading...
Plans RECEIVED MAY 0 4 2015 CITY OF TIGAFID �.. • .. BUILDING DIVISION ti 72" Range 48" 14" (� ` 1 : Salamander Broiler Fryer 12.5 '� " 0 Of y i 73 ii 8 Type I Hood ®'a •s's 1 \k0 0 0 0 O 11111111111111 — a � o 0 - OHO 0 0 0 - — CCf Q 3 - L ° Q I �� �z m � Ansul O O O 8.5' > f i '0�' O O O Type I Hood . c Er a . a c ° ¢ -� System Q v u° a u Cylinders o & Controls. 36" 36" Griddle Range C UWE Crw?yy' V A Y 1 �A Fire System Drawing Overhead View Ansul wet chemical fire system Model R- 102. 3— 3 gallon cylinders. Flow point capacity: 33: Flow points used: -27- b BY: Guardian Fire Prot. Inc. FOR: Bajio Notes: System installed in accordance with 1012 SW "A" ST. 9009 SW Hall Ansul Design, Installation, Recharge, Corvallis OR 97333 Tigard OR 97223 and Maintenance Manual. • (541) 752-2258 System tested in accordance with CCB# 100355 exp. 6 -23 -06 Scale: None U.L. Standard # 300. This drawing may not be reproduced without written permission from Date: 4-05 Drawn By: MAF Guardian Fire Protection Inc. City, state, county agencies are excepted during the course of plan review or permit process. Duct: 10" x15" Fusible 2W Links 8 8.5' Type I Hood 460 0 Ansul a- 1N 1F 1F 1F Cheesemelter 40" 40" 40" 2120 48" 48" 48" 10" 20" � 1 17 n 36" Griddle 36" Range Steamer Fire System Drawing Front View Small Hood BY: Guardian Fire Prot. Inc. FOR: Bajio Notes: System installed in accordance with 1012 SW "A" ST. 9009 SW Hall Ansul Design, Installation, Recharge, Corvallis OR 97333 Tigard OR 97223 and Maintenance Manual. (541) 752— 2258 System tested in accordance with CCB# 100355 exp. 6 -23 -06 Scale: None U.L. Standard # 300, This drawing may not be reproduced without written permission from Date: 4-05 Drawn By: MAF Guardian Fire Protection Inc. City, state, county agencies are excepted during the course of plan review or permit process. I Ducts : Automatic tic gas 10" x 18" shut off valve. • ii ____--- 2W Fusible 2W Links 12.5' Type I Hood 8 / 8 Aso ago 450 E 811E _ I II II IIII I I II II IIII I I 1A Q 1A iN� iN L -" JI` L _I 9 iN 1N Salamander Flow pts. used: 230 27" 15" 15" 60" a 15" 9 11 8 47' 40" 40" Pta 9 Back 290 290 290 290 Hood 15" is" 15" 15" O 20" 20" 20" 20" Remote Manual Actuator IIIIIIIIIIIII1 (in egress) nI 4, In ni In 14" 48" 72" Range Fryer Radiant Broiler Fire System Drawing , Front View Large Hood BY: Guardian Fire Prot. Inc. FOR: Bajio Notes: System installed in accordance with 1012 SW "A" ST. 9009 SW Hall Ansul Design, Installation, Recharge, Corvallis OR 97333 Tigard OR 97223 and Maintenance Manual. (541) 752-2258 System tested in accordance with CCB# 100355 exp. 6 -23 -06 Scale: None U.L. Standard # 300. This drawing may not be reproduced without written permission from Date: 4-05 Drawn By: IMF Guardian Fire Protection Inc. City, state, county agencies are excepted during the course of plan review or permit process. so..Liizuuo io:o_t rA.A 002 • • SECTION IV - SYSTEM DESIGN i , ° UL EX. 3470 ULC CEx747 Page 4-49 10 -1 -02 REV.2 DISTRIBUTION PIPING REQUIREMENTS (Continued) Distribution Piping Requirements - 9.0 Gallon System t 17p ► This optional configuration consists only of three 3 -gallon tanks, all • pressurized from a single double -tank nitrogen cartridge with R. • expellant gas hoses connected as shown in Figure 88. Tanks No. 1 and No. 2 must be connected directly to the regulator with sepa- � -} 1 rate expellant gas hoses and Tank No. 3 must be connected to . Tank No. 2 with a third expellant gas hose as shown in Figure 88. Each tank must be connected to an independent distribution pip- f • ing network as shown in Figure 88. Distribution piping require - 1 - ments for each network must be as follows: , 1. The maximum length between the start of the first branch line _ and the start of the last branch line must not exceed 24 ft.� -" ��' (7.3 m . When the supply �.p ( ) pply fine is split, the co mbined total of both legs of the supply line (from the start of the first branch line to the start of the last branch line) must not exceed 24 ft. f I I I • (7.3 m). See Figure 84. u I I 1 2. The total length of all branch lines must not exceed 36 it. 3.0 i 3.0 i 3.0 r • (10.9 m). See Figure 84. GALLON GALLON a GALLON TANK TANK 1 TANK lb • 3. Use a 3/8 in. union to connect the tank adaptor to the 3/8 in. NO.3 NO.2 F. NO.1 supply line. 4. A maximum of two nozzles are allowed per duct branch line_ 1 5. When using this 9.0 gallon system configuration, no mani- folding of distribution piping is allowed. Two TANK ENCLOSURE 3 GALLON REGULATED DOUBLE TANK arsooEN ASSEMBLY ART NO. RE EASE ASSEMBLY, CARTRIDGE OR 6. When an ANSUL AUTOMAN Regulated Release is utilized in 419604 (INCLUDES (2) OR 3 GALLON LTA - 101 -30 CARTRIDGE this configuration, additional regulator actuators cannot be S'1 M Er RE 'c ED ACTUATOR (REGULATED ACTUATOR used. • 7. Only 3 gallon tanks can be utilized in this configuration. FIGURE 88 I 8. The requirements of the following table must not be exceeded aOaa, •�" • for each 3 gallon tank: ReQtNrements Duct Plenum Appliance SuoDly Line Branch Line Branch Line branch Line Pipe Size 3/8 in. 3/8 in. 3/8 in. 3/8 in. Maximum Length 40 ft. 8 ft. 4 ft. 12 ft. (12.2 m) (2.4 m) (1.2 m) (3.7 m) Maximum Rise 6 ft. 4 ft 2 ft. 2 ft. (1.8 m) (1.2 m) (.6 m) (.6 m) Maximum 90° 9 4 4 6 Elbows Maximum Tees 1 2 2 4 Maximum Flow 11• 4 2 4 Numbers 'Exceptions: 1. Twelve (12) lbw numbers are allowed in any lank not containing Iwo -flow appliance nozzles. and/or, a 1N nozzle for wok or griddle protection. and /or. a IF nozzle for range protec- tion, and/or, a 3N nozzle for fryer protection. 2 Twelve (12) flow numbers are allowed with any one lank using only Iwo -flow appliance nozzles r 3. Twelve (12) flow numbers are allowed with any one tank using only three -flow appliance nozzles Special Instructions: r 1. When four (4) Dean Indus:nes GTI Gas Fryers are N protected at {ow proximity as shown in Figure 58 on Page 4-32. the as.. large piping must be as shown n Figure 59 on Page 4 -32. 2. For certain McOonald•s spplicdtions, 11.5 flow numbers are allowed when using a combination of one (1) 2W duct nozzle. ne (1) 1/2N eladrostalic preopnlalor nozzle, one (1) 1N plenum nozzle, and four (4) iwo •flaw appliance noales. Contact Amur Applications Engineering Department Ic additional Information. uoiii /zuuo 1D:Di FAA 16 00 3 . SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4 -40 REV. 2 10 -1-02 TANK AND CARTRIDGE REQUIREMENTS ACTUATION AND EXPELLANT GAS LINE REQUIREMENTS Once the hazard analysis is completed and the total nozzle flow This section contains the guidelines for installing the actuation and numbers are established, the quantity and size of agent tanks and expellant gas lines between the regulated release mechanism reg- cartridges needed to supply the nozzles with the proper volumes ulator, each regulated actuator regulator, and each agent tank. of agent at the proper flow rates can be determined. For cartridges These limitations should be considered when selecting the corn - used in the regulated release mechanism, flow capacities, tank ponent mounting locations. quantities and sizes, and regulated release cartridge options are given in the table below. Actuation Gas Line — 6 to r Tanks Maximum Total Quantity and Regulated Release ' 8 Tank maximum retlecIS the utifimtion or 3 tank regulated actuators. Flow Size of Cartridge Options 1. Use only 1/4 in. Schedule 40 black iron, hot - dipped galva- Numbers* Tank(s) plitrooerl Carbon Dioxide nized, chrome - plated, or stainless steel pipe and fittings. 1 — 5 (1) 1.5 Gallon LT -20 -R 101 -10 2. The actuation gas line piping is installed from the regulated 6 — 11 (1) 3.0 Gallon LT 30 R 101_20 release mechanism to each regulated actuator connected 11 — 16 (1) 1.5 Gallon Double within the system. The total length of the actuation gas line 101 -30 from the r (1) 3.0 Gallon egulated release assembly to the regulated actuator • assembly(ies) must not exceed - 20 ft. (6 m) when using an 16 — 22 (2) 3.0 Gallon Double 101 -30 ** • LT-20-R, an LT 30-R nitrogen cartridge, or a 101 -10 or a 101 - 20 When one or more regulated actuators are used, the following • carbon dioxide cartridge. See Figure 71. tank and cartridge combinations apply for each regulated actuator: Regulated Actuator Regulated Actuator Tank(s) Cartridge (1) 1.5 Gallon LT20 -R or 101 -10 (1) 3.0 Gallon LT -30 -R or 101 -20 (1) 1.5 Gallon and LTA- 101 -30 or 101 -30** or (1) 3.0 Gallon double tank (2) 3.0 Gallon LT-A -101 -30 or 101 -30" or double tank • For a c ons to rrarmum flow numbers, see Distribution Ion Piping Recements for 1.5 gat. Salon systems in this Section. �� • " The 101-30 cartridge can net be used when (21 two 3.0 gallon tanks are manifokied together. ) For higher total flow numbers (23 to 110), multiple cartridges and regulated actuators are required as shown in the System Selection Guide in Section IX — Appendix. REGULATED ACTUATOR ASSEMBLY EXPELLANT GAS LINES NOT INCLUDED IN ACTUATION GAS LINE LENGTH TOTALS REGULATED .. o ll ACTUATOR ACTUATION GAS LINE WITH AN LT -20-R. ASSF LT -30.R, 101.10 OR 101.20 CARTRIDGE MAXIMUM LENGTH OF 20 FT. (6 m), MAXIMUM NO. OF FITTINGS 9 ! REGULATED ASSEMBLY �, 'ANSUL AUTOMAIr REGULATED RELEASE ASSEMBLY IL �:/ i il • FIGURE 71 • ors 05/09/2005 16:01 PAS 410ul Guardian Fire Protection Inc. 1012 SW 'A' Street Corvallis, OR 97333 541.752.2258 Fax: 541.752.4259 Attention: Company Name: Date: — 7_ 6), Time: 3 5e p `� Fax Number. SD •- 6)7 - G , Number of pages: (including cover) v/IC �, c Regarding: From: Notes: -4 PI c4 fa - ice Ci C31 5. (..e4 1-04 05/09/2005 16:01 FAX 4 002 • SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4 -28 REV. 3 10 -1 -02 low.,. Nozzle Application Chart The following chart has been developed to assist in calculating the quantity and type of nozzle required to protect each duct, plenum, or appliance. NOTICE This chart is for general reference only. See complete details for each type of hazard. . Minimum Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping - Hazard Dimensions Quantity Heights Part No._ Flow No. Duct or Transition Length - Unlimited 1 - 430912 1100 (Single Nozzle) Perimeter- 50 in. (127 cm) Diameter - 16 in. (40.6 cm) ■ Duct or Transition Length - Unlimited 1 - 419337 2W (Single Nozzle) Perimeter - 100 in. (254 cm) Diameter - 31 718 in. (81 cm) ■ Duct or Transition Length - Unlimited 2 - 419337 2W (Dual Nozzle) Perimeter - 150 in. (381 cm) Diameter - 48 in. (122 cm) Electrostatic Precipitator Individual Cell 1 - 419334 1/2N (At Base of Duct) ► Plenum Length - 10 ft. (3.1 m) 1 - 419335 1N (Horizontal Protection) . .Plenum Length - 6 ft (1.8 m) 1 - 430192 1100 I (Horizontal Protection) Width -4 ti (1.2 m} 1 419336 1W Plenum Length - 4 ft. (1.2 m) 1 - 419336 1W ► (Vertical Protection) Width -41 (1.2 m) • Fryer /Split Vat Fryer" Maximum Size (without drip board) 15 in. (38 cm) x 14 in. (36 —High Proximity 1 27 - 47 in. 419339 230"'' re f.Z Medium Proximity 1 20 - 27 in. 419340 245 Maximum Size , (without drip board) • 19 1/2 in. (49.5 cm) x 19 in. (48.2 cm) High Proximity 1 21 - 34 in. 419338 3N Low Proximity 1 13 - 16 in. 419342 29 Maximum Size (without drip board) 18 in. (45.7 cm) x 18 in. (45.7 cm) High Proximity 1 25 - 35 in. 419338 3N (64-89 cm) ♦.._ •- For nwniple nozzle proiechon of stngle fryers. see delaitod lnSorrnauon on Pages 4 -12 through 4 -14 • 1/0i ua / GM/3 10:U1 r:>,.. 41 003 SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4 -29 • 10 -1 -02 REV. 3 Nozzle Application Chart (Continued) Minimum Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping - Hazard Dimensions Quantity Heights Part No. flow No. Fryer /Split Vat Fryer" Maximum Size (with drip board) 21 in. (53 cm) x 14 in. (36 cm) (Fry Pot must not exceed 15 in. x 14 in. (38 cm x 36 cm)) High Proximity 1 27 - 47 in. 419339 230 Medium Proximity 1 20 - 27 in. 419340 245 • Maximum Size (with drip board) 25 3/8 in. (64.4 cm) • x 19 1/2 in. (49.5 cm) (Fry pot side must not exceed 19 1/2 in. (49.5 cm) x 19 in. (48.2 cm) High Proximity 1 21 - 34 in. 419338 3N Low Proximity 1 13 - 16 in. 419342 290 Maximum Size (with drip board) 18 in. (45.7 cm) • x 27 5/8 in. (70.2 cm) High Proximity 1 25 - 35 In. 419338 3N (64-89 cm) Range Longest Side 1 30 -50 in. 419333 1F 28 in. (71 cm) (76 - 127 cm) � _4 w/ J Area - 336 sq. in. 40 - 48 in. / ILO/ n (2168 sq. cm) (102 -122 cm) pv 4 it — (With Backshelf) Longest Side (High Proximity) 1 40 - 50 in. 419340 245 28 in. (71 cm) (102 -127 an) Area - 672 sq. in. (4335 sq. cm) Longest Side (Medium Proximity) 1 30 - 40 in. 419341 260 32 in. (81 cm) (76 - 102 cm) Area - 768 sq. in. (4955 sq. cm) Longest Side (Low Proximity) 2 15 - 20 in. 419342 290 -- 36 in. (91 cm) (38 - 51 cm) Area - 1008 sq. in. I, (6503 sq. cm) w . Y */Y 4 • • • For multiple nozzle oraection of single fryers, see detailed information on Pages 4.7 through 4.11. 05/09/2005 16:01 FAX a 004 r . • SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4 -30 . REV. 3 10 -1-02 • • Nozzle Application Chart (Continued) . Minimum Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping - )-lazard Dimensions Quantity Heights Part No. Flow No Griddle Longest Side (High Proximity) 1 30 - 50 in. 419341 260 48 in. (122 cm) (76 - 127 cm) Area - 1440 sq. in. (perimeter (9290 sq. cm) located) Longest Side (High Proximity) 1 30 - 50 in • 19342 290 30 in. (76 c n) (76 - 127 cm) Area - 720 sq. in. (center located) (4645 sq. cm) Longest Side (High Proximity) 1 35 — 40 in. 419335/417332 1 N/1 NSS 36 in. (91 cm) (89 -102 cm) Area - 1080 sq. in. (perimeter located) (6968 sq. cm) Longest Side 1 20 - 30 in. 419342 290 (Medium Proximity) (51 - 76 cm) 48 in. (122 cm) (perimeter Area - 1440 sq. in. located) (9290 sq. cm) Longest Side (Low Proximity) 1 10 - 20 in. 419343 2120 '--- 48 in. (122 cm) (25 - 51 cm) Area - 1440 sq. In. (perimeter ( I c. 4 4.4 G c � j � E e (9290 sq. cm) located) lY Chain Broiler* Longest Side - 34 in. (86 cm) 2 10 - 26 In. 419336/417333 1 W/1 WSS (Overhead Protection) Area - 1088 sq. in. (25 - 66 cm) (7019 sq. cm) " Chain Broiler Length - 43 in. (109 cm) 2 1 - 3 in. 419335/417332 1 N/1 NSS (Horizontal Protection) Width - 31 in. (79 cm) (3 - 8 cm) Gas- Radiant Char - Broiler Longest Side - 36 in. (91 cm) 1 15 - 40 in. 419335/417332 1 WIN S ---- Area - 864 sq. in. (38 - 102 cm) ( ��,�� (5574 sq. cm) 7-.44,4 L Electric Char - Broiler Longest Side - 34 in. (86 cm) 1 20 - 50 in. , 19335/417332 1 N/1 NSS Area - 680 sq. in. (51 -127 cm) . (4388 sq. cm) • Lava -Rock Broiler Longest Side - 24 in. (61 cm) 1 18 - 35 in. 419335/417332 1N /1NSS Area - 312 sq. in. (46 - 89 cm) (2013 sq. cm) Natural Charcoal Broiler Longest Side - 24 in. (61 cm) • 1 18 - 40 in. 419335/417332 1 N/1 NSS Area - 288 sq. in. (46 - 102 cm) (1858 sq. cm) Lava -Rock or Natural Longest Side - 30 in. (76 cm) 1 14 - 40 in. 419338 3N Charcoal Char - Broiler Area - 720 sq. in. (36 - 102 cm) (4645 sq. cm) • Minimum chain broiler exhaust opening - 12 in x 12 in. 131 an x 31 ant, and not less than 60% of internal broiler size. n~ • Ua /U /ZUUD 16:UZ 1 4005 • SECTION IV - SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4 -31 10 -1 -02 REV. 5 Nozzle Application Chart (Continued) Minimum Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping - Hazard Dimensions Quantity Heiohts Part No Flow No. • Wood Fueled Char - Broiler Longest Side - 30 in. (76 cm) 1 14 - 40 in. 419338 3N Area - 720 sq. in. (36 - 102 cm) (4645 sq. cm) Upright Broiler Length - 32.5 in. (82.5 cm) 2 - 419334 1/2N Width - 30 in. (76 cm) Salamander Length - 32.5 in. (82.5 cm) 2 - 419334 1 1/2N Broiler Width - 30 in (76 cm) S'.y f W,,,,n, O6"(-- Wok 14 in.- 30 in. (36 - 76 cm) 1 35 - 45 in. 419341 260 Diameter (89 - 114 cm) 3.75 - 8.0 in. (9.5 - 20 cm) Deep 11 in. - 24 in. (28 - 61 cm) 30 - 40 in. 419335/417332 1 N/1 NSS Diameter (89 - 102 cm) 3.0 -6.0 in. (8 -15.2 cm) • Deep s-�