Loading...
Permit CITY TIGARD MECHANICAL PERMIT 'l;; DEVELOPMENT SERVICES PERMIT #: MEC2000 -00504 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 12/28/00 PARCEL: 1S126C0-00100 SITE ADDRESS: 09225 SW HALL BLVD E SUBDIVISION: ZONING: BLOCK: LOT: JURISDICTION: TIG CLASS OF WORK: ALT FLOOR FURN: EVAP COOLERS: TYPE OF USE: COM UNIT HEATERS: VENT FANS: OCCUPANCY GRP: VENTS WIO APPL: VENT SYSTEMS: STORIES: BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: DOMES. INCIN: 3 - 15 HP: COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: FIRE DAMPERS ?: 30 - 50 HP: REPAIR UNITS: GAS PRESSURE: 50 + HP: WOODSTOVES: FURN < 100K BTU: AIR HANDLING UNITS CLO DRYERS: FURN > =100K BTU: <= 10000 cfm: OTHER UNITS: 1 > 10000 cfm: GAS OUTLETS: Remarks: Medical Gas Piping into One -hour Room. Owner: FEES MENASHE, R BARRY Type By Date Amount Receipt 621 SW ALDER, STE 605 PRMT CTR 12/28/00 $72.50 2720000000 PORTLAND, OR 97205 PLCK CTR 12/28/00 $18.13 2720000000 5PCT CTR 12/28/00 $5.80 2720000000 Phone: Total $96.43 Contractor: ADCOA INC 2142 N KILLINGSWORTH PORTLAND, OR 97217 REQUIRED INSPECTIONS Mechanical lnsp Phone: 503 - 285 -1534 Final Inspection Reg #: LIC 106788 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0080. You may obtain copies of these rules or direct questions to OUNC by calling (503)246 -9189. Issue By: / Permittee Signature: / - Call (5 3) 639 -4175 by 7:00 P.M. for inspections needed the next business day A . Mechanical Permit Application n Date received: P/ /� Permit no.: /fl 9 L ,.I �— City of Tigard Project/appl. no.: Expire date: City of Tigard Address: 13125 SW Hall Blvd, Tigard OR 97223 Date issued: By: Receipt no.: Phone: (503) 639 -4171 Fax: (503) 598 -1960 Case file no.: Payment type: Land use approval: Building permit no.: TYPE OF PERMIT 0 1 & 2 family dwelling or accessory ❑ Commercial/industrial 0 Multi- family )‹fenant improvement ❑ New construction ❑ Addition/alteration/replacement ❑ Other: JOB SITE INFORMATION COMMERCIAL VALUATION SCHEDULE Job address: 25 - SS.LI . u. gz yiD ,___�, (I ndicate equipment quantities in boxes below. Indicate the dollar Bldg. no.: Suite no.: r value of all mecOtical materials, equipment, labor, overhead, Tax map /tax lot/account no.: profit. Value $ rt /S47 4— . Lot: (Block: I Subdivision: *See checklist for important application information and Project name: i/ , le,Q ,..5- id / p ,t ^ 3 e 't_ L 04- , e /e.,,. jurisdiction's fee schedule for residential permit fee. City /county: I ZIP: Gj 7 2z 1 & 2 FAMILY DWELLING PERMIT FEE SCHEDULE Description and location of work on premises: �,c, s i7Z`c A crz v AND COMMERICAL/INDUSTRIAL EQUIPMENT SCHEDULE d ■ Al /172.0u a U ,>' i0 ie Sys TR.Ai Fee(ea.) Total Est. date of completion/inspection: Description Qty. Res. only Res. only Tenant improvement or change of use: HVAC: Is existing space heated or conditioned? 0 Yes ❑ No Air handling unit CFM space insulated? ❑ Yes 0 No Air rati conditioning existing plan required) Is existing P Alteration of existing HVAC system MECHANICAL CONTRACTOR Boiler /compressors cJ/ .i..- 4.., c_ State boiler permit no.: Business name: X O C HP Tons BTU /H Address: 2/ c/ L Ll . K (t.- / /0 6 g cv o "WM' Fire /smoke dampers/duct smoke detectors City: P Z ,'-"u D I State2(eI ZIP:Q 7 Z/ 7 Heat pump (site plan required) Phone: Zi 5-- / s- Fax: ZJS" -/ S t4 E -mail: ' Install/replace furnace/burner BTU /H Including ductwork/vent liner ❑ Yes O No CCB no.: /0 - 7gc Install/replace/relocate heaters - suspended, City /metro lic. no.: G O CJ 3 e Lis-7 wall, or floor mounted Name (please print): t c c _ ! ie. p-- Vent for appliance other than furnace CONTACT PERSON Refrigeration: . Absorption units BTU/H /'' Chillers HP Name: ei2 / C-/< / � w U-' Compressors HP Address: 0 7/v Z A_.). X ti G s 4.1 0 2vW Environmental exhaust and ventilation: City: Q /2 f'Z 4 ,u P I State:0 ZIP: 7 a / 7 Appliance vent Phone:24 S'3 t.( Fax:215 5'l. E -mail: Dryer exhaust OWNER Hoods, Type 11 II/res. kitchen/hazmat hood fire suppression system Name: Sibs /r3 if ,A.) eC At S"H-/ p / Exhaust fan with single duct (bath fans) Mailing address: 30 <5•Ci /y4-2-4..- 6'4„J1/7 Exhaust system apart from heating or AC City: , rc 0 I State:CJKI ZIP: � 7 Z a 3 Fuel piping and distribution (up to 4 outlets) T // Type: LPG NG Oil Phone: L V4/, G 7 Fax:CZ 7 - 6;gf' -mail: Fuel piping each additional over 4 outlets Process piping (schematic required) Number of outlets Name: �[� � C.J Other listed appliance or equipment: Address: Decorative fireplace City: I State: I ZIP: Insert - type Phone: I Fax: I E -mail: Woodstove /pellet stove Other: Applicant's signature: I Date: Other: Name (print): Not all jurisdictions accept credit cards, please call jurisdiction for more information. Permit fee $ 003 ❑ visa ❑MasterCard Notice: This permit application Minimum fee $ Credit card number: / / expires if a permit is not obtained Plan review (at %) $ 1 Expires within 180 days after it has been State surcharge (8 %) .... $ 4 Name of cardholder as shown on credit card accepted as complete. TOTAL $ Cardholder signature Amount 440-4617 (6/00 /COM) MECHANICAL PERMIT FEES • COMMERCIAL FEE SCHEDULE: 1 & 2 FAMILY DWELLING FEE SCHEDULE: TOTAL VALUATION: FEE: Description: Price Total Table 1A Mechanical Code Qty (Ea) Amt $1.00 to $5,000.00 Minimum fee $72.50 1) Furnace to 100,000 BTU $5,001.00 to $10,000.00 $72.50 for the first $5,000.00 and including ducts & vents 14.00 $1.52 for each additional $100.00 or 2) Furnace 100,000 BTU+ $10,000.00. fraction thereof, to and including including ducts & vents 17.40 $ $10,001.00 to $25,000.00 $148.50 for the first $10,000.00 and 3) Floor Furnace including vent 14.00 fraction $1.54 r each thereof, , additional to an nal d including or 4) Suspended heater, wall heater n r, to and ) p 14.00 $25,000.00. or floor mounted heater $25,001.00 to $50,000.00 $379.50 for the first $25,000.00 and 5) Vent not included in appliance permit $1.45 for each additional $100.00 or 6.80 fraction thereof, to and including 6) Repair units $50,000.00. 12.15 $50,001.00 and up $742.00 for the first $50,000.00 and Check all that apply: Boiler Heat Air $1.20 for each additional $100.00 or For items 7 -11, see or Pump Cond fraction thereof. footnotes below. Comp ** 7) <3HP;absorb unit to 100K BTU 14.00 ASSUMED VALUATIONS PER APPLIANCE: 8) 3 -15 HP; absorb Value Total unit 100k to 500k BTU 25.60 Description: Qty (Ea) Amount 9) 15 -30 HP; absorb Furnace to 100,000 BTU, including 955 unit .5 -1 mil BTU 35.00 ducts & vents 10) 30 -50 HP; absorb Furnace > 100,000 BTU including 1,170 unit 1 -1.75 mil BTU 52.20 ducts & vents 11) >50HP: absorb Floor furnace induding vent 955 unit >1.75 mil BTU 87.20 Suspended heater, wall heater or 955 12) Air handling unit to 10,000 CFM floor mounted heater 10.00 Vent not included in applicance 445 13) Air handling unit 10,000 CFM+ permit 17.20 Repair units 805 14) Non - portable evaporate cooler < 3 hp; absorb. unit, 955 10.00 to 100k BTU 15) Vent fan connected to a single duct 3 -15 hp; absorb. unit, 1,700 6.80 101k to 500k BTU 16) Ventilation system not included in 15 -30 hp; absorb. unit, 501k to 1 2,310 appliance permit 10.00 mil. BTU - 17) Hood served by mechanical exhaust 30 -50 hp; absorb. unit, 3,400 10.00 1 -1.75 mil. BTU . 18) Domestic incinerators >50 hp; absorb. unit, 5,725 17.40 >1.75 mil. BTU 19) Commercial or industrial type incinerator Air handling unit to 10,000 cfm 656 69.95 Air handling unit >10,000 cfm 1,170 20) Other units, including wood stoves Non - portable evaporate cooler 656 10.00 Vent fan connected to a single duct 446 21) Gas piping one to four outlets Vent system not included in 656 5.40 appliance permit 22) More than 4 -per outlet (each) Hood served by mechanical exhaust 656 1.00 Domestic incinerator 1,170 Minimum Permit Fee $72.50 SUBTOTAL: $ Commercial or industrial incinerator 4,590 Other unit, including wood stoves, 656 8% State Surcharge $ inserts, etc. Gas piping 1-4 outlets 360 25% Plan Review Fee (of subtotal) $ Each additional outlet 63 Required for ALL commercial permits only TOTAL COMMERCIAL $ TOTAL RESIDENTIAL PERMIT FEE: I $ VALUATION: Other Inspections and Fees: 1. Inspections outside of normal business hours (minimum charge -two hours) $72.50 per hour. 2. Inspections for which no fee is specifically indicated (minimum charge -half hour) $72.50 per hour 3. Additional plan review required by changes, additions or revisions to plans (minimum charge -one -half hour) $72.50 per hour * State Contractor Boiler Certification required for units >200k BTU. ** Residential A/C requires site plan showing placement of unit. is \dsts \forms\mech- fees.doc 10/11/00