Loading...
Correspondence H u u u u u Ll u u u u u u u u u Ll u u M T T E S O N • A R C H I T E C T S u April 16, 1996 Mr. James Funk, Plans Examiner City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Re: WAREHOUSE DEVELOPMENT 510 NW THIRD 8250 SW Hunziker Road PC3 -18C SIT96 -0014 PORTLAND OREGON 97209 503 224 6145 Dear Mr. Funk; I have forwarded a copy of your letter dated April 12, 1996 to the owner, Mr. James Severson, for response to items 1 thru 5. I offer the following comments to Item #6 and the Accessibility items #1 thru #3: Item #6: Roof area of the building is 12, 692 square feet; Paved parking area is 9,593 square feet; and Sidewalk area is 771 square feet. There is no 'dock loading facility'. Accessibility Item #1: All building entrances are accessible with 1/2" thresholds. Parking surfaces and accessible route from designated parking spaces are at the same elevation as the floor level, i.e., no curb. There is no 'pubic sidewalk' serving this site. The 'public street' serving the site accesses the designated accessible parking spaces. This meets the accessibility requirements and no detail is required. Item #2: The new sidewalks do not have 'curb ramps' - these walks taper at the ends at a ratio of 1 :20 and do no qualify as a ramp. No detail is required. Item #3: Designated accessible parking spaces are shown with the international handicapped symbols and stripped loading area on the site plan. Attached is a copy of ODOT's drawing for dimensions of symbols and lines. The "van accessible" sign will be installed on the building. If it is acceptable to 'red mark' the drawings for the square footages of surface areas, sidewalk slopes, and attach the HC drawing, please let me know at your earliest opportunity as I do no want to hold up the permit process. Thank you for your assistance. Sincerer John L. a = on, A.I.A. cc Jim Severson, Centrex Construction 'v ' )- %, r VIN V IV S - AN Sal E 0 OBLE-DISABLD P`RSG\ PARKING SPACE (8, . PAR[DK, xiTH OJ .Y. OtSA8LE4 PERuCT ONLY VIOLATORS S.U! CT TO . TOtNG LwOER ORS U.b?O WO FTNE • • -, LW TO 1470 ()HOER on mm srs VAN-ACCESSIBLE I' * OP,20 -6B * OR20 -6B,D 1. OR20-66.D • - - 4' • 0.• .., - Pain-red - � Stripes- - 2' i yp. 0 17' a' c-. \ -? r --j \ • ill (., ,--_____\ . co 7-7\ IV _._—' --J LL 1 c.6 I I • o. - 1 - -24' min, - f 9' ! a' PAVEvIENT STENCIL WHITE Either but not both • BLUE BACKGROUND AND BLJE PAINTED CURB OPTIONAL u u u u u u u L1 Ll u LI u u Li L1 u u u IJ M A T T E S O N • A R C H I T E C T S April 24, 1996 Mr. James Funk, Plans Examiner City of Tigard RECEIVED 13125 SW Hall Blvd. Tigard, OR 97223 APR 2 41996 Re: WAREHOUSE DEVELOPMENT COMMUNITY DEVELOPMENT slo NW THIRD 8250 SW Hunziker Road PC3 -18C SIT96 -0014 PORTLAND OREGON 97209 503 224 6145 Dear Mr. Funk; Attached are three (3) copies of the revised Site Plan dated 4 -23 -96 with the following revisions per your letter dated April 12, 1996 and our phone conversation of April 19, 1996: V utility information indicating location, size, type and slope of piping for sanitary sewer, storm sewer and catch basins and potable water. down spouts are connected downstream of the catch basin. 3' erosion control is indicated by small scale site plan indicating sediment fence location and applicable detail for fence. t/ square footage for impervious surface is indicated under 'Project Data'. the sidewalks are indicated to slope at the ends @ 1:20 with tactile texture as HC access warning. l HC parking stripping is indicated by added schematic drawing and signage is noted. Other items of your letter are addressed by my letter dated April 16, 1996 and Mr. James Severson's (owner) letter dated April 17, 1996. Regarding handicap access from a public street - it is my opinion that the northeast end of our new sidewalk (property line) is the extent of development responsibility for HC site access. Please call if you have any questions. It is my understanding that this completes the requested information and a permit may be issued. Thank you for your assistance. Since John L. on, A._.A. cc Jim Severson, Centrex Construction Pr Akk April 12, 1996 CITY OF TIGARD OREGON Matteson Architects 510 NW Third Portland, OR 97209 Re: WAREHOUSE DEVELOPMENT 8250 SW Hunziker Road PC3 -18C SIT96 -0014 The plans and specifications have been reviewed for conformity to applicable codes. Please submit three (3) sets of revised plans and specifications incorporating the following requirements: V q ( Site `► % The storm drainage s plan shall adequately address the number of catch basin required to handle the parking lot and b hard surface runoff. The Uniform Plumbing Specialty Code (UPSC) Section 1408 allows a maximum 6" outlet on each catch basin, and Table 14 -2 limits the maximum surface area one catch basin can serve to 7,133 square feet at a 1% slope of the horizontal line from the catch basin. Additional catch basins are required to adequately serve the area. Y Provide a utility plan showing the location, size, type, and slope of piping for sanitary sewer, storm sewer and catch basins, and potable water. 4q . Flow - through catch basins are not permitted. Connect the �' roof down -spout drain system downstream of the catch basin. --._._______ +/ Catch basins shall be trapped by using an inverted one - quarter bend or welded baffle. Provide catch basins constructed to OSPC Section 1408 specifications. e. Fill placed on property which is to support the foundation of any building shall be placed in accordance with accepted engineering practice. .ubmit a s.oi1 is estigation report and a report from an approved testing agency of satisfactory placement of fill [Section 2903, and City Ordinance 4224]. • Provide an erosion control plan and details of protection in accordance with the Unified Sewerage Agency requirements. • Contact the Fire Marshal at 526 -2502 in regards to fire apparatus access and turn - around requirements. Provide a copy of their requirements. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Matteson Architects April 12, 1996 pg. 2 Submit the cost of providing each category of site preparation including, but not limited to: A. Site preparation. B. Grubbing and grading. C. Utilities. D. Storm, sanitary, fire hydrants, fire sprinkler, and domestic water piping. E. Paving. F. Curbs and sidewalks. G. Erosion control. H. Retaining walls and railing. I. Landscaping. J. Lighting. V. / K. Accessibility requirements. Provide the total square footage of impervious area for the building, parking lot, sidewalks, and dock loading facilities. Accessibility At least one accessible route shall be provided within the boundary of the site from the public street or sidewalk to an accessible building entry [OSSC, section 3103(a)]. Provide details. Curb ramps shall be constructed in accordance with requirements in OSSC, Section 3103(b). Provide a detail / within the plan. Accessible parking stalls for the disabled shall have signs and pavement markings of the international symbol of accessibility clearly visible and designed to standards adopted by the Oregon Department of Transportation [Section 3104 (d) 9] . Ii. Signage for the parking stall for the disabled shall include a separate "van accessible" sign mounted below the sign [ORS 447.233 (2) e] . If you wish to discuss any of these items, please give me a call. Sincerely, James Funk Plans Examiner sit96- 0014 \pc3 -18c CENTREX CONSTRUCTION INCORPORATED April 17, 1996 6 City of Tigard V 3 13125 SW Hall Blvd. S Tigard, OR 97223 1 / v Attention: James Funk Reference: WAREHOUSE DEVELOPMENT 8250 SW Hunziker Road PC3 -18C SIT96 -0014 Gentlemen: Enclosed is the response to your letter to Matteson Architects, dated April 12, 1996 regarding the above referenced project. Items #1 and #2 will be forthcoming. 1. Item #3; three (3) copies of the erosion controls plans. 2. Item #4; one (1) copy of the turn - around requirements. 3. Item #5; one (1) copy of the cost per category of site preparation. 4. Item #6; one (1) copy of Matteson Architect's letter with attachment, dated April 16, 1996. Respectfully submitted; James A. Severson warehouse \Funk#2.a17 Attachments 8250 S.W. HUNZIKER RD. • TIGARD, OREGON 97223 -5060 • TELEPHONE (503) 684 -0443 • FAX (503) 620 -6692 Hunziker Road Warehouse Warehouse Shell 8250 SW Hunziker Road City of Tigard Tigard Oregon 97223 FirstReview April 25, 1996 Page 1 Hunziker Road Warehouse Shell City of Tigard LP Job No. 96522.020 City No. BUP -96 -0151 JOHN L. MATTESON ARCHITECTS MATTESON ARCHITECTS 510 NW THIRD AVE. PORTLAND, OR 97209 FAX (503) 223 -0342 RE: FIRST PLAN REVIEW HUNZIKER WAREHOUSE SHELL LINHART PETERSEN POWERS ASSOCIATES has reviewed plans for the above project: • Plans Set Pages 1 through 3 of March 22, 1996 sealed by Oregon Architect John L. Matteson. • Eight page "Slab & Foundation Details" report of March 11, 1996 sealed by Roger McGarrigle, P.E., Oregon Engineer 7160. • Plans for steel building from Pacific Building Systems, stamped February 21, 1996, and sealed by Arlie M. Lenhardt, P.E., Oregon Engineer 7139. This plan set includes: General Notes, sheets 1 through 7, D1, D3, SFW -1, Fl, and F2. • Structural calculations for steel building from Pacific Building Systems, stamped February 21, 1996, and sealed by Arlie M. Lenhardt, P.E., Oregon Engineer 7139, about 15 pages. This review is based on the 1993 Edition of the State of Oregon Structural Specialty Code and all citations are from this code unless otherwise noted. The review is for a shell building only and was not reviewed for high -piled storage defined in the Fire Code. GENERAL: Group B, Division 2 Occupancy. Type V -N Construction (sprinkled). Base area: 12,600 square feet. Stories 1. Occupancy load: Big Space: 17 Small Space: 9 Parking 26 spaces, one van and one non -van required. Two van stalls provided. LINHART PETERSEN POWERS ASSOCIATES 3855 -3 Wolverine Street NE • Salem, OR 97305 (503) 371 -2212 • FAX: (503) 371 -3853 • Hunziker Road Warehouse Warehouse Shell 8250 SW Hunziker Road City of Tigard Tigard Oregon 97223 FirstReview April 25, 1996 Page 2 1. Site storm sewer catch basins shall comply with the design provisions in the State Plumbing Code, Chapter 14. Cleanouts shall be provided at the base of all building raindrains. 2. All deferred submittals, such as the fire sprinkler system, mechanical system, plumbing and the electrical systems, shall be reviewed and approved by the architect of record before submitting for review to the building department. Section 302 (b). FIRE AND LIFE SAFETY: 1. The exterior one -hour walls shall be listed assemblies of an approved testing agency. Section 4302 (b). 2. The fire sprinkler system shall be designed for a shell building at Ordinary Hazard Group 2 over an area of 3,000 square feet. Section 3802. 3. The proposed fire department connection shall be located a minimum of 40 feet away from the building exterior wall and within 70 feet of a public fire hydrant. Additionally, such fire department connection shall be approved by the Tualatin Fire and Rescue Fire Chief. Oregon Fire Code, Article 10. STRUCTURAL: 1. Special inspections for steel high strength bolting shall be provided as required in Section 2709 of the code. The engineer shall determine if such special inspections are required. Section 306 (a) 6. DISABLED ACCESS: 1. Provide an accessible route leading from the existing public sidewalk to the main entry of the new building. Section 3103 (a). 2. Signs are required for disable parking stalls. Signage language for disable parking stalls by Oregon statute. The message on the sign shall read: "PARKING WITH D.M.V. DISABLED PERMIT ONLY VIOLATORS SUBJECT TO TOWING UNDER ORS 811.620 AND A FINE OF UP TO $470 UNDER ORS 811.615." An additional sign shall appear under the above sign reading: "VAN- ACCESSIBLE." These signs shall comply for color, size and character size with standards of the Oregon Transportation Commission. See ORS 447.233 (f). ENERGY CONSERVATION: 1. Documentation is required by Section 5301 (c) showing complacence with energy conservation requirements. This documentation shall be on forms approved by the Building Codes Division administrator. LINHART PETERSEN POWERS ASSOCIATES V L 3855 -3 Wolverine Street NE • Salem, OR 97305 (503) 371 -2212 • FAX: (503) 371 -3853 Hunziker Road Warehouse Warehouse Shell 8250 SW Hunziker Road City of Tigard Tigard Oregon 97223 FirstReview April 25, 1996 Page 3 2. Perimeter slab -edge insulation is not provide. Slab -edge insulation may be avoided by alternate insulation systems authorized by Section 5301 (d). Document is required as provided in Section 5301 (c). PLAN REVIEW COMMENTS WOULD NOT PRECLUDE THE ISSUANCE OF A FOOTING AND SLAB PERMIT FOR THIS PROJECT. Respectfully, LINHART PETERSEN POWERS ASSOCIATES GARY LAMPELLA Plans Examiner Of_t! WALTER M. FRIDAY, P.E. Plans Examiner c: Jim Severson, Centrex Construction Inc., FAX (503) 620 -6692 Dave Scott, Tigard, Building Official, FAX (503) 684 -7297 L INHART PETERSEN POWERS ASSOCIATES tv oi 3855 -3 Wolverine Street NE • Salem, OR 97305 (503) 371 -2212 • FAX: (503) 371 -3853