Loading...
Correspondence . R e me er mechanical C.C.B. NO. 63242 • 7051 S.W. SANDBURG ST. • SUITE 400 • TIGARD, OREGON 97223 -8011 • (503) 603 -0205 • FAX (503) 603 -0150 • April 9, 1997 Mr. Robert Poskin, CBO City of Tigard 13125 S.W. Hall Blvd. Tigard, OR 97223 Subject: Mechanical Plan Review PC # =1 -26C MEC #97-0007 Project: Madison Plan Review 7805 S.W. Hunziker Dear Mr. Poskin, We have reviewed your comments in your plan review letter for referenced project and believe the attached revised copies of documents should comply. Please review and advise. Sincerely, William F. Craig Project Manager RECEIVED APR 0 9 1997 COMMUNITY DEVELOPMENT 24 Hour - 7 Day Service Industrial • Commercial • Service • Installation • Maintenance Controls • Heating • Air Conditioning • Refrigeration • Boiler • r CITY OF TIGARD January 17, 1997 OREGON Reitmeier Mechanical 7051 SW Sandburg Tigard, OR 97223 RE: Madison Furniture Mechanical Plan Review 7805 SW Hunziker PC #: 1 -26c MEC #: 97 -0007 Submittal documents for the above referenced project have been reviewed for conformance with the applicable 1996 Oregon Specialty Codes and other applicable - _ _ codes and standards. The following items require your attention: ; _ 1. . - Provide an en analysis of each structural member supporting_ the T -- additional HVAC units [OSSC, Section 106.3.2]. _ :. 2. : " The attachment of permanent equipment (HVAC) supported by the building's'` - _.:_:.:�.•.__:.__.- .- ___ _,: structural components shall be designed to resist the total design seismic forces ... prescribed in Section 1603.2 of the Structural Specialty Code. Provide an -- • .. - - engineer's design specifying attachment requirements [OSSC Section' 160.3.2 - - and OMSC, Section 304.4]. ..- : _ _: .- 3..__Y- The area where the 36° x 36° eyebrow is penetrating is of one -hour construction; - _ .: -- therefore, a one -hour fire damper shall be required. _ . _. . , z w._.. w _ _ • • Please submit three copies of revised submittal documents and a letter indicating your response to the above comments for review. Please call me at (503) 639 -4171 if you have any questions. Sincerely, U-� Ro ert Poskin, CBO PLANS EXAMINER T :1PRMSYS1DOCUMENTMECY7_00.07TPC 1.26C.DOC 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772