Loading...
Plans 7,.3 Si✓ )hzi cer t ( 47-?v? S' HILLTOP 7320 2ND FLOOR FIRE ALARM OUTPUT ADDITIONS 4 -27 -07 Junction TO PANEL NAC 3 5808 Silent Knight Box Fire Control Panel 2nd Fl. CO E, HALL HORN STROBE 15/75 CD 90MA 0 WOMEN'S RR STROBE 15CD 79 MA 411 MID HALL HORN STROBE 15/75 CD 90MA MEN'S RR STROBE 15CD 79 MA 0 LOBBY HORN STROBE 30CD 107MA HILLTOP 7320 2ND FLOOR FIRE ALARM INPUT ADDITIONS 4 -27 -07 Junction TO PANEL SLC 5808 Silent Knight Box Fire Control Panel 2nd Fl. E. HALL PULL STATION PS MIM ADDRESSABLE INPUT MODULE SD HALL CORNER SMOKE DETECTOR SD MID HALL SMOKE DETECTOR SD ELEVATOR SMOKE DETECTOR SD WEST HALL CORNER SMOKE DETECTOR LOBBY PULL STATION PS WITH MIM ADDRESSABLE INPUT MODULE - Global Project Values: SILENT Project Name: HILLTOP 7320 Standby Hours:1 24 KNIGI Ir' Project ID:12nd floor buildout Alarm Mins:1 5 Prepared By:IRICH MILLER Derating Factor:1 1.2 5808 Calculations Date: 14/27/2007 Voltage Drop Warning Threshold % :I 10 Panel ID: 15808 1 Model: 5808 Add. Fire Alarm Control Panel Max NAC Current: 3.0 Amps Location: (closet on 1st floor 1 Volts: 24 VDC Max Panel Current: 5.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ o Ckt.# Circuit Name Qty /oDrop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 5808 5808 CTRL Panel 1 0.170 0.325 SLC -DEV Addrsbl SLC Devices 40 0.022 0.022 5860 LCD Remote Annunc 1 0,020 0.025 5824 Serial /Parallel Module 0.000 0.000 5496 Power Expander 0.000 0.000 5865 -4 LED Annunciator (4G) 0.000 0.000 5865 -3 LED Annunciator (3G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 Other 0.000 0.000 Other 0.000 0.000 SD -Duct Duct Hsg w /Relay 0.000 0.000 5883 Relay Module 0.000 0.000 PGM -I /O #1 Notification Appl Circuit 0.000 0.766 #16 Solid 4.02 272 2.19 18.72 8.21% PGM -I /0 #2 Notification Appl Circuit 0.000 0.794 #16 Solid 4.02 242 1.95 18.86 7.57% PGM -I /O #3 Notification Appl Circuit 0.000 0.719 #16 Solid 4.02 296 2.38 18.69 8.39% PGM -I /0 #4 Notification Appl Circuit 0.000 0.012 #16 Solid 4.02 88 0.71 20.39 0.04% Aux Power *1 # of NAC's Used 0.000 0.000 Total Standby Current (Amps) 0.212 2.663 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 5.088 0.222 Total Alarm AH Required Total Combined AH Required 5.31 Command Shortcuts Multiply By The Derating Factor 1.20 l Minimum Battery AmpHours Required 6.37 Configure Circuits I Print Page J JJJ #1. Note: A value msut be entered if ou have selected an NAC circuits as AUX Power. American Security Alarms, Inc. 5411 SE McLoughlin Blvd., Portland, OR. 97202 (503) 231 -0303 PROPOSAL COMMERCIAL SECURITY ALARM SYSTEM Attn: Brad McCoy April 2, 2007 Robinson Construction RE: Hilltop Building - 2 Floor 7320 Hunziker, Oregon City Additions to Existing Fire Alarm System Upgrade for 2 " Floor 1. Install Additional Fire Warning Devices: 3 - Ceiling Mount Fire Horn Strobe Light Devices in Common Hall Area. 2 - Fire Strobe Lights in Bathroom Room Area 2. Install Additional Smoke Detectors: 1 - Smoke Detector in Elevator Area (Elevator Recall Type) 2 - Smoke Detectors in Hall Area 3. Install (2) Pull Stations near Stair Well Areas E S Tl r' G - 5808 Si 14 c 7 4. Connect new Fire Alarm Sensors & Devices into Exi< g-Ho ey U V a 12 Fire Control Panel, and Check for proper operation. Note: Connections to any Duct Detectors on 2 Floor will be additional cost. Installation: $1,920.00 Equipment & Labor $ 594.00 Fire Life & Safety Permit, Plan Preparation & Submittal $ 81.00 Electrical Permit $2,595.00 Completely Installed, all Labor & Materials Includes a one year warranty on all parts and labor Proposal is subject to approval of Authority having Jurisdiction. Customer is responsible for additional requirements made by Authority having Jurisdiction upon plan review or inspection. Approved: Date: 503 -231 -0303 - Please call if you have any questions 503 - 230 -1044 - Fax - If you would like to proceed, please sign above and fax to our office. Upon receipt, our scheduler: Ken Schwander will contact you to set a time for the work James D. Liston Security /Fire Alarm Consultant THE SECURITY PROFESSIONALS...SINCE 1970 INTELLIKNIGHT FIRE ALARM CONTROL PANEL &14 Paw7 -oo z 33 IntelliKnight 5808 Single Loop Addressable Fire Alarm' Control System l r� The convenience of an addressable fire t. „ alarm control panel in a cost - effective easy to use package. IntelliKnight Model 5808 is a 127 point class leading single loop addressable fire alarm control /communicator system. 5808 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built -in digital communication, distributed intelligent power, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1- 800 - 446 -6444, or in Minnesota, call 763 - 493 -6435. Description • Built -in synchronization for 5808 performs drift compensation and appliances from AMSECO, Gentex®, calibration checks on each of the Faraday, System Sensor®, and Wheelock® sensors in the system. • One Form C trouble relay rated at The basic 5808 system can be 2.5A at 27.4 VDC and two Form C , enhanced by adding modules such as programmable relays rated at 2.5A at 5860 remote annunciator, 5824 27.4 VDC serial /parallel printer interface module •Programmable date setting for (for printing system reports), and 5496 Plex-2 Saving Time • Plex -2 door option combines a dead intelligent power module. 5808 also front cabinet door with a clear features a powerful built -in dual line fire window, limiting access to the panel communicator that allows for reporting while providing single button of all system activity to a remote operation of the reset and silence monitoring location. functions Electrical Specifications 111-1!, Features ..,_M- • Up to 127 addressable points Primary AC: 120 VRMS at 50/60 Hz, • Up to 125 zones and 125 output 2.75A Model 5808 groups Total Accessory Load: 6A @ 27.4 VDC • Uses standard wire —no shielded or Notification Power: 6A @ 27.4 VDC, FCC Part 15 and Part 68 approved twisted pair required • Built -in digital communicator power- limited Type of Jack: RJ31X (two required) • Central station reporting by point or Standby Current: 170 mA Approvals by zone Alarm Current: 325 mA NFPA 13, NFPA 15, NFPA 16, NFPA • Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC Notification & Auxiliary Circuits: 70, & NFPA 72: Central Station; • Distributed, intelligent power 3A @ 27.4 VDC per circuit, Remote Signalling; Local Protective • Drift compensation power - limited Signalling Systems; Auxiliary Protected • 13 pre - programmed output cadences, Battery Charging Capacity: 7.0 -35.0 AH Premises Unit; & Water Deluge (including ANSI - 3.41), and 4 Releasing Service. Suitable for programmable outputs Battery Size: 18 AH max. allowed in • Notification circuits can be configured FACP. Larger capacity batteries can be automatic, manual, waterflow, sprinkler as 2 Class A (Style Z) or 4 Class B housed in an RBB accessory cabinet supervisory (DACT non - coded) (Style Y), or auxiliary power for signalling services. resettable, constant, or door holder Mechanical Specifications Other Approvals: UL Listed; power Flush Mount Dimensions: pp • Built -in annunciator with 80- character 14.5" W x 24.75" H x 3.5" D CSFM 7170 -0559: 142; LCD display MEA 429 -92 -E Vol. XIV • RS-485 bus provides communication (36.8 W x 62.9 H x 8.73 D cm) to system accessories Overall Dimensions: • Built -in RS -232 and USB interface for 16" W x 26.4" H x 4.65" D programming via a PC (40.6 W x 67 H x 11.8 D cm) SILENT • Upload or download programming, event history, or detector status via Weight: 28 lbs. (12.8 kg) l it KNIGHT remote or direct connection Color: Red r • Improvements in SKSS deliver five times faster upload /downloads Telephone Requirements: by Honeywell KNIGHT FIRE ALARM CONTROL PANEL SLC Detectors SLC Modules 5880 LED/I0 Module SD505 -APS Model SD500 -AIM Features 40 LED Addressable photoelectric smoke detector. Dry contact input module for use with outputs, 8 normally normally open dry contacts. It features an open dry contact inputs S indicator LED to status. and one piezo output. i' ii o show alarm Addressable ionization smoke detector. SD500 -MIM 5865 -3 and 5865 -4 SD505 -AHS Remote LED Absolute temperature heat detector that Mini dry contact input module is a small Annunciator 1 goes into alarm immediately if the version of the SD500 -AIM. For use with pull Features 30 temperature exceeds the programmable trip stations and other normally open dry contact programmable LED (15 point. Trip point range from inputs. red and 15 yellow) outputs and a piezo 135 °F - 150 °F(0 °C- 37 °C). SD500 -ANM sounder. The 5865 -4 adds a silence and Addressable notification module providing a reset switch to the package. S single Class A or Class B notification circuit 5883 Relay Board Six x inch inch base base for use with detector heads on the SLC. Features 10 general purpose Form C relays. SD505 -APS, SD505 -AIS and SD505 -AHS. Used with 5880 module. SD505 -4AB SD500 -ARM Four inch base for use with detector heads Addressable relay module that features two 5824 Serial /Parallel Printer SD505-APS, SD505 -AIS, and SD505-AHS. Form C output relays. Provides indicator Interface Module LED to show output status. Provides one parallel and one RS -232 serial SD505 -6SB SD500 -SDM port for connecting a printer to 5808. Use to Six -inch sounder base for use with existing Two -wire detector input module. Allows for print a real -time log of system events, sensor and base. Operates in single and the connection of conventional 2 -wire detector status reports, and event history. multi- station modes and /or as a system detectors on the SLC loop. Requires two sounder. Requires 2 additional wires for additional wires for power. Miscellaneous Accessories power. SD505 -61B SD500 -LIM 5660 Silent Knight Software Suite Short circuit isolator base for SD505 -APS, A short circuit isolator module for SLC PC -base software for FACP programming. SD505 -AIS, and SD505 -AHS detectors. devices. When a short occurs on the SLC Upload and view panel account information, SD505 -6RB loop, it is detected as a trouble, but all SLC event history, and detector status. devices protected by the isolator module 5670 Silent Knight Software Suite Six -inch relay base for use with existing continue to operate. End -user facility management software sensor and base. Provides one Form C SD500 -LED allows viewing of detector status and event contact. An LED driver capable of driving 80 LEDs history via modem or direct connection. SD505 -ADH through the SLC loop. Up to 40 Piex -2 Door Duct housing that detects smoke in HVAC SD500 -LEDs can be used per system. Dead front cabinet door with clear window to ducts. limit access to the FACP. SD505 -ADHR S -BUS Accessories Duct detector base with relay. Provides 5860/R Remote Fire Annunciator RBB Form C alarm contact. For use with Features the same 80 character backlit LCD Remote Battery Box Accessory Cabinet. SD505 -APS and SD505 -AIS sensors. display keypad and firefighter's key switch Use if backup batteries are too large to fit Compatible with SD505 -DTS remote test as the 5808. 5860 is gray and 5860R is red. into FACP cabinet. Dimensions: switch. 16 "Wx10 "Hx6 "D 5496 Intelligent Power Module (406 mm W x 254 mm H x 152 mm D) SD500- PS /SD500 -PSDA A 6 amp notification power expander that SD505 -DTS SD500 -PS is a single action pull station and provides four additional power - limited SD500 -PSDA is a dual action pull station. notification appliance circuit outputs. Remote test switch that provides remote key operated test function and annunciation of detector alarm with SD505 -ADHR. aw ,1 MO - '' 11114 slJtL1 up 4. D IPStra MAWS f°$4 t 10 A mw »"`.« 9° I - - -_ ti kj.esr x �K mm� ( . «.w;x w I I usemlemwcawwe• 1 r . 4 ii _ 11 L ' i 1 eetlrow.jtoobeeuaeaw. 1 4 ' — • wort IV ". xtti = r- 5496 ti SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350386 Rev. D 04/06 b Honeywell subject to change without notice. For more information, contact Silent Knight Y Y 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2006 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. IntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight INTELLIKNIGHT ACCESSORY 111( Addressable ' " Photoelectric Type Smoke Detector Detect smoldering fires quickly and get help fast with IntelliKnight® photoelectric sm oke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505 -APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505 -APS compensates automatically for contamination in the environment. And detector testing is simple —even from a remote site. Like other IntelliKnight detector models, the SD505 -APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors —easy installation, stable operation, RF /transient protection, and vandal- resistant locking —and it adds up to a flexible solution for all your fire protection needs. - Model SD505 -APS The light received is converted into . "4-4 Analog / Addressable an electronic signal. Under normal Photoelectric Type conditions, the status LED blinks A Smoke Detector approximately every 15 seconds, The SD505 -APS is particularly indicating that the head is : ► suited to detecting dense smoke communicating with the loop. The � , � typical of fires involving materials LED lights continuously during the such as soft furnishings, plastic, alarm period. ' foam or other similar materials Features which tend to smolder and produce • Low profile, 2 inches, including SD505 -APS Smoke Detector large visible particles. base Specifications The detector features automatic • Simple and reliable addressing Operating Voltage: 17 - 41 VDC compensation for contamination without mechanical switches Current Consumption: and a simple detector calibration • Automatic compensation for test procedure that can be run from sensor contamination Standby: .55 mA the panel or remotely (using the • Built-in fire test feature Alarm: .55 mA WindowsTM based downloading • Simple detector calibration Ambient Temperature: 32 °F to 120 °F software). testing through the control panel (0 °C to 49 °C) Operation or remotely through a Mounting: 4" Square, 4" The SD505 -APS units made up of WindowsTM based computer OCT, Single an LED light source and a silicon software. gang mud ring photo diode receiving element. In a • Vandal- resistance locking Relative Humidity: 85% normal standby condition, the features noncondensing receiving element receives no light • Field cleanable from the pulsing light source. In the Air Velocity: 0 - 300 FPM UL listed, meets NFPA 72 Ch 7 event or fire, smoke enters the Compatible Bases: SD505 -6AB requirements Sold Separately) ( ) detector and light is reflected from (Sold approved (6" Base) smoke particles to the receiving SD505 element. • MEA approved (4" Base) • FM Approved SILENT TO KNIGHT by Honeywell HT ACCESSORY Model SD505 -APS Addressable Photoelectric Type `R Smoke Detector , L i Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505 -APS. The combination detector head, and twist -lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505 -AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505 -APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. hi Diameter =5 -15/16" N /_ ~r - -- -- - Diameter= 3- 15116" 14 N o 7 '`,-,,,,,, ( A, •° i! , ! f(7r) p a Height =2 inches, including base Go \\N„...,...„____FrAirrwri 0 Model SD505 -6AB Detector Base Model SD505 -APS Detector Head (front view) (front view) El SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350225 Rev C,. 05/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2005 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. INTELLIKNIGHT ACCESSORY SD500 -AIM & SD -500 -MIM tl Addressable Input Modules ' ' IntelliKnight's addressable contact monitor modules combine fast response with pinpoint 5 - . - . - :.! .7: location ID. A combination that saves lives and property. .4,-1.. The SD500 -AIM and SD500 -MIM are addressable input modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SD500 -AIM and SD500 -MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500 -AIM addressable input module mounts to a 4 "- square box. The SD500 -MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500 -AIM and SD500 -MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation —a flexible solution for all your fire protection needs. For more information about the IntelliKnight system, or to locate your nearest source, please call 1 -800- 446 -6444, or in Minnesota, call 763- 493 -6435. Description • Up to 2500 ft wiring distance from The SD500 -AIM and SD500 -MIM are either input module to contact addressable input modules for use with • Use up to 14 gauge wire the Intelliknight fire alarm control • UL listed ra panels (FACPs). The SD500 -AIM " ;, addressable input module mounts to a Electrical Specifications pM. Y4 , >, 4 "- square box. The SD500 -MIM mini Standby Current: 0.55 mA input module fits inside a single gang Alarm Current: 23 mA max for one box. Both input modules are designed device; 46 mA max for two devices; to be used with pull stations, water flow 0.55 mA for each additional device SD500 -AIM switches, and other applications requiring dry contact alarm initiation Line Resistance: 500 max devices. Mechanical Specifications These modules are supervised, single SD500 -AIM Physical Description 4 input contact monitors. Using an EOL Dimensions: ' resistor, they monitor for alarm contact 4.9" W x 4.9" H x 1" D closures and for open circuit wiring (12.4 W x 12.4 H x 2.5 D cm) fault conditions. If a fault occurs in the Weight: 3.6 oz (120.1 g) SD500 -MIM wiring, the module alerts the FACP. Color: Ivory cover plate Each addressable input module is Approvals programmed with a unique signal line SD500 -MIM Physical Description NFPA 71 & NFPA 72 circuit (SLC) loop address. Dimensions: UL 864 1.5" W x 2.5" H x 0.7" D CSFM 7300 -0559: 132 Features (3.8 W x 6.4 H x 1.8 D cm) MEA 429 -92 -E Vol. IX • Single contact monitor Weight: 1.6 oz (45.4 g) FM Approved for use with the 5820XL • Support for Class A (Style 6 & Style Environmental 7) or Class B (Style 4) wiring Operating Temperature: • Attractive ivory cover plate with the 32 °F - 120 °F (0 °C - 49 °C) SD500 -AIM • Small and lightweight size allows for Humidity: ° flexible mounting options with the 10% - 93 /° non - condensing SD500 -MIM SILENT • DIP switch programmable for fast KNIGHT installation by Honeywell IGHT ACCESSORY SD500 -AIM & SD500 -MIM 2: Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500 -AIM or SD500 -MIM. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SD500 -MIM shall fit inside a single gang electrical box. The SD500 -AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4 "- square or double gang electrical box. The SD500 -AIM addressable input module must provide a monitor LED that is visible from outside the cover plate III . rim .tea.. ._.._- 1 ._.. . ,�„ } , - N I Wiring ix S uperv,sed i Power Unwed 1 , Ili being monitored 'T I j 1 g iii a a ' r a .) `) ' i ) 0 " a , cwt ( - — f ) C iv: *:`;' gat; Compatibility Ordering Information IntelliKnight 5820 FACP SD500 -AIM Input Module IntelliKnight 5808 FACP Addressable input module with ivory cover plate. IntelliKnight 5700 FACP SD500 - MIM Mini Input Module Addressable mini input module. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA N KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350231 Rev.C, 05/06 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2006 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. *11 .SYSTEM _.. SENSOR Selectable Output 4 sr Horns, Strobes, and Horn /Strobes SpectrA/err" Advance selectable-au rpu thorns, strobes, W - and horn /strobes are rich with features guaranteed to y cut installation times and maximize profits. SPECTF i� Iert arrewaxmayaffrA The SpectrAlert Advance series of notification appliances is Features designed to simplify installations, with features such as plug in • Electrically compatible with existing SpectrAlert products designs, instant feedback messages to ensure correct installation of individual devices, and 11 field - selectable candela settings for wall 'Automatic selection of 12 or 24 volt operation at 15 and 15/75 and ceiling strobes and horn /strobes. candela • Plug -in design When installing Advance products, first attach a universal mounting • Field selectable candela settings on wall and ceiling units: 15, 15/75, plate to a four -inch square, four -inch octagon or double -gang 30, 75, 95,110, 115, 135, 150, 177, 185 junction box. The two -wire mounting plate attaches to a single -gang . Same mounting plate for wall- and ceiling -mount units junction box. • Shorting spring on mounting plate for continuity check before Next, connect the notification appliance circuit wiring to the SEMS installation terminals on the mounting plate. •Tamper resistant construction • Outdoor wall and ceiling products rated from —40 °F to 151°F Finally, attach the horn, strobe or horn/strobe to the mounting plate • Design allows minimal intrusion into the back box by inserting the product's tabs in the mounting plate's grooves.The • Horn rated at 88+ dbA at 16 volts device will rotate into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place • Rotary switch for horn tone and three volume selections with a catch until it is secured with a captured mounting screw. • Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements The SpectrAlert Advance series includes outdoor notification • Outdoor products rainproof per UL 50 (NEMA 3R) appliances. Outdoor strobes and horn /strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for • Compatible with MDL sync module wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Agency Listings 7 7125- 1653:186(indoor strobes) EA ++� M 7,r:11::331:76 tDV1d 'i s WI 5 C V ,v' � I: ] (horn/5tfobe roved ch me/ww es) LISTED APPROVED a ICI '135- 16531891ho,ns.th *es} ;40 .,2272 ME ?.452 -'? £ I • SpectrAlert Advance Specifications Architect /Engineer Specifications General SpectrAlert Advance horns, strobes and horn /strobes shall mount to a standard 4 x 4x 11/2-Inch back box, 4-inch octagon back box or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 11/4-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync - Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field - selectable candela settings including 15,15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary- signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Hom /Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The hom /strobe shall be wired as a primary- signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens /reflector system. The horn shall have three audibility options and an option to switch between a temporal three - pattern and a non- temporal (continuous) pattern.These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn /strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor /weatherproof back box with half inch and three - fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at t Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 4"A, x 4 21/4-inch back box.The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical /Electrical Specifications Standard Operating Temperature 32 °F to 120 °F (0°C to 49°C) K Series Operating Temperature -40 °F to 151°F (-40 °C to 66 °C) Humidity Range 10to 93% non-condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage Range' 8 to 17.5 V (12V nominal) o Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8 "diameter x 2.5" high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) 561 x 4.7"W x 2.5"D (142 mm L x 119 mm W x 64 mm 0) Horn dimensions 5.61 x 4.7 W x 1.31)(142 mm L x 119 mm W x 33 mm D) Wati -mount back box skirt dimensions (885 -2, BBSW -2) 5.91 x 5.0"W x 2.20 (151 mm L x 128 mm W x 56 mm D) Ceiling -mount back box skirt dimensions (BBSC -2, BBSCW -2) 7,1 " diameter x 2.25" high (180 mm diameter x 57 mm high) Wall -mount weatherproof back box dimensions (SA -WBB) 5.71 x 5.1 x 2.00 (1 45 mm L x 130 mm W x 51 mm D) Ceiling -mount weatherproof back box dimensions (SA -WBBC) 7.1 "diameter x 2.0" high (180 rnm diameter x 51 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time varying power source that is used on some power supply and panel outputs. 2. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05 -0393-003 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8 -17.5 Volts 8 -17.5 Volts 16 -33 Volts Candela DC FWR DC R Sound Pattern dB DC FWR DC FWR Standard 15* 123 128 II 71 Temporal i ligh 57 55 69 75 Candela Range 15/75° 142 148 77 81 Temporal Medium 44 49 58 69 30* NA NA 94 96 Temporal Low 38 44 44 48 75* NA NA 158 153 Non - temporal High 57 56 69 75 95* NA NA 181 176 Non - temporal Medium 42 50 60 69 110 NA NA 202 195 Non - temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -wire Horn /Strobe, Standard Candela Range (15 -115 cd) 8 -17.5 Volts 16 -33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal mporal Medium 132 144 69 0 1 Temporal 194 212 218 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non - temporal High 141 152 91 100 116 176 201 221 229 Non - temporal Medium 133 145 75 85 102 163 187 207 216 Non - temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non- temporal High 142 161 103 112 126 181 203 221 229 Non- temporal Medium 134 155 85 95 110 166 189 208 216 Non - temporal Low 132 154 80 90 105 161 184 202 211 UL Max, Current Draw (mA RMS), 2 -wire Horn /Strobe, High Candela Range (135 -185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non - temporal High 255 270 303 309 Non - temporal High 233 248 275 281 Non - temporal Medium 242 259 293 299 Non - temporal Medium 219 232 262 267 Non - temporal Low 238 254 291 295 Non - temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed candela Horn and Horn /Strobe Output (dBA) ratings must be reduced in accordance with this table. 24 Volt Nominal Strobe Output (cd) 8 -17.5 16 33 Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at -40°F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 321 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 7 ' 4 Non - temporal High 82 82 88 88 93 92 100 100 95 70 5 Non - temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non - temporal Low 75 75 81 81 88 84 96 92 115 115 T Coded High 82 82 88 88 93 92 101 101 135 135 8 Coded Medium 78 78 85 85 90 90 97 98 150 150 9 Coded Low 75 75 81 81 88 85 96 92 177 177 'Settings 7, 8, and 9 are not available on 2 -wire horn /strobe. 185 185 A0`,-,1 +95 -1.1 SpectrAlert Advance Dimensions �4.7" 2.5"=. li Dia. �7p Dia. 1 in .. II - � 1� ��► Wall -mount horn /strobes Ceiling -mount horn/strobes 2.25+1 7.1" 5.05" 2.23 =M Di I 20" Dia. �- — I - Dia c ° ° / O O 0 o 4 \ \ h 1 � FIIIII 4lL 7.7" 5.98' '�' c II ° ® o /o O d / 0 0 "' O I � / `` l \ �` \ r I~ 5.1 - - 4 Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model Description Model Description Wall Hom/Strobes Ceiling Hom /Strobes (cont d.) P2R *' 2 -wire Horn/Strobe, Standard cdt, Red PC2W*t 2 -wire Horn/Strobe, Standard cd, White P2RH* 2 -wire Horn /Strobe, High cd, Red PC2WH *t 2 -wire Horn /Strobe, High cd, White P2RK* 2 -wire Horn /Strobe, Standard cd, Red, Outdoor PC4R 4 -wire Horn /Strobe, Standard cd, Red P2RHK* 2 -wire Horn /Strobe, High cd, Red, Outdoor PC4RH 4 -wire Horn /Strobe, High cd, Red P2W* 2 -wire Horn /Strobe, Standard cd, White PC4RK 4 -wire Horn /Strobe, Standard cd, Red, Outdoor P2WH* 2 -wire Horn/Strobe, High cd, White PC4RHK 4 -wire Horn /Strobe, High cd, Red, Outdoor P4R* 4 -wire Horn/Strobe, Standard cd, Red PC4W 4 -wire Horn/Strobe, Standard cd, White P4RH* 4 -wire Horn /Strobe, High cd, Red PC4W1 I 4 -wire Horn/Strobe, ugh cd, White P4RK 4 -wire Horn /Strobe, Standard cd, Red, Outdoor Ceiling Strobes P4RHK 4 -wire Horn /Strobe, High cd, Red, Outdoor SCR* Strobe, Standard cd, Red P4W* 4 -wire Horn/Strobe, Standard cd, White SCRH* Strobe, High cd, Red P4WH* 4 -wire Horn /Strobe, High cd, White SCRK Strobe, Standard cd, Red, Outdoor Wall Strobes SCRHK Strobe, High cd, Red, Outdoor SR*l Strobe, Standard cd, Red SCW*t Strobe, Standard cd, White SRH *t Strobe, High cd, Red SCWH *r Strobe, High cd, White SRK Strobe, Standard cd, Red, Outdoor Horns SRHK Strobe, High cd, Red, Outdoor HR Horn, Red SW* Strobe, Standard cd, White HRK Horn, Red, Outdoor SWH* Strobe, High cd, White HW Horn, White Ceiling Hom /Strobes Accessories PC2R* 2 -wire Horn /Strobe, Standard cd, Red BBS-2 Back Box Skirt, Wall, Red PC2RH* 2 -wire Horn/Strobe, High cd, Red BBSW -2 Back Box Skirt, Wall, White PC2RK 2 -wire Horn/Strobe, Standard cd, Red, Outdoor BBSC -2 Back Box Skirt, Ceiling, Red PC2RHK 2 -wire Horn/Strobe, High cd, Red, Outdoor BBSCW -2 Back Box Skirt, Ceiling, White Notes: * Add" -P " to model number for plain housing (no "FIRE" marking on cover), e.g., P2R -P t Add " -SP " to model number for "FUEGO "marking on cover, e.g., P2R -SP *Standard cd," refers to strobes that include 15,15/75, 30, 75, 95,110, and 115 candela settings. "High cd "refers to strobes that include 135, 150, 177, and 185 candela settings. All outdoor units ending in "IC include a weatherproof back box. ►`` .' T 02006 System Sensor. / L �/ /� 3825 Ohio Avenue • St. Charles, IL60174 Products „e.,r.tassn,tgerrtochangewmoutn ce.vrsitsymmsemammr« SENSOR' Phone: 800 SENSOR2 "Fax: 630-377-6495 current current product iMamanon.inddigthe latest* mice of this data sheet. AOS- 0395-003 .12/06•11676