Correspondence ADM January 3, 2012 1111E111 ARCHITECTURAL GROUP RECEIVED INTERNATIONAL JAN 0 4 2012 CITY OF TIGA5D BUILDING DIVISION Dan Nelson Senior Plans Examiner City of Tigard Re: Tenant Improvement (The Body Shop) Permit Number BUP2011 -00262 9532 SW Washington Square Dear Mr. Nelson: We have received your plan review comments dated 12/16/11, and have the following information in response: 1. Detail 2/A4.1 has been revised to clarify the suspension and bracing for the suspended sheetrock ceiling. Additionally, structural calculations and details are enclosed. Please note that the sheetrock portion of the ceiling is less than 1000sf, and is bounded by braced bulkheads, so horizontal restraint wire and rigid bracing are not required. 2. Details 5/A4.1 and 6/A4.1 have been revised to clarify the suspension and bracing of the storefront soffit. Additionally, structural calculations and details are enclosed. 3. The estimated permit valuation of the project is $105,000. We hope this information will allow for prompt approval of the plans, but if any additional information is required, please contact our office at any time. Sincerely, . Quin Wichmann Architectural Group International 15 W. SEVENTH STREET a COVINGTON, KENTUCKY 41011 PHONE: 859.261.5400 a TOLL FREE: 877.261.5400 0 FAX• 859.261 5530 eastoffice@agi- us.com a www.agi- global.com Q/2o oz)R62. Iminsep K KOHRS LONNEMANN HEIL ENGINEERS, PSC ♦� L FT. THOMAS, KENTUCKY H DAYTON, OHIO ENGINEERS COLUMBUS, OHIO NEW YORK, NEW YORK 800.354.9783 WWW.KLHENGRS.COM December 23, 2011 Dan Nelson, HLVLi V I Senior Plans Examiner JAN 0 4 2012 (503) 718 -2436 dann @tigard- or.gov CITY OF TIGARD BUILDING DIVISION Re: The Body Shop 9532 Washington Square Mechanical TI Dear Mr. Nelson: In response to your plan review letter dated December 23, 2011 pertaining to the application for permit for the project listed above, we respectfully submit the following clarification: 1. Please show attachment of VAV to structure. Response: The VAV box is existing to remain, and existing attachment to structure is existing to remain. If we can provide you any further information regarding the above, please contact us at your convenience. Respectfully, KOHRS LON '' ' ANN HEIL ENGINEERS, P.S.C. f Li Itia '.bert A unnemann, P.E. • December 16, 2011 n TI GARD, RE: TENANT IMPROVEMENT City of Tigard Project Information Building Permit: BUP2011 -00262 Construction Type: 2 -B Address: 9532 SW Washington Sq. Occupancy Type: M Area: 1491 Sq. Ft. Stories: 1 Name: Body Shop Sprinklers: Yes The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2007 edition; 2007 Oregon Fire Code. Please respond to conditions below. 1) Provide calculations and construction details (including seismic bracing details for non full height partitions) for all walls and sheetrock ceilings. Note: The roof structure may be approximately 30' above the finished floor. OSSC 106.1 2) Please provide calculations and construction details for the soffits and storefront construction. Every structure, and portion thereof, including non structural components that are permanently attached to structures and their supports and attachments, shall be designed and constructed to resist the effects of earthquake motions in accordance with ASCE 7 as modified by Section 1613.7. The seismic design category for a structure is permitted to be determined in accordance with Section 1613 or ASCE 7. OSSC 1613.1 3) Please provide a permit valuation based on the total work being performed. Permit valuations shall include total value of work, including materials and labor, for which the permit is being issued, such as electrical, gas, mechanical, plumbing equipment, flooring, ceilings and any fixture attached to the building. If, in the opinion of the building official, the valuation is underestimated on the application, the permit shall be denied, unless the applicant can show detailed estimates to meet the approval of the building official. Final building permit valuation shall be set by the building official. When responding, provide an itemized letter stating in what way each numbered issue has been addressed in the revision. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Dan Nelson Senior Plans Examiner (503) 718 -2436 dann @tigard- or.gov 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.639.4171 TTY Relay: 503.684.2772 • www.tigard- or.gov 1)4 1'2. -/1 qu 6g4.17 kt260