Correspondence City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 U1 October 19, 2006 • Jeff Bertozzi 700 NE 102'd TfI ARD( { t x { s Portland, Oregon 97220 „ • RE: Addition Project Information Building Permit: BUP2006 -00469 Construction Type: VN Address: 10200 SW Hoodview Dr. Occupancy Type: U2 Area: 528 sq. ft. Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; the State of Oregon Residential Specialty Code ORSC) 2005 edition and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. According to RI06.1.1, construction documents should be of sufficient clarity to indicate that the location, nature, and extent of work complies with the provisions of this code and acceptable engineering practice. In order to satisfy this code provision, the following items require your attention in order to complete this plan review: 1. Minimum post bracing and connection should be per Figure R502.9, for posts not supporting the hot tub. 2. The floor dead load exceeds the limitations of R301.2.2.2.1, please provide engineered design for the loads imposed on the deck, the footings, the ledger connection, and have the engineer review the entirety of the plan for structural adequacy. When submitting revisions or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Loraine Williams, Plans Examiner (503) 718 -2708 Loraine @tigard - or.gov 1 Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov ® TTY Relay: 503.684.2772