Loading...
Report Jun. 29. 2007 9:56AM i 5 - 0 No. 1445 P. 1 GeoP tf Engineering. hic. June 28, 2007 Real -Wood Geotechnlcal Solutions •Investigation • Design Project No. 07 -1137 • Construction Support Chuck Arnett Custom Homes, Inc. 7288 SW 171 Drive Aloha, OR 97007 Attn: Chuck Arnett RE: GEOTECHNICAL REVIEW OF FOUNDATION EXCAVATION HILLSIDE ESTATES LOT 7 TIGARD, OREGON In May of 2007, representatives of GeoPacific Engineering, Inc. (GeoPacific) visited the project site to observe removal of unsuitable fill materials from the western and southern portions of the proposed house foundation. Poorly compacted fill with debris up to about 10 feet thick was removed from the house foundation footprint area and beyond. Some of this unsuitable fill appears to extend beneath the driveway turnaround area. The overexcavated areas were then backfilled with imported reject rock and compacted. On -call density testing was performed to verify that adequate compaction was achieved. Based on the results of our compaction tests, the granular fill was compacted to at least 90% of the Modified Proctor at the tested locations. On June 28, 2007, GeoPacific engineering geologist, Paul A. Crenna, visited the project site to observe the subgrade conditions. The foundation footings are largely poured but the walls have not yet been formed. Exposed native soil subgrade on the eastern portion of the excavation consists of stiff to very-stiff clayey silt soil. Based on the observed subgrade conditions and our density test results, we consider the foundation excavation subgrade to be suitable for support of spread footings to a minimum allowable bearing pressure of at least 1,500 psf. We recommend that additional compacted structural fill be placed in the building interior once the foundation walls are completed in order to establish a minimum 1 H: 1 V setback between footings and the base of cut slopes. GeoPacific should be contacted to verify compaction of the recommended backfill. The rear footing -to slope setback is considered adequate at approximately 8 feet horizontal. Within the limitations of scope, schedule and budget, GeoPacific attempted to execute these services in accordance with generally accepted professional principles and practices in the fields of geotechnical engineering and engineering geology at the time the report was prepared. This report was prepared for Chuck Amett Custom Homes, Inc., only and should not be relied upon by third parties without consulting GeoPacific. • 7312 SW Durham Road Tel (503) 598 -8445 Portland, Oregon 97224 Fax (503) 598.8705 •