Specifications MECHANICAL EQUIPMENT FORMS
PREPARED FOR: RECEIVED
MAR 10 2004
CITY OF TIGARD
SPECIAL DISTRICTS B UILDING DIVISION
ASSOCIATION OF OREGON
PREPARED BY:
� PROFF
N.E 4 ,
7820 � `) `
✓_ A
IVY 4 1
OREGON V
l9 vGY13,'kg c� •
R \ � / Stfi
r
Y LG�
EXP JUNE 30, 2005 CITY OF TIGARD
Approved . -t .64. 0.[CA ..
inditionaily Approved ....... -- .
r- x only the work a desZ bed in .. 00
PERMIT N0. ( ]
See Letter to: Follow------ --
Attach - - - -- - - - -. : 6►
Job • d ress: K Date: S " O
By: A A
Larry Grimes Engineer
iiii 7510 N.E VANCOUVER MALL DRIVE, SUITE 100 OBI
VANCOUVER, WASHINGTON 98662 (360) 254-9234 CE COPY
March 9, 2004
Form 2a Project Name: Jp.e.ci / 2,i Page 1
SUMMARY
Project 1. Project Name C , ` w � D - 17 - ) G- 4S x 4(0"
2. Project Address - (ZS'' ,S'W 4apti p4o,,,
3. City/Town T t-v-dQ 5. County
4. Building, Gross Area (ft 6. No. of Floors 2,
Attached Chapter Type ID Description Attach
Forms and Building Envelope Form 3a Building Envelope - General ❑
Worksheets 3b Prescriptive Path — All Climate Zones CI
Worksheet 3a Wall U- factor ❑
Check boxes to 3b Roof U- factor ❑
indicate attached 3c Floor U- factor ❑
forms and
worksheets Systems Form 4a Systems — General
4b Complex Systems ❑
Worksheet 4a Unitary Air Conditioners - Air Cooled X
4b Unitary Air Cond. - Water & Evap. Cooled ❑
4c Unitary Heat Pump - Air Cooled ❑
4d Unitary Heat Pump - Water Cooled ❑
4e Packaged Terminal A.C. - Air Cooled ❑
4f Packaged Terminal Heat Pump - Air Cooled❑
4g Water Chilling Pkgs. - Water & Air Cooled ❑
4h Boiler - Gas -Fired and Oil -Fired ❑
4i Furnace & Unit Heaters - Gas & Oil -Fired ❑
4j Simultaneous Heating and Cooling ❑
4k Natural Ventilation ❑
41 Fan Motor Energy ❑
Lighting Form 5a Lighting - General ❑
5b Interior Lighting Power - Tenant Method ❑
5c Int. Ltng. Power - Space -by -Space Method ❑
Worksheet 5a Lighting Schedule ❑
5b Interior Lighting Power ❑
Applicant 7. Name r/(t ( 4041 i re. 10. Telephone 9-7 / - Z 3 s - 3449
8. Company ��, � ( j 11. Date — / 7 D i
9. Signature
Attached No. of Pages Description of Documentation
Document- By-? 4- 539 40 l&
ation
(10/03) Forms 2 -1
Form 4a Project Name: S pie..c la I b- Page: 2.
SYSTEMS - GENERAL
Applicability Plans /Specs
Discussion of qualifying
exceptions on page 4 14 Show complince by including a drawing sheet detail
number, specification section and subparagraph.
1. Applicablity (Section 1317)
Is this form
14 Form Required. Complete form if a new HVAC system is being installed, or
components of an existing HVAC system are being replaced (I.e., equipment, controls,
ductwork, and insulation.)
0 Exception. The building or part of the building qualifies for an exception
from HVAC code requirements. Applicable code exception is
Section 1317.1. Portions of the building that qualify:
Area: Exception 1 ❑ 2 ❑ 3 ❑
Area: Exception 1 ❑ 2 - ❑ 3 ❑
Area: Exception 1 ❑ 2 ❑ 3 ❑
❑ Form Not Required. This project does not contain work required to comply with code.
2. Simple or Complex Systems (Section 131 or 1317.10)
NKSimple System. Building contains only Simple HVAC System(s). Complete this
form (4a) and equipment efficiency worksheets as required. Form 4b is not required..
❑ Complex System. Project includes a Complex System. Complete this form (4a);
form 4b and, equipment efficiency worksheets-as. required.
3. System and Zone Controls (Section 1317.4.1 and 1317.4:2)
Complies. All new HVAC systems include at least one temperature control device
responding to temperatures within the zones
❑ Exception. HVAC system qualifies for an exception from zone control requirements.
The applicable code exception is Section 1317.4.2, Exception .1 ❑ 2 ❑
Portions of the building that qualify:
The plans /specs show compliance in the following locations:
4. Control Capabilities (Sec. 1317.4.2.1)
K Complies. Zone thermostats are capable of being set to the temperatures
described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone
controls shall be capable of providing a temperature range or deadband of at least
5 degrees F within which the supply of heating and cooling energy to the zone is
shut off or reduced to a minimum.
❑ Exception. The building qualifies for an exception to the deadband requirements.
The applicable code exception is Section 1317.4.2.1 Exception 1 ❑ 2 ❑
Portions of the building that qualify:
The plans /specs show compliance in the following locations:
4 -1
Form 4a Project Name: cpeua (.2),s4,-74,41 Page: 3
SYSTEMS - GENERAL
•
5. Off -hour Controls
5.1 Automatic Setback or Shutdown (Section 1317.4.3)
Complies. Systems must have at least one of the following features:
❑ Control Setback Complies. Each system is equipped with automatic control capable of
reducing energy through control setback during periods of nonuse or alternate use of
spaces served by system.
❑ Equipment Shutdown Complies. Each system is equipped with automatic control capable
of reducing energy equipment shutdown during periods of nonuse or alternate use of
spaces served' by system.
HVAC systems with equipment shutdown are equipped with at least one of the
following:
❑ Programmable controls (1317.4.3.1 (1))
❑ Occupant sensor (1317.4.3.1 (2))
❑ Interlocked to a security system (1317.4.3.1 (3))
❑ Manually activated timers with 2 -hour operation max
X kxception. The building qualifies for an exception to the requirement for automatic
setback or shutdown controls (first set of exceptions)
The applicable code exception is Section 1317.4.3 Exception 1 ❑ 2 g
The plans /specs show compliance in the following locations:
52. Shutoff Damper Controls (1317.4.3.3)
❑ Complies. Each outdoor air supply and exhaust system is provided with motorized
dampers or other means of automatic volume shutoff or reduction during periods
of nonuse or alternate use of spaces served by system.
KException. The building qualifies for an exception to the motorized damper requirement.
The applicable code exception: Section 1317.4.3.3, Exception 1 ❑ 2 ❑ 3 ❑ 4 jg(
The plans /specs show compliance in the following locations:
5.3. Optimum Start Controls (Section 1317.4.3.2)
❑ Complies. Separate HVAC systems have controls capable of varying start -up time of
system to just meet temperature set point at time of occupancy.
%Exception. HVAC systems have a design supply air capacity not exceeding 10,000 cfm.
The plans /specs show compliance in the following locations:
M2..1
6. Heat Pump Controls (Section 1317.4.4)
TNo Heat Pump. The plans /specs do not call for a new heat pump
❑ Complies. All new heat pumps equipped with supplementary heaters are controlled to
minimize the use of supplemental heat as defined in Section 1317.4.4.
The plans /specs show compliance in the following locations:
7. Equipment Performance (Section 1317.5.)
❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC
equipment, combustion heating equipment, or heat - operated cooling equipment.
Complies. All new HVAC equipment have efficiencies not less than those required by the
code.
The following equipment efficiency worksheets are attached:
4a 4b 4c 4d 4e 4f 4g 4h 4i 4j
), ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
4 -2
•
Form 4a Project Name: 57 .c_el Page: '
SYSTEMS - GENERAL
•
8. Hot Gas Bypass (Section 1317.5)
AC(No Hot Gas Bypass
® Complies. See allowable amount of hot gas bypass as a percentage of total cooling
capacity in table below.
Hot Gas Bypass
Unit ID Rated Cooling Capacity Capacity
Allowable Hot Gas Bypass
Rated Cooling Capacity Max Hot Gas Bypass
Capacity
<240,000 Btu /h 50%
>240,000 Btu /h 25%
❑ Exception. Unitary packaged system with cooling capacity no greater than 90,000 Btu /h
9. Economizer Cooling (Section 1317.3)
❑ No Cooling. The building plans do not call for a new fan system with mechanical cooling.
❑ Complies. Each new fan system has an air economizer capable of modulating outside -air
and return -air dampers to provide up to 100 percent of the design supply air as outside air.
X Exception At least one new fan system qualifies for an exception.
The applicable code exception is Section 1317.3, Exception 1 ❑ 2 Pi6 04 05 ❑ 6 ❑
If Exception 3 is selected complete the following:
(a) Total cooling capacity of exempt units 3ob I
(b) Total installed building cooling capacity I h}, 300
)'Complies. Sum of exempt units rated at less than 54,000 btu /hr is
<240,000 or a/b < 0.10 (10% of total building cooling capacity).
Unit Identifier of exempt units: I 'F'C -1 /ct,
The plans /specs show compliance in the following locations:
10. Economizer Pressure Relief & Integration (Section 1317.3.1 and
1317.3.2)
%No Economizers Required. The project does not contain a new fan system requiring
economizers.
❑ Overpressurization Complies. The drawings specifically identify a pressure relief mechanism
for each fan system that will relieve the extra air introduced by the economizer.
❑ Integration Complies. Economizer is capable of providing partial cooling even when additional
mechanical cooling is required to meet the remainder of the cooling load.
❑ Exception. The applicable exception is Section 1317.3.2, Exception 10 20
The plans /specs show compliance in the following locations:
4 -3
Form 4a Project Name: 5 1c / fs Page: <
SYSTEMS - GENERAL
11 . Duct Insulation and Sealing (Section 1317.7 & Section 1317.8)
No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums
❑ Complies. The plans and specifications call for all air - handling ducts and plenums
to be insulated and sealed as required by Sections 1317.7 &1317.8.
? . Piping Insulation (Section 1314)
N o New Piping. The building plans and specifications do not call for new piping serving a
heating or cooling system or part of a circulating service water heating system.
❑ Complies. All new piping serving a heating or cooling system or part of a circulating service
water heating system complies with the requirements of the Code, Section 1314.1.
❑ Exception. New piping qualifies for exception: Section 1314.1 Exception 10 20
13 Gravity Vent Controls (1317.4.5)
❑ Complies. Stair and shaft vents. Stair shaft vents shall be equipped with motorized dampers
that are capable of being automatically closed during normal building operation and are
interlocked to open as required by fire and smoke detection systems.
❑ Complies. Gravity hoods, vents and ventilators. All outdoor air supply and exhaust hoods,
vents and ventilators shall be equipped with motorized dampers that will automatically shut
when the spaces served are not in use.
0 Exception. The building qualifies for an exception to the gravity vent controls.
The applicable code exception is Section 1317:4.5.2 Exception 1 02. ❑
Compliance details in plans /specs:
. Dampers (1317.5.5)
Complies. Motorized outdoor air supply and exhaust air dampers have a maximum leakage rate
of 3 cfm /ft2 at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1989.
The plans /specs show compliance in the following locations:
15. Service Water Heating (Sec. 1315)
)(No New Water Heating. The building plans and specifications do not call for new water heaters,
hot water storage tanks or service hot water distribution systems.
❑ Complies. All new water heaters, hot water storage tanks or service hot water distribution
systems comply with the requirements of the Section 1315.
❑ Exception. The applicable code exception is Section: 'Exception:
Portions of the building that qualify:
16. Distribution Transformers (Section 1316.1)
X l No Distribution Transformers. The plans /specs do not call for new distribution transformers.
❑ Complies. All new distribution transformers comply with efficiency, testing, and labeling
requirements of Section 1316.1.1.
The plans /specs show compliance in the following locations:
4-4
Form 4a Project Name: '.?` ,a , / D Page: (2
SYSTEMS - GENERAL
1
17. High Occupancy Ventilation (Section 1203.2.13)
❑ Complies. HVAC systems with ventilation air capacities of 1,500 CFM or greater that
serve areas having an average occupant load of 20 square feet per person or less from
Table 10 -A have a means to automatically reduce outside air intake.
Identify applicable systems:
The plans /specs indicate where equipment (i.e. carbon dioxide sensor) and sequence is specified:
1
❑ Exception. HVAC systems are equipped with an energy recovery device with at least 50%
ecovery effectiveness.
No High Occupancy Systems. Project does not contain an HVAC system as described above
18. Occupancy Ventilation (Section 1203.2)
/Complies. Mechanical ventilation systems provide the required amount of ventilation specified
in Section 1203.2.1.
® Complies. Natural ventilation systems provide the, required amount of ventilation designed by
a registered architect or engineer as specified by Section1203.2.4. Attach worksheet 4m.
The plans /specs show compliance on the following pages
❑ Exception. The building qualifies for prescriptive natural ventilation: Exception 10
19. Parking Garage Ventilation (Section 1203.2.11)
4 No Enclosed Garages. The building plans and specifications do not call for enclosed Group S
parking garages with a ventilation exhaust rate greater than 30,000 CFM.
❑ Complies. The plans and specifications call for carbon monoxide sensing devices as required
by Section 1203.2.11.
❑ Exception. Open parking garages.
20. Swimming Pools, Spas and Hot Tubs (Section 1315.5)
X No New Pools. The building plans and specifications do not call for new swimming pools, spas
or hot tubs.
❑ Complies. All new swimming pools, spas or hot tubs are equipped with pool cover, pool heater
controls and heat recovery as required by Section 1315.5.
k 2,. Fume Hoods (Section 1317.2.1.)
, No Fume Hoods. The building plans do not call for fume hood systems that have a total
exhaust rate greater than 15,000 cfm.
Complies. Fume hood systems have at least one of the following features:
❑ Variable air volume hood exhaust and room supply systems capable of reducing exhaust and
makeup air volume to 50% or less of design values.
❑ Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no warmer
than 2° F below room set point, cooled to no cooler than 3° F above room set point, no
humidification added, and no simultaneous heating and cooling used for dehumidification control.
❑ Heat recovery systems to precondition makeup air from fume hood exhaust in accordance with
1318.3 - Exhaust Air Energy Recovery, without using any exception.
The plans /specs show compliance in the following locations:
I
4 -5
Form 4a Project Name: S 'er da I ; �.� Page: "7.
SYSTEMS GENERAL
22. Kitchen Hoods (Section 1317.11)
Not Regulated. The plans /specs do not call for any new kitchen hoods with exhaust capacity
greater than 5,000 cfm each.
O Complies. All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm
have at least 50 percent of the required makeup air; (a) unheated or heated to no more than 60 °F;
and (b) uncooled or evaporatively cooled.
The plans /specs show compliance on the following pages
24. Outside Heating Systems (Section 1317.12)
$ No Outside Heating Systems. The plans /specs do not call for new permanently installed
heating systems outside the building.
O Complies. All new permanently installed outside heating systems are radiant gas fired systems
controlled by an occupancy sensor or timer switch as required by Section 1317.12.
4 -6
Worksheet 4a Project Name: ' p . b ( ,,e i Page: g
UNITARY AIR CONDITIONER - AIR COOLED
Equipment (a). (b) (c) (d) (e)
Discussion of equipment
Proposed Performance
ratings and equipment Capacity Seasonal or Compliance
definitions on page 4 -19. Equip. ID Model Designation (Btu /h) Steady State :: Part Load Schedule (A -E)
C.L.t -/ 3r ` 538 i 0 8 i`"3-; 300 — 1.
Require Indicate source of information
Documentation _ ARI Unitary Directory, Section AC, page:
_ ARI Applied Products directory, Section ULE, Page:
Product data (Attach data furnished by the equipment supplier, I.e., "cut sheets ")
Code Cooling Capacity (btu /h) Minimum Rating
Compliance
Required Sohedule Equipment Type . Seasonal or
Efficiencies Over But not over - Steady State : PartLoad:
. • 0 � 65,000. na 9 7 =SEER
Single Package Without a: 65,000 135 000 • 10:3 EER n/a
This schedule of A Heating Section or With Electric 135000 240,000 9.7. EER* .'. n/a
equipment efficiencies Heat H
Resistance ea
was reformatted from the 241),000- 760,000 9.5`EER 95 IPLV
code, Table 13 -L 760,000 = 9.2EER ` 9.2 IPLV
0 65 • - na 10 SEER
Split S stem Without a Heating 65,000 135,000 • 10.3 EER n/a .
Y
B Section or With Electric 135,000 240,000 ` 9:7. EER :: n/a
Resistance Heat • 240,000 ` 760,000 9:5 EER 95 IPLV
760,000 9.2 EER 9.2' IPLV
0 65,000 na 10 SEER
Single Package With a Heating 65,000 135,000 10.1 EER n/a
C Section Other Than Electric 135,000 240,000 9.5 EER n/a
Resistance 240,000 760,000 9.3 EER • 9.7 IPLV
760,000 9.0 EER 9.4 IPLV
0 65,000 na 10 SEER
Split System With a Heating 65,000 135,000 10.1. EER n/a
D Section Other Than Electric 135,000 240,000 9.5 EER n/a
Resistance 240,000 760,000 9.3 EER 9.7 IPLV
760,000 - 9.0 EER . 9.4 IPLV
E Condensing Unit Only 135,000 - 10.1 EER 11.2 IPLV
•
4 -10
. ��
- 1„ - pia , 4- > ; � _
ARI* CAPACITIES
OUTDOOR
INDOOR OUTDOOR STANDARD NET COOLING TOTAL SOUND
FAN COIL TYPE
SECTION SECTION CFM (Btuh) kW SEER EER RATING
(Decibels) -
�E_
619E009 538C009 215 8,500 0.88 10.5 9.70 64 q�,
619E012 538C012 302 11,600 1.15 11.0 10.10 65
High Wall --- -4•619E018 538A018 480 17,300 1.66 11.3 10.40 70 E-
619E024 538A024 550 22,600 2.09 12.0 10.80 68
538A018 500 18,000 1.64 12.0 10.95 70
6190024 538A024 600 22,800 2.07 12.0 11.00 68
Ceiling 619CO36 538A030t 840 30,000 2.73 12.0 11.00 68 L
Suspended 538A036 840 34,000 3.25 12.0 10.45 68 I - -
619C048 538A048 1200 47,000 4.37 12.0 10.75 72 H
619C060 538A060 1600 58,000 5.18 12.0 11.20 72 .'"
' 619F024 538A018 525 18,300 1.76 11.0 10.40 70 '' `:
In-Ceiling 538A024 915 24,000 2.20 11.0 10.90 68 !
Cassette 619F036 538A030 915 30,000 3.13 10.8 9.60 68 �}
538A036t 915 33,000 3.14 10.8 10.50 F 68
LEGEND ARI 210/240 ARI 270 I `
Bels - Sound Levels (1 bel = 10 decibels)
EER - Energy Efficiency Ratio ° "
SEER - Seasonal Energy Efficiency Ratio , , sk t;
'Air Conditioning &Refrigeration Institute. � -
tlncludes Liquid Line Solenoid Valve. . q!,
NOTES: (When used with
1. ARI rating condition is 80 F db, 67 F wb air entering evaporator and matching unit.)
95 F db air entering condenser. -
2. Total kW is for total system, including compressor and outdoor and
indoor fans.
3. Ratings are based on 25 ft of interconnecting refrigerant line.
}
!s'
k
_ „,
_.,-
, ,___,
,-, ,::
_..,,, _
•,...,.,,
_,,,,..
=
,,,,,...
., .,..._,
,_.,,,
F
• , _, h
1
4 t
1386