Loading...
Correspondence October 27, 2004 • //ia � ��Ill�l�u�.r L 2 '6‘ CITY OF TIGARD ®REGON Charles Coiling 13835 SW Hall Blvd Tigard OR 97223 RE: Permit MST2002 -00372 This letter is notification that the referenced permit for the work at the above address has not received a final inspection. Since more than six months has elapsed with no inspection activity, it is assumed that the work has either been suspended or abandoned and this permit will be expired by limitation as provided in Section R105.5 of the Oregon One & Two Family Dwelling Specialty Code. Please be advised that, in the event of a subsequent sale of your home, the lack of inspection approval for this permit could delay closing. The lending institution and /or the title company may require proof of a completed permit for such work prior to the sale of the property. We will allow thirty (30) days from the date of this letter for an opportunity to apply for reinstatement of this permit for the purpose of final inspection(s). Certain fees will be applicable at the time of reinstatement. If you have any questions about the permit or its status, please call Jeanne Temple in our office at 503 - 718 -2433. 11/41705- I V m Sincerely, pLeY/1 e_lud �Lc.�i� Darrel "Hap" Watkins b Inspection Supervisor cc: Property File 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 6 i W /0, 4A, October 31, 2002 CITY OF TIGARD Charles Coiling 13835 SW Hall Blvd REG ®Id Tigard, OR 97224 RE: Structure at 13835 SW Hall Blvd The City of Tigard Building Division has reviewed the submitted building plans for the above referenced address in accordance with the Oregon Structural Specialty Code (OSSC), 1998 edition and the 1999 Uniform Fire Code as amended by TVFR. Please be advised that operating a home business requires a home occupation permit from the planning department. Please contact the planning division regarding compliance with the standards contained in the Tigard Development Code 18.742. A prior HOP permit was issued to this address, but was for a different applicant and is not transferable from one party to another. A new HOP permit will be required if conducting any business activity. Plans have been reviewed and issued in error, current permits are hereby invalid, no work shall be performed until new permits have been issued. Current plans show a 3,168 square foot U- Occupancy on the first floor for the parking of private pleasure vehicles, A 3,168 square foot second story 51- Occupancy for general storage of non- hazardous materials. And a 2,592 square foot lean to carport type structure (also a U- occupancy). OSSC section 312.2.2 special area provisions: The total area of a private garage used only as a parking garage for private or pleasure -type motor vehicles where no repair work is done or fuel dispensed may be 3000 square feet. Option 1) remove the carport structure from the plans and limit the main floor to 3,000 square feet by creating a small private office area limited to no more than 10% of the main use or Option 2) Create a two hour Area Separation wall between the carport and the main structure with a parapet to divide the area to less than 3,000 per side and create the office as mentioned in option 1. A rated one -hour occupancy separation is required between the first floor and the second floor. Revised plans shall show a listed one -hour floor ceiling assembly with protected openings. Proposed structure is in a R4.5 zone limiting the total height of the structure to 30 feet. Plans show the proposed structure is 34 feet in height. Structure shall not exceed 30'feet in height without planing approval. Obtain proper planing approval or lower the structure to 30' in height. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Structural comments: 1) Column to beam attachments and column to footing attachments are lacking provide details. 2) Footing line "G" has three point loads of 9 thousand pounds each. In addition to the floor loading of the second floor at 3,080 pounds per foot. Provide calculations showing the existing two foot wide footing is adequate for the proposed loads. 3) Second story floor load shall be rated at 125# live load for light storage 4) Provide roof shear transfer details that reflect the style of proposed construction. 5) Elevation plan shows dormers on the roof provide framing details and proper support. 6) Plans show stairs that are lacking proper details for the rise, run, support, handrails and guardrails. Provide details. 7) Provide a complete load path shown on revised structural cross section from the roof to the ground all connection details, shear walls with nailing and hold downs will be shown. 8) Provide structural and framing details on the attachment of the breezeway to the existing residence. Due to the major code items identified in this letter the entire structure must be redesigned and submitted for review per Section 106.4.3 Oregon Structural Specialty Code. If you have any questions regarding this review, please contact myself at (503) 718 -2436 or Gary Lampe a, Building Official at 503- 718 -244.8 Sin erely, Daryl Jones Plans Examiner CC: File Hap Watkins, Inspection Supervisor Gary Lampella, Building Official