Plans (9) • August 31, 2004 - . • - . • • - • 0 Brian' Blalock - Senior Plans Examiner ti • City of Tigard - . 13125 SW Hall Blvd. • Tigard, OR 97223 • RE: Building Permit No. BUP2004- 00334, Dear Mr. Blalock: This letter is a partial response to your plan review comments dated July 22, 2004. I have attached revised • . _ . o details that address items No. 1 and 2. I am requesting a deferral for Item No. 3 (ADA counter revision) to allow additional time to review acceptable options with the Owner. - _ Item No. 1: Revised detail B3/A7.3 delineate blocking and attachment for new soffit at Transaction County. Detail C4/A7.3 does not apply to any location. q 1 3 Item No. 2: New detail C3/A7.3 delineates support system for typical gypsum wall board ceiling: Item No. 3: We are requesting that this item be addressed as, a deferred submittal. ti ° Please do not hesitate to call me if you have any questions. Thanks. • Sincerely, o N N LRS Architects, Inc. 5 0 V • • Paul I. Boundy Principal " ' N - N ` N S - - N . r S d • x 0 0 - 3 i I g 1 • 1 EXISTING ROOF DECK EXISTING 4X12 @ 4 i J \k tt I TOE NAIL W/ (2) 16d NAILS • EA END TYP s 12' -0" AFF� • ACT-7 1466, n 2X4 @ 4' -0" OC J^ 2X4 BLOCKING MTL CHANNEL 8'-6" AFF_ #10 SCREWS AT 1' -0" OC W/ FLAT WASHERS s'o METAL FRAMING SOFFIT PARALLEL TO SOFFIT • • i I EXISTING ROOF DECK EXISTING 4X12 @ 4' -0" OC \ / N—MTL HANNEL 2X4 BLOCKING ABOVE SOFFIT MTL S UD @ 1' -2" OC 11111111111 8'-6" AFF , , I • SOFFIT PERPENDICULAR TO STRUCTURE B3. SOFFIT AT PERMIT COUNTER SCALE: 1 1/2"=1-0" I P c h Z t e c t s 1 n C . 1171 SW Salmon • Suite 100 • Portland, OR 97205 • Tel, 503.221.1121 • fax. 503.221.2077 • • TIGARD CITY HALL & PERMIT CENTER PROJECT NUMBER: 203341 DATE: 23 August 2004 p /� "/ � REVISION: 1 O3 //-1 . 3 Copyright ® 2004 CRS Architects, Ina. I q 3 • i 12 ga. hanger wire gypsum panel i ' `: : O O O • main tee e 1 y 0 •�_... ^ 0 1 ° • 0 � w � - �I _ e• cross ® �� fire channel � expansion y notch main tee splice ,. , = CROSS CHANNEL DETAIL 5/8" GYP BD • X 48" MAXIMUM MAIN TEE ON CENTER SPACING cross tee or angle 24" MAXIMUM CROSS CHANNEL ON CENTER SPACING cross channel molding / 48" MAXIMUM 12 GA WIRE SPACING O / O •:: / • PERIMETER DETAIL 7 1. SUSPENDED GYPSUM BOARD CEILING SCALE: NTS G 3 Ar4 .3 I Y C IZ Z t 2 C 1 S ! i1 C 1121 SW Salmon • Suite 100 • Portland, OR 97205 • Tel. 503.221.1121 • Fax. 503.221.2077 TIGARD CITY HALL & PERMIT CENTER PROJECT NUMBER: 203341 Q cl 1.1 DATE: 31 August 2004 /� V REVISION: Copyright C 2004 CRS Architects, Inc.