Correspondence Mark VanDomelen tA 010 V 00 °.
From: Kira Govshtein <kirarealty @comcast.net> I I 0 Li 6 Sub 4 r 8, A24 'b
Sent: Wednesday, December 14, 2011 3:17 PM
To: Mark VanDomelen
Cc: Ron Bunch
Subject: Re: Ash Creek Condos
Hi Mark,
I really appreciate all your comments.
Thank you very much.
All the best,
Kira Govshtein
On 12/14/2011 10:20 AM, Mark VanDomelen wrote:
Hi Kira,
As I stated in my previous email, the valuation submitted is supposed to include the total value of the work, including
materials and labor, for which the permit is being issued. The original building permit with the valuation of $2,000,000
was issued on 11/15/2010. The original plans that were submitted and approved at that time included the seismic
calculations and design. The Site work permit for the vault and fire line was issued on 2/8/11. The Fire protection permit
for the interior sprinkler work was issued on 2/09/11. The only other permits issued were for plumbing, mechanical,
electrical, and fire alarms for the common areas.
Thank you,
Mark VanDomelen
Building Official
City of Tigard
markv@tigard or.gov
(503)718 - 2448
From: Kira Govshtein [mailto:kirarealty@comcast.net]
Sent: Tuesday, December 13, 2011 6:49 PM
To: Mark VanDomelen
Cc: Ron Bunch
Subject: Re: Ash Creek Condos
Dear Mark,
Thank you so much for your time and effort to explain the "code upgrades" /city requirements.
We would like to ask you for clarification in two areas:
1
1. Did the $2,000,000 permit application for structural and repair work include all of the requirements per
section 3401 through 3405 (Existing Structure) of the Oregon Structural Specialty Code? When was the
$2,000,000 permit obtained by Horizon?
2. Sprinkle system. When were the two permits for sprinkle system, vault and supply line described in the sixth
paragraph of your letter obtained by Horizon?
Again, thank you so very much for your help.
Kira Govshtein.
503 -544 -5501
On 12/12/2011 2:01 PM, Mark VanDomelen wrote:
Hi Kira,
This email is to recap the conversations that we've had at the counter regarding the fire damage repair at the Ash Creek
Condominiums. The main "theme" of our conversation was on what items the city considered to be required "code
upgrades ". There were two main code related items that were required based on the damage sustained by the
structure. These two main items were the requirements out of the Oregon Structural Specialty Code (OSSC) Chapter 34
for substantially structurally damaged buildings and the requirements out of Chapter 9 for substantially damaged Group
R2 buildings (the occupancy category that Ash Creek Condominiums falls within).
Chapter 34 (Existing Structures) of the OSSC addresses repairs to existing structures. Section 3401.4 and its subsections
allows leeway for the continued use of existing materials (section 3401.4.1), and, except for structural repairs or
alterations, for the use of like materials for repairs (section 3401.4.2). However, section 3401.4.2 does require that, in
general, materials permitted by the current OSSC for new construction shall be used. All materials would be required to
be installed per their listing and manufactures installation instructions.
As we discussed, section 3405.2 of the OSSC addresses Substantial structural repair of vertical elements of the lateral
force resisting system. Once demolition work began, it was determined that the existing walls were not sheathed with
plywood and depended on gypsum wall board for lateral force resistance. Furthermore, it was obvious that there was
substantial fire and water damage to this element. Based on my site visit the day after the fire and all information
provided, It was determined that the building had sustained substantial structural damage. I then requested an
evaluation report by a registered design professional as required per section 3504.2.1. The evaluation determined that if
the building were repaired to its pre- damaged state, it would not comply with the provisions of the code for wind and
earthquake loads. Section 3405.2.3 then requires that the building be rehabilitated to comply with applicable provisions
of the OSSC for load combinations, including wind and seismic loads. New structural members and connections were
required by the rehabilitation design to comply with provisions of the OSSC for new buildings of similar structure,
purpose, and location.
No adjustment to the original valuation of the project was provided at the time of this evaluation and no additional
permit fees were collected. The valuation provided at the time of permit application for all structural and repair work
was $2,000,000.
OSSC section 903.2.8 provides the requirements for existing Group R2 structures when substantial damage occurs.
Substantial damage is deemed to have occurred when the cost of restoring the structure to its original condition would
be equal to or exceed 25% of the assessed value of the structure before the damage occurred. When substantial damage
occurs, each unit that is substantially damaged must be provided with an automatic sprinkler system meeting the
requirements of NFPA 13R. When more than 50% of the units in a building are substantially damaged, the entire building
must be provided with such an automatic sprinkler system. It was determined that this building did sustain substantial
damage to more than 50% of the units and thus was required to be provided with an automatic sprinkler system
throughout.
2
There were two permits obtained in relation to the required fire sprinkler system. One permit for the system throughout
the interior of the structure and one permit for the site work to install the vault and fire supply line from the property
line to the building. The valuation provided by the contractor for the interior sprinkler system was $31,600. The
valuation provided for the vault and fire supply line was $35,550.
The city of Tigard does not distinguish specifically which items and portions of valuations are related to "code upgrades ".
We review plans for, and inspect buildings to meet the minimum requirements of the code. All plans submitted for the
repairs were reviewed to ensure they meet these minimum requirements. The city would not deny approval of plans or
inspections that exceeded the minimum requirements. The valuation submitted are supposed to include the total value
of the work, including materials and labor, for which the permit is being issued.
I hope this helps to clarify the city's position regarding the code requirements for this project. Please feel free to contact
me if you have any more questions about this matter.
Sincerely,
Mark VanDomelen
Building Official
City of Tigard
markv @tigard - or.gov
(503)718 -2448
From: Kira Govshtein [mailto:kirarealty@comcast.net]
Sent: Friday, December 09, 2011 12:42 PM
To: Mark VanDomelen
Subject: Re: Ash Creek Condos
Hi Mark,
I really appreciate your email.
It can wait until next week.
Get well.
All the best.
Kira Govshtein
On 12/9/2011 12:25 PM, Mark VanDomelen wrote:
Hi Kira,
I have been out sick since we spoke and am still not up to working. I will try to get an email out to you early
next week.
Thank you,
3
Mark VanDomelen
Building Official
City of Tigard
markv@tigard-or.gov
(503)71 8 -2448
l
a
DiSCLA,t6�,It R: _inai:S cent or received by City of € ig d employees are subject oYSuFbti record . . to s. requested, R!tested e
. _.
. � City �, 0.F wsc3 ���� ;� to 01 F... ;.i�, ��.. 2d 6tb.x�e., 3: i....�tk..•'."J �.w. t_�I. `i3.4..i
may be discos d another party t em from disclosure under Oregon Public i c F F are ;'c� :31 i� )E1`�' unless �;tix �; �, l �' +� C�{J. �i..l�! Records Law. °'1�l�� �.'"e retained
by the City of Tigard in cornpiiadge with the Oregon �l Rules "City General � t , , Schedule.'
�er�i�;µ�r���i=��; c�i�:,, i�� �u �i Records i��ifi�r�� . .��E�i;t,�:�ui.'
No virus found in this message.
Checked by AVG - www.avg.com
Version: 10.0.1415 / Virus Database: 2102/4069 - Release Date: 12/09/11
Kira Govsftein
PrincipaCBroker
tMetroporitan Realty, LLC
phone: 503 -544 -5501
fax: 503- 892 -9136
www.metropolitanrealtynw.com
No virus found in this message.
Checked by AVG - www.avg.com
Version: 10.0.1415 / Virus Database: 2102/4076 - Release Date: 12/12/11
Kira govslitein
Principal Broker
itetropo[itan Realty, LLC
phone: 503 -544 -5501
fax: 503- 892 -9136
www.metropolitanrealtynw.com