Loading...
Plans MI 7 kLt - D-oo g - co O a_,- I tqccs / Fire & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series TY -B — 2.8, 5.6, and 8.0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it ?,t D escription is recommended that the end user be ,.�.,� Via ;f" > 3. consulted with respect to the suitability :, ;` ;?'«\' The Series TY -B, 2.8, 5.6, and 8.0 of these coatings for any given corro- " � ) if K- factor, Upright and Pendent Sprin- sive environment. The effects of ambi- klers described in this data sheet are ent temperature, concentration of ',, <»; standard response - standard cover- chemicals, and gas /chemical velocity, , , - �_.: �P,'a age, decorative 5 mm glass bulb type should be considered, as a minimum, 4 „, a , spray sprinklers designed for use in along with the corrosive nature of the � . , , � �' T light, ordinary, or extra hazard, corn- chemical to which the sprinklers will be '_ - ,A, mercial occupancies such as banks, exposed. w ° „ `` � ° =' °# _.3 hotels, shopping malls, factories, refin- eries, chemical plants, etc. An intermediate level version of the Series TY -B Pendent Sprinkler can be The recessed version of the Series obtained by utilizing the Series TY -B TY -B Pendent Sprinkler, where appli- Pendent Sprinkler in combination with cable, is intended for use in areas with the Model S2 Shield. a finished ceiling. It uses a two- piece e` e Style 10 (1/2 inch NPT) or Style 40 (3/4 WARNINGS 4 e ` inch NPT) Recessed Escutcheon. The The Series TY-B Sprinklers described E ' Recessed Escutcheon provides 1/2 herein must be installed and main - inch (12,7 mm) of recessed adjust- tained in compliance with this docu- _ - j 5 ment or up to 3/4 inch (19,1 mm) of ment, as well as with the applicable " total adjustment from the flush pen- standards of the National Fire Protec - dent position. The adjustment pro- tion Association, in addition to the '2. . vided by the Recessed Escutcheon re- standards of any other authorities hay - duces the accuracy to which the fixed ing jurisdiction. Failure to do so may , *,,,„ - 31' pipe drops to the sprinklers must be impair the performance of these de- cut. vices. Corrosion resistant coatings, where The owner is responsible for maintain- applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. that which would otherwise be ob- The installing contractor or sprinkler tained when exposed to corrosive at- manufacturer should be contacted mospheres. Although corrosion resis- with any questions. tant coated sprinklers have passed the standard corrosion tests of the appli- Model/Sprinkler IMPORTANT Identification Always refer to Technical Data �® Sheet TFP700 for the "INSTALLER Numbers WARNING” that provides cautions with respect to handling and instal- TY1151 - Upright 2.8K, 1/2 "NPT lation of sprinkler systems and com- TY1251 - Pendent 2.8K, 1/2"NPT ponents. Improper handling and in- TY3151 - Upright 5.6K, 1/2 "NPT stallation can permanently damage TY3251 - Pendent 5.6K, 1/2 "NPT a sprinkler system or its compo- TY4151 - Upright 8.0K, 3/4"NPT nents and cause the sprinkler to fail TY4251 - Pendent 8.0K, 3/4 "NPT to operate in a fire situation or cause TY4851 - Upright 8.0K, 1/2 "NPT it to operate prematurely. TY4951 - Pendent 8.0K, 1/2 "NPT Page 1 of 8 DECEMBER, 2007 TFP151 TFP151 Page 5 of 8 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD WAX WAX OVER BRASS PLATED POLYESTER COATED COATED LEAD COATED 2.8 PENDENT (TY1251) 1/2" and 175 PSI (12,1 BAR) N/A NPT UPRIGHT (TY1151) PENDENT (TY3251) 5.6 and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) • 1/2" UPRIGHT (TY3151) OR NPT 175 PSI (12,1 BAR) RECESSED PENDENT (TY3251) (SEE NOTE 1) N/A 8.0 PENDENT (TY4251) 3/4" and 175 PSI (12,1 BAR) NPT UPRIGHT (TY4151) RECESSED PENDENT (TY4251) 175 PSI (12,1 BAR) N/A 8.0 PENDENT (TY4951) 1/2" and 175 PSI (12,1 BAR) NPT UPRIGHT (TY4851) NOTE: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C -UL); and, the Approval by the City of New York. TABLE B, MAXIMUM WORKING PRESSURE Technical Operation Data The glass Bulb contains a fluid which expands when exposed to heat. When Approvals the rated temperature is reached, the UL and C -UL Listed. fluid expands sufficiently to shatter the FM, LPCB, VdS, and NYC Approved. glass Bulb, allowing the sprinkler to (Refer to Table A for complete ap- activate and water to flow. proval information including corrosion resistant status.) Design Maximum Working Pressure /� Refer to Table B. Criteria Discharge Coefficient K = 2.8 GPM /psi (40,3 LPM /bar1 /2) The Series TY -B Pendent and Upright K = 5.6 GPM /psi (80,6 LPM /bar112) Sprinklers are intended for fire protec- K = 8.0 GPM /psi (115,2 LPM /bar1 /22) tion systems designed in accordance with the standard installation rules rec- Temperature Ratings ognized by the applicable Listing or Refer to Table A. Approval agency (e.g., UL Listing is Finishes based on the requirements of NFPA Sprinkler: Refer to Table A. 13, and FM Approval is based on the Recessed Escutcheon: White Coated, requirements of FM's Loss Prevention Chrome Plated, or Brass Plated. Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, Physical Characteristics is to be used for recessed pendent Frame Bronze installations. Button Brass /Copper a Sealing Assembly a� Beryllium Nickel w /Teflont m Bulb Glass Compression Screw Bronze Deflector Copper a Bushing (K =2.8) Bronze .- . ScheduI Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule -10 /Schedule -40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule -10 /Schedule -40 gives you the extra quality assurance you demand. Our Sch -10 (1' / "- 8 ") pipe and Sch -40 (I"- 2''4 ") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Sch -40 Sp . NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ WI/Lift (21') Wt/Lift (24') WI/Litt (25') Schedule-10/Schedule-40 product can be In; mm In: mm Lbs /Ft; Kg /m Lbs/Ft; Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg "hot -dip" galvanized to meet FM requirements for dry systems in 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 accordance with the zinc coating 25 26.6 2.5 3.05 70 1,120 1,280 1,334 specifications of ASTM A -123. 11/4' 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 Superior Coating 1W 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 Our advanced formula mill coating of- 2" 2.067 3.650 5.13 30 2,300 2,628 2,738 fers a clean, durable surface, It is also 50 52.5 5.4 7.63 30 1,043 1,192 1,242 paint -ready for custom color applications 2W 2,469 5.790 7.86 19 2,310 2,640 2,750 without special preparation. 65 62.7 8.6 11.73 19 1,048 1,197 1,247 The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is SCh -10 Specifications coated with our new Antibacterial For- NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') WI/Litt (24') Wt/Lift (25') mula, "ABF ". In scientific laboratory In; mm In; mm Lbs /Ft; Kg /m Lbs/Ft; Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg test, ABS proved to have superior resis- 1" 1.097 1.400 1.81 91 2,675 3,053 3,185 tance to microbial colonization of pipe 25 27.9 2.1 2.70 91 1,213 1,385 1,445 walls, thereby delaying or possibly pre- 11/4" 1.442 1.810 2.52 61 2,319 2,664 2,760 venting the onset of Microbiologically 32 36.6 2.7 3.75 61 1,052 1,208 1,252 Influenced corrosion (MIC) when the 11/2' 1.682 2.080 3.04 61 2,664 3,045 3,172 First Sprinkler System is first installed. 40 42.7 3.1 4.52 61 1,208 1,381 1,439 American Made ` 72 2'157. - ?;.--'; - 4.22 - 37..,.:205i • - - :. 2 ;344 - , _ 2;442 - -~ ;:- . .. 50 54.8 3.9 6.28 37 930 1,063 1,108 Meets `Buy American" requirement 21/2° 2.635 3.530 5.89 30 2,224 2,542 2,648 and is available through distributors in 65 66.9 5.3 8.77 30 1,009 1,153 1,201 the USA, Canada and Mexico. 3" 3.260 4.330 7.94 19 1,728 1,975 2,057 Specifications' & App 80 82.8 6.4 11.82 19 784 896 933 4" 4.260 5.610 11.78 19 2,238 2,558 2,665 Schedule -10 /Schedule -40 pipe are in 90 108.2 8.3 17.53 19 1,015 1,160 1,209 compliance with the following: 5" 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 ASTM A -135, and NFPA 13. Both pipe 6" 6.357 9.290 23.03 10 1,951 2,230 2,322 products have a working pressure rating 150 161.5 13.8 34.27 10 885 1,012 1,053 of 300 psi maximum and also meet the 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 stringent requirement for the following 200 209.5 24.5 59.75 7 1,100 1,256 1,309 tests: • Welded Outlets el 41t• 0 • Hydrostatic Pressure Listed Approved Listed • Side Wall Rupture • Vibration Test ��� ® /F /ow Conrro/ 16100 S. Lathrop • Harvey, IL 60426 Customer Service: aIIi®d 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882 -5543 TUBE 8 CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708 - 339 -1806 S5 - 3