Correspondence rA fie January 26, 2006 CITY OF TIGARD OREGON Lasher Design Todd Lasher 5632 N Atlantic Ave Portland, OR 97217 RE: T I -2 HOUR WALL/FLOOR CEILING & BATHROOMS - REVIEW Project Information Building Permit: BUP2006 -00057 Construction Type: II B Tenant Name: The Light -Up Co. Occupancy Type: S2B Address: 11225 SW Greenburg Rd. Occupant Load: 27 Area: 7,816 sq ft Stories: 2 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and the State of Oregon Fire Code (OFC) 2004 edition. The submitted plans are approved subject to the following conditions. 1. All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. 1003.3.1.8 OSSC 2. The main exit shall be provided with signage indicating "THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS" Section 1003.3.1.8 OSSC 3. Provide one 2 -A rated fire extinguisher in the new area. The extinguisher shall be located so that no usable space has a distance greater than 75 feet to the extinguisher. OFC 906.3 4. Live Loads Posted: The live loads for which each floor has been designed shall be conspicuously posted by the owner in that part of each story in which they apply, using durable metal signs, and it shall be unlawful to remove or deface such notices. The occupant of the building shall be responsible for keeping the actual load below the allowable limits. 1607.3.5 OSSC American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA • requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC which may not include all of the requirements of the ADA. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Val He e Senior Plans Examiner