Loading...
Correspondence June 23, 2004 Bob Becker Robert Becker Interior Design 9660 SW Eagle Court Beaverton, OR 97008 RE: TENANT IMPROVEMENT Building Permit: BUP2004 -00291 Occupancy Type: B Tenant Name: Cash & Go Construction Type: VN Address: 10763 SW Greenburg Road, Suite 110 Occupant Load: 27 Area: 2,266 Sq Ft Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans are approved subject to the following conditions. 1. All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. 1003.3.1.8 OSSC 2. The means of egress shall be provided with illumination of not less than 1 foot candle at the floor level anytime the building is occupied. 1003.2.9.2 OSSC 3. Provide one 2 -A rated fire extinguisher so that no usable space has a distance greater than 75 feet to the extinguisher. Standard 10 -1, Chapter 3 TVFR99 -01. Deferred submittals such as the Mechanical System will be charged a deferred submittal fee based on the valuation of the portion of the work being deferred. The minimum fee shall be $200.00. American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC which may not include all of the requirements of the ADA. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors /° throughout all phases of construction. 106.4.2 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 109.1 OSSC CHAP. 11, DIV. IV ADAAG FIGURE 28 1997 UNIFORM BUILDING CODE 36 min 915 ''18 min 36 min ass 1 ass 1115 18 • 18 min 1■1■ : Mil • • c r ; lav • E i c I • 40 E c 1 1 dear aO 40 1 floor dear 1 space ,, floor ( space 48 min 1 I 48 min 1220 1220 42 min 18 1065 455 O ' c o E n E l) : clear 1 1a floor t space 4 60 min 1525 I ADAAG FIGURE 28—CLEAR FLOOR SPACE AT WATER CLOSETS 1- 134.48 CHAP. 11, DIV. IV 1997 UNIFORM BUILDING CODE ADAAG FIGURE 25 Pull Side j j X Push Side se Ea � II 18 ink% 4 v+arrlenea i MEMO NOTE: x 12 In (305 mm) r door hes both • close and latch (a) Front • • . — Swinging Doors Pull Side Push Side aro X E~ a › .mo o NOTE x n 36 h (215 minimum y = 60 In nun); (1575 ); x � 42 (106106 5 mm) ... 54 I (1370 mm). NOTE y 481n (1220 mm) minimum If door has cloaQ. (b) Hinge Side Approaches — Swinging Doors X Pull Side • 24 eras X Push Side } aw 24nan I o a 6 e yN NOTE: y e 54 In (1370 mm) nhkdrthum rdoor has 1 I doom NOTE y = 48 In (1220 mm) minimum If door has both a latch and closer. (c) Latch Side Approaches — Swinging Doors • NOTE All doors in alcoves shell comply wkh the deerences for front approaches. ADAAG FIGURE 25— MANEUVERING CLEARANCES 1- 134.45