Loading...
Plans x,.; ,.,.,.,, I ERVE3 5 i� A 30 EXIT t - "' OPEN OFFICE 64 711, . ,. A 301 305 O y S Tro f . • 11' '.10' sT L 04 HZ t n l�a c�r'IN 5 fro 304 p. v ' 302 + Occupancy Type �/ Occupancy Load OFFICE , 13 ,OFFICE ,i-4 OFFICE G Construction cp cy Type 1 04' 303 302 / 7 rs Rated Corridor Energy Code � 9 l i ' " Accessibility C ^. y - V . i : _ y •n .:..vw off.. "' $ ♦ t� �h ` * �, , ., --, - e =�"1, '�7 Ara:: 1 ' 1la 1w .. r (IC O _ ITY OF ' ,, Conditionally Approved � AL THIRD FLOOR PLAN For only the as d scribed i 6 ... . ------------------- Wsi• ,. Alk rARTI No. �� �: PERMIT ( Y See Letter to: Follow .................... ); JoG.A' • s t -- `7 Bp . OFFICE COPY illITMITIIMMEMOMMINON 11M1111!�1 :1 ■ ■11 IIIMMIIIMPAIIIIIVAI 11111111 ■11111111 ■11111117111111 In 1111111111111:11111 ■ Ct111111 v iii-s E2W2C C2C21C 1111. _ 11111'vN111ammlS■lil 1111111111111: ©®1111111011A1111 1111111111 ■1 11 11111 ® � 11 ■1111 11111111►! ■11111111111111111■ _ 1111111►► ■11":111111x111, ■Fi1111�' ►1111 111111111'!111 - - - -L � hx REFLECTED CEILING PLAN • •{ :t Arai , 1 -1'_0" • $ r f ,, */:* ry / k TENANT IMPROVEMENT 1 LINCOLN 10300 SW GREENBURG RD. PORTLAND, OREGON F � cc m n Submitted By: T & L Communications Inc. p cs� P.O. Box 87387 ?, N Vancouver, WA 98661 O v p rii 360 -737 -9725 Z 4-71 v 360- 737 -9648 fax ticomm @wa- net.com 37428 CLE Oregon Contractor 67787 CCB Number 6981 Metro Number 684 LEA Supervising Journeyman Larry E. Bushaw A U D I B L E / V I S I B L E N O T I F I C A T I O N SPECTF6 Selectable Output Strobe �--\• SYSTEM and Horn /Strobes \....,.� SENSOR Models Available . ;ate':1� , .� { x Strobes Red White t q f .,.. "' s • < S1224MC S1224MCW S1224MCP S1224MCPW ` " '4,.',, S1224MCK S1224MCSP f Hom /Strobes Red White P1224MC P1224MCW n..,,, i . P1224MCP P1224MCPW =z ` 41 P1224MCK ,-, r P1224MCSP ` li , Hems `s ` Red White vrii*..,..x. H12/24 1112/24W .`g;;° 53.224McStrobe H12/24K +-' 4 Product Overview Operates on either 12V or 24V SpectrAlert Selectable Output Horns, Strobes, and Hom /Strobes offer enhanced fea- Widest range of candela options: tures that include the widest range of candela options available and the capability to 12V: 15 and 15/75 candela recognize and self - adjust for either 12 or 24 volt operation. With an overall feature 24V• 15, 15/75, 30, 75, 110 candela set that combines performance, Installation ease, flexibility, and a consistent, aesthetically pleasing appearance, the SpectrAlert Selectable Output devices Easy candela selection provide both the innovation and efficiency synonymous with the SpectrAlert name. Lower current draw Performance. SpectrAlert selectable output wall -mount horns, strobes, and horn /strobes Easy DIP switch selection for horn offer key performance features long associated with the SpectrAlert name. The select - options able candela strobes and horn /strobes offer average current draws that are not only lower than conventional fixed - candela SpectrAlert products, but also lower than similar Easy mounting with QuIckClickT" selectable candela products. By consuming less current, the ability to connect even more Synchronlzable with MDL devices per loop is possible, resulting in a lower installed cost. Sync • Circuit module Installation. SpectrAlert selectable output horns, strobes, and horn/strobes offer the Meets UL1971, NFPA72, and ADA same installation- friendly features synonymous with the SpectrAlert name, such as the signaling requirements option of 2- and 4 -wire operation: the ability to use standard size hackhoxes with no encroachment into the box; and universal mounting incorporating the labor - saving All strobe and horn/strobe models incorporate a QuickClick feature. Such labor - savings features make wire connections simple and fast, new patent- pending voltage booster design that has a more consistent flash bulb voltage over further reducing installed cost. the range of candela selections. The benefit to Flexibility. SpectrAlert selectable output strobes and horn/suobes offer the broadest the customer is a high quality strobe device. range of candela options. In addition, the selectable output strobes and horn/strobes can operate on either 12V or 24V, with no setting required; the device recognizes and O C self- adjusts to the correct current automatically. Temporal 3 or Continuous tone options continue to be available, in either an Electromechanical or 3kHz pattern. LISTED fS5.4.YN17NNI 64 Aesthetics. SpectrAlert selectable output horns, strobes, and horn/strobes incorporate T -,4nt i G554V702NK13751 the same stylish, low profile design of the conventional SpectrAlert products, for a con - (t0 NEA sistent and aesthetically pleasing appearance across the entire product line. ill ® approved 11251209:222 '^'a'm 12742E (13:14409:224 3014150 1.2544 t • Engineering Specifications General fire protective service. Horn/strobc shall be wired as a primary SpectrAlert horns, strobes and horn/strobes shall be capable of signaling notification appliance and comply with the Americans mounting to a standard 4" x 4" x 1 back box or a single gang with Disabilities Act requirements for visible signaling appliances, 2" x 4" x 1' /s' back box using the universal mounting plate flashing at 1Hz over the strobe's entire operating voltage range. p, included with each SpectrAlert product. Also, SpectrAlert prod- The strobe light shall consist of a xenon flash tube and associated ucts, when used in conjunction with the accessory Sync•Circuit lens/reflector system. The horn shall have two tone options, two Module, shall be powered from a non -coded power supply audibility options (at 24 volts) and the option to switch between and shall operate on 12 or 24 volts. 12 volt rated devices shall a temporal 3 pattern and a non - temporal continuous pattern. have an operating voltage range of 9 -17.5 volts. 24 -volt rated Strobes shall be powered independently of the sounder with the devices shall have an operating voltage range or 17 -33 volts. removal of factory installed jumper wires. The horn on horn/ SpectrAlert products shall have an operating temperature of strobe models shall operate on a coded or non -coded power sup - 32° to 120 °F and operate from a regulated DC or full wave ply (the strobe must be powered continuously). rectified, unfiltered power supply. Synchronization Module Strobe Module shall be a System Sensor Sync•Circuit listed Strobe shall be a System Sensor SpectrAlert Model to UL 464 and shall be approved for fire protective service. The listed to UL 1971 and be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns strobe shall be wired as a primary signaling notification appliance at temporal 3. Also, the module shall silence the horns on horn! and comply with the Americans with Disabilities At require- strobe models, while operating the strobes, over a single pair of menu for visible signaling appliances, flashing at 1Hz over the wires. The module shall be capable of mounting to a 4 x strobe's entire operating voltage range. The strobe light shall con- 4 x 2 /s" back box and shall control two Style Y (class B) or sist of a xenon flash tube and associated lens/reflector system. one Style Z (class A) circuit. Module shall be capable of multiple zone synchronization by daisy chaining multiple modules together Hom /Strobe Combination and re- synchronizing each other along the chain. The module Horn/Strobe shall be a System Sensor SpectrAlert Model shall not operate on a coded power supply. listed to UL 1971 and UL 464 and shall be approved for Specifications Walk Test Weight, strobe and horn /strobe Voltages SpectrAlert horn /strobe and horn only 8.8 oz. 12 or 24VDC and FWR unfiltered work on "walk tests" with time dura- tions of 4 seconds or greater Mounting Operating voltage range* 4° x 4' x 1 or 2" x 4' x 1' /8" 12V: 8- 17.5V; 24V: 16-33V Input Terminals standard boxes 12 to 18 AWG Operating voltage range* (with Indoor Operating Temperature Sync•Circuit module, MDL) Dimensions 32 °F to 120 °F (0 °C to 49 °C) 12V: 9- 17.5V; 24V: 17 -33V Strobe and horn /strobe with universal *Note for Strobes: Do not exceed; 1) Maximum humidity plate 16-33 or 8 -17.5 voltage range limit; 5" x 5 /a" x 2's />s 95% as tested per UL464 2) maximum number of 70 strobe lights Strobe and horn /strobe with small Operating Temperature when connecting the MDL Sync module footprint plate Weatherproof (horn and horn /strobes) with a maximum line impedance of 4 33/e" x 55 /a' x 2 32 °F to 150 °F (0 °C to 66 °C) ohms per loop and; 3) maximum line Horn with universal mounting plate (outdoor strobe only) impedance as required by the fire alarm 5" x 5 x 15/1.6" - 40 °±9 °F to +151 °±9°F control manufacturer (- 40°±5 °C to +66 °±5 °C) Horn without mounting plate U.S. Patent Numbers 2 x 5 x 15/16" ULC Canadian Models 5,593,569 -40 °C to 66 °C 5,914,665 Weight, horn only 6,049,446 7.2 oz. SpectrAlert Current Draw FWR Operating DC Operating Current- FWR Operating DC Operating Current- Strobe Strobe Current -Horn Current-Horn Horn Candela (mA RMS) (mA RMS) (mA RMS) (mA RMS) Audibility Series Setting 12V 24V 12V 24V 12V 24V 12V 24V tdDA) S1224MC 15 112 64 127 59 . Strobes 15/75 135 74 127 69 30 93 90 75 158 160 110 • 208 209 P1224MC 15 112 64 127 59 45.7 57.5 44.4 57 75 Horn /Strobes 15/75 135 74 1.27 69 45.7 57.5 44.4 57 75 30 93 90 57.5 57 75 75 158 160 57.5 57 75 110 208 209 57.5 57 75 H12/24 Horns 45.7 57.5 44.4 57 75 SpectrAlert Mounting and Operation Candela Selections Selectable Horn Tones For strobe candela selection, adjust slide switch located on the Temporal Low Volume Electromechanical rear of the product while watching the viewing window on the 3000 Hz Interrupted side of the reflector. High Volume Electromechanical Permissible Candela Settings 3000 Hz Interrupted Candela Voltage Non-Temporal Low Volume Electromechanical settin6 r 12V 24V 3000 Hz Interrupted 1 15 15/75 OK OK Hi Volume Electromechanical I -� OK OK 3000 Hz Interrupted 30 OK ` 75 OK DIP Switch Operation Factory Viewing Window 110 OK OFF ON !DIP Switch A0 ::33-00 Default Low f High ® ' o -0 Temporal 1111111 I Non- Temporal 0 -- Electromech. 1111 3000H.z tug 0 0 Base (rear) A0110-30 Typical weatherproof mounting with universal plate r WBB Plate # 8-36 x 1/2" Flat Head r�l - � ` Screw (4 total) tLf6 / �_�� ( p____ A0120-00 .� ?` , Gasket _ 1 �� Conduit • "�'� Entrance Slot Paper Liner Locking Rib For Plate Gasket SpectrAlert Ordering Information Model Description Model Desedptlon P1224MC Selectable Output Horn /Strobe, 12/24 volt, red H12/24 Horn, 12/24 volt, red P1224MCW Selectable Output Horn /Strobe, 12/24 volt, white H12/24W Horn, 12/24 volt, white P1224MCP Selectable Output Horn /Strobe, 12/24 volt, red, H12/24K Horn, 12/24 volt, red, weatherproof plain housing Accessories P1224MCPW Selectable Output Horn /Strobe, 12/24 volt, MDL Sync•Circuit Module, red white, plain housing P1224MCK Selectable Output Horn /Strobe, 12/24 volt, red, MDLW Sync•Circuit Module, white weatherproof MDLA Sync•Circult Module, red, Canadian model P12.24MCSP Selectable Output Horn /Strobe. 12/24 volt, red, MDLWA Sync•Circuit Module, white. Canadian model "FUEGO" housing S-MP Small Footprint Mounting Plate, red, for single - S1224MC Selectable Output Strobe, 12/24 volt, red gang back box S1224MCW Selectable Output Strobe, 12/24 volt, white S-MPW Small Footprint Mounting Plate, White, for single - S1224MCP Selectable Output Strobe, 12/24 volt, red, plain gang back box housing BBS Surface Mount Back Box Skirt, red S1224MCPW Selectable Output Strobe, 12/24 volt, white, BBSW Surface Mount Back Box Skirt, white plain housing D-MP Universal Mounting Plate (replacement), red S1224MCK Selectable Output Strobe, 12/24 volt, red, D-MPW Universal Mounting Plate (replacement), white weatherproof S1224MCSP Selectable Output Strobe, 12/24 volt, red, WBB Weatherproof Back Box "FUEGO" housing Notes Agency Listings — Indoor models: UL, ULC, FM, CSFM, MEA. Weatherproof models: UL, CSFM (strobe only), MEA, ULC. All of these SpectrAlert products arc designed for wall mount only. All weatherproof models must use weatherproof back box model WEB. Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However, it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. All 15/75 candela strobes or hom/ strobes are recommended for 20' x 20' rooms or less. System Sensor Sales and Service System Sensor Headquarters System Sesser Canada System Sensor M Cldna System Sensor — Far East System Sensor — India 3825 Ohio Avenue Ph: 905.812.0767 Ph: 86.29.524.6253 Ph: 85.22.191.9003 Ph: 91.124.237.1770 x.2700 St. Charles, IL 60174 Fr: 905.812.0771 Fx: 86.29.524.6259 Fx: 85.22.736.6580 Fx: 91.124.237.3118 Ph: 800 /SENSOR2 System Sensor Europe System Sasso, Is SNrgyore System Sesser — Hesbsge System Sensor — Russia Fx: 630/377-6495 Ph: 44.1403.891920 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 Documentson- Demand Fr: 44.1403.891921 Fr: 65.6273.2610 Fx: 613.54.281.172 Fx: 70.95.937.7983 800/736 -7672 x3 www.systemsensor.com O 2004 System Sensor. The comparty reserves the right to change product specifications without notice. AOS0325 4•io /04