Loading...
Permit r CITY OF TIGARD GARD BUILDING PERMIT •,, , PERMIT #: BUP2007 -00245 COMMUNITY DEVELOPMENT DATE ISSUED: 5/10/2007 TIGARD 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 PARCEL: 1S135AB-03400 SITE ADDRESS: 10260 SW GREENBURG RD 720 ZONING: C -P SUBDIVISION: LINCOLN CENTER /LINCOLN TOWER LOT: 014 JURISDICTION: TIG PROJECT: EMC Project Description: Fire alarm REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: FPS FIRST: sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 2N sf N: S: E: W: OCCUPANCY GRP: B TOTAL AREA: 0 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: 36 BASEMENT: sf AREA SEP. RATED: STOR: 12 HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: Y SMOK DET:N DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : Y HNDICP ACC:Y BEDRMS: BATHS: IMP SURFACE: PRO CORR: Y PARKING: VALUE: $ 1,000.00 Owner: Contractor: EQUITY OFFICE PROPERTIES TRUST CAPITOL ELECTRIC CO, INC. ONE SW COLUMBIA ST #300 11401 NE MARX STREET PORTLAND, OR 97258 PORTLAND, OR 97220 Contact #: PRI 503 - 255 -9488 Phone: FAX 503 - 255 -1966 Reg #: LIC 48748 FEES Description Date Amount REQUIRED ITEMS AND REPORTS [BUILD] Permit Fee 5/2/2007 $62.50 [TAX] 8% State Surcha 5/2/2007 $5.00 [FLS] FLS Pln Rv 5/2/2007 $25.00 Total $92.50 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. Issued By: . ,./_,.,,, f. 4 ,41, ✓ _/ Permittee Signature: Of , I ,__ Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. d0 aGo St.) G-(24-6-)1W-4 R D : Fire Protection System Building Permit Applicatio CE� �I FOR OFFICE USE ONLY City of Tigard Received 07 ���� �� e� 2:61 Date /By: Permt No.: it: 13125 SW Hall Blvd., Tigard, OR 97223 MAY v 6+ 11 0(0 17 P ill 7 Plan Revie•t' % ( Other Perm Phone: 503.639.4171 Fax: 503.598.1960 TI��ai] Date /By: TIGARD Inspection Line: 503.639 � ®� t S O Date Ready /By: Jun 10 See Page 2 for Internet: www.tigard- or.gov BOLO DI . -`� Notified/Method: /7 / t-I Supplemental Information TYPE OF WORK REQUIRED DATA: 1- AND 2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ® Addition/alteration /replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation: $ ❑ 1- and 2- family dwelling ® Commercial/industrial ❑ Accessory building ❑ Multi family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 10260 SW Greenberg Road (Lincoln Tower) New dwelling area: square feet City/State /ZIP: 97223 Garage /carport area: square feet Suite/bldg. /apt. no.: 720 Project name: EMC Tenant Improvement Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA: COMMERCIAL - USE CHECKLIST Subdivision: Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. Install fire alarm notification devices in tenant space. Valuation: $1,000.00 Strobes (3), Speakers (2) Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: V Z Name: Shorenstein Realty Service Type of construction: ( 3 Address: One SW Columbia, Suite 300 Occupancy groups: City/State /ZIP: Portland, OR 97258 Existing: B Phone: (503)412 -4800 Fax: (503)412 -4848 New: B ® APPLICANT ® CONTACT PERSON NOTICE Business name: Capitol Electric Co., Inc. All contractors and subcontractors are required to be Contact name: Dan Wilson licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: jurisdiction in which work is being performed. If the City/State /ZIP: applicant is exempt from licensing, the following reasons apply: Phone: ( ) Fax:: ( ) E - mail: dan @cepdx.com CONTRACTOR BUILDING PERMIT FEES* (Please refer to fee schedule) Business name: Capitol Electric Co., Inc. Permit fee: 62.50 Address: 11401 NE Marx Street State surcharge (8% of permit fee): 5.00 City /State /ZIP: Portland, OR 97220 FLS plan review (40% of permit fee): Phone: (503) 255 -9488 Fax: (503) 255 -1966 (Due upon application.) 25.00 CCB lic.: 48748 Total permit fees: 92.50 Amount received: Authorized signature . J This permit application expires if a permit is not obtained Print name: Dan Wilson Date: 4/27/07 within 180 days after it has been accepted as complete. * Fee methodology set by Tri- County Building Industry Service Board. I:\Building \Permits \FPS- PermitApp.doc 03/23/06 440- 4613T(I1 /02 /COM /WEB) NFPA -72 Fire Alarm System Record of Completion Date: 6/4/2007 City of Tigard Inform i Name of protected property: EMC TENA SUITE 720 @ LINCOLN TOWER Address of protected property: 10260 W GREENBURG ROAD TIGARD, OR 97223 /1 Representative of protected property (name /phone): SHORENSTEIN REALTY SERVICES 503.412.4800 Authority having jurisdiction: City of Tigard, Building Services Address /telephone number: 13125 SW Hall Blvd. Tigard, OR 97223 (503) 639 -4171 1. Type(s) of System or Service NFPA 72, Chapter 3 -- Local If alarm is transmitted to locations(s) off premises, list where received: NFPA 72, Chapter 3 -- Emergency Voice /Alarm Service Quantity of voice /alarm channels: Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: NFPA 72, Chapter 5 -- Auxiliary Indicate type of connection: Local energy Shunt Parallel telephone Location of telephone number for receipt of signals: NFPA 72, Alarm: Supervisory: NFPA 72, Chapter 5 -- Proprietary If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72, Chapter 5 -- Remote Station Prime contractor: Central station location: Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One -way radio Digital alarm communicator Two -way radio Others Means of transmission of alarms to the public fire service communications center: (a) (b) System location: Organization name /phone Representative name /Phone Installer Capitol Electric Co. Inc. Dan W. Wilson 503 255 -9488 Supplier Capitol Electric Co. Inc. Dan W. Wilson 503 255 -9488 Service organization Capitol Electric Co. Inc. Dan W. Wilson 503 255 -9488 Location of record (as- built) drawings: Location of owners manuals: Location of test reports: A contract, dated , for test and inspection in accordance with NFPA standard(s) No(s). , dated , is in effect. 2. Record of System Installation Suite 720 Only (Fill out after installations complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NfPA standards as shown below, was inspected by Jeff Morrow on 06/04/07 , included the devices shown below, and has been in service since 06/04/07 x NFPA 72, Chapters 1 2 3 4 5 6 7 (underline all that apply) x NFPA 70, National Electrical Code, Article 760 x Manufacturer's instructions Other (specify): Signed: Jeff Morrow Date: 06/04/07 Organization: Capitol Electric Company, Inc. 3. Record of System Operation Suite 720 Only All operational features and functions of this system were tested by Jeff Morrow on 06/04/07 and found to be operating properly in accordance with the requirements of: x NFPA 72, Chapters 1 2 3 4 5 6 7 (underline all that apply) x NFPA 70, National Electrical Code, Article 760 x Manufacturer's instructions Other (specify): Signed: Jeff Morrow Date: 6/4/2007 Organization: Capitol Electric Company, Inc. 4. Alarm- Initiating Devices and Circuits Suite 720 Only Quantity and class of initiating device circuits (see NFPA 72, Table 3 -5) Quantity: Style: Class: MANUAL (a) 0 Manual stations Noncoded, activating Transmitters Coded (b) Combination manual fire alarm and guard's tour coded stations. AUTOMATIC Coverage: Complete: Partial: (a) 0 Smoke detectors Ion Photo (b) 0 Duct detectors Ion Photo (c) 0 Heat detectors FT RR FT /RR RC (d) 0 Sprinkler waterflow switches: Transmitters Noncoded, activating (e) Other (list): 5. Supervisory Signal- Initiating Devices and Circuits Suite 720 Only GUARD' S TOUR (a) Coded stations (b) Noncoded stations, activating transmitters (c) Compulsory guard tour system comprised of transmitter stations and intermediate stations Note: Combination devices are recorded under 4(b) and 5(a). SPRINKLER SYSTEM (a) Non coded valve supervisory switch at sprinkler riser (b) Non coded valve supervisory switch at sprinkler vault (c) Non coded supervisory air pressure switch at sprinkler riser (d) Site water supply level points Electric fire pump: (e) Fire pump power (f) fire pump running (g) Phase reversal Engine -driven fire pump: (h) Selector in auto position (I) Engine or control panel trouble (j) Fire pump running Engine -driven generator: (k) Selector in auto position (I) Control panel trouble (m) Transfer switches (n) Engine running Other supervisory functions(s) (specify): 6. Alarm Notification Appliances and Circuits Suite 720 Only Quantity and class (see NFPA 72, Table 3 -7) of notification appliance circuits connected to the system: Types and quantities of notification appliances installed: Quantity: 5 Style Y Class: B (a) Bells Inch (b) 2 Speakers (c) Horns (d) Chimes (e) Other: (f) 3 Visual signals Type: ADA SYNCHRONIZED with audible 3 w/o audible (g) Local annunciator 7. Signaling Line Circuits Suite 720 Only Quantity and class (see NFPA 72, Table 3 -6)of signaling line circuits connected to system: Quantity: Style: Class: 8. System Power Supplies (Notification Panel NAC 7.1) (a) Primary (main): NAC 7.1 Nominal voltage: 120 VAC Current rating: 2.5 Amps Overcurrent protection: Type: Circuit Breaker Current rating: 20 Amps Location: FLOOR 7 ELECTRIC ROOM (b) Secondary (standby): X Storage battery: Amp -hour rating: 7 Ah @ 24 VDC Calculated capacity to drive system, in hours: 2.114 Ah 24 60 Engine - driven generator dedicated to fire alarm system: Location of fuel storage: (c) Emergency or standby system used as backup to primary power supply, instead of using a secondary power supply Emergency system described in NFPA 70, Article 700 Legally required standby system described in NFPA 70, Article 701 Optional standby system described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 9. System Software (a) Operating system software revision level(s): N/A (b) Application software revision level(s): (c) Revision completed by: N/A (name) (firm) 10. Comments: Dan Wilson Capitol Electric Co., FLS Supervisor (signed) for central station or alarm service company or installation contractor /supplier (title) Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): This record of completion applies to Suite 720 Only Devices installed conform to NFPA standards. System deviations from the referenced NFPA standard(s) are: NONE Dan Wilson Capitol Electric Co., FLS Supervisor (signed) for central station or alarm service company or installation contractor /supplier (title) Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): (signed) representative of the authority having jurisdiction (title) (date) CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2007-00245 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 5/10/2007 Phone: (503) 639 -4171 A 1p4'Ii Inspection Requests (24 Hrs.): (503) 639 -4175 =�� `__.. , INSPECTION WORKSHEET FOR DATE: 6/4/2007 TIME: 7:01AM PAGE: 96 SITE ADDRESS: 10260 SW GREENBURG RD 720 CLASS OF WORK: SUBDIVISION: LINCOLN CENTER /LINCOLN TOWER LOT #: 014 TYPE OF USE: PROJECT NAME: EMC DESCRIPTION: Fire alarm OWNER: EQUITY OFFICE PROPERTIES TRUST, PHONE #: CONTRACTOR: CAPITOL ELECTRIC CO, INC. PHONE #: 503-255 - 3403 Inspection Request Scheduled For: Date: 6/4/2007 Pour Time: Code # Inspection Description Confirm # Contact # Message 998 Alarm final 049473 -01 503. 780.3222 N Corrections /Comments/ Instructions: • , : A to 1 i'llniElaffillM fo A - w .. ri/PASS I PARTIAL APPROVAL ❑ CANCEL I I NO ACCESS . FAIL ❑ CALL FOR INSPECTION I ADDITI NAL FEES ASSESSED Inspector : Date: Phone #: (503) 718- 2 � J,g. • CITY.OF- TIGARD Fob BUILDING DIVISION PERMIT #: �p.� _�� 1 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: Phone: (503) 639 -4171 �" a "'' ul'lu Inspection Requests (24 Hrs.): (503) 639 -4175 ' INSPECTION WORKSHEET FOR DATE:.'// ( 1 07. TIME: PAGE: SITE ADDRESS: (6°Z Sto GEE-.,--ii �v47� CLASS OF WORK: SUBDIVISION: LOT #: TYPE OF USE: PROJECT NAME: DESCRIPTION: OWNER: PHONE #: CONTRACTOR: (P(17kL - -E . (c_. PHONE #: Inspection Request Scheduled For: Date: Pour Time: Code # Inspection Description Confirm # Contact # Message gia PcL_W-414 PikAL- Corrections/Comments/Instructions: — A 0 C 1G- v PA I I PARTIAL APPROVAL ❑ CANCEL n NO ACCESS FAIL ❑ CALL FOR INSPECTION I I ADDITIONAL FEES ASSESSED Inspector: / �� ) Date: 511 ICY Phone #: (503) 718 -Zeir