Correspondence City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 ,; I1 October 17, 2006 ' • Craig Pierson ?T #I GcA 6615 SW 111 Ave x ��_, Beaverton, OR 97008 RE: HQ GLOBAL REMODEL Project Information Sf3 Building Permit: BUP2006-0042143 Construction Type: 1B Address: 10260 SW Greenburg Rd Occupancy Type: B Area: Please provide Stories: 12 Tenant name: HQ Global Occupant load : Provide The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; the State of Oregon Residential Specialty Code (ORSC) 2005 edition and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans have been reviewed and the following information is required prior to issuance of the permit. A 1 -hour fire rating is required to be maintained throughout the elevator lobby, reception area, and exit access corridors as shown on the approved plan set. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 109.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, �k V Mark VanDomelen, FILE CO P 1 Plans Examiner 1 Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 o Lt ^Ck -rr -F �,1 ~',, ?✓M V I II 1 September 25, 2006 or �� j � to r CITY ®F TIGARD Craig Pierson ®�E�7 ®N 6615 SW 111 Ave Beaverton, OR 97008 RE: HQ GLOBAL REMODEL Project Information Building Permit: BUP2006 -00433 Construction Type: 1B Address: 10260 SW Greenburg Rd Occupancy Type: B Area: Please provide Stories: 12 Tenant name: HQ Global Occupant load : Provide The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; the State of Oregon Residential Specialty Code (ORSC) 2005 edition and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans have been reviewed and the following information is required prior to issuance of the permit. 1. Please provide the square footage calculations and occupant load for each area of the building affected by the work to be performed per OSSC 1004.1. 2. The doors located at the East end of corridor 414 are required to have a minimum 20 minute rating per OSSC table 715.3. Please provide a door mark on sheet A2.0 corresponding to complying door types on the door schedule on sheet A7.0. 3. The sidelight windows into offices 412 and 413 are required to have a 3 /4 hour rating per OSSC table 715.4. Please provide window marks on sheet A2.0 corresponding to complying window types on the window schedule on sheet A7.0. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, I`Iark VanDomelen, Plans Examiner 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 City of Tigard Oregon Comments September 25, 2006 , � Craig Pierson �, 20 - O e 6615 SW 111` Avenue � 06 Beaverton, OR. 97008 ".. • RE: HQ Global Remodel Building Permit: BUP2006 -00433 Construction Type: 1B Address: 10260 SW Greenburg Road Occupancy Type: B Area: Please provide Stories 12 Tenant Name: HQ Global Occupant load: Provide The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; the State of Oregon Residential Specialty Code (ORSC) 2005 edition and the Tualatin Valley Fire and Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans have been reviewed and the following information is required prior to issuance of the permit. 1. Please provide the square footage calculation and occupant load for each area of the building affected by the work to be performed per OSSC 1004.1. Please see sheet G0.0 for the updated square footage calculations and occupant load additions. 2. The doors located at the East end of corridor 414 are required to have a minimum 20 minute rating per OSSC table 715.3. Please provide a door mark on sheet A2.0 corresponding to complying door types on the door schedule on sheet A7.0. Please see sheet A2.0 for requested door mark; which also complies with the door schedule on sheet A7.0. 3. The sidelight windows into offices 412 and 413 are required to have a 3 /4 hour rating per OSSC table 715.4. Please provide window marks on sheet A2.0 corresponding to complying window types on the window schedule on sheet A7.0. Please see sheet A2.0 for the removal of the sidelight windows in both offices 412 and 413. City of Tigard Oregon Comments RECEIVED OCT 1 6 2006 September 25, 2006 CITY OF TIGARD BUILDING DIVISION Craig Pierson Phone: 503.646.6617 C. Schiewe & Associates 6615 SW 111` Avenue Beaverton, OR. 97008 RE: HQ Global Remodel Building Permit: BUP2006 -00433 Construction Type: 1B Address: 10260 SW Greenburg Road Occupancy Type: B Area: Please provide Stories 12 Tenant Name: HQ Global Occupant load: Provide The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; the State of Oregon Residential Specialty Code (ORSC) 2005 edition and the Tualatin Valley Fire and Rescue Ordinance 99 -01 (TVFR99 -01) 1999 edition. The submitted plans have been reviewed and the following information is required prior to issuance of the permit. 1. Please provide the square footage calculation and occupant load for each area of the building affected by the work to be performed per OSSC 1004.1. Please see sheet G0.0 for the updated square footage calculations and occupant load additions. 2. The doors located at the East end of corridor 414 are required to have a minimum 20 minute rating per OSSC table 715.3. Please provide a door mark on sheet A2.0 corresponding to complying door types on the door schedule on sheet A7.0. Please see sheet A2.0 for requested door mark; which also complies with the door schedule on sheet A7.0. 3. The sidelight windows into offices 412 and 413 are required to have a 1/4 hour rating per OSSC table 715.4. Please provide window marks on sheet A2.0 corresponding to complying window types on the window schedule on sheet A7.0. Please see sheet A2.0 for the removal of the sidelight windows in both offices 412 and 413.